Loading...
HomeMy WebLinkAboutENERGY CALC-1EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 48/7/2020 3:58 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY K. HOVNANIANWATERSTONE LOT-08 Street: City, State, Zip:FT. PIERCE , FL , 34951 ARMINA PL. LOT-8 BLOCK 3 Permit Number: Design Location:FL, Fort Pierce County:St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1616 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Dbl, U=0.32 106.11 ft² SHGC=0.30 Dbl, U=0.55 41.00 ft² SHGC=0.34 Dbl, U=0.32 16.44 ft² SHGC=0.27 N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1616.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 1450.20 ft² b. Frame - Wood, Adjacent R=11.0 265.78 ft² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 1616.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:4.626 ft. Area Weighted Average SHGC:0.307 Description Area Insulation Area Insulation Area Insulation Area 15. Credits Pstat 4 (163.6 sqft.) (1716.0 sqft.) (1616.0 sqft.) (1616.0 sqft.) Conditioned floor area below grade (ft²)0 a. Central Unit a. Electric Heat Pump k B t u / h r 28.8 SEER:14.00 Efficiency k B t u / h r Efficiency 28.8 HSPF:8.60 f t ² R 6 448 EF: 0.940 Glass/Floor Area:0.101 Total Proposed Modified Loads: Total Baseline Loads: 54.78 57.63 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY K. HOVNANIAN 1 WATERSTONE LOT-08 Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1616 4 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 FT. PIERCE , St. Lucie ARMINA PL. LOT-8 BL Street Address Comment: Building Type:User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinterSummer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Block1 1616 14059.2 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Main 1616 14059.2 Yes 5 4 Yes Yes1Yes #Floor Type Area Tile Wood Carpet FLOORS R-ValueSpacePerimeter 1 1616 ft² 0 0 1______Slab-On-Grade Edge Insulatio - - - -0167.2 ft Main #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1750 ft² Medium 0.4 0 22.6______N0 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______1 Full attic Vented 1616 ft² N N300 #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 1616 ft² 0.1 Wood______Main Blown 8/7/2020 3:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Main080528NConcrete Block - Ext Insul 0.30Exterior450.7 ft² ____ 2 4.1 0Main084168WConcrete Block - Ext Insul 0.30Exterior141.6 ft² ____ 3 4.1 0Main080648SConcrete Block - Ext Insul 0.30Exterior554.7 ft² ____ 4 4.1 0Main080358EConcrete Block - Ext Insul 0.30Exterior303.3 ft² ____ 5 11 0Main088308-Frame - Wood 0.30.25Garage265.8 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Wood .39 21 ft² None______E Main 73 #Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Double (Clear)0.32 0.3 15.0 ft² 1 ft 0 in 1 ft 0 in NoneVinyl None______Yes1 N 2 W Double (Clear)0.32 0.27 16.4 ft² 1 ft 0 in 1 ft 0 in NoneVinyl None______Yes2 N 3 S Double (Clear)0.32 0.3 16.4 ft² 1 ft 0 in 1 ft 0 in NoneVinyl None______Yes3 N 4 S Double (Clear)0.55 0.34 41.0 ft² 10 ft 0 in 1 ft 0 in NoneVinyl None______Yes3 N 5 E Double (Clear)0.32 0.3 49.8 ft² 1 ft 0 in 1 ft 0 in NoneVinyl None______Yes4 N 6 E Double (Clear)0.32 0.3 24.9 ft² 10 ft 0 in 1 ft 0 in NoneVinyl None______Yes4 N #Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 380 ft² 380 ft² 64 ft 8 ft 1______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1640.2 790.05.000387Wholehouse .1387169.35Proposed ACH(50)1 HEATING SYSTEM #System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Heat Pump/HSPF:8.6 28.8 kBtu/hr ______sys#1Split1 Singl #System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 14 28.8 kBtu/hr c f m 0.7______sys#1Split1 Singl 8/7/2020 3:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT #System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.94 50 gal 60.9 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ #Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 448 ft² Attic 212 ft² Default Leakage Main ( D e f a u l t ) ______1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 Main 8/7/2020 3:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT