Loading...
HomeMy WebLinkAboutLOT-8 MANUAL-JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:58:56 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-8.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Aug 06, 2020Date:Entire House By: Project Information WATERSTONE LOT-8For: ARMINA PL. LOT-8 BLOCK-3, FT. PIERCE, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5040Inside humidity (%) 5911Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A*Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh20160 Heating output Btu h @ 47°F28000 Latent cooling Btuh8640 Temperature rise °F27 Total cooling Btuh28800 Actual air flow cfm960 Actual air flow cfm960 Air flow factor cfm/Btuh0.050 Air flow factor cfm/Btuh0.046 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.67 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) OWNERS SUITE 178 2811 3324 141 152 DINING AREA 147 2751 3095 138 141 GREAT ROOM 219 2849 2410 143 110 BEDROOM 4 150 1546 1659 78 76 KITCHEN 145 143 1741 7 79 OS BATH 60 60 244 3 11 OS WIC 64 1048 663 53 30 FOYER 151 978 828 49 38 MECH 17 17 397 1 18 HALL BATH 79 1034 503 52 23 BEDROOM 3 168 3852 3448 193 157 LAUNDRY 51 50 827 3 38 BEDROOM 2 147 1764 1752 89 80 HOV HALL 31 217 167 11 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:58:56 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 2 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-8.rup Calc = MJ8 Front Door faces: W Entire House 1607 19119 21058 960 960 Other equip loads 0 0 Equip. @ 0.95 RSM 20110 Latent cooling 10239 TOTALS 1607 19119 30349 960 960 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:58:56 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-8.rup Calc = MJ8 Front Door faces: W Job:Project Summary Aug 06, 2020Date:Entire House By: Project Information WATERSTONE LOT-8For: ARMINA PL. LOT-8 BLOCK-3, FT. PIERCE, FL 34951 Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16 Daily range L Relative humidity %50 Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh16698 Structure Btuh16975 Ducts Btuh2421 Ducts Btuh4083 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh19119 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh20110 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh9151 Ducts Btuh1088 CoolingHeating Central vent (0 cfm)Btuh0 16071607Area (ft²)Equipment latent load Btuh10239 1398413984Volume (ft³) Air changes/hour 0.140.26 Equipment total load Btuh30349 Equiv. AVF (cfm)3361 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A*Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh20160 Heating output Btu h @ 47°F28000 Latent cooling Btuh8640 Temperature rise °F27 Total cooling Btuh28800 Actual air flow cfm960 Actual air flow cfm960 Air flow factor cfm/Btuh0.050 Air flow factor cfm/Btuh0.046 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.67