Loading...
HomeMy WebLinkAboutProduct Evaluation Report; Swinging Exterior Door AssembliesR W R W Building Consultants, Inca B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valdco, FL 33595 Phone 813.659.9197 Florida Board of'Professional Engineers Certificate ofAuthodzation No. 9813 Product Category Sub Category Manufacturer Product Name Swinging Therma-Tru Corporation Fiber -Classic and Smooth-Star Exterior Exterior Door 118 Industrial DrEdgerton, Composite Edge Opaque Fiberglass Single Door Doors Assemblies OH 43517 InswingNon-lmutswing Phone 419.2984740. ".thon-Impact" Scope: Product Evaluation report issued'by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for Thera-Tru Corporations, based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Dept of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity Involved in the approval process of the product named herein. Lfmftatfons: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 4. Site conditions that deviate from the details of drawing FL-20461.1 require further engineering analysis by a licensed engineer or registered architect 5. Fiber -Classic & Smooth -Star Door panels require the use of "J" part numbers and must be stained or painted within six months of Installation 6. See drawing FL-20461.1 for size and design pressure limitations. Supporting Documents. 1. Test Report No. Test Standard TEL 01460145 ASTM E330(02), ASTM E331(00) TEL 01461573 ASTM E330-02 & ASTM E331-00 2. Drawing No. Prepared by No. FL-20461.1 RW Building Consultants, Inc. (CA #9813) 3. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA#9813) 4. Quality Assurance Certificate of Participation issued by National Accreditation & Management Institute, certifying that Therma-Tru Corporations is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. SHOPSTAMPREVIEW -#/m" Eden Review Is for general compliance with the Construction Documents. Responsibility for comecu ess of dimensions, details, quantities and safety during fabrication Iles solely with the contactor. I4 NoExcepdonsTaken Reviewed Sr. Dawn Boggio-Korbelak 0 Selected: 11/22/19 Da,.-, $. Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Leb.,lnc. V.K. Wright Stoned& Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 12/7/2017 Sheet 1 of 1