HomeMy WebLinkAboutRevision; Product Approvals for Windows, SGD, Vinyl Soffit, Energy Codes & Driveway + Sidewalk DetailOFFICE USE ONLY: DATE FILED: E VISION FEE: LOCATION/SITE ADDRESS: PERMIT # ) r't) 2 — Dim RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOT#Sy S(,y� ARMINA PLACE FORT PIERCE, FLORIDA, 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: Revised Product Approvals for windows, SGD, and vinyl soffit N CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC1263043 BUSINESS NAME: K. HOVNANIAN FLORIDA OPERATIONS, LLC QUALIFIERS NAME: JOSEPH C SPALT ADDRESS: 3601 QUANTUM BLVD CITY: BOYNTON BEACH STATE: FL PHONE (DAYTIME): 561-364-3316 OVVNER/BUILDER INFORMATION: NAME: K. HOVNANIAN ASPIRE ATWATERSTONE ADDRESS: 3601 QUANTUM BLVD CITY: BOYNTON BEACH STATE: FL PHONE (DAYTIME: 561-364-3316 ARCMTECT/ENGINEER INFORMATION: NAME: DAWN BOGGIO KORBELAK ADDRESS: 90 MATAWAN RD, 5TH FLOOR CITY: MATAWAN, PHONE (DAYTIME): 732-747a600 SLCCC: 9123109 Revised 06130117 ST. LUCIE CO CERT. #: 31426 ZIP: 33426 FAX: 33426 STATE: NJ ZIP: 07747 FAX: FILE ./'+OR91Y FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION T Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WATERSTONE LOT-59 Builder Name: K. HOVNANIAN Street: TBD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE , FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1716.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1450.20 ft2 b. Frame - Wood, Adjacent R=11.0 265.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (1616.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1616.00 ft2 6. Conditioned Floor area above grade (ft2) 1616 b. N/A R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(163.6 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 448 a. U-Factor: Dbl, U=0.32 106.11 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 41.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a. Central Unit - 28.8 SEER:14.00 c. U-Factor: DbI, U=0.32 16.44 ft2 SHGC: SHGC=0.27 13. Heating systems kBtu/hr Efficiency J. U-Factor: N/A ft2 a. Electric Heat Pump 28.8 HSPF:8.60 SHGC: Area Weighted Average Overhang Depth: 4.626 ft. Area Weighted Average SHGC: 0.307 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1616.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Patel Total Proposed Modified Loads: 53.60 Glass/Floor Area: 0.101 P Total Baseline Loads: 57.63 11�7�7ASS 1 hereby certify that the plans and specifications covered by Review of the plans and F4JUIE s j. 0 this calculation are in compliance with the Florida Energy specifications covered by this = - 60*ft Code. u� calculation indicates compliance the Florida Energy Code. q iii,'' .?;,,�, vis rxv, 22•, :`, :••„•�, O with „ PREPARED BY: DATE: 4/21/2020 Before construction is completed this building will be inspected for compliance with Section 553.908 r c9 nx a r n I hereby certify that this building, as designed, is in compliance Florida Statutes. ,11, with the Florida Energy C CpD Wii'L�� OWNER/AGENT: BUILDING OFFICIAL: r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure quAlifid"s' -- - certified factory-sealedin accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 4/21/2020 1:24 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 'Building Type: .Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: WATERSTONE LOT-59 Bedrooms: 4 User Conditioned Area: 1616 Total Stories: 1 1 Worst Case: No K. HOVNANIAN Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot# Block/Subdivision: PlatBook: Street: TBD County: St. Lucie City, State, Zip: FT. PIERCE, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl t. 1616 14059.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1616 14059.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 167.2 ft 1616 R' ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft' 0 W Medium N 0.4 N 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1616 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1616 ft. 0.1 Wood 4/21/2020 1:24 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS t Adjacent Space Tn Wall TypeI. Cavity Width Height Sheathing Framing Solar Belo w 1 _ 2 _ 3 -4 5 S E N W - Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Garage Frame - Wood Main 4.1 52 0 8 4.1 16 4 8 4.1 64 0 8 4.1 35 0 8 11 30 8 8 8 450.7 ft' 8 141.6 ft' 8 554.7 ft' 8 303.3 ft' 8 265.8 ft' 0 0 0.3 0 0 0.3 0 0 0.3 0 0 0.3 0 0.25 0.3 0 0 0 0 0 DOORS # Ornl Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 E Wood Main None .39 3 7 21 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornl ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 S 1 Vinyl Double (Clear) Yes E 2 Vinyl Double (Clear) Yes N 3 Vinyl Double (Clear) Yes N 3 Vinyl Double (Clear) Yes W 4 Vinyl Double (Clear) Yes W 4 Vinyl Double (Clear) Yes 0.32 0.3 N 0.32 0.27 N 0.32 0.3 N 0.55 0.34 N 0.32 0.3 N 0.32 0.3 N 15.0 ft' 1 ft 0 in 16.4 ft' 1 ft 0 in 16.4 it' 1 ft 0 in 41.0 ft' 10 ft 0 In 49.8 ft' 1 ft 0 in 24.9 ft' 10 ft 0 in 1 ft 0 in None 1 ft 0 in None 1 ft0 in None 1 ft 0 in None 1 ft0 in None 1 ft 0 in None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft' 380 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000387 1640.2 90.05 169.35 .1387 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.6 28.8 kBtu/hr 1 �sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 28.8 kBtu/hr cfm 0.7 1 sys#1 4/21/2020 1:24 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / ---- Supply — -- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 448 ft' Attic 212 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans:Coolin ]Thermostart:]Y Heating lX] Jan [X] Feb [[ ]] [XJ Mar Apr r[` ]l Jun Jul May [[ ]] lX1 Aug r ]J Sep Octr Oct Nov j Nov Dec Dec Venting [L 11 Jan [ ] Feb llX1l Mar Jun l Jul [ LXl LXl [[ 11 Aug [ Sep lXJ [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 68 68 68 68 68 68 68 66 66 PM Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 W 0 it 0.3 Main 4/21/2020 1:24 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 28.8 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1616 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.37B b) Solar Heat Gain Coefficient (SHGC) 7b. 0.307 14. Heating system: Capacity 28.8 c) Area 7c. 163.6 a) Split system heat pump HSPF 8.6 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: ' a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat -pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 3$t9' 5'2-7<f A-VT6 lr0- V6,eX_ City/FL Zip: FT. PIERCE, FL 34951 4/21/2020 1:24:41 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: TBD Permit Number: Fr. PIERCE, FL, 34951 MANDATORY REQUIREMENTS See individual code sections for full details. 10 SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal enveldih-- building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the parry conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended Infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. ❑R402.4.3 Fenestration air Ieakag&Vindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 4/21/2020 1:24 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door Into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heal shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filler boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be 'substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow, rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w,g. (25 Pa) across the system, including the manufacturers air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstmction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying Fluids above 105'F (41'C) or below 55•F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, Including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Healed water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and lhermosiphon ciroulalion systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 4/21/2020 1:24 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) Ej R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have LJ heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Ya inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. • R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140'F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -healing equipment installed in residential units shall meet the minimum efficiencies of Table 0404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all staled requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a lilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical EJ ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described In Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFMM/ATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 4/21/2020 1:24 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑• R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) Is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity Is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by aFlorida-registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7, 1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods Is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature Is above 507 (10*% and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8'C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the healer mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater: Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Healers and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor healed swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired.by natural or LP gas shall not have continuously burning pilot lights. 4/21/2020 1:24 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heal pumps are not required to meet this standard. ❑ R403.11 Portable spas (Mandatoryhe energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 4/21/2020 1:24 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WATERSTONE LOT-59 Builder Name: K. HOVNANIAN Street: TBD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL , 34951 Permit Number: Y U Owner: Jurisdiction: w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nipinn and Wrina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire spriinkler cover plates and walls or cell nas. a. In addition, inspection of log walls shall be In accordance with the provisions of ICG-400. 4/21/2020 1:24 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: K. HOVNANIAN Community: Lot: NA Address: TBD City: FT. PIERCE State: FL Zip: 34951 Air Leakage Test°Results Passing,results must meet either the Performance, Prescriptive,orER/Method O P,RESCRIPTIVE.METHOD-The building or dwelling unit shall betested and verified as havingan air leakage rate of not exceeding 7 air changes per hour at a pressure of•0.2: inchw.g. (50 Pascals) in Climate Zones 1. and 2. 0. PERFORMANCE or ERI METHOD -The building or, dwelling unit shalhbe tested,and,Gerified as _havingan.airleakage rate of not exceeding I.the selected'ACH(5g): value, as shown on Form'R405-2017 (Performance) or R406-20,17 (ERI), section,labeled' as infiltration; sub -section ACH50. ACH(50) specified on. Form R465-2017-Energy Calc: (Performance) or R406-2017{ERI):' L 7.000 x 60 _ 14059 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A wriften report of the results of the test shall be signed by the party conducting the test and provided to thecode official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the lest, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 4/21/2020 1:25:10 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -�- wrightsoftr Load Short Form Entire House r For: WATERSTONE LOT-59 TBD, FT. PIERCE, FL 34951 Htg Clg Outside db (°F) 43 91 Inside db(°F) 70 75 Design TD (°F) 27 16 Daily range - L Inside humidity (%) 40 50 Moisture difference (gr/lb) 11 59 Method Construction quality Fireplaces Job: Date: Apr 16, 2020 By: Infiltration Simplified Semi -tight 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A* Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btuh @47°F Latent cooling 8640 Btuh Temperature rise 27 °F Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.68 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) OWNERS SUITE 178 2811 3700 141 161 DINING AREA 147 2751 3455 138 150 GREAT ROOM 219 2849 3242 143 141 BEDROOM 4 150 1546 1629 78 71 KITCHEN 145 143 1709 7 74 OS BATH 60 60 239 3 10 OS WIC 64 1048 651 53 28 FOYER 151 978 813 49 35 MECH 17 17 389 1 17 HALL BATH 79 1034 493 52 21 BEDROOM 3 168 3852 3097 193 134 LAUNDRY 51 50 812 3 35 BEDROOM 2 147 1764 1720 89 75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-17 05:40:44 ti wrightSof * RightSuite® U niv ersal 201212.1.05 RSU02818 Page 1 �a1 C:\UsemWasonlDocumentslWrightsofl HVAC\WATERSTONELOT-59.mp Calc=MJS Front Dcorfaces: E Entire House 1607 19119 22112 960 960 Other equip loads 0 0 Equip. @ 0.95 RSM 21117 Latent cooling 10239 1 1 1 OTALS 1607 19119 31356 960 960 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-17 05:40:44 v wrightSOft' Right -Su ilegl U niv are a1201212.1.05 RSU 02818 Page C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-59.rup Cato =MJS Front Door faces: E -F- wrightsoft° Project Summary Job: Date: Apr 16, 2020 Entire House By: Project Information For: WATERSTONE LOT-59 TBD, FT. PIERCE, FL34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16698 Btuh Structure 18029 Btuh Ducts 2421 Btuh Ducts 4083 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19119 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 21117 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 9151 Btuh Ducts 1088 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1607 1607 Equipment latent load 10239 Btuh Volume (fte) 13984 13984 Air changes/hour 0.26 0.14 Equipment total load 31356 Btuh Equiv. AVF (cfm) 61 33 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A* Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btu h@47°F Latent cooling 8640 Btuh Temperature rise 27 OF Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.68 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 44 2020-Apr-1705:4geI .� Right -Suite® Universal 201212.1.05 RSU02818 �� Pee 1 C:\UsersWasonlDocumentslWrightsofl HVAC\WATERSTONE LOT-59.rup Cale =MJB Front Door !aces: E T-STAT SHALL BE WITHIN 3 FEET HORIZONTALLY OF MAIN RETURN c K HOV4ANIAN WATEK5TO N E LOT-59 ARMINA PLACE FORT PIERCE, FL 54952 4/24T020 Florida Building C MRIM SHOP STAMP REVIEW w,FIPlan tden Review Is for general compliance with the Construction Documents. Respponsibility for correctness of dimensions, details, quantities and safety PWAIOA,09PA�un OF duringfabrication Iles solely with the contractor. Business & Professional ,, Regulation r, II No Exceptions Taken Reviewed Br• Dawn Boggio-Korbelak M Rejected: BCIS Home I Login I User Registration I Not Topics I Submit Surcharge I Stats & Facts I PubliraUons I Contact Us I BCIS Site Map I Unks I Search dpr 4,z8,2o ,�_ a1 "" Product Approval USBR: Public user Product ARoroval Menu > Product or Agolication Search > Bgolicatlon Llst> Application Detall FL # FL21637-R6 Application Type Revision Code Version 2017 Application Status Approved GAaA'k *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived O Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE 2 Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) AAMA 506 " "'S'O 2Q11 AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2011 Equivalence of Product Standards Certified By FILE COPY Product Approval Method Method 1 Option A Date Submitted 03/23/2020 Date Validated 03/23/2020 Date Pending FBC Approval https://www.floridabuilding.org/pr/pr app_dtl.aspx7param=wGEVXQwtDgs9xV7TjKGeecQb2JXWyWrila/o2faFQMzcvxO°/P2bWwOJaurmQ%3d%3d 1/3 4124/2020 Florida Building Code Online Date Approved 03/26/2020 Summary of Products FL fr Model, Number or Name Description 21637.1 1620 SH 48 x 84 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16015.pdf Approved for use outside HVHZ: Yes FL21637 R6 C CAC APC 16054.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +45/-45 10/14/2021 Other: 1-C-PG50 Fin, LC-PG45 Finless/Flange Installation Instructions FL21637 R6 II 08-02998B.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AF 513861B.pdf Created by Independent Third Party: Yes 21637.2 1620 SH 52 x 75 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FQ1637 R6 C CAC APC 16016.pdf Approved for use outside HVHZ: Yes FL21637 R6 C CAC APC 16055.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +50/-50 10/14/2021 Other: LC-PG50 Installation Instructions FL21637 R6 II 08-02999B.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 5138628.p9 Created by Independent Third Party: Yes 21637.3 1620 SH 37 x 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16572.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/24/2022 Design Pressure: +50/-67 Installation Instructions Other: LC-PG50 EL21637 R6 IL 08-03042B.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514079A.pdf Created by Independent Third Party: Yes 21637.4 1620 SH 48 x 96 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16574.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/24/2022 Design Pressure: +35/-45 Installation Instructions Other: LC-PG35 FL21637 R6 II 08-03160A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514079A.pdf Created by Independent Third Party: Yes 21637.5 1620 SH Impact 38 x 75 Fin and Finless Frame, Insulated, Laminated Glass. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC(1814311820.05-106-12-RS 1620 Approved for use outside HVHZ: Yes SH(051523).pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-70 05/15/2023 Other: LC-PG50, Missile Level D, Wind Zone 3, glass was Installation Instructions bedded In Pecora 896 silicone. FL21637 R6 If 08-03454A.odf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514467A.pdf Created by Independent Third Party: Yes 21637.6 1620 SH Impact 52 x 751nsulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16230.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date https:llww .floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs9xV7TjKGeecQb2JXNyWril%2faFQMzcwO%2bVNvOJaurmQ%3d%3d 2/3 4/24/2020 Florida Building Code Online Impact Resistant: Yes 12/27/2021 Design Pressure: +50/-50 Installation Instructions Other: LC-PG50, Missile Level D, Wind Zone 3. Glass consisted FL21637 R6 II 08-03042B.pdf of 1/8" annealed exterior - spacer - 3/32" annealed / 0.090 Verified By: Luis Roberto Lomas 62514 PVB / 3/32" annealed. Glass was bedded In Pecora 896 silicone. Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 513921B.pdf Created by Independent Third Party: Yes Back Nexl Contact :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PHvacv j,,U,, ,,t:: Acceesibllity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Sectlon 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, RS., please click here. Product Approval Accepts: ® ® ® °Z=t ''®' Credit Card Safe Mips:/Avww.floridabuilding.org/pr/pr app_dtl.aspx?pamm=wGEVXQwtDgs9xV7TjKGeecQb2JXWyWd1%2faFQMzcwO%2bWwOJaurmQ%3d%3d 3/3 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville NC, 27023 434-688-0609 r1Iornas@lr1ommpe.com lrlommpe.com Manufacturer: MI Windows and Doors LLC 650 West Market Street Gratz, PA 17030 Engineering Evaluation Report Product Line: Series 1620 PVC Single Hung Window— Reinforced Non -Impact 37"x72" Report No.: 514078A Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval documents: drawing numbers 08-03159 Revision A, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. ReportNo.: G9384.01-109-47 signed by Timothy J. McGill Architectural Testing, Inc., York PA. AAMA/WDMA/CSA 101/I.S.2/A440-11 Design pressure: 367.20psf Waterpenetration resistance 7.52psf 3. Anchor calculations, report number 514078-1A, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: +50.0/-67.Opsf • Unit size: 37" x 72" • Units must be glazed per ASTM El300-04/09. • This product is not rated to be used in the HVHZ. • This product is not impact resistant and requires impact protection in wind bome debris regions. • Frame material to be rigid PVC. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document 08-03159, Revision A. Certification of Independence: Please note that 1 don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 1 of 1 1111 JN�J�S C E Ntb'�,/��% _ ir• 0,0, 5 •• W �•��TAT�w 0, '°�` ��ORIOP• Cep: Si%111��C���\ Luis R. Lomas, P.E. FL No.: 62514 01/20/2020 (Validalor / Operations Administrator) MI Windows & Doors, LLC P.O. Box 370 Gratz, PA 17030-0370 Attn: Rick Sawdey AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMA/WDMA/CSA 101/I.S.2/A440-11 LC-PG50'S40x1829(37x72)-H Negative Design Pressure = -67 psf COMPANY AND CODE CPD NO. SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED DESCRIPTION 1620 SH (FIN, FLANGE & FINLESS) FRAME SASH MI Windows & Doors, LLC 16572 (PVC)(O/X)(OG)(INS GL) 940 mm x 1829 mm 867 mm x 902 mm Code: MTL (MODIF)(REINF)(TILT) (3'1" x 6'0") (2'10" x 3'0") (ASTM) This Certification will expire March 24, 2022 and requires validation until then by continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Intertek-ATI Report No.: G9384.01-109.47 Date of Report: May 3, 2017 JGS/JTS ACP-04 (Rev. 6111) Evaluated for Certification: May 4, 2017 at A oci ted Laboratories, Inc. Authorized for Certification: May 4, 2017 AmerWn Architectural Manufacturers Association NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. S. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. S. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 AND 3 FOR DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. R04MNS REV OESCRIPiION 'AR'APPRWE� A REVISED ANCHORS 02/2]/L. R.L. 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #6 EMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME IWO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 19. ALL FASTENERS TO BE CORROSION RESISTANT. 20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,ODOPSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KS1/FU=52KS1 OR ALUMINUM 6063—T5 FU=3OKSI 1/8" THICK MINIMUM 21. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. TABLE OF CONTENTS ' SHEET NO.1 DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS 4 — 16 INSTALLATION DETAILS 17 1COMPONENTS SIGNED: O1/28/2020 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 N, v SERIES 1620 SH REINFORCED *• IMPACT — 52" X 75" NOTES —y y oRAwu: owc uo. aEv R.L. OB-03042 A 'cA� NTS 0"RE 11/3D/15 sneET1 OF 17 2 WOODFORD RO LEWISVIUE. NO 27023 I Luis R. LOmOS P.E. 4u-68a0609 manaspinomesm.mm FL N. 62514 7 FR HEI j— 52 1/8" FRAME WIDTH —I 4" MAX / 13 1/4- MAX D.C. O 5" WE GHT 4" MAX / X 4 0' 1620 SH REINFORCED RECTANGULAR EXTERIOR VIEW FINLESS & FLANGE INSTALLATION NOTES: 1. SASH SIZE. 49172'X37174- Z D.L0.:4712'XMN4' 4" MAX 13 1/ MAX O.C. 75" FRAME HEIGHT \\\ 4" MAX " FOR NUMBER OF ANCHORS REQUIRED SEE CHART #1 REINFORCED 52 1/8" FRAME WIDTH — O /// Iki9Rt r 4.0 ae.00 / X 4 0' 1620 SH REINFORCED DESIGNER EXTERIOR VIEW FINLESS & FLANGEINSTALLATION DESIGN PRESSURE RATING IMPACTRARNG ±50.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D, WIND ZONE FORADD177ONAL SIZES SEE CHART#1 52 IA' X 75" UNIT SHOWN. OTHER SIZES APPROVED AS CONGAS FRAMEAREA DOES NOT EXCEED 27.14-F1% REVISIONS OESCRIPIION MM APIRWEO REVISED ANCHORS 02/27/18 R.L. FOR NUMBER 7/8" OF ANCHORS 3/32" ANN REQUIRED SEE CHART #1 0.090" PVB BY KURARAY 1/8" ANN — 3/32" ANN TRUSEAL SPACER SYSTEM 1/2" BITE O GLAZING DETAIL SIGNED: Of/28/202( tiii WOWS LC. 6ID WEST MARKET STREET GRATZ. PA 17036-0370 '`may •LNG ENg�'�.'9ji� o SERIES 1620 SH REINFORCED*• IMPACT - 52" X 75" FINLESS & FLANGE ELEVATIONS �7�CcO+* -i .// TeiT •� �y �• TAT OF ty %�'PFS';[ORIOP G� � DRAWN: 0- NO. REv DB A NA1�E!`\`\` Lllls R. Lomas P.E. FL No.: 62514 Sai NTS MTE 11/30/16 SH F022 OF 17 LROBERTOLOMASPX. 1434VA58"OHD pOLEWISNLLE, NG 27029 430b68069 9 Nwnss@I4omespe.com 7 FR HEI 3" MAX 3 MAX 8" MAX D.C. i" ,ME 3HT AX i 3" MAX 1620 SH REINFORCED RECTANGULAR EXTERIOR VIEW RNINSTALLATION NOTES: 1. SASH SIZE: 491/2'X37114' 2. D.L.0.:47 ffi'X33314' RMSIONS �ESCRIPiION MiE APPROVE REVISED ANCHORS 02/27/18 R.L. 52 1/8" FRAME WIDTH — MAX 3" MAX 8" MAX O.C. — 3" MAX FOR NUMBER 3" MAX FOR NUMBER OF ANCHORS REQUIRED r OF ANCHORS SEE CHART #2 REQUIRED A/ SEE CHART #2 1 8" MAX O.C. / T 75" FRAME HEIGHT REINFORCED DESIGN PRESSURE RATING IMPACT RATING t60.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D, WINOZONE 3 FORADDITIONAL SIZES SEE CHARTi12 52118'X75' UNIT SHOWN. OTHER SIZES APPROVEDAS LONG AS FRAME AREA DOES NOT EXCEED 27.14' FTP V 1620 SH REINFORCED DESIGNER EXTERIOR VIEW FIN INSTALLATION F, ..iqhl 1< 7/8" — 3/32" ANN 0.090" PVB BY KURARAY 1/8" ANN 3/32" ANN TRUSEAL SPACER SYSTEM 1/2 * /2" BITE GLAZING DETAIL SIGNED: 0112812020 MI WINDOWS EST MAR ET STREET \\\\\\51Vt.L '`\'5 GRATZ, PA 17030-0370 •��(;ENSF'ps�� �'k• 0 SERIES 1620 SH REINFORCED IMPACT - 52" % 75" FIN ELEVATIONS �]Rx�/+'k= !y'G�E •CE �O• TAT OF ....Z ���Fs=.[ORIUP G\e\� M. uo. RIN 08503E032 A ',,'S/OIIIAIL 1110?\\\\ NTS °ATE 11/30/16 OF 17 Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS Y- : TO BE SET APPROVEDIN A BED OF sGXL`, �I■ VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 SILL TO BE SET IN A BED OF APPROVED SEALANT /4" MAX. HIM SPACE 1 1/4" MIN. EMBEDMENT I 7/16" MIN. EDGE DISTANCE #8 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT REV OESCRIPl10N RENSIONS MiE APPROVED A REVISED ANCHORS 02/27/18 1 R.L. /4" MAX. SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR2X BUCKINSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED IMPACT — 52" X 75" FINLESS INSTALLATION DETAILS DRAWN: Owc ND. R.L. 08-03042 SOAUZ NTS JDAB 11/30/16 SHuU4 OF 17 LROBERTOLOMASP.E. IA W000FCRDRDLEWISVILLENC2M3 4N-66M O9 dkRRRsLWWOMssp .MM SIGNED: 0112812020 ..11111I1n.. Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/4" MAX. SHIM SPACE HEAD TO BE SET IN A : : APPROVED EXTERIOR INTERIOR eeJ�yN `C`=, �I ■ SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD U & APPROVED SEALANT 1/4" MAX. F SHIM SPACE METAL STRUCTURE —� BY OTHERS VERTICAL CROSS SECTION METAL STRUCTUREINSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARITY. 2. PERIMETER AND JOINTSEALANTBYOTHERS TO BE DESIGNED INACCORDANCE WRHASTM E2112 7/16" M� EDGE DISTANCE #8 SMS OR � SELF DRILLING SCREWS METAL STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT R"SIONs REV DESCRIPTION p4iE AllR D A REVISED ANCHORS D2/27/18 I R.L. 1/4" MAX. rSHIM SPACE - INTERIOR EXTERIOR JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED IMPACT - 52" X 75" FINLESS INSTALLATION DETAILS DRAWN: pWG N0. R.L. 08-03042 SME NTS DAZE 11/30/16 5XE1i5 OF 17 L ROBERTOLOMAS P.E 1432WOODFORDRDLEWISVILLE NC27023 I30-SB&06o9 NanazL�llDmazpe.rom SIGNED: 0112812020 Luis R. Lomas P.E. FL No.: 62514 RENSIONS REV OESCRIPHDN MlE APPROVED CONCRETE/MASONRY - e A REVISEO ANCHORS 02/27/18 R.L. BY OTHERS a° - e� ° OPTIONAL IN BUCK a'• SEE NOTES 3 — 7 SHEET 1 1 1/4" MIN. _ 1/4" MAX. EMBEDMENT SHIM SPACE CONCRETE/MASONRY BACKER ROD & APPROVED �p� 1/4" MAX. BY OTHERS SEALANT oL SHIM SPACE OPTIONAL IN BUCK HEAD TO BE SET SEE NOTES 3 — 7 IN A BED OF SHEET 1 APPROVED SEALANT INTERIOR 3/16" TAPCON •, y •a �+^ p® �❑ e EXTERIOR INTERIOR I 2 �❑ ❑ • MIN. EDGE ��� a DISTANCE pf O SILL TO BE SET -, EXTERIOR BACKER ROD IN A BED OF & APPROVED APPROVED SEALANT BACKER ROD SEALANT O1=1 1/4" MAX. & APPROVED OPTIONAL 1X BUCK SEE NOTE 3 7 4q ❑ SHIM SPACE SEALANTT JAMB INSTALLATION DETAIL SHEET 1 CONCRETE/MASONRYINSTACLATION CONCRETE/MASONRY BY OTHERS -' .a , ,a SIGNED: 0112812020 ° ,� , MI DOORS,370T ��. WIN .°• 650 WEST MARKET O''PJ+�y VERTICAL CROSS SECTIONGRATZ ``st\l\\ CEN �. F CONCRETE/MASONRYINSTALLATION SERIES 1620 SH REINFORCED *• pyC�1'$ *= IMPACT - 52" X 75" — (�(1r�1c/iM�/I•z FINLESS INSTALLATION DETAILS jpT OF •y.fame,,` DR M D. N0. REV NOTES: 1. INTERIORAND EXTERIORBYOTHER$ R.GLE OB A /O111110?\`\\ OTSHOWNFO CLARRY.INISHES, NTS DATE 11/30/16 sNEFIS OF 17 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCOROANCE WITHASTME2112 L. ROSERDLEWISSP.E' Luis R. Lomas P.E. 1<32WOO-0609 RDLEWISVILLE, NC2J0T3 FL No.: 62514 0.69ti8&0609 �IlomazQlRumaspe.mm WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS I 1/4" MAX. SHIM SPACE HEAD O BE SET D OF ROVED SEALANT ieN[ �I■ VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCKINSTAIJATION NOTES.- 1. INTERIOR AND EXTERIOR FINISHES BYOTHERS, NOT SHOWN FOR CLARTTY. P. PERIMETERANDJOINTSEALAMBYOTHERSTOSE DESIGNED INACCORDANCE WITHASTM E2112 SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. HIM SPACE REV DESCRIPTON WiE PPPRWED A REVISED ANCHORS 02/2]/is R.L. 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE INTERIOR 7/16" MIN. � EDGE DISTANCE rrm B WOOD J �❑ e SCREW 0 WOOD FRAMING OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0112812020 MI WIONDOWS DOORS, LREET LC. �7j''i WEST MARKET `\`�Y\5119IIIL '`s�i•�\GENS�:giP�� GRATZ, PA 17030-0370 p,•525 *� SERIES 1620 SH REINFORCED*• IMPACT — 52" X 75" —//`�jl(�{r�1/��W� FLANGE INSTALLATION DETAILS y' STATE OF •p i:°GOR%'DV R�� UfUWN: 0- N0. REV 08 A '''SS/OI IIAl11V�G\``\ LNI$ R. Lomas P.E. FL NO.: 82514 uic NTS DP16 11/30/16 sxO66r72 OF 17 L ROBERTO LOWS RE. IA82 WOODFORDRD LEWISVILLE NC2>023 4N-68B0609 momaz@IMmazpa.rom METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/4" MAX. SHIM SPACE I All • TO BE SET IN A • OF APPROVED EXTERIOR ti'��FM�I I■ BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WIMASTM E2112 SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE ftMSIONS 06CRIPTION 041E APPROVE - REVISED ANCHORS 02/2T/18 R.L. _ 1/4" MAX. SHIM SPACE INTERIOR 7/16" MIN. /j8 EMS 0R SELF DRILLING u❑ SCREWS o TERIOR METAL STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0112812020 MI REETLC. 50WINDOWSTMAR ET STREET \\\\N\51.R11�0p�V' GRATZ, PA 17030-0370 p,•5j51 3L'� `�•'(r�/��nO•+ SERIES 1620 SH REINFORCED*• IMPACT - 52" X 75" ' FLANGE INSTALLATION DETAILS per; STATE OF �i•� 'cGORl01;•� �� DRAWN: DWO NO. REV OB A ,��/STONA 110�6```\ Luis R. LOTOS P.E. FL NO.: 62514 NTS W1E 11/30/16 sOxcE162 OF 17 L 1308EHi0 LOMAS RE 1432WDODTORDRDLEWISVILLENC27023 434-666-0609 rllomus@Nomazpe.wm REVISIONS REV DESCRIPTION M1E PPPRG D CONCRETE/MASONRY A REVISED ANCHORB 02/27/18 R.L. BY OTHERS - a° OPTIONAL 1X BUCK • - °a °'� 1 1/4" MIN. 1/4" MAX. SEE NOTES 3 — 7 EMBEDMENT _ SHIM SPACE SHEET 1 CONCRETE/MASONRY �L BY OTHERS BACKER ROD & APPROVED �� LJn 1/4' MAX. � •i SEALANT U SHIM SPACE �� OPTIONAL 1X BUCK SEE NOTES 3 — 7 HEAD TO BE SET SHEET 1 a •° " IN A BED OF INTERIOR APPROVED SEALANT 3/16" TAPCONp , ca o nel EXTERIOR INTERIOR O MIN. EDGE a DISTANCE EXTERIOR a < SILL TO BE SET BACKER ROD IN A BED OF BACKER ROD & APPROVED APPROVED SEALANT & APPROVED SEALANT SEALANT OPTIONAL IN BUCK - 0 1 /4" MAX. JAMB INSTALLATION DETAIL SEE NOTE 3 — 7 �� o SHIM SPACE CONCRETE/MASONRYINSTALLATION SHEET 1 CONCRETE/MASONRY BY OTHERS °a - SIGNED: 0112812020 .• • MI LC. VERTICAL CROSS SECTION GR WEST MARK STREET F'9ji5, ATZ, PA 0o `��rVGEN CONCRETE/MASONRY INSTALLA77ON SERIES 1620 SH REINFORCED*• p 51 *= IMPACT - 52" X 75" FLANGE INSTALLATION DETAILS 7-j TATE OF DRawN: OwD No. ,•ft�y\ NOTES: 1. INTERIOR AND E)CERIORINISHES,BYOTHERS. OB A '//AS/OIIIAIi NOT SHOWN FOR CLARITY. sO2 SCALE NTS o^TE 11 /30/16 EET9OF 17 2. PERIMETER AND JOINTSEALANTBYOTHERS TO BE DESIGNED INACCORDANCE WIMASTME2112 L RD6ERT0 LOWS R.E. Luis R. Lomas P.E. 10.32WOODFORDRDLEWISVILLGNC2T023 FL No.: 62514 4306380699 Tomaz®Itrwnaz{'e.mm WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1� ' tl SHIM SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT INTERIOR VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS NOTSHOWNFORCLARITY. 2 PERIMETERANDJOINTSEALAWBYOTHERSTOBE DESIGNED INACCORDANCE WITHASTM ER112 SILL TO BE SET IN A BED OF APPROVED SEALANT /4" MAX. IIM SPACE 1 1/4" MIN. EMBEDMENT I 7/16" MIN. EDGE DISTANCE RMSIONS REV OESCRIMON ROLE MpROVEO A REVISED ANCHORS D2/27/18 R.L. 1/4" MAX. SHIM SPACE INTERIOR #8 WOOD SCREW WOOD FRAMING n O OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD & APPROVED JAMB INSTALLATION DETAIL SEALANT WOODFRAMINGOR2XBUCKINSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED IMPACT — 52" X 75" FLANGE INSTALLATION DETAILS oRAwu: ows No. R.L. 08-03042 SCREE NTS MIE 11/30/16 JSHEFJO OF 17 L. ROBERTO LOMASP.E. SIGNED., 0112812020 Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/4" MAX. SHIM SPACE HEAD TO BE SET N A BED OF APPROVED SEALANT SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD & APPROVED SEALANT 1MAX. 9Lr� SHIM SPACE ETAL STRUCMTURE —� BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES. 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARTTY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCEWITHASTM E2112 RPASIONS DESCRIPTION DATE APPRWEO REVISED ANCHORS 02/27/18 R.L. _ 1/4" MAX. � SHIM SPACE 7/1INTERIOR 6" MIN. EDGE e DISTANCE $B SMS 01 R SELF DRILLING SCREWS �❑ 0 METAL Q� EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALLATION SIGNED. 0112812020 MI WINDOWS LC ft.LOWz 0WEST MARKET STREET N�\SI GRATZ, PA 17030-0370•y\r EN&' :'p =1k• o„6t6 `AI((t,�7/ts'tm SERIES 1620 SH REINFORCED IMPACT — 52" X 75" FLANGE INSTALLATION DETAILS; STATE OF •{�,` ORM DRAWN : Dwc uD. REV OB 42 Olt A XX7781ONAIlE�X��� Luis R. LORIOS P.E. FL No.: 62514 sx0E :rxE NTS wiE 11/30/16 OF 17 LROBERTOLOWSHRE. 1432Y/000FORDROLSVIISVILLS,NC2)0W d 4-696-0609 111mnas@Irlomaspe.mm CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED SEALANT �a 1/4" MAX. 71NABEDOF SHIM SPACE HEAD BE SET , ,,,,,,, APPROVED SEALANT INTERIOR SILL TO BE SET BACKER ROD IN A B BED OF & APPROVED APPROVED SEALANT SEALANT O 1/4" MAX. O�SHIM OPTIONAL 1X BUCK SEE NOTE 3 7 o SPACE 4q SHEET 1 CONCRETE/MASONRY BY OTHERS Qa • n e .. VERTICAL CROSS SECTION CONCRETEAM SONRY INSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARTTY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WITH ASTM E2112 RNSIONS OESCRIPRON 64iE MpROVEO REVISED ANCHORS 02/27/18 R.L. 1 1/4- MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK " SEE NOTES 3 — 7 1/4" MAX. SHEET 1 .° SHIM SPACE INTERIOR 3/16" TAPCON .cam I e 2 �❑ o MIN. D EDGE D DISTANCE EXTERIOR a BACKER ROD & APPROVED JAMB INSTALLATION DETAIL SEALANT CONCRETEMASONRY INSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED IMPACT — 52" X 75" FLANGE INSTALLATION DETAILS ORRWN: OWG N0. REV R.L. 08-03042 A SCRIP NTS ' 11/30/16 1 S80712 OF 17 SIGNED: 0112812020 Luis R. Lomas P.E. FL No.: 62514 APPROVED SEALANT BEHIND FIN #6 WOOD SCREW 3/8" MIN EDGE DISTANCE J�x`�-, IGI ■ 3/8" MIN EDGE DISTANCE 6 WOOD SCREW APPROVED EMBEDME SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR2X BUCK INSTALLATION NOTES. 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETERANDJOINTSEALAMTBYOTHERSTOBE DESIGNED IN ACCORDANCE WON A STM E2112 WOOD FRAMING BY OTHERS _ 1/4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS RM510N5 DESCRIPTION W.iE I APPRWEO REVISED ANCHORS 02/27/18 1 R.L. _ 1/4" MAX SHIM SPACE WOOD FRAMING \ Ul BY OTHERSDINTERIOR SCREW 1 1/2• MIN. EMBEDMENT pp g lull APPROVED 0 SEALANT BEHIND FIN 3/8" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING 0172X BUCKINSTALLATION SIGNED: 0112812020 N11 WI�NDOWSWESTMKET &RDOORREETLC. jz \�llit.L "9S GRATZ, PA 17030-0370 `y•y,r Ft'6, p•,5�57/T:scO��*_ SERIES 1620 SH REINFORCED*• IMPACT — 82" % FIN WITH J CHANNEL INSTALLATION DETAILS ATI Z-7 B �C �p TAT OF W` 0, • All p ORIO" )UMNWG N0. REV 08 3042 A pA/S�pNA11�N\��� S E — s0 EET NTS 11/30/16 13 OF 17 LDIS R. Lomas P.E. FL NO.: 62514 LROBERTOLOMASPE. iG92WOODWRDRDLEWISWUE;?102023 A%d "W9 `llamas@lndmaspd.cam BEHIND FIN #6 SMS OR SELF DRILLING SCREW 3/8" MIN EDGE DISTANCE C�j a�MLY� '.■ METAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX r SHIM SPACE 3/e" MIN EDGE DISTANCE #6 SMS OR SELF DRILLING METAL STRUCTURE BY OTHERS SCREW VERTICAL CROSS SECTION APPROVED METALSTRUCTUREINSTALLAT/ON SEALANT BEHIND FIN NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWN FOR CLARITY. 2. PER/METERANDJO/NTSEALANTSYOTHERSTOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 RVASIONS D6CRIPVON N.iE APPROVED REVISED ANCHORS 02/2T/18 R.L. _ r1/4" MAX SHIM SPACE METAL STRUCTURE —� BY OTHERS N ERIOR SMS OR SELF DRILLING SCREW y APPROVED SEALANT BEHIND FIN EXTERIOR 3/8" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALIATION SIGNED: 0112812020 Nib LC. lL7o�''Ai 650 STREET 0 WEST MARKET \```X\5 Ft. GRATZ, PA 17030-0370 y .%CENy+�•Pji #_ SERIES 1620 SH REINFORCED*.�%{ IMPACT 5S X !�(rL�•10�61/f FIN WITH J CHANNEL INSTALLATION DETAILS E ATI a ' S E �A • $TAT OP ��"F:•'�[ORIOe;•�?w�� DRAwN: nxc N0. REv 08 42 A ',,7ssj/DjNA;IE�G`�� Luis R. LOTO$ P.E. FL NO.: 62514 iCLLE NTS w.*L 11 /30/16 sOx �014 OF 17 L ROBERTO LOMASP.E 1<32 WOOOFORO RO LEWISVILLE. NL 2T023 GSQEB8L609 Nwnasplrlanupe.mm APPROVED SEALANT BEHIND FIN #6 WOOD SCREW 3/8" MIN EDGE DISTANCE . •. I r1 AI 3/8" MIN EDGE DISTANCE #6 WOOD SCREW APPROVED —---— SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: L INTERIORANDEKTERIORFMISHESBYOTHERS. NOTSHOWNFORCLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCEWITHASTM E2112 WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS RMSous o6scRlPnox natc APPx D REVISED ANCHORS 02/27/I6 IRL. _ 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS' //6 WOOD SCREW INTERIOR 1 1/2" ra o MIN. EMBEDMENT pp APPROVED �❑ SEALANT b— BEHIND FIN 3/8" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCKINSTALLA71ON SIGNED: 0112812020 tiii ID DOWS DOORREET LC. Ill. 6 WESTM&R S L0�//' GRATZ. PA 17030-0370•yNGENs�"9iP�� 0 6 *' SERIES 1620 SH REINFORCED*• IMPACT — 52N X FIN INSTALLATION DETAILS I lu �q] • TAT OF }tb DRAWN: MG 40. R6v 08 42 A '',AS/o111�111�?\``\ Luis R. LOTos P.E. iCAL6 NTS °"� 11/30/16 5"�075 OF 17 LROBERTOLOWSP.E fm W000FORDROLEWISVII. NC27028 0. -68& 09 Aomas�lrbmasoe.rom FL No.; 62514 APPROVED SEALANT BEHIND FIN #6 SMS OR SELF DRILLING SCREW 3/8" MIN EDGE DISTANCE 3/8" MIN EDGE DISTANCE #6 SMS OR c SELF DRILUNG SCREW VERTICAL CROSS SECTION APPROVED METAL STRUCTURE INSTALLATION SEALANT BEHIND FIN NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETERAND JOINTSEALANTBY OTHERS TO BE DESIGNED INACCORDANCEYMASTM E2112 METAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE /4" MAX SHIM SPACE METAL STRUCTURE BY OTHERS RENSIONS DMCRI"ON ATE I PROVED REVISED ANCHORS 02/27/18 1 R.L. _ 1/4" MAX SHIM SPACE METAL STRUCTURE BY OTHERS _ INTERIOR #6 SMS OR SELF DRILLING SCREW APPROVED SEA ANT BEHIND FIN 3/8" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 01/28/2020 MI WINDOWS LC. 0T ET STREET 650 MARKET E GRATZ, PA 17030-0370 ` yy\G NoF9iP�i *• 5 +1'� SERIES 162D SH REINFORCED IMPACT — 52" X 75" FIN INSTALLATION DETAILS gip: STATE OF •yt� owc uo. REv 08 A 1oIIlAl110?\\\\ LDIS R. Lamas P.E. FL NO.: 62514 503L042 16 OF 17 NTS °9iE 11/30/16 L.ROSERTOLOMASP.E 1C92WOODFORDRDLEWISVILLENC21029 <U4E 609 rlkmesidlrWnssPO.mm 01 3 3/16" o 2 5/16" HEAD/JAMB FINLESS EXTRUDED PVC (V-1008) 3 1. 3333/16" 6 HEAD/JAMB FIN INSTALLATION EXTRUDED PVC (V-1007) 3 1/4" — 0 1/ SILL FINLESS EXTRUDED PVC (V.1013) I-- 3 1/4" -i '2�r_ B. SILL FIN INSTALLATION EXTRUDED PVC (V-1012) 3/16" o¢� 2 13/16 LJ HEAD/JAMB WITH FLANGE EXTRUDED PVC (114010) 3 1/4" 2 13/16" H-1-DgpOD4 HEAD/JAMB WITH FLANGE EXTRUDED PVC (VE-000025) 1 1/4" 3 13/16" r=1L� JJl—I0� Qglrp4 3 5/6" 1 3/4" L BOTTOM SASH/STILE wrAnnnneQ cm11A107AI I ATInA1 eB l MAI IAICTAI l ATlnA1 EXTRUDEDPVC(V-670) H—� 1 1/8" 7/8" STILES REINFORCEMENT ALUMINUM 6063-T5 (M-2266) WITH J-CHANNEL EXTRUDED PVC (P-1011) nZpp'�! nnzlo MEETING RAIL REINFORCEMENT ALUMINUM 6063-TS (AE-000162) 15/16" J_rF 1/2" LOCK RAIL REINFORCEMENT ALUMINUM 6063-T5 (M-2115) RENSIONS RN pESCPIPiION I pAIE APPRO ' A REVISED ANCHORS 02/2]/10 R.L. SILL WITH FLANGE EXTRUDED PVC (V.1015) 2 5/8" SILL WITH FLANGE EXTRUDED PVC (VE-000021) 1 1/4' b� �1❑I��1�f 2 3/16" O aLJ� MEETING RAIL EXTRUDED PVC (V-1016) MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED IMPACT — 52" X 75" COMPONENTS — 1 1/2" 1 3/4" �❑ BOTTOM SASH?OP RAIL EXTRUDED PVC (V-675) 1 3/4 4" BOTTOM SASH/BOTTOM RAIL EXTRUDED PVC (V.672) R.L. 1 08-03042 SME HIS -E 11/30/16 S-EU17 OF 17 L ROBERTOLOMASP.E. W2W000FORO RO LEWISVILLE. Na2702S 434-62Ad699 rllmnss@IAwnazpe.rom 13/11 6., GLAZING IN�GG BEAD RIGID PVC (V-676) SIGNED: 0112812020 Luis R. Lomas P.E. FL No.: 62514 4/24/2020 Florida Building C r� ' ' SHOP STAMP REVIEW Iutn/Plan taen Review Is for general compliance with the Construction Documents. Responsibillty for correctness of dimensions, details, quantities and safety OF du ring fabrication lies solely with the contractor. : Professional , , Regulation DI No Exceptions Taken Reviewed By: Dawn B09910-Korbelak ClBusiness Rejected: BCIS Home I Login I User Registration I Hot Topics I Submit Surcharge Stats & Facts I Publications I contact us I BCIS Site Map I Links I Search I 54/28/20 !1 P,�IProduct Approvaldb'au'lUSBR: Public User Product Agoroval Menu > PrctivR or Agolicatlan Search > Application List> Application Oe[all FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory FBl'S332=R5 Revision 2017 Approved 0 MI Windows and Doors 650 West Market Street Gratz, PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Exterior Doors Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received c�,/�'y "VISION ISION Florida Engineer or Architect Name who developed the Luis Roberto Lomas `y Evaluation Report Florida License PE-62514 Quality Assurance Entity American Architectural Manufacturers Association Quality Assurance Contract Expiration Date 12/31/2020 Validated By Steven M. Urich, PE RJ Validation Checklist - Hardcopy Received Certificate of Independence FL15332 R5 COI FLCOI.p>f FILE COPY Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D hftps://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtH8572gvdWldku3BmvbCOTyMW9wxhwpTl FkhOfDHBW5w°/a3d%3d 1/4 4/24/2020 Florida Building Cade Online Date Submitted 06/18/2019 Date Validated 06/19/2019 Date Pending FBC Approval 06/24/2019 Date Approved 08/13/2019 Summary of Products FL # I Model, Number or Name Description 15332.1 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD OXO 145-3/4"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5332 R5 11 08-00500E.gdt Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLI5332 RS AE 5108070.pd1 PRESSURE RATINGS Created by Independent Third Party: Yes 15332.2 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD OX, XO, XX 96"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5332 R5 II 08-00498E.gpj Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLI5332 R5 AE 510805D.pdf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.3 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED OXO 145-3/4"x96" REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 RS iI 08-02248C.pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLI5332 R5 AE 512968C.pdf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.4 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED OX, XO, XX 96"x96" REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5332 R5 II 08-02249C.odf Approved for use outside HVHZ: Yes Veri0ed By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 RS AE 512969C.odf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.5 SERIES 420 ALUMINUM SGD SERIES 420 ALUMINUM SGD REINFORCED XXX 143"x96" REINFORCED . Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 RS II 08-02250C.1ad_f Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 RS AE 512970C.odf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.6 Series 420 OXXX SGD Reinforced Series 420 OXXX SGD Reinforced non impact (Interior Reinforcement) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R5 II FL16054 R6 II 08-01830D.pdff Approved for use outside HVHZ: Yes Verified By: Luis R. Lomas, PE PE-62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to approval document for design pressure FLI5332 RS AE FL16054 R6 AE 512517D.gd ratings. Created by Independent Third Party: Yes 15332.7 Series 420 OXXX SGD Reinforced Series 420 OXXX SGD Reinforced Non Impact (Interior and Exterior Reinforcement) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R5 II FL16054 R6 If 08-01831D.&I Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: No Created by Independent Third Party: Yes Evaluation Reports https:/Amw.fladdabuilding.orglpripr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWldku3BmvbCOTyMW9mhwpTIFkhOfDHBW5w%3d%3d 2/4 412412020 Florida Building Code Online Design Pressure: N/A FLI5332 RS AF FL16054 R6 AE 512518D.PAE Other: Refer to approval document for design pressure ratings Created by Independent Third Party: Yes 15332.8 SERIES 420 REINFORCED ALUMINUM SERIES 420 REINFORCED ALUMINUM SGD OXO 146"x96" SGD Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 RS If 08-00501E.pdf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 RS AE 510808D.pdf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.9 SERIES 420 REINFORCED ALUMINUM SERIES 420 REINFORCED ALUMINUM SGD OX, XO, XX 96"x96" SGD Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5332 RS II 08-00499F.W Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLI5332 RS AE 510806D.Pdf PRESSURE RATINGS Created by Independent Third Party: Yes 15332.10 SERIES 430/440 ALUMINUM SGD SERIES 430/440 ALUMINUM SGD XXX 143"x80" NON - REINFORCED Limits of Use Installation Instructions Approved for use in HVHZ: No FLI5332 R5 fI 08-00502E.p-dif Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FLI5332 R5 AE 510809D.0df PRESSURE RATINGS Created by Independent Third Party: Yes 15332.11 SERIES 430/440 REINFORCED SERIES 430/440 REINFORCED ALUMINUM SGD XXX 143"x96" ALUMINUM SGD Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R5 If 08-00503E.PILf Approved for use outside HVHZ: Yes Verified By: Luis Roberto Lomas 62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: REFER TO APPROVAL DOCUMENT FOR DESIGN FL15332 R5 AE 510810D.pAt PRESSURE RATINGS Created by Independent Third Party: Yes 15332.12 Series 440 OXXX SGD Reinforced Series 440 OXXX SGD Reinforced Non Impact (Interior and Exterior Reinforcement) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 R5 It FL16054 R6 II 08-01885D.gQf Approved for use outside HVHZ: Yes Verified By: Luis R. Lomas, PE PE-62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to approval document for design pressure ratings FLI5332 R5 AE FL16054 R6 AE 512577D.pdf Created by Independent Third Party: Yes 15332.13 Series 440 OXXX SGD Reinforced Series 440 OXXX SGD Reinforced Nan Impact (Interior Reinforcement) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15332 IS If FL16054 R6 II 08-01886D pol Approved for use outside HVHZ: Yes Verified By: Luis R. Lomas, PE PE-62514 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to approval document for design pressure ratings FL15332 R5 AE FL16054 R6 AE 512S78D.Wff ' Created by Independent Third Party: Yes Conte ❑ :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State or Florida is an AA/EEO employee SS0.YSl9ht 2007-2013 State of Florida.:: Ipr vacv Statement:: Amesdifluj N Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Sechon 455375(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Depa rtment with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.s., please click berg,. Product Approval Accepts: https:/Aw .flaridabuilding.org/prlpr app_dtl.aspVparam=wGEVXQwtDgtH8572gvdWldku3BmvbCOTyMW9wxhwpTl FkhOfDHBWSw%3d%3d 314 4124/2020 Florida Building Code Online Credit Card Safe https:IAw .floridabuilding.org/prlpr app_dtl.aspx7param=wGEVXQwtDgtH8572gvdWldku3BmvbCOTyMWgmhwpTlFkhOfDHBW5w%3d%3d 4/4 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 rllomas@lrlomaspe.00m Manufacturer: MI Windows and Doors LLC 650 West Market Street Gratz, PA 17030 Product Line: Series 420 Aluminum SGD 96"x80 Non -Reinforced Engineering Evaluation Report Report No.: 510805D Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-00498, Revision E, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: CCLI-12-119 signed by Wesley Wilson Construction Consulting Laboratory International, Carrollton, TX AAMANUDMIA/CSA 101/I.S.2/A440-08 Design pressure: t40.Opsf Water penetration resistance 6.Opsf 3. Anchor calculations, report number 510805-1 C and 510805-2, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: Refer to approval document. • Maximum panel size: 48 %" x 79" • Approved configurations: OX, XO, XX, XP, PX, XIP and PIX • Units must be glazed per ASTM E1300-04/09, with safety glazing. • This product is not rated to be used in the HVHZ. • This product is not impact resistant and requires impact protection in wind bome debris regions. • Frame material to be aluminum 6063-T5. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-00498, Revision E. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed produc(s). 1 of 1 V •v\CENSF•gcf'�`i *0 51 •*= •4TATE OF %O'°FS .'c�OR10P •G��e�: ONAL1����`� Luis R. Lomas, P.E. FL No.: 62514 06/20/2017 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. FRAME MATERIAL• EXTRUDED ALUMINUM 6063—T5. S. UNITS MUST BE GLAZED PER ASTM E13DO-04/09, WITH SAFETY GLASS. 7. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. B. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. DOOR ASSEMBLIES INSTALLED WHERE OVERHANG RATIO IS EQUAL OR GREATER THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE. OVERHANG RATIO = OVERHANG LENGTH/OVERHANG HEIGHT 10. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 11. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 12. FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILUNG SCREWS WITH SUFFICIENT LENGTH TD ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 13. ALL FASTENERS TO BE CORROSION RESISTANT. 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-9D, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM 15. APPROVED CONFIGURATIONS: OX. XO, XX, XP, PX, KIP, PIX. TABLE OF CONTENTS SHEET wo.1 DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS 4 — 10 INSTALLATION DETAILS RDASI00 DESCRIP v SATE I AG]R D ADDED CHARTS 03/DS/12 R.L REVISED PER NEW TESTING 10/29/13 R.L. ADDED RANGE AND FIN INSTALLATIONS 12/06/13 R.L REVISED INSTALLATION DETAILS 07/30/15 ILL REVISED INSTALLATION DETAILS 06/20/17 R.L. SIGNED; 0612012017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ. PA 17030 SERIES 420 SGD 98" X 80" NON —REINFORCED NOTES TUTS °A� D2/23/09 08 sxaT 1 B OF 10 E '�Xijj1ONAj1E����` L ROBERTO LOADS RE Luis R. Lomas P.E. 14V WOODFORD AD LEWISVIL14 NC27023 FL No.: 62514 4,14SHH-0609 Nomas(ilrlmresre.mm 96' MAX FRAME WIDTH (2) ANCHORS PER LOCATION SEE CHART #3 FOR NUMBER OF LOCATIONS REQUIRED 17" 6• I - O.C.MAX 6" MAX 6' MAX 17" MAX O.C. BO" I MAX FRAME HEIGHT L 6" MAX SERIES 420 SGD EXTERIOR VIEW DESIGN PRESSURE RA1 IMPACT RATING 140.OPSF NONE SEE CHARTS #1 AND #2 FOR OTHER UNITS RATINGS NOTES: 1. MAXIMUM PANEL SIZE:48 1,2'x 79' 2. MAXIMUMD.L.O.:"W'x745'8' IA III) FLAT MOUNTED RANDLE SET(PART#99-04145) LOCATED 3831V ON CENTER FROM PANEL BOTTOM 1 RINSIONS REV DEXA LION Dx E MPlVMD A ADDED CHAR15 03/05/12 R.L B REVISED PER NEW TESTING 10/29/13 R.L C ADDED FLANGE MD FIN INSTALLATIONS 12/06/13 R.L. D REVISED INSTALLATION DETAILS 07/30/15 R.L E REVISED INSTALLATION DETAILS 06/20/17 RI CHART#1 WHERE WATER INFILTRATION RESISTANCEIS REQUIRED. SEE NOTE9 SHEET I Design pressure chart (ps0 Frame 6hgla net and Total Frame WCth (in) Height (h) 30.0 60.00 26.0 72.00 i420 1 BA00 48.0 1 96.00 Pos I Nag I PCs Nag I Pas I Neg I PCs I Neg B0.0 4D.0 I 55.1 I 40.0 48.2 I 1.0 I 43.4 I 40.0 I 40.0 CHART#2 WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. SEENOTE 9 SHEET I Design pressure chart (psQ Frame Single Penal and Total Freve Wolin(h) Flight (in) 30.0 60.00 36.0 72.00 42.0 84.00 1 48.0 96.00 PCs Neg Pos I Net, Pos Neg I Pas I Neg B0.0 55.1 55.1 4B.2 1 46.2 43.4 43.4 1 40.0 1 10.0 CHART#8 Number of anchor foes bans required Frame Single Panel and Total Frane Wdth(h) Height 80.0 86.0 42.0 (in) 60.0 12.0 84.0 95.0 96.0 H65 I Jamb I H8S I Jamb I HBS Jamb I H65 I Jamb 80.0 4 1 5 1 5 1 5 1 6 5 1 6 1 5 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ. PA 17030 SERIES 420 SGD 96" X 80" NON -REINFORCED ELEVATION 1 F.A. 08-GD49B 11 's ' NTS 1" 02/23/09 s"s 2 OF 10 SIGNED: 0612012017 Luis R. Lomas P.E. FL No.: 62514 6" MAX 6" MAX 17" MAX O.C. 80' T—' MAX FRAME HEIGHT L. 6" MAX 96" MAX FRAME WIDTH (1) ANCHOR PER LOCATION AT HEAD & JAMBS SEE CHART #4 FOR NUMBER OF LOCATIONS REQUIRED 17" MAX O.C. 6" MAX CHART#4 Number a/eneher I eeefienvequlretl shale PenM end T.Wl Al"M(m) Re,re H 8a0 no d1.0 48.0 (h)h) 60.0 720 Bd.O 86.0 H65 Jemb I H65 IJemb H65 Jamb H65 JemD 80.01 4 5 1 5 1 5 1 a 1 5 1 0 1 5 SERIES 420 SGD EXTERIOR VIEW (2) ANCHORS PER LOCATION AT SILL DESIGNPRESSURERATING IMPACTRARNG SEE CHART #4 FOR NUMBER OF 340.OPSF NONE LOCATIONS REQUIRED SEE CHARTS #1 AND #2 SHEET2 FOR OTHER UNITS RATINGS NOTES: 1. MAXIMUM PANEL SIZE: 48 1&'x 79' 2. MAXIMUMD.LO.:445'8'x74548" G\IO)ae-ltlr"•1•.Ilyla].L]i�a(ILIaF.'FF3K6FF]1Sy913•IsFIHLI[H.[Ny.113atla]41JIay�•Z•llC].1� aEnsiOis w D6CFIPIIoa DAW I MPRg A ADDED CHARTS 03/05/12 R.L. B REVISED PER NEW TESTING 10/29/13 R.L C ADDED RANGE AND DN INSTAUATIONS 12/05/13 R.L D REVISED INSTALLATION DETAILS 07/30/15 R.L. E REVISED INSTALLATION DETAILS 06/20/17 R.L MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 420 SGD 96" X 80" NON —REINFORCED FIN ELEVATION DaewN: OND NO. F.A. 08-00496 ' NTS a`TE 02/23/09 IsNM3 OF L ROB£RTOLOMAS P.E. 1432 WOODPoRD RD L£WISVIL .. NC 27023 434-688-0609 Tomas@Irlamaspo.rom SIGNED: 0612012017 Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS #10 WOOD SCREW #10 WOOD SCREW I WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 3/8" MIN. 1/4" MAX. SHIM SPACE EXTERIOR II II II II INTERIOR NOTES.- 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE MTHASTM E2112 1 3/8" MIN. EMBEDMENT _f­- 1/2" MIN. EDGE DISTANCE SET IN APPROVED SEALANT #10 WOOD SCREW MIN. AENT MIN. STANCE WOOD FRAMING OR 2X BUCK BY OTHERS aEN510N5 DMRMON am olF ADDED CHARTS 03/DS/12 R.L REVISED PER NEW TESTING 1D/29/13 R.L ADDED FLANGE AND FIN INSTALLATIONS 12/06/13 R.L REVISED INSTALLATION DETAILS 07/3D/15 R.L REVISED INSfAULA1019 DETAILS 06/20/17 R.L. 1/4" MAX. r SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0612012017 MI WINDOWS AND DOORS LLC 650 MARKETWEST STREET R ATZ. PA SERIES 420 SGD*• 96" X 80" NON -REINFORCED FRAME INSTALLATION DETAILS spy oaAwN: VN0 No. F.A. 08-OD498 E ' NTS I wre 02/23/09 sN� 4 OF 10 momas®mariaspemm I L NoL:omas P.E.ODRD!WlFs 625142 WOOD£E a669 METAL STRUCTURE BY OTHERS #10 SMS OR SELF DRILLING SCREW METAL STRUCTURE BY OTHERS 1/2" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE #ID SMS OR SELF DRILLING SCREW EXTERIOR II II II II INTERIOR VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS, NOTSHOWNFORCLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 _L TO BE SET IN BED OF 'PROVED SEALANT 1/2" MIN. EDGE DISTANCE 1/2" MIN. EDGE DISTANCE I #10 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE RMION6 RN DIRFNON MTE APPROVED A ADDED CHARTS 03/05/12 R.L B REVISED PER NEW TESTING 10/29/13 R.L. C ADDED TLANGE AND Fill INSTALWIONS 12/06/13 R.L D REVISED INSTAWITION DETAILS 07/3D/15 R.L E REVISED INSTALLATION DETAILS 06/20/17 R.L JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ. PA 17D30 SERIES 420 SGD 96" X 80" NON —REINFORCED FRAME INSTALLATION DETAILS F.A. 1 08-00498 ' NTS 02/23/09 ISHMS OFT-0 L RCBERTO LCMASP.E f0.32 W00DF0RDRDLEWISVlUE NC2R123 lJddH80609 rllomaz@NomaspecwR SIGNED: 0612012017 Luis R. Lomas P.E. FL No.: 62514 Rensroxs 1 1/2" MIN 1' MIN. ��� REV oMCRm . WTE MPRWED SEPARATION EDGE DISTANCE A ADDED CHARTS 03/05/12 R.L B REVISED PER NEW TESTING 10/29/13 R.L 9• a _ C ADDED FLANGE AND FIN INSTALLATIONS 12/06/13 R.L a 1 1/4" MIN. '. •a• a;<� EMBEDMENT D REVISED INSTALLATION DETAILS D7/30/15 R.L CONCRETE/ .-a a., A; I 1 1/4" MIN. EMBEDMENT E REVISED INSTALLATION DETAILS 06/20/17 R.L. MASONRY 1IM MAX' BY OTHERS SHIM SPACE OPTIONAL ix BUCK 1/4" MAX. •.a TO BE 1' ' SHIM SPACE PROPERLY MIN. INTERIOR SECURED EDGE SEE NOTE 3 DISTANCE SHEET 1 3/16" TAPCON MIN N w r - ❑ EXTERIOR INTERIOR SEPARATION 4==�u 7' SILL TO BE SET IN R. A BED OF APPROVED SEALANT 3/16" TAPCON ' 3/16" TAPCON EXTERIOR CONCRETE/MASONRY BY OTHERS MASONRY/ OPTIONAL 1X BUCK JAMB INSTALLATION DETAIL CONCRETE TO BE PROPERLY CONCRETEIMASONRYINSTALLATION BY OTHERS SECURED SEE NOTE 3 SHEET 1 A " 1 1/4" MIN. NOTES. EMBEDMENT 1.INTERIORANDEXMRIORFINISHESBYOTHERS, a,• v NOTSHOWNFORCLARITY. ' p" a 2.PERIMETERANDJOINTSEALANTBYOTHERSTOBE a DESIGNED INACCORDANCE MTHASTM E2112 SIGNED: 0612012017 2 7/8" MIN _ 1' MIN. MI WINDOWS AND DOORS LLC \�711LIIITIfU SEPARATION EDGE DISTANCE 650 WEGRAST MARKET PA 0STREET i VERTICAL CROSS SECTION CONCRETE/MASONRYINSTALLATION SERIES 420 SGD*• ``\y�\?�CE�.1J,4� F 0 6 1t- 7,t',[rtC� 96" X BO" NON —REINFORCED — (�,.f6��' FRAME INSTALLATION DETAILS p TA7p OF •,l" DRAWN wc NO. '0 �ORM"'? GNIREV S OB B E ''/OA\` SNTS 02/23/09 sM6OF 10 //Nl1� L ROBERTO LOWS P.E Luls R. Lomas P.E. IA32 WOODFORDRDl SVMLENC2N23 FL No.: 62514 13C-6B8-0609 rllomaz@)rbmaspe.com AW WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 3/8" MIN EMBEDMENT 1/4" MAX J SHIM SPACE #10 WOOD SCREW EXTERIOR II II II II INTERIOR 1E SET IN APPROVED SEALANT #10 WOOD SCREW I WOOD FRAMING OR 2X BUCK BY OTHERS MIN. AENT MIN. cwc OSTANCE VERTICAL CROSS SECTION WOOD FRAMING 0172 BUCKINSTALLA7I0N NOTES: L INTERIORAND EXTERIOR FINISHES. BYOTHERS. NOTSHOWNFORCLARRY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOSE DESIGNED INACCORDANCE WITHASTM E2112 1 3/8" MIN. EMBEDMENT T_ 1/2" MIN. EDGE DISTANCE #10 WOOD SCREWS WOOD FRAMING OR 2X BUCK BY OTHERS 1/4" MAX. SHIM SPACE RMSIDus 0MCRIpOON am MpR ADDED CHARTS 03/05/12 R.L. REVISED PER NEW TESNNG 10/29/13 R.L. ADDED FLANGE AND FIN INSTALLATIONS 12/06/13 R.L. REVISED INSTALLATDN DETAILS 07/3D/15 R.L. REVISED INSTALLATION DETAILS 06/20/17 R.L. INTERIOR L. EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0612012017 MI WINDOWS DOORS LLC WEST MARKET STREET 650E GRATZ. PA 17030 `\\\�\5111�II ` r,.��G ENSF;9iP *! 0 6�1�t'co+*.: SERIES 420 SGD 96" X 80" NON —REINFORCED +/E ' FLANGE INSTALLATION DETAILSTAT • OF tp� ���'1F•'c[OR10Q:•�'�� DRAWN: Dxc uo. Rcv F.A.so� OB E/DNA lIl\NG\`` Luis R. Lomas P.E. FL No.: 82514 SD0498 OF 10 NTS °A� 02/23/09 LROBERTOLOMASP.E 1412W DFORO ROL£WISWLLE. NC2= 49CdB60609 rllvmas[dlrbmaspa.mm 1/2" MIN. EDGE DISTANCE METAL STRUCTURE 4 BY OTHERS 1 / " MAX SHIM SPACE #10 SMS OR SELF DRILLING SCREW I METAL STRUCTURE BY OTHERS #10 SMS OR SELF DRILLING SCREW EXTERIOR LUJ LUII INTERIOR TILL TO BE SET IN BED OF APPROVED SEALANT 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS. NOT SHOWN FOR CLARITY. P. PERIMETER AND JOINT SEALANTBY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 RUVONS DESCRI 0R wlE MpRWEo ADDED CHARTS 03/05/12 R.L REVISED PER NEW TESDNG 10/29/13 ILL ADDED FLANGE AND FIN INSTALIATIONS 12/06/13 ILL REVISED INSTALLAPDN DETAILS 07/30/15 ILL REVISED INSTAl1ADON DETAILS 06/2D/17 ILL _ 1/4" MAX. SHIM SPACE 1/1 MIN. INTERIOR EDGE DISTANCE #10 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS EXTERIOR JAMB INSTALLATION DETAIL METAL STRUCTUREINSTALLATION SIGNED: 06/20/2017 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ. PA 17030 ` y SERIES 420 SGD 96" X 80" N014—REINFORCED _�*• ,a FLANGE INSTALLATION DETAILS Dxn ND. REV �F 08—D0498 NTS IDATE D2/23/D9 SHEETS OF 10 Luis R. Lomas P.E. FL No.: 62514 REYSNNS 1 1/2" MIN 1MIN. REV Oc R"ON IurE ♦PPRMD SEPARATION EDGE DISTANCE I A ADDED CHARTS 03/05/12 R.L. B REVISED PER NEW TESTING 10/29/13 R.L. _T C ADDED FIANCE AND FIN INSTALLATIONS 12/06/13 R.L 1 1/4" MIN. D REVISED INSTALLATION DETAILS 07/3D/15 R.L CONCRETE/ EMBEDM_�_ ENT EM 4*BEDMIN E REVISED INSTALLATION DETAILS 06/20/17 R.L. ENT MASONRY 1/4' MAX. BY OTHERS F SHIM SPACE OPTIONAL a .. 1/4° MAX. 1X BUCK SHIM SPACE TO BE 1. a PROPERLY MIN '. •' INTERIOR SECURED SEE NOTE 3 EDGE 'e SHEET 1 DISTANCE 3/16" TAPCON ❑ ❑ b._•v EXTERIOR INTERIOR MIN ❑ ❑ SEPARATION a 3/16" TAPCON EXTERIOR SILL TO BE SET IN A BED OF CONCRETE/MASONRY 3/16" TAPCON APPROVED SEALANT BY OTHERS JAMB INSTALLATION DETAIL OPTIONAL 1X BUCK CONCRETE/MASONRYINSTALLATION TO BE PROPERLY MASONRY/ SECURED CONCRETE SEE NOTE 3 SHEET 1 BY OTHERS NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINTSEALANTBYOTHERS TO BE ` ° 4 1 1/4" MIN. DESIGNED INACCORDANCE WITHASTME2112 EMBEDMENT SIGNED: 0612012017 a Ml WlNDO650 WEST ANDDOORS STREET LLC `\\\`\51LnlIIt lO/'tI/* GRATZ. PA 17030 '`may °AGENy+' 9s�� 2 7/8° MIN _ 1° MIN. _� •�. A• SEPARATION EDGE DISTANCE SERIES 420 SGD- *�• �!D 51/C�'= 96" X 80" NON —REINFORCED .//q� p^ VERTICAL CROSS SECTION FLANGE INSTALLATION DETAILS Zp • TAT DF W: CONCRETEIMASONRYINSTALLATION ORAwN: MG NO. REV �i°�°•:20R\D4;•��� °^•y_ NTS �M 02/23/09 08 �Om9E OF 1D E/)/ ONA11EaG���, LRDBERTOLDMABP.E Luis R. Lomas P.E. 10.92WDODFORDRDLEWISVILLE`NC2M23 FL No.: 62514 WOOD FRAMING BY OTHERS #B WOOD SCREW 1 1/4" MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN 7/16" MIN _ EDGE DISTANCE 1/4" MAX r SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR ZXBUCKINSTALLATION METAL STRUCTURE BY OTHERS APPROVED SE7�\E T TRIM BEHINFIN 1 1/4_ MIN. EMBEDMENT WOOD FRAMING SCREW �6 WOOD BY OTHERS INTERIOR 1/4" MAX HOOK STRIP 7/16" MIN EDGE DISTANCE EXTERIOR RMSNNS REV 06 lnoN Mw MPRoAO A ADDED CHARTS 03/05/12 R.L B REVSED PER NEW TESTING 10/29/13 R.L. C ADDED FLANGE AND FIN INSTALLATIONS 12/06/13 R.L D REVISED INSTALLATION DETAILS 07/30/15 R.L E REVISED INSTALLATION DETAILS 06/2D/17 R.L 1 5/8" MIN. EDGE DIST. I TRIM A I ° ' 1 1/4" MIN. INTERIOR EMBEDMENT MASONRY/CONCRETE BY OTHERS 1/2" MIN. IX BUCK BY OTHERS, EDGE DISTANCE HOOK STRIP IX BUCK TO BE PROPERLY SECURED ❑ 3/16" TAPCON EXTERIOR PANEL INTERLOCK SHIM SPACE #10 SELF DRILLING SCREW INTERIOR VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION FOR SILL INSTALLATION SEE SHEETS 4-9. NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOTSHOWNFORCLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 2X BUCK OR WOOD FRAMING BY OTHERS TRIM INTERIOR HOOK STRIP PANEL EXTERIOR INTERLOCK HOOK STRIP INSTALLATION METAL STRUCTURE 1/2" MIN. EDGE DISTANCE 1 3/8" MIN. EMBEDMENT ❑ SWOOD SCREW EW D7 PANEL F.A. EXTERIOR INTERLOCK srALE HOOK STRIP INSTALLATION ZX BUCKANOOD FRAMING HOOKSTRIP INSTALLATION MASONRY/CONCRETE MI WINDOWS AND DOORS LLC 65D WEST MARKET STREET GRATZ. PA 17030 SERIES 420 SGD 96" X BD" NON —REINFORCED FIN AND HOOK INSTALLATION DETAILS IYxE uo. 08-00498 a 1 OATS 02/23/09 ISHM10 OF 10 L ROSERTOLOMASP.E. 102 IVOODFORD RD LE MSVIILE. NO 27023 SIGNED: 0612012017 Luis R. Lomas P.E. FL No.: 62514 4/24/2020 Florida Building SHOP STAMP REVIEW d l ridapr S,r-vm Review Is for general compliance with the Construction Documents. Responsibility for correctness of dimensions, details, quantities and safety during fabrication lies solely with the contractor. iiii No Exceptions Taken Reviewed By. Dawn Boggio-Korbelak 0 ReleRed: BCIS Home I Login I User Registranon I Hot Topics I Subnet swcbarye I Seats &Facts I Publications I Contact es I BCis Site Map I Dnks I search l�l L 11 Product Approval USER: Public User 4/28120 /1 $- �t Product ARoroval Menu> Productor Aptiaitti SearcM1>Altercation Llst>Application Detail FL # FL165 3-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer KAYCAN LTD Address/Phone/Email 1 Memorial Drive Richford, VT 05476 (662) 252-9991 Ext 231 jDe.lundine@kpproducts.com Authorized Signature Joe Lundine joe.lundine@kpproducts.com Technical Representative Joe Lundine Address/Phone/Email 402 Boyer St Williston, VT 05495 (662) 252-9991 jDe.lundine@kpproducts.com Quality Assurance Representative Joe Lundine Address/Phone/Email 402 Boyer St Williston, VT 05495 (662) 252-9991 joe.lu nd Ine @ kpp rod ucts. com Category Panel Walls Subcategory Soffits e FILE COPY Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CD Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. AnIDFUSO, P.E. Evaluation Report Florida License PE-49752 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance. Contract Ex to ration Dal 12/31 2020 Validated By Steven M. Unch, PE CA Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FU6503 R3 COI CI 2511 Revf) Vinyl -Soffit ss.gjff Standard Year ASTM D1929 2012 ASTM D2843 2010 ASTM D3679 2011 ASTM D635 2010 ASTM D638 2003 ASTM E330 2002 ASTM E330 2014 hftpslAyw .floridabuilding.org/pr/pr app_dti.aspx?param= GEVXQwtDgvgqu2w°/2bnFgUOixYpvH%2bzhsdlp2DLe2QWMgGNIV5TsM3A%3d%3d 113 4124/2020 Florida Building Code Online ASTM G155-05a 2005 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Licensed Professional Engineer or Architect FL16503 R3 Eauiv EER 2511 RevQ Vinyl-59ffi[ ss.RQf Method 1 Option D 12/O6/2017 12/12/2017 12/20/2017 02/13/2018 FL tF Model, Number or Name Description 16503.1 12" Triple 4 Full-O-Vent Eco (No. 12" Triple 4 Full-O-Vent Eco (No. 0639) with Single Spans 0639) - Single Spans Limits of Use Installation Instructions Approved for use in HVHZ: No FL36503 R3 It KAY0013 Rev A 639Eco VinvlSoffit- Sjagje Saar ss,gLf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Robert J. Amoruso, PE FL PE No. 49752 Design Pressure: N/A Created by Independent Third Party: Yes Other: See Installation Instructions for Design Pressures. Evaluation Reports FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss pdf Created by Independent Third Party: Yes 16503.2 Triple 4 Full-O-Vent Eco (No. 0639) - Triple 4 Full-O-Vent Eco (No. 0639) with Unlimited Spans Unlimited Spans Limits of Use Installation Instructions Approved for use in HVHZ: No FL16503 R3 II KAY0012 Rev A 639EcD VInyISofOt_ Unlimited Saan s "al f Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Robert J. Amoruso, PE FL PE No. 49752 Design Pressure: N/A Created by Independent Third Party: Yes Other: See Installation Instructions for Design Pressures. Evaluation Reports FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss.pf!f Created by Independent Third Party: Yes 16503.3 Various Series Vinyl Soffit - Single See Installation Instructions for Product Models Included. Spans Limits of Use Installation Instructions Approved for use in HVHZ: No FLI6503 R3 II KAY0011 RgvA VinylSoffit Sinojebpa.0s5,pdif Approved for use outside HVHZ: Yes Verified By: Robert J. Amoruso, PE FL PE No. 49752 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions for Design Pressures. FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss pp1 Created by Independent Third Party: Yes 16503.4 Various Series Vinyl Soffit - Single See Installation Instructions for Product Models included. Spans Limits of Use Installation Instructions Approved for use in HVHZ: No FL16503 R3 11 KAY0007 RevC VinvlSoffit ss.odf Approved for use outside HVHZ: Yes Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installation Instructions for Design Pressures. FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss,Ddf Created by Independent Third Party: Yes 16503.5 Various Series Vinyl Soffit- Unlimited See Installation Instructions for Product Series Included. Spans Limits of Use Installation Instructions Approved for use in HVHZ: No R16503 R3 II KAY0009 Rev A lfinyiSoffit- Approved for use outside HVHZ: Yes UnlinlitedSDan E%PA Impact Resistant: No Verified By: Robert J. Amoruso, PE FL PE No. 49752 Design Pressure: N/A Created by Independent Third Party: Yes Other: See Installation Instructions for Design Pressures. Evaluation Reports FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss Ddf Created by Independent Third Party: Yes https:IAw .floridabuilding.org/PrIpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUOixYpvH%2bzhsdip2DLe2QVVMgGNlV5TsM3A%3d%3d 2/3 4/24/2020 Florida Building Code Online Sack Ne>it Contact Us:: 2601 Blab Stone Road Dilaha,,c, FL 32399 Phnne: 850.4R2-1824 The State of Honda is an AA/EEO employer. Cy-nht 2002-2013 State of Florida.:: PdygM_5tatement:: AccessitdliLy Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a publlcrecords request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pummnt to Section 455.2)5(I), police Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalla provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available W the public. To determine If you are a licensee under Chapter 455, F.S., please click hee g-. product Approval Accepts: ® ® ®M '� 4 .9ccuritVAIET RICS, hops:/Ary .tloridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUOixYpvH%2bzhsdlp2DLe2QWMgGNIV5TsM3A%3d%3d 313 Product Evaluation Report Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 1 of 4 Product Manufacturer Kaycan Ltd. 1 Memorial Drive Richford, VT 05476 Code: Current Edition of the Florida Building Code Product Name, Model and/or Description Vinyl Soffit - Various Compliance Method: 61G20-3.005(1)(d) — Product Evaluation Report by a Licensed Professional Engineer Product Name, Model and/or Designation: Products covered by this evaluation include the following. • KAY0007 — Single Spans o 12" TRIPLE 4 SOLID SOFFIT 0 12" TRIPLE 4 VENTED SOFFIT 0 12" TRIPLE 4 CENTER -VENT SOFFIT o 12" TRIPLE 4 CENTER-O-VENT SOFFIT o 12" TRIPLE 4 FULL-0-VENT SOFFIT o 10" DOUBLE 5 SOLID SOFFIT o 10" DOUBLE 5 VENTED SOFFIT o 8" BEADED SOLID SOFFIT o 8" BEADED VENTED SOFFIT • KAY0009—Unlimited Spans 0 12" TRIPLE 4 SOLID, NO. 0623 SOLID SOFFIT 0 12" TRIPLE 4 FULL-0-VENT, NO.0622 VENTED SOFFIT 0 12" TRIPLE 4 FULL-0-VENT ECO, NO. 0639 VENTED SOFFIT • KAY0011 — Single Spans 0 12" TRIPLE 4 SOLID, NO. 0623 SOLID SOFFIT 0 12" TRIPLE 4 FULL-0-VENT, NO. 0622 VENTED SOFFIT 0 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT • KAY0012—Unlimited Spans o 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT • KAY0013—Single Spans 0 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT Product Installation Instructions: • PTC Product Design Group LLC, Drawing No. KAY0007, Rev. C, Dated il/27/17, by Robert J. Amoruso, P.E., Kaycan LTd. Vinyl Soffit - Solid and Vented, Installation Anchorage Details. • PTC Product Design Group LLC, Drawing No. KAY0009, Rev. A, Dated 11/27/17, by Robert J. Amoruso, P.E., Kaycan LTd. Vinyl Soffit— Various Solid and Vented with Unlimited Spans, Installation Anchorage Details. PTC Product Design Group LLC, Drawing No. KAY0011, Rev. A, Dated 11/27/17, by Robert J. Amoruso, P.E., Kaycan LTd. Vinyl Soffit — Solid and Vented with Single Spans, Installation Anchorage Details. PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 Jr/ILr 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 2 of 4 • PTC Product Design Group LLC, Drawing No. KAY0012, Rev. A, Dated 11/27/17, by Robert J. Amoruso, P.E., Kaycan LTd. Vinyl Soffit -12" Triple 4 Full-O-Vent Eco (No. 0639) with Unlimited Spans, Installation Anchorage Details. • PTC Product Design Group LLC, Drawing No. KAY0013, Rev. A, Dated 11/27/17, by Robert1. Amoruso, P.E., Kaycan LTd. Vinyl Soffit -12" Triple 4 Full-O-Vent Eco (No. 0639) with Single Spans, Installation Anchorage Details. • Industry Standard - Vinyl Siding Institute's Vinyl Siding Installation Manual, December 2015. Test Reports and Performance Testing Standards Used: KAY0007 Fenestration Testing Laboratory, Inc. Testing Report No. 7367, dated 6/1/13 including associated laboratory stamped drawings for Kaycan Vinyl Soffit testing to ASTM E330-02. Architectural Testing Inc. Test Report No. ATI 55983.01-106-18, dated 1/3/2006 for Kaycan Vinyl Soffit and Siding, materials testing to: i) ASTM D3679-01c, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding ii) ASTM G155-00ael, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non - Metallic Materials iii) ASTM D638-03, Standard Test Method for Tensile Properties of Plastics iv) ASTM D2843-99, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics v) ASTM D1929-96 (2000)e01, Standard Test Method for Determining Ignition Temperature of Plastics vi) ASTM D635-98, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position KAY0009, KAY0011, KAY0012 & KAY0013 • Molimo Architectural Product Testing,1410 Eden Road, York, Pennsylvania 17402—Vinyl Soffit Product Testing i) Test Report No.1169.01-106-11, SERIES/ MODEL: 0623 Solid Vinyl Soffit, "J" Channel / Fascia Installation, ASTM E330-14, dated 2/13/17 ii) Test Report No. 1169.02-106-11, SERIES / MODEL: 0623 Solid Vinyl Soffit, "J" Channel / "J" Channel Installation, ASTM E330-14, dated 2/13/17 iii) Test Report No.1170.01-106-11, SERIES / MODEL: 0622 Vented Vinyl Soffit, "J" Channel / Fascia Installation, ASTM E330-14, dated 2/13/17 iv) Test Report No. 1170.02-106-11, SERIES / MODEL: 0622 Vented Vinyl Soffit, "J" Channel / "J" Channel Installation, ASTM E330-14, dated 2/13/17 v) Test Report No.1171.03-106-11, SERIES / MODEL: 0639 Vented Vinyl Soffit, "J" Channel / Fascia Installation, ASTM E33044, dated 2/13/17 vi) Test Report No.1171.04-106-11, SERIES / MODEL: 0639 Vented Vinyl Soffit, "J" Channel / "J" Channel Installation, ASTM E330-14, dated 2/13/17 vii) Test Report No.1171.01-106-11-R1, SERIES / MODEL: 0639 Vented Vinyl Soffit, "1" Channel / Fascia Installation, ASTM E330-14, dated 1/31/17 PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r/L 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 3 of 4 • Architectural Testing Inc. Test Report No. ATI 55983.01-106-18, dated 1/3/2006 for Kaycan Vinyl Soffit and Siding, materials testing to: 1) ASTM D3679-01c, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding ii) ASTM G155-OOae1, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non - Metallic Materials iii) ASTM D638-03, Standard Test Method for Tensile Properties of Plastics iv) ASTM D2843-99, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics v) ASTM D1929-96 (2000)e0 1, Standard Test Method for Determining Ignition Temperature of Plastics vi) ASTM D635-98, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position Engineering Evaluation: • See Appendix A for Code Conformance Evaluation • Anchorage engineering and test result interpretation are documented in the following: o PTC Product Design Group LLC, Report No. 2240, Engineering analysis for Kaycan Vinyl and Aluminum Soffit, dated 7/11/13, by Robert J. Amoruso, P.E. o PTC Product Design Group LLC, Report No. 2492, Engineering analysis for Kaycan Vinyl and Aluminum Soffit, dated 3/20/17, by Robert J. Amoruso, P.E. Limitations & Conditions of Use: • This product has not been evaluated for use inside the High Velocity Hurricane Zone (HVHZ). • Refer to Product Installation Instructions noted abovefor: o Maximum allowable wind loads at related maximum allowablesize(s). o Overall dimensions and material/grade of main product components, accessories, etc. o Illustrated diagrams of the attachment of the product to substrate structure. o Anchor type(s), size(s), substrate(s), embedment, edge distance, and spacing/locations. • Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition of the Florida Building Code and/or ASCE 7-10 for components and cladding based on allowable stress design. • Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a licensed professional engineer or registered architect as required by the authority having jurisdiction. • Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or registered architect acting as the design professional of record for the project of installation. PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 i/S. 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61G2-3 F.A.C. I Report No. 2511 ( Project No. 417-0612 ( 11/27/17 ( Page 4 of 4 Certificate of Independence per Product Approval Rule 61G20-3.009 PTC Product Design Group, LLC and Robert J. Amoruso, P.E. does not have, nor will acquire, any financial interest in the company manufacturing or distributing product(s) covered by this Product Evaluation Report. PTC Product Design Group, LLC and RobertJ. Amoruso, P.E. do not have, nor will acquire any financial interest in any other entity involved in the approval process or testing of the product(s) covered by this Product Evaluation Report. Appendix A — Code Conformance Evaluation Evaluated by: RobertJ. Amoruso, P.E. FL PE License No. 49752 • Vinyl soffit certified and labeled as conforming to the requirements of ASTM D3679. • Vinyl soffit tested to 1.5 x Design Pressure. • Vinyl soffit labeled in accordance with the Florida Building Code. • Vinyl soffit plastics comply with Chapter 26 of the Florida Building Code as shown below. u o G0 o Q` a a � � N Test Standard F F N F on Acceptance Criteria Tensile Self - Smoke Class P/F N/A rest Density Ignition CCi or Test Variation Temp Test Report Report Product < 10% — 75 > 343oC CC2 Date 0 4to C 55 83I01- 1/3/2006 Vinyl Soffit Passed Tested CC1 106-18 Passed max8.1% max max max 4970C A�~A� PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 ii&. 321-690-1788 1 FBPE Certification of Authorization No. 25935 KAYCAN LTD VINYL SOFFIT - 12" TRIPLE 4 FULL-O-VENT ECO (NO. 0639) q WITH SINGLE SPANS w INSTALLATION ANCHORAGE DETAILS 0 a GENERAL NOTES: 1. THIS PRODUCT HAS BEEN TESTED AND DESIGNED TO COMPLY WITH THE CURRENT EDITION OF FLORIDA BUILDING CODE. BUILDING AND RESIDENTIAL VOLUMES EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AT THE DESIGN PRESSURES SHOWN ON SHEET 1. THESE PRODUCTS WERE TESTED TO ASTM E330-14. STRUCTURAL TEST RESULTS BASED ON ASTM E330-14 WERE DIVIDED BY 1.5 AS REQUIRED BY THE BUILDING CODE 2. DESIGN PRESSURE (DP)RATINGS SHOWN ONTHIS SHEETAREEASED ON10- EAVE WIDTHS IN SINGLE SPANS. SPAN WIDTHS AT 10'. 12-, 14' AND 16' ARE SHOWN ON SHEET 2. 3. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON TESTING PERFORMED AT MOLIMO ARCHITECTURAL PRODUCT TESTING, 11410 EDEN ROAD, YORK. PA 1740. 4. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE. MASONRY AND WOOD FRAMING COMPRISING THE ATTACHMENT SUBSTRATE FOR THE SOFFIT SHALL BE DETERMINED TO BE CAPABLE OF WRHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THATSTRUCTURE AND IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD FOR THE PROJECT. 5. OVERHANGS RECEIVING SOFFIT SHALL BE CHECKED FOR STRUCTURAL ADEQUACY, DAMAGE, CRACKS OR DEFECTS THAT MAY PRECLUDE THE SOFFIT FROM PERFORMING ITS INTENDED FUNCTIONS. SUCH DEFECTS SHALL BE ELIMINATED PRIOR TO SOFFIT INSTALLATION. 6. INSTALLATION OF SOFFIT AND ACCESSORIES SUCH AS CORNER POSTS, STARTER STRIPS, AND TRIM AROUND OPENINGS SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE - BUILDING AND RESIDENTIAL VOLUMES AND THE MANUFACTURER'S INSTRUCTIONS. 7. SITE CONDITIONS THAT DEVIATE FROM THE DETAILS OF THIS DRAWING REQUIRE FURTHER ENGINEERING EVALUATION BY LICENSED ENGINEER OR REGISTEREDARCHITECT S. SOFFIT SHALL BE LABELED IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE 9. SOFFIT NET FREE AREA IN ACCORDANCE WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE ARE SHOWN IN THE APPROVED SOFFIT SCHEDULE ON SHEET 1. 10. MATERIALS: 10.1. KAYCAN BUILDING PRODUCTSVINYLSOFFITANOTRIM IS MANUFACTURED FROMA FORMULATED PVC POWDER COMPOUND MEETING THE SPECIFICATIONS OF ASTM D3679. 10.1 KAYCAN BUILDING PRODUCTS ALUMINUM TRIM IS MANUFACTURED FROM ALUMINUM ALLOY WITH ASTM EB TESTED TENSILE STRENGTH OF 21 KSI AND YIELD STRENGTH OF 9.85 KSI. DESIGN PRESSURE (PSF) RATING AT 10" SPAN (NOTE 2) VINYL SOFFIT SERIES INSTALLATION METHOD OEM PRESSURE NET FREE AREA NET FREE AREA (SEE NOTE 2) (PSF) (SEE NOTE 1) (SQ. INJLINEAL FT.) (SQ. INJSQ. FT.) FASCIA / J—CHANNEL +66.7/-66J 4.18 4.18 12' TRIPLE 4 FULL-0—VENT ECO FASCIA / F—CHANNEL N0. 0639 VENTED SOFFIT J—CHANNEL / J—CHANNEL 466.7/-66.7 4.18 4.18 F—CHANNEL / F—CHANNEL NOTE 1: DESIGN PRESSURE RATINGS SHOWN ABOVE SHALL BE COMPARED TO LOADING BASED ON Vosd BASIC WIND SPEEDS. THUS PROJECT DESIGN PRESSURES AS DETERMINED FROM ASCE 7-1D BASED ON VNt BASIC WIND SPEEDS ARE PERMITTED TO BE MULTIPLIED BY 0.6 PER THE CURRENT EDITION OF THE FLORIDA BUILDING CODE FOR COMPARISON TO THE DESIGN PRESSURE RATINGS ABOVE. NOTE 2: SEE SHEET 2 FOR DESIGN PRESSURES AT 10', 12% 14' AND 16'. SEE SHEETS 3 AND 4 FOR SINGLE SPAN INSTALLATIONS FOR TRUSS/WOOD FRAMING CANOLEVER AND OVERHANG EAVE CONSTRUCTION. SEE SHEET 5 FOR CONNECTION DETAILS. VINYL SOFFIT AND TRIM SCHEDULE VINYL SOFFIT J.CHANNEL F-CHANNEL FASCIA SERIES 12" TRIPLE 4 1/2• J-CHANNEL 1/2" F-CHANNEL 4- FASCIA FULL-0-VENT ECO VINYL VINYL ALUMINUM NO. 0639 VENTED NO. 1100 ND. 1178 NO. 9700 SOFFIT TABLE OF CONTENT SHEET DESCRIPTION 1 GENERAL NOTES, PERFORMANCE RATINGS, SOFFIT SCHEDULE 2 INSTALLATION NOTES AND DP RATINGS AT VARIOUS SPANS 3 INSTALLATION DETAILS, CANRLEVER CONSTRUCTION 4 INSTALLATION DETAILS. OVERHANG CONSTRUCTION 5 INSTALLATION DETAILS A THROUGH F 6 SOFFIT PROFILE 7 CHANNEL AND FASCIA PROFILES / BOM RoIoMJ.Amorvw.P.E. TloWs P.E No. 49752 VINYL AND ALUMINUM SOFFIT INSTALLATION INSTRUCTIONS DP RATINGS AT VARIOUS SPANS 1. EAVE WIDTHS (SPANS) I.I. THE INSTALLATION CROSS SECTIONS SHOWN ON SHEETS 3 AND 4 DEPICT SINGLE SPANS FOR EAVE CONSTRUCTION OF TRUSSNMOOD FRAMING IN EITHER CANTILEVER OR OVERHANG CONFIGURATIONS. HOWEVER, THIS DOES NOT LIMIT SOFFIT INSTALLATION TO THESE CONFIGURATIONS ONLY AS LONG AS MINIMUM FASTENER REQUIREMENTS AND SPAN LIMITS ARE MAINTAINED. 1.2. SEETABLE ONTHIS SHEETFORSPANS OF IO', 12', WAND 16'. 2. INSTALLATION FASTENERS 2.1. FASTENERS SHALL BE THE TYPE, SIZE, EMBEDMENTAND EDGE DISTANCE SHOWN HEREIN FOR RESPECTIVE SUBSTRATE. SEE FASTENER SCHEDULE TABLE ON THIS SHEET. 22. MINIMUM EMBEDMENT EXCLUDE WALL FINISHES(INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING). EDGE DISTANCES SHALL BE SUCH TO PREVENTIVE CRACKING OF SUBSTRATE MATERIAL. 2.3. FASTENER LENGTHS SHOWN IN THE INSTALLATION DETAILS DO NOT TAKE INTO ACCOUNT WALL FINISHES. WALL FINISH THICKNESS SHALL BE ADDED TO THE REQUIRED FASTENER LENGTHS. SEE FASTENER SCHEDULE TABLE ON THIS SHEET. 3. 2X2 NOMINAL BATTEN INSTALLATION TO SUPPORTING SUBSTRATE STRUCTURE IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 4. ALL FASTENERS SHALL HAVE CORROSION RESISTANT COATINGS OR BE MADE OF CORROSION RESISTANT MATERIALS COMPATIBLE WITH THE SUBSTRATE MATERIALS. 5. SEE INSTALLATION MOUNTING DETAILS AND ILLUSTRATIVE INSTALLATIONS ON SHEETS 3, 4 AND 5. FASTENER SCHEDULE FPSIFNEADESCWPNON ..mu MIL FMBEDMEIR ISEE NOiE 1) EM.EDISiM'CE 0.097' DAMETER a CONCRETE i' 1/4• 1-1/2' T—NAIL OR MASONRY 0.072' DIAMETER X WOOD 1-3/4' 1/4' 1-3/4' TRIM NAIL 16 GA X 7/16' WIDTH CROWN STAPLE 1' MIN. WOOD 7/e_ 1/4' LENGTH #B x 3' FH WOOD SCREW OR @e x 3' FH TAPPING WOOD 1-1/2' 5/8' SCREW. 3/16' RW TAPCON CONCRETE 1' 1-1/8' CONCRETE SCREW OR MASONRY NOTE 1: EMBEDMENT BASED ON NOMINAL LENGTH OF FASTENER THROUGH SOFFIT OR CHANNEL INTO SUPPORTING SUBSTRATE W/O WALL RNISHES. WHERE WALL FINISHES ARE PRESENT, THE FASTENER LENGTH WILL BE INCREASED AS REQUIRED TO MAINTAIN EMBEDMENT DEPTH INTO SUPPORTING SUBSTRATE DESIGN PRESSURE (PSF) AT VARIOUS SINGLE SPAN LENGTHS 12"TRIPLE 4 FULL-O-VENT ECO / NO.0639 VENTED SOFFIT Single Span Length .IV, INSTALLATION DETAILS ATHRUF(SHEETS) Positive Negative 10 ALL 66.7 -66.7 12 ALL 55.6 -55.6 14 ALL 47.6 -47.6 16 ALL 41.7 -41.7 w 0 F RoWd J.Pma,u O,RP FIerIEa P.E. No. 4W62 r z 0 0 TRUSS/FRAMING CANTILEVER EAVE CONSTRUCTION -L' 1\/y SOFFIT / SEE DETAIL "A SEE DETAIL "B EAVE CROSS-SECTION SINGLE SPAN W/F-CHANNEL F•CHANNEL @ WALL, FASCIA @ FASCIA END SEE DETAIL "A"—�/ EAVE CROSS-SECTION SINGLE SPAN W/J-CHANNEL J-CHANNEL @ WALL, FASCIA @ FASCIA END SPAN "L' SAVE WIDTH (ROOF OVERHANG) " c a 0 U u SAVE WIDTH (ROOF w p OVERHANG) 'p °i a ¢E o \I 90 � g 4y o CONCRETE, ` � SOFFIT CMU OR zN a J CONCRETE, WOOD SEE DETAIL "D" SEE DETAIL "C" CMU OR "z (NOTE 1) WOOD wa zu (NOTE EAVE CROSS-SECTION „O jN 0. SINGLE SPAN W/J-CHANNELS a p y J-CHANNEL @ WALL AND FASCIA END o o y ec -w. 1A� SEE SHEET 2 FOR INSTALLATION NOTES, FASTENER SCHEDULE AND DESIGN PRESSURE PERFORMANCE RATING TABLES. SEE SHEET 5 OR DETAILS A, % C & D. NOTE 1: MINIMUM SPRUCE —PINE —FIR FRAMING @ 24" O.C. OR CONCRETE/MASONRY. BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET. RaW J.Am.—.M -L l\y SOFFIT SEE DETAIL "A / SEE DETAIL "B"_z EAVE CROSS-SECTION SINGLE SPAN W/F-CHANNEL F-CHANNEL @ WALL, FASCIA @ FASCIA END I SPAM 'C I� SOFFIT SEE DETAIL "A"� SEE DETAIL "E / EAVE CROSS-SECTION SINGLE SPAN W/J-CHANNEL J-CHANNEL @ WALL, FASCIA @ FASCIA END •L EAVE WIDTH (ROOF OVERHANG) WOR WOOD (NOTE 1) � SOFFIT "F" "E" SEE DETAIL SEE DETAIL EAVE CROSS-SECTION SINGLE SPAN W/J-CHANNELS J-CHANNEL @ WALL AND FASCIA END SPAN "L- —EAVE WIDTH (ROOF / OVERHANG) OVERHANG) CMU OR WOOD T/// (NOTE 1) SOFFIT SEE DETAIL "F"J SEE DETAIL "B" EAVE CROSS-SECTION SINGLE SPAN W/F-CHANNEL F-CHANNEL @ WALL, J-CHANNEL @ FASCIA END EAVE WIDTH (ROOF OVERHANG) CMIJ OR WOOD (NOTE 1) EAVE WIDTH (ROOF OVERHANG) CMU OR WOOD (NOTE 1) SEE SHEET 2 FOR INSTALLATION NOTES, FASTENER SCHEDULE AND DESIGN PRESSURE 2 FOR INSTALLATION NOTES, FASTENER SCHEDULE AND DESIGN PRESSURE PERFORMANCE RATING TABLES. SEE SHEET 5 OR DETAILS A, B, E & F. NOTE 1: MINIMUM SPRUCE —PINE —FIR FRAMING 9 24" O.C. OR CONCRETE/MASONRY. BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET. S 0 im w rcw V� �� = O a wz w o aF �o �w a FoE dJ.A=Nsa.P.E Mdda P.E. Na<9762 O 10 SiAPL6 I 7 MAX (INTO N EG OR T- (INIO y4�--1/B" MAX 1/8" DETAIL A DETAIL B FASCIA F-CHANNEL O STINS. 0 24 7 29' OFR iR FRAMING O SiAPIFS INSTAIl£0. 7 O 24 O.C. IMO F INC APL6 INSTALLED D W- HNNN 7 WOOD) IN P- (. 0EL SLDi OR T-NNL O tO O.C. Mf% NR 5 CONCRLTE/MASDNRY) OSOFFR OJ-CHANNEL `CONCRETE, CMU OR WOOD (NOTE 1) DETAIL C WOOD BATTEN 10 J-CHANNEL INS.ALUTION SCREW, B SAT.EN ATTACHMEW fA.ENER SPACED 24' 9 MAX. O.0 97 DR T Drvlo rvm J-CH NA -W 5 O.C. MN( CONCRETE NN ORAPLES Y 12' O.C. W000) IN SLOT CI 12' O.C. DETAIL D DETAIL E WOOD 1> J-CHANNEL J-CHANNEL FASCIA NOTE 1: MINIMUM SPRUCE -PINE -FIR FRAMING ® 24" O.C. OR CONCRETE/MASONRY. BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET. 27 IIMD WOOD) IN J-CHANNEL SLOT OR T-NAIL D 12' 5 D.C. MAx (INTO CONCRETE/MASONRY) ----CONCRaE, CMU OR WOOD (NOTE 1) DETAIL F J-CHANNEL FASCIA WOOD BATTEN 0 O 2P D APL6.C. O%-( . IN.D O FRAMING - /8 a D' WOOD SCREW OR TAPPING &CREW. BATTEN p A7ACHMEM GASIENER L) SPACED 24' NA%. O.C. Rabmt J. Amomao, P.E. Mdda P.E. No.48T52 N / � a W F71 m C `o z F C F— F N N zo o� 0z F-9 w w �N N V / TO I W UI V _ N P P IT1 1 II^I1 O �1A N m' KAYCAN LTD 1 MEMORIAL DRIVE PROJECT tt417-0614 m 3 RICHFORD, VT 05676 og SP NO. 639 VINYL SOFFIT INSTALLATION - SINGLE SPANS SOFFIT PROFILE -- or �uxW RJA 0312W1] xcxa A IIPOATETO C1i/1] RJP ricewsu N.T.S. wn KAV0013 EDITION OF THE iIEFSC FBO 12 ::..r�mmm.�xE. A e: 6OF7 r. 3 BILL OF MATERIALS MATERIAL FRDESCRIPTION SOF—SEESCHEDULEONSHEET1ANDDRAWINGS ONSHEET6WNYL F—CHANNEL—SEEDRAWINGONSHEET6(SEENOTE10ONSHEET1) E32 J—CHANNEL—SEEDRAWINGONSHEET6 FASCIA—SEEDRAWINGDNSHEET6(SEENOTEL1010NSHEET1) 0.097' DIAMETER z 1-1/2' T-NAIL FOR CONCRETE AND STEEL MASONRY SUBSTRATES. 6 0.072' DIAMETER % 1-3/4' TRIM NAIL STEEL ] 16 GA. % 7/16- WIDTH CROWN STAPLE 1' MIN. LENGTH STEEL e #6 z 3' FH WOOD SCREW OR #B z 3' FH TAPPING STEEL SCREW, USED TO ATTACH BATTEN TO WOOD STRUCTURE. 9 3/16' fTW TAPCON CONCRETE SCREW, MIN. 1' STEEL EMBEDMENT 10 2' % 2' NOMINAL WOOD BATTEN - SC = 0.42 MIN. WOOD p �$ 0 n' �m F �w 18rR.l (IB 0793 w og RO,D93 —0,16s RO a nE 5 'w 0.818 5° Sa6 0 ,775 ,7 5 4�"'�J' 1,499� 0,042 1,54 ; e= o R0.156 0.04 1'S 1 /2" J—CHANNEL/TRIM Vim a �n w 1,5 2 0,022 Fo a -i < L l VINYL (No. 1 100) 1/2" F—CHANNEL/TRIM Y UO LL VINYL (No. 1 178) 4" FASCIA SMOOTH pzz' ALUMINUM (No. 9700) o ilp z 1 aA R°Cert J.Am°rvw. P.E Flotltla P.E No,E8153 4124/2020 Florida Building Cl Rjo= SHOP STAMP REVIEW Iota/Man Caen Review is for general compliance with the Construction Documents. Respponsibility for correctness of dimensions, details, quantities and safety duringfabrication lies solely with the contractor. X No Exceptions Taken Reviewed By: Dawn Boggio-Korbelak ❑ Relected: BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stets & Facts I Publications I Contact Us I BCIS Site Map I Unks I Search d F� •da 4/28/20 {%Q as:i Product Approval USER: Pubec User pr 6� Product ARoreval Menu > Product or Aggllcatlon Search > Application List > Application Detall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval FL21637-R6 Revision 2017 Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. 87 MI Windows and Doors 650 West Market Street Gratz, PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Single Hung Certification Mark or Listing FILE COPY American Architectural Manufacturers Association Steven M. Urich, PE O Validation Checklist - Hardcopy Received Standard AAMA 506 AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/I.S.2/A440 Method 1 Option A 03/23/2020 03/23/2020 Year 2011 2008 2011 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsgxV7TjKGeecQb2JXWyVVril%2faFQMzcvxO%2bWwOJaurmQ%3d%3d 1/3 4/24/2020 Florida Building Code Online Date Approved 03/26/2020 Summary of Products FL tt Model, Number or Name Description 21637.1 1620 SH 48 x 84 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16015.pdf Approved for use outside HVHZ: Yes FL21637 R6 C CAC APC 160S4,pddf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +45/-45 10/14/2021 Other: LC-PG50 Fin, LC-PG45 Finless/Flange Installation Instructions FL21637 R6 IT 08-02998_BpAf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 513861B.pdf Created by Independent Third Party: Yes 21637.2 1620 SH 52 x 75 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 10016.pdf Approved for use outside HVHZ: Yes FL21637 R6 C CAC APC 16055.gd[ Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +50/-50 10/14/2021 Other: LC-PG50 Installation Instructions FL21637 R6 iI 08-02999B.pdj Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 513862B.gd( Created by Independent Third Party: Yes 21637.3 1620 SH 37 x 72 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16572.gdj Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/24/2022 Design Pressure: +50/-67 Installation Instructions Other: LC-PG50 FL21637 R6 11 08-03042B.(Ldf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514078A.pdf Created by Independent Third Party: Yes 21637.4 1620 SH 48 x 96 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16574.gdj Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/24/2022 Design Pressure: +35/-45 Installation Instructions Other: LC-PG35 FL21637 R6 IT 08-03160A.gd[ Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514079&Wj Created by Independent Third Party: Yes 21637.5 1620 SH Impact 38 x 75 Fin and Finless Frame, Insulated, Laminated Glass. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC(18143)1820.05-106-12-R1 1620 Approved for use outside HVHZ: Yes 51-1(015_23).pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-70 05/15/2023 Other: LC-PG50, Missile Level D, Wind Zone 3, glass was Installation Instructions bedded In Pecora 896 silicone. FL21637 R6 II 08-03454A.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 514467A.pAf Created by Independent Third Party: Yes 21637.6 1620 SH Impact 52 x 75 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21637 R6 C CAC APC 16230.PS f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date https:IAv .floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs9xV7TjKGeecQb2JXWyVVril%2faFQMzcwO%2bVMOJaurmQ%3d%3d 2/3 4/24/2020 Florida Building Code Online Impact Resistant: Yes 12/27/2021 Design Pressure: +50/-50 Installation Instructions Other: LC-PG50, Missile Level D, Wind Zone 3. Glass consisted FL21637 R6 II 08-03042B.pdf of 1/8" annealed exterior - spacer - 3/32" annealed / 0.090 Verified By: Luis Roberto Lomas 62514 PVB / 3/32" annealed. Glass was bedded in Pecora 896 silicone. Created by Independent Third Party: Yes Evaluation Reports FL21637 R6 AE 513921B.pff Created by Independent Third Party: Yes F. ck Naxt Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coq ll It 2007-2013 State of Florida.:: Privacy hmmenk:: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlo-records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees Ilcensed under Chapter 455, F.S. must provide the Department with an email atltlress If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made ava liable to the public. To calamine If you are a licensee under Chapter 455, RS., please click here. Product Approval Accepts: ®®® e'O=cF M Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtOgsgxV7TjKGeecQb2JX%Writ%2faFQMzcvxO%2bWWOJaurmO%3d%3d 3/3 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville NC, 27023 434-688-0609 rllomm@lrlommpe.com Manufacturer: MI Windows & Doors, LLC 650 West Market Street Gratz, PA 17030-0370 Engineering Evaluation Report Product Line: Series 1620 PVC Single Hung — Reinforced Non -Impact 52"x75" Report No.: 513862B Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval documents: drawing numbers 08-02999 Revision B, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: G1516.03-109- 47 signed by Timothy J. McGill Architectural Testing, Inc., York PA. AAMANVDMA/CSA 101/I.S.2/A440-08 Design pressure: ±50.13psf Water penetration resistance 7.52psf 3. Report No.: G1519.03-109-47 signed by Timothy J. McGill Architectural Testing, Inc., York PA. AAMA/WDMA/CSA 101/I.S.2/A440-08 Design pressure: ±50.13psf Water penetration resistance 7.52psf 4. Anchor calculations, report number 513862-113, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±50.Opsf • Unit size: 52 1/8" x 75" • Units must be glazed per ASTM E1300-04/09. • This product is not rated to be used in the HVHZ. • This product is not impact resistant and requires impact protection in wind bome debris regions. • Frame material to be Rigid PVC. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval documents, 08-02999, Revision B. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 1 of 1 �N```�S •.J E •.q. *• 0,f, 51 •• yt.� r o•� TAToF �w, i���Fs •.c� 0 R1�P G���� NAL1����`� Luis R. Lomas, P.E. FL No.: 62514 01/16/2020 (Validator / Operations Administrator) MI Windows & Doors, LLC P.O. Box 370 Gratz, PA 17030-0370 Attn: Rick Sawdey AAMA CERTIFICATION PROGRAM IMA This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMA/WDMA/CSA 101/I.S.2/A440.08 LC-PG50-1324x1905 (52x75)-H COMPANY AND CODE CPD NO. SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED DESCRIPTION 1620 SH (FINLESS & FLANGE) FRAME SASH MI Windows & Doors, LLC 16066 (PVC)(O/X)(OG)(INS GL) 1324 mm x 1905 mm 1257 mm x 946 mm Code: MTL (MODIF)(REINF)(TILT) (4'4" x 6'3") (4'2" x TV) (ASTM) This Certification will expire October 14, 2021 and requires validation until then by continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Intertek-ATI Report No.: G1519.03-109-47 Date of Report: November 3, 2016 JGS/JTS ACP-04 (Rev.6/11) Evaluated for Certification: November 8, 2016 ,h, A oci ted Laboratories, Inc. Authorized for Certification: November 8, 2016 DlrT" American hitecturalManufacturersAssociation (Validator / Operallons Administrator) MI Windows & Doors, LLC P.O. Box 370 Gratz, PA 17030.0370 Attn: Rick Sawdey AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION UQA This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMAMIDMA/CSA 101/I.S.2/A440.08 LC-PG504324x1905(52x75)-H COMPANY AND CODE CPD NO. SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED DESCRIPTION 1620 SH (FIN) FRAME SASH MI Windows & Doors, LLC 16016 (PVC)(O/X)(OG)(INS GL) 1324 mm x 1905 mm 1257 mm x 946 mm Code: MTL (MODIF)(REINF)(TILT) (4'4" x 6'3") (4'2" x 3'1") (ASTM) This Certification will expire October 14, 2021 and requires validation until then by continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Intertek-ATI Report No.: G1516.03-109-47 Date of Report: October 27, 2016 JGS/JTS ACP-04 (Rev.6/11) Evaluated for Certification: November 1, 2016 'h' /1 A( ted Laboratories, Inc. Authorized for Certification: November 1, 2016 American Mitectural Manufacturers Association NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR CD=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. TABLE OF CONTENTS SHEET NO.1 DESCRIPTION 1 NOTES 2 — 3 ELEVATIONS 4 —16 INSTALLATION DETAILS 17 COMPONENTS RENsm.s RN OESCflIPfION M.TE MPRWED A REVISED ANCHORS 02/27/16 R.L. B ADDED NEW EXTRUSIONS 1 01/16/20201 R.L. 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #6 EMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2'. MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 19. ALL FASTENERS TO BE CORROSION RESISTANT. 20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18CA (.048") FY=33KS1/FU=52KS1 OR ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM 21. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. SIGNED: 0112812020 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" X 75" NOTES 08-02999 NTS DATE 11/30/16 s"E'1 OF L ROBERTO LOADS P.E I Luis R. Lomos P.E. IG92WOODFORD RD LEWISVILLF NO 2M3 FL No.: 62514 A946B8-0699 rPDmas@I�lomaspe.rom 7 FR HEI F52 1/8" FRAME WIDTH —1 4" MAX J / 12MAX D.C. 5" WE GHT 4" MAX X 4 � 52 1/8" FRAME WIDTH 4""1MAX 2" _�/ D.C. O 75" FRAME HEIGHT 4" MAX 1620 SH REINFORCED FOR NUMBER 1620 SH REINFORCED RECTANGULAR OF ANCHORS DESIGNER EXTERIOR VIEW REQUIRED EXTERIOR VIEW FINLESS& FLANGE INSTALLATION SEE CHART #1 FINLESS& FLANGE INSTALLATION DESIGN PRESSURERATING IMPACTRATING +50.OPSF NONE 52 IR'X 75' UNIT SHOWN. OTHER SIZESAPPROVEDAS CONGAS FRAME AREA DOES NOT EXCEED 27.14' F P NOTES: 1. SASH SIZE: 4912'X37114' 2. D.L0.:471/ "X33314' RENSIONS REV pE$CRIPfION pq{E �PppWEO A REVISED ANCHORS 02/2J/18 R.L. B ADDED NEW EXTRUSIONS 01/16/2020 R.L. Chartdt Number of anchor locations required Forma width (in) 34.00 Heatl Jamb 30.00 Head Jamb 36.00 Head Jamb 43.00 Heatl Jamb 45.00 Heatl Jamb 5213 Head Jamb 3 3 3 3 4 3 4 3 3 ] 3 4 3 4 3 3 4 3 4 4 4 4 4 NF. 3 4 3 a 4 4 4 4 3 s 3 s 4 s 4 s 3 5 3 5 4 5 4 5 3 8 3 6 a 8 4 B38364B46 3 ) 3 T 4 T a 1 1 ) ] ) 4 T d ] 5 T 5 ) FOR NUMBER OF ANCHORS REQUIRED SEE CHART b1 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" X 75" FINLESS & FLANGE ELEVATIONS CpnwN: Deb ND. R.L. 08-02999 ii 4_E NTS IWE 11/30/16 sHEET2 OF 17 SIGNED: 0112812020 -•n111iIP1" Luis R. Lomos P.E. FL No.: 62514 7 FIR HE 52 1/8" FRAME WIDTH 3" MAX F F[ 8" MAX O.C. 3 AX __ 8" MAX D.C.O WE SHT 3" M MAX FOR NUMBER OF ANCHORS REQUIRED SEE CHART #2 52 1/8" FRAME WIDTH 3" MAX — B" MAX O.C. 111AXrr/ 8" MAX O.C. 75" FRAME HEIGHT 1 — 1620 SH REINFORCED RECTANGULAR EXTERIOR VIEW FININSTALLATION DESIGNPRESSURERATING IMPACTRA77NG 350.OPSF NONE 52 IM'X 75' UNIT SHOWN OTHER SIZESAPPROVEDAS LONG AS FRAME AREA DOES NOT EXCEED 2Z 14' Fla NOTES: 1. MAXIMUM SASHSIZE 49 lQ'X371Ai' 2. MAXIMUM D.LO.: 4712'X33374' V 1620 SH REINFORCED DESIGNER EXTERIOR VIEW FIN INSTALLATION RENSiONs REV DESCRIM104 041E APPROVED A RWISED ANCHORS D2/27/18 R.L. 8 ADDED NEW EXTRUSIONS 01/16/2020 R.L. 3" MAX FOR NUMBER OF ANCHORS REQUIRED SEE CHART #2 Chmtl2 said Ear of anchor locations required Forme Frame Width (Inn W l,hl (in) 24.0) HIS Jamb Jose HIS Jamb 36.00 HIS Jamb 4200 HIS Jamb 1 46.00 HIS Jamb 1 52.13 JH&S I.Jamb 24.00 4 4 4 4 5 4 0 4 7 30.00 4 4 4 4 5 4 6 4 7 J6.00 4 5 4 5 5 5 6 5 7 4Z00 4 6 4 6 5 6 6 6 7 4600 4 7 4 7 5 7 6 7 7 5I00 4 7 4 7 5 7 6 7 7 M74 Men 4 e 4 e s 66 6 7 55.00 4 9 4 9 5 9 8 9 7 72.00 4 10 4 10 5 10 a 10 7 75.00 4 10 4 10 5 10 6 10 7 SIGNED: 0112812020 1 MI WINDOWS LC. L/O4JJ/i 0 WEST SMAR ET STREET GRATZ, PA 17030-0370•y\GENs�.'9ji� \\\`%`S\1R. 0 it= SERIES 1620 SH REINFORCED*• NON —IMPACT 52 1/8' X 75"— FIN ELEVATIONS p�TAT E OF }•(f4�'\ �iOF :°[ OR109:•�`\� ERRWN: DWC NO. REV 08 B/�NA11EaG\\\ LDIS R. Lomas P.E. FL No.: fi2514 SCALE NTS DATE 11/30/16 5nDEU3B OF 17 LROSERFOLCMASP.E. F4 WOODFORD RDLEWISWILE, NC27023 431-6880609 7110maa®ld.,pa.rom WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT 1/4" MAX. SHIM SPACE -- - - -- ` HEAD TO BE SET IN A BED OF APPROVED SEALANT RMSION5 DOMRIWION MiE AG'.0 REVISED ANCHORS 02/27/18 R.L. ADDED NEW EXTRUSIONS 1 01/16/20201 R.L. 1 1/4" MIN. 1/4" MAX, EMBEDMENT SHIM SPACE N ERIOR 7/16" MIN. p�q EDGE DISTANCE ,��I���p®DR �p qe WOOD �� e EXTERIOR IL,isJ 111 `V INTERIOR SCREW a Qa a a OWOOD FRAMING OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD SILL TO BE SET & APPROVED q IN A BED OF SEALANT 11 APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 1/4" MAX. HIM SPACE JAMB INSTALLATION DETAIL WOOD FRAMING OR2 BUCKINSTACLATION SIGNED: 0112812020 MI LC. 510NDO T MAR ET STREET ```\J\511�111i/p % GRATZ, PA 17030-0370 `yyNG ENG,.,q 1y *• 0 9t= SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" X 75" FINLESS INSTALLATION DETAILS p Tp7S OF •�` ORAwx: MG No. OB B p7jS'ONA 11EN\��� LMIs R. Lomas P.E. FL No.: fi2514 scuE NTS DAIS 11/30/16 s0U4B OF 17 L ROBERTO LOWS AS. 1432 WOODFORD RD LEWISWUE.. NO 2AXs 4 688809 rllames@Irlwnuoe.mm METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/4- MAX. SHIM SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT 0 EXTERIOR v v v q INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD I, 0 & APPROVED u SEALANT 1/4" MAX. SHIM SPACE METAL STRUCTURE —� BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWN FOR CLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WITHASTM E2112 RPASIONS 7"`sa"W104 DATE APPROVED A REVISE. ANCHORS 02/2J/18 1 R.L. 8 ADDED NEW EXTRUSIONS 01/16/2020 R.L. 1/4" MAX. SHIM SPACE 7/16" -� MIN. EDGE DISTANCE I / INTERIOR #8 EMS OR -� LILJLIO SELF DRILLING n�D SCREWS EXTERIOR METAL STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" % 75" FINLESS INSTALLATION DETAILS MG NO. 08-02999 NTS JOATE 11/30/16 JSnEE15 OF 17 L ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISWU E, NO 2= 434,68"609 0/omaz®14omafne.mm SIGNED: 0112812020 Luis R. Lomas P.E. FL No.: 62514 RLNSIONS REV OESCPIGTON pp1E nPpFOVEO A REVISED ANCHORS D2/27/18 R.L. CONCRET • BY OTHERSASONRY a �. '4 a B ADDED NEW EXTRUSIONS 01/16/2020 R.L. OPTIONAL IX BUCK SEE NOTES 3 - 7 SHEET 1 I 1 1/4" MIN. _ 1/4" MAX. EMBEDMENT SHIM SPACE (� BACKER ROD & APPROVED n� 1/4" MAX. CONCRETE/MASONRYBY SEALANT II�� o� 21 SHIM SPACE OTHERS a HEAD TO BE SET OPTIONAL 1X BUCK. IN A BED OF SEE NOTES 3 - 7 APPROVED SEALANT SHEET 1 •° INTERIOR �,,�����;; ����p® �❑ 3/15" TAPCON •• c �^ (l��y(o e` EXTERIOR IL„l�aJ lrl, �Q'v''DD��vLfv q INTERIOR II IEl I'fbnV4 2- MIN. EDGE D -- DISTANCE p SILL BE SET O• EXTERIOR BACKER ROD 1) IN A BB ED OF & APPROVED APPROVED SEALANT SEALANT I,L��lf1 O BACKER ROD OPTIONAL 1X BUCK _ O 1/4" MAX. SHIM SPACE & APPROVED SEE NOTE 3 - 7 4q ❑ SEALANT SHEET 1 JAMB INSTALLATION DETAIL —� CONCRETE/MASONRYINSTALLATION CONCRETE/MASONRY BY OTHERS SIGNED: 0112812020 " MI WINDOWS & DOORS, LLC. • ,' e 650 WEST MARKET STREET GRATZ. PA 17030-0370•*\OEHS'•9J+i \�yu1N/nII7 `\\`\$ R• LO�Ai7j VERTICAL CROSS SECTION SERIES 1620 SH REINFORCED*• p51 *' CONCRETFJMASONRYINSTALLATION NON -IMPACT 52 1/8" X 75" FINLESS INSTALLATION DETAILS �y+• $TAT OF �i�d`E•y.• .,[ORIDQ: NOTES: T. INTERIORAND EXTERIOR BY OTHERS, ow,wN: owc No. 08 REv 6\ems: B 11,NAj1E��\`` NOTSHOWNFO CLART:IN/SHES. scuE NTS MTL 11 /30/16 sxOEEr68 OF 17 2. PERIMETERANDJOlN SE4"lVTBYOTHERSTOBE DESIGNED/NACCORDANCE W/THASTM E2112 LROEERTOLOMASP.E LDI9 R. Lomas P.E. 1432W000FORDRDLEWISWLLE, NC2)023 FL NO.: 82514 434t'360309 tlbmss®Inomaspe.rom WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD I j 51 1/4" MAX. J & APPROVED �`� LI SHIM SPACE SEALANT IEI o O HEAD TO BE SET IN A BED OF APPROVED SEALANT O q® �0 EXTERIOR �i5 t—� INTERIOR O n v �� 0 BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCKINSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFOR CLARITY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED IN ACCORDANCE WITH ASTM E2112 SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. HIM SPACE RM IONS OMRIPTION DeIE REVISED ANCHORS 02/27/16 1 R.L. ADDED NEW EXTRUSIONS I 01/16/2D20 R.L. 1 1/4" MIN. 1/4" MAX. EMBEDMENT F SHIM SPACE I INTERIOR 7/16MIN. n��� EDGE DISTANCE #8 WOOD SCREW WOOD FRAMING . �p OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED: 0112812020 MI WINDOWS LC. 0STMAR ET STREET `511RIILo `\\`'x. GRATZ. PA 17030-0370 `�yy�C ENS�'9j1� 0•,5�6 SERIES 1620 SH REINFORCED*• NON —IMPACT 52 1/8" X 75" FLANGE INSTALLATION DETAILS y TOF / ��'eFs; G DRAWN: DWG NO. PEV 08 B .� O. i�A/S/ N20RI111 LNIS R. Lomas P.E. FL No.: 62514 e0\ SE NTS DATE 11/30/16 sx0EET78 OF 17 LROEERTOLOM P.E IG32WOODTORDRDLMSWLLENC27023 494-668&0609 rllamazta�lrlomuoR.mm METAL STRUCTURE BY OTHERS APPROVED SEALANT BACKER ROD & APPROVED SEALANT BY OTHERS ' 7 1/4" MAX. SHIM SPACE TO BE SET IN A BED OF APPROVED SEALANT INTERIOR VERTICAL CROSS SECTION METAL STRUCTUREINSTALLAT70N NOTES: 1. INTERIORAND EXTERIOR FINISHES BYOTHERS. NOTSHOWNFOR CLARITY. Z PERIMETERANDJOIN7SEALANTBYOTHERSTOBE SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE RENSIONS DESCRIKION WiE MpgOVEp REVISED ANCHORS 02/27/18 R.L. ADDED NEW EXTRUSIONS 1 01/16/20201 R.L. _ 1/4" MAX. SHIM SPACE L INTERIOR 7/16" MIN. r ��D EDGE DISTANCE Q8 SMS OR —� �I SELF DRILLING u� SCREWS METAL EXTERIOR STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 01/28/2020 LC. MI WINDOWS5DTET STREETMARKET `R.L / GRAB. PA 17030-0370 ` yy�GENyF''P z*.�•{{�k ��•,10 51 *, SERIES 1620 SH REINFORCED NON —IMPACT 1/8' X 75" LL FLANGE INSTALLATION DETAILS ' S 1 � �p • $TAT OF ty; /�"�• ;°[ORIOa:• DRAWN: owc No. mo REV R.L.S�LE 08 a%�NA1IENG`��\ LMIS R. Lomas P.E. FL ND.: 62514 NTS WTE 110- SHEETS02999 OF 17 LROBERTOLOMASP.E. lCA24-68"6 RD RD LEWISVID.E NC2T029 DLEMCallrlOmespe.mm ASGBB6-0609 CONCRETE/MASONRY —� BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHEET i CONCRETE/MASONRY BY OTHERS NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWN FOR CLARITY. 2 PER/METERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WTTHASTM EV 12 a ° a RMSIONS REV DMCRII1NON DUE APpRQJEO A REVISED ANCHORS 02/27/16 1 R.L. B ADDED NEW EXTRUSIONS 1 01/16/2020 R.L. J I 1 1/4" MIN. 1/4` MAX. EMBEDMENT SHIM SPACE 1 /4" MAX CONCRETE/MASONRY SHIM SPACE BY OTHERS •a . • — HEAD TO BE SET OPTIONAL IX BUCK . IN A BED OF SEE NOTES 3 — 7 ° APPROVED SEALANT SHEET 1 +° INTERIOR 3/16" TAPCON INTERIOR e _a. e 2" MIN. EDGE o D � �� DISTANCE ° EXTERIOR SILL TO BE SET IN A BED OF .a > APPROVED SEALANT BACKER ROD 1 4" MAX A & D SHIM SPACE SEALANT JAMB INSTALLATION DETAIL --F CONCRETEIMASONRYINSTALLA77ON MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8' X 75" FLANGE INSTALLATION DETAILS Dm.ml D.G NO. R.L. 08-02999 scut NTS JDAIE 11/30/16 1sREET9 OF 17 L ROBERTO LOMASP.E. 14VWOODFORDRO LEWISVN.E N027Wa 404-6860609 Alomas@Irlwnssps.rom SIGNED: 0112812020 "'�/IIIIIPI"- Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT MAX. I SPACE HEAD TO BE SET IN A BED OF APPROVED SEALANT 0 �Mtt® =o EXTERIOR E'�i q INTERIOR l7 6 O 0 WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCKINSTALIATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARRY. 2 PERIMETERAND JOINTSEALANTBY OTHERS TO BE DESIGNED IN ACCORDANCE WIT H ASTM U 112 SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. HIM SPACE 1 1/4" MIN. EMBEDMENT 1 7/16" MIN. EDGE DISTANCE RMSONS REV DESCRIPTION DALE MPRWEC A REVISED ANCHORS 02/2J/18 R.L. 8 ADDED NEW EXTRUSIONS 01/16/2020 R.L. 1/4" MAX. SHIM SPACE INTERIOR #8 WOOD J �� e SCREW D WOOD FRAMING ED OR 2X BUCK EXTERIOR BY OTHERS BACKER ROD & APPROVED JAMB INSTALLATION DETAIL SEALANT WOOD FRAMING 0R2XBUCKINS7ALLATI0N MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" X 75" FLANGE INSTALLATION DETAILS OR wN: m No. R.L. 08-02999 >CAEE NTS IMTE 11/30/16 SHEETIO OF 17 SIGNED., 0112812020 Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS APPROVED SEALANT 1/4" MAX. SHIM SPACE TO BE SET BED OF OVED SEALANT �j�J� 7x[. �11��I■11 -.- SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD & APPROVED SEALANT WE HIM MAX. SHIM SPACE METALSTRUCTURE—� BY OTHERS VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIORAND EXTERIOR FINISHES, BY OTHERS, NOTSHOWNFORCLARRY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WTIHASTM E2112 REY510N5 DESCRIPTION REVISED ANCHORS ADDED NEW EXTRUSIONS 7/16" M EDGE Molql:�:�EX�TERIOR DISTANCES#B SMS OI RSELF SCREIWS METAL STRUCTURE BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION �1 1/4" MAX. SHIM SPACE INTERIOR MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED NON -IMPACT 52 1/8" X 75" FLANGE INSTALLATION DETAILS DRAWN: ONG NO. REV R.L. 08-02999 B 3ULE NTS I WE 11/30/16 15HEU11 OF 17 LHOSERTOLOMASP.E. 1432 WOODFCRD RD LEWISVILLE NC 27023 ausee-osos nlDnd:�+InwRasPs.swR DATE APPROVED 02/2"/16 R.l 01/16/2020 R.L. SIGNED: =28/2020 Luis R. Lomas P.E. FL No.: 62514 CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED SEALANT ••4 i 1/4" MAX. owl SHIM SPACE O HEAD TOSET IN A BEE OF OF IIIIII APPROVED SEALANT INTERIOR SILL TO DE SET BACKER ROD IN A B BED OF & APPROVED APPROVED SEALANT SEALANT O 1/4" MAX. 0� OPTIONAL 7% BUCK SEE NOTE 3 — 7 �C] 0 SHIM SPACE SHEET 1 CONCRETE/MASONRY BY OTHERS a VERTICAL CROSS SECTION CONCRETEIMA SONRY INSTALLATION NOTES: 1. INTERIORANO EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. P. PER/METERANOJOINTSEALANTBYOTHERSTOBE DESIGNED IN ACCORDANCE WRH ASTM E2112 REASONS DESCRIPTION biE MPRWEO REVISED ANCHORS 02/2]/16 R.L. ADDED NEW EXTRUSIONS 1 01/16/2020 R.L. 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS •c s OPTIONAL IX BUCK SEE NOTES 3 — 7 a 1/4" MAX. SHEET 1 .° SHIM SPACE INTERIOR 3/16" TAPCON •• v a 2 MIN. EDGE lull DISTANCE EXTERIOR BACKER ROD & APPROVED JAMB INSTALLATION DETAIL SEALANT CONCRETEMASONRYINSTALLATION SIGNED., 0112812020 MI WOW5I0NDEST MAR ET S REETLC ``\��\Sl1RIILro A GRATZ, PA 17030-0370•y�GEN6". j±� *.�•{�yiL`�••1Da.612/5�1/+Yst 1F= SERIES 1620 SH REINFORCED NONGIMPACT ION X 7IL •a' LL FLANGE INSTALLATION DETAILS S E C pO•• $TAT OF ery` �i'�ps.'L•CORI�P: oanwu: MG NO. RN 08 2999 B/0nllnlll�?\`\` LD16 R. LOTaS P.E. FL NO.: 62514 SGLE NTS DAZE 11/30/16 SHEV112 OF 17 L flO8ERT0 LOWS PS 1432W000FORORDLEWISVN.E,NO2=3 d9<-689-0609 mwrias@Iriwnaspe.rom APPROVED SEALANT BEHIND FIN #6 WOOD SCREW NOOD =RAMING 3Y OTHERS 1/4" MAX. SHIM SPACE RMSIONS OESCPIPLION DATE I gPPROVM REVISED ANCHORS 02/27/18 1 R.L. ADDED NEW EXTRUSIONS 1 01/16/20201 R.L. 3/8" MIN F _ EDGE DISTANCE �o� 7 SHIM SPAC WOOD FRAMING E BY OTHERS .� o� #6 WOOD SCREW INTERIOR _`J�yIJN L[; I�IY■ Mill I 3/8" MIN EDGE DISTANCE #6 WOOD SCREW APPROVED _....._....,_. SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCKINSTALLAflON NOTES: 1. INTERIORAND EXTERIOR FINISHES. BYOTHERS. NOTSHOWNFORCLARITY. 2. PERIMEERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WTTHASTM E2112 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS 1 1/2" LI o MIN. EMBEDMENT OO El 0❑ 0 APPROVED SEALANT BEHIND FIN 3/e" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR2X BUCKINSTAL"TION SIGNED: 0112812020 MI 650NDOSSMAR R11L7O�/,� REETLC. ET STREET GRATZ, PA 17030-0370 ` yyNGENS�•9iP *� pA,5�6 TT', SERIES 1620 SH REINFORCED NON -IMPACT 52 1/8' X 75" FIN WITH J CHANNEL INSTALLATION DETAILS O; STATE OF •�; ��"p�•'�LGR1V:•\��� DskwN: MONO.-299 RCv R.L 08 B jss/�NALIENG��` LUIS R. Lomas P.E. FL No.: 62s14 NTS WE 11 /30/16 sOEEr 93 OF 17 LROSERTOLOMASP.E 102 WOODFORD RD LEWISVILE NC27O27 434-0809 Rlanoa?W maspe.. APPROVED SEALANT BEHIND FIN #6 SMS OR SELF DRILLING SCREW 3/8" MIN EDGE DISTANCE �=_I� I_ IQ 3/8" MIN J EDGE DISTANCE #5 SMS OR c SELF DRILLING SCREW VERTICAL CROSS SECTION APPROVED MET ALSTRUCTUREINSTALLATION SEALANT BEHIND FIN NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOTSHOWNFORCLARfFY. 2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE DESIGNED INACCORDANCE WIMASTM E2112 METAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE METAL STRUCTURE BY OTHERS PE41510N5 OMsIFTIO. wiE APPROVE. REVISED ANCHORS 02/27/18 R.L. ADDED NEW EXTRUSIONS I 01/16/2020 R.L. 1/4" MAX SHIM SPACE METAL STRUCTURE BY OTHERS NFERIOR j16 SMS OR SELF DRILLING n�o SCREW APPROVED SEALANT BEHIND FIN EXTERIDfl 3/8" MIN _ EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0112812020 MI WIONDOWSWESTMBCRKET DOORREETLC `SIIRIILfo/�i GRATZ, PA 17030-0370 y •�*\G ENS". 'P D5 iF SERIES 1620 SH REINFORCED*• NON —IMPACT 52 1/8" X 75 (�1/f+C6+ FIN WITH J CHANNEL INSTALLATION DETAILS OTATE OF •� S 'PlORl01; G�'e�� PRAWN: pWC NO. REV 08 B ,'/7SfOI11A111x\\```` Luis R. Lomas P.E. FL No.: 62514 xA� NTS pme 11 /30/16 sOF094 OF 17 L ROBERTO LOMAS P.E. 1192WCODFOBDROLEWISVILLENC2ID29 43d 8D609 rllamas�Wlrbmazm.rom APPROVED SEALANT BEHIND FIN #6 WOOD SCREW 3/8" MIN EDGE DISTANCE I ilJ N[I III■ l 3/8" MIN J EDGE DISTANCE #6 WOOD SCREW APPROVED 1 1/2" M EMBEDME SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLA77ON NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS, NOTSHOWN FOR CLARITY. 2. PERIMETER AND JOINTSEALANTBYOTHERS TO BE DESIGNED INACCOROANCE WITHASTM E2112 WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS RCASIONS 9ESCRIPIION neiE MPR D REVISED ANCHORS ADDED NEW EXTRUSIONS 1 01/16/20201 R.L. 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS #6 WOOD SCREW INTERIOR 1 1/2" MIN. EMBEDMENT APPROVED SEALANT BEHIND FIN 3/8" MIN _ EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OF 2X BUCKINSTALLATION SIGNED: O7/28/2020 MI WINDOWS & LC. ll ll 0MARKET STREET \\S \R�owz" GRATZ, PA 17030-0370•�NGENyF'9ji 2*• p6 �T', SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8" X 75" —/!/try'1(�((c�1�t',p•� FIN INSTALLATION DETAILS y ; STgTF •k�,` %O•C• 'P[OR1OP•�t DRRWN: p 5 NO. REV 08 95 B �/•L/rjsT11N1EaG���\ AL Luis R. Lomas P.E. FL No.: 62514 'GALE NTS DATE 11/30/16 SHEET OF 17 L ROBERTD LOWS P.E. 1432 WOODFORD RD LEWISWUE, NC 21023 49 8b 0609 AomazOlrbmazPe.mm T APPROVED SEALANT BEHIND FIN #6 SMS OR SELF DRILLING SCREW 3/8" MIN EDGE DISTANCE l=• �� .. "" METAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX r SHIM SPACE 3/8" MIN EDGE DISTANCE j/6 SMS OR SELF DRILLING METAL STRUCTURE BY OTHERS SCREW VERTICAL CROSS SECTION APPROVED METAL STRUCTURE INSTALLATION SEALANT BEHIND FIN NOTES: 1. INTERIORAND EXTERIOR FINISHES, BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETERANDJOINTSEA"4 BYOTHERSTOBE DESIGNED IN A CCORDANCE WITH AST M E2172 RMSIONS REV OESCRIPIION MiE MpRWEO A REN6E0 ANCHORS 02/2T/16 R.L. B ADDED NEW D(MUSIONS O1/16/2020 R.L. 1/4" MAX r SHIM SPACE METAL STRUCTURE BY OTHERS INTERIOR #6 SMS OR SELF DRILLING SCREW APPROVED J PIQ S EA ANT BEHIND FIN 3/8" MIN EXTERIOR EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030-0370 SERIES 1620 SH REINFORCED NON —IMPACT 52 1/8' X 75" FIN INSTALLATION DETAILS R.L. 08-02999 SO^EE NTS MTE 11/30/16 ISHM16 OF 17 L ROBERTOLOMASP.E. 1432 WC0OFORD RO U5WISVlU E, NC 2Ta23 43mcea0600 moW,R:@IMnacpe.wm SIGNED: 0112812020 Luis R. Lomas P.E. FL No.: 62514 3 3/16" o� 2 5/16" L QElpe HEAD/JAMB FINLESS EXTRUDED PVC(VV008) 3 1 HEAD/JAMB FIN INSTALLATION EXTRUDED PVC (V.10079 3 1/4" — O 1 B" 4gp�4� SILL FINLESS EXTRUDED PVC (V-1013) I-- 3 1/4" —1 SILL FIN INSTALLATION EXTRUDED PVC (V.1012) 2 1 2 1 HEAD/JAMB WITH FLANGE EXTRUDED PVC (V.1010) HEAD/JAMB WITH FLANGE EXTRUDED PVC (VE-000025) 1 1/4" �o o� 3 13/16" �1f l— 1104 4gp0 3 5/6" � Lr�Jlr✓ 1 T L HEAD/JAMB FIN INSTALLATION SILL FIN INSTALLATION BOTTOM SASH/STILE WITH J-CHANNEL WITH J-CHANNEL EXTRUDED PVC (V.670) 7/B STILES REINFORCEMENT ALUMINUM 6063-T5(M-2266) 3/4" 1 V�^ri��nJ1 J MEETING RAIL REINFORCEMENT ALUMINUM 600-75 (AE-000162) -L—rF 15/16" /� LOCK RAIL REINFORCEMENT ALUMINUM 6063-T5 (M-2115) L15/16" 3/4" rT 5� II IS I—�- DRP. OPERABLE SCREEN R.L. TRACK W/O LEG saEE ALUMINUM 6063-T6(M-2341) 00CR .. REVISED ANCHORS ADDED NEW EXTRUSIONS 3 1/4" —I 1 8- SILL WITH FLANGE EXTRUDEDPVC(V-1015) SILL WITH FLANGE EXTRUDED PVC (VE-000021) pIE1�y 2 3/16" �L (n MEETING RAIL EXTRUDED PVC (V-1016) flENSIDNS neTO naflflwED 02/27/18 R.L. O1/16/2020 R.L. 2 3171 D 1 3/4" BOTTOM SASH/TOP RAIL EXTRUDED PVC (11-675) 1 3/4" 8. 34" Ell BOTTOM SASH/BOTTOM RAIL EXTRUDED PVC (V.672) �I r,/4" 3/16" G IZLA NG BEAD RIGID PVC (V-804) SIGNED: 0112812020 MI WINDOWS & DOORS, LLC. 650 WEST MARKET STREET GRATZ. PA 17030-0370 SERIES 1620 SH REINFORCED NON -IMPACT 52 1/8" X 75" COMPONENTS DWG N0. REV OB-02999 B NTS -E 11/30/16 sREU17 OF 17 43ec "09 Luis R. Lomas P.E. FL No.: 62514 f NOTES: ALL MATERIALS AND CONSTRUCTIONS PROCEDURES SHALL BE IN ACCORDANCE WITH THE LATEST FDOT INDICES AND AS FOLLOWS: 1. CONCRETE TO BE MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 2. TEST A MINIMUM OF ONE (1) COMPRESSIVE STRENGTH CYLINDER SAMPLE PER 50 CY OR ONE (1) PER LOT, WHICHEVER IS GREATER. COMPRESSIVE STRENGTH SHALL BE REPORTED AT 28 DAYS. 3. ALL DELETERIOUS MATERIALS TO BE REMOVED 6 INCHES BELOW BOTTOM OF SIDEWALK AND 6 INCHES BEYOND ALL EDGES. 4. CONCRETE SHALL BE A MINIMUM OF 4 INCHES THICK FOR ALL SIDEWALK TO BE OWNED OR MAINTAINED BY THE COUNTY. 5. SIDEWALK THROUGH DRIVEWAYS SHALL BE 4" THICK MINIMUM. 6. SOD TO BE LAID WITHIN THREE (3) DAYS OF FINAL GRADING IN PUBLIC RIGHT OF WAY. 7. PRE -POUR INSPECTIONS ARE REQUIRED AND MUST BE ACCEPTED PRIOR TO POURING THE SIDEWALK. 8. FOR REPAIR, REMOVE EXISTING SIDEWALK TO THE FULL WIDTH FROM CONTROL JOINT TO CONTROL JOINT (I.E. ONE *SECTION*) 9. 12" MINIMUM VISQUEEN AND CHEMICAL TERMITE TREATMENT AT ALL AREAS THAT ABUT ANY EXISTING CONCRETE STRUCTURE. 10. PROPERTY ADDRESS: ___ ARMINA PLACE 4f WCAULFIELD & WHEELER, INC. CIVIL ENGINEERING LANDSCAPE ARCHITECTURE - SURVEYING 7900 GLADES ROAD - SUITE 100 BOCA RATON, FLORIDA 33434 PHONE (561)-392-1991 / FAX (560-750-1452 FILE COPY �.�uunurrrr nTE OF r s. 0 uunuu•" DATE 4/27/2020 DRAWN BY EC F.B./ PG. N/A WATERSTONE, PHASE 1 DRIVEWAY DETAIL — LOT 59, BLOCK 3 SCALE NO. N.T.S. w 8 6'x6' WELDED WIRE MESH 16' 4" THICK 4" THICK d I 4" THICK @ j I DRIVEWAY I /20' MAX. APRON @ ROAD OCAULFIELD & WHEELER, INC. CIVIL ENGINEERING LANDSCAPE ARCHITECTURE - SURVEYING 7900 GLADES ROAD - SUITE 100 BOCA RATON, FLORIDA 33434 PHONE (561)-392-1991 / FAX (561)-750-1452 WATERSTONE, PHASE 1 DRIVEWAY DETAIL - LOT 59, BLOCK 3 4" EXPANSION JOINT 4" THICK SIDEWALK JOINTS DATE 4 27 2020 DRAWN BY EC F.B. PG. N/A SCALE N.T.S. JOB N0. 8690