HomeMy WebLinkAboutAPPROVED metal union 2019 Business • ii !
' Regulation rg Mira
BCIS Home Log In User Registration Hot Topics ! Submit Surcharge Stats&Facts Publications Contact Us BCYS Site Map Links Search
b3
� , Product Approval
��` USER:public User
94
Product Approval Menu>Product or Application Search>Application LisY>Application Detail
FL# FL20484-Rl
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE,NC 28301
(910)483-0479 Ext756
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
... Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL20484 RI COI Certificatelnde endence. df
Referenced Standard and Year(of Standard) Standard Year
FM 4470 2012
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
hops://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgX... 10/12/2019
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
20484A 5V Min 26 ga.,24"wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 RI II EvaluationReuortC2175 1 DdF
Approved for use outside HVHZ:Yes Verified By: Sala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-169 Evaluation Reports
Other: Uplift load of 71.0 psf @ fastener spacing of 24"o.c. FL20484 R1 AF Evaluation ReportC2175 1 odf
&169.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party:Yes
20434.2 Advantage-Lok II Min 26 ga., 16"wide concealed fastened panel over 7/16"
thick OSB&15/32"&thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 RS iI @valuationReoortC2175 2 odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant. N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-116 Evaluation Reports
Other: Maximum uplift load of 116.0 psf @ seam fastener FL20484 Rl AE EvaluaUunReoortC2175 2 odf
spacing of 4-5/8"o.c.along seam into min. 15/32"thick APA Created by Independent Third Party:Yes
rated plywood with retainer strap.
20464.3 Aluminum Advantage-Lok II Max 16.375'wide,nom 0.032"thick(min.)aluminum
concealed fastener roof panel over min 15/32"thick plywood
deck or 7/16"thick OSB.
Limits of Use Installation instructions
Approved for use in HVHZ. No FL20484 R1 II Eva€uatipnReportC2175 3 pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party;Yes
Design Pressure: +N/A/-93.5 Evaluation Reports
Other:Uplift load of 22.5 psf at Fastener spacing of 18.5" FL20484 R1 AE EvaluationRenort 2175 3 pdf
o.c.and 86.0 psf at fastener spacing of 4.63"o.c.in 15/32" Created by Independent Third Party:Yes
plywood or 7/16"OSB.Uplift load of 93.5 psf at fastener
spacing of 4.63"o.c.with structural sealant in I5/32"
plywood.
20484.4 Aluminum SL150 Max 15"wide,nom 0.032"thick(min.)aluminum snap-lock
standing seam metal panel over min 15132"thick plywood
deck or 7116"thick OSB
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 II Eva ivationRenortC2175 4 odf
Approved for use outside FIVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-86 Evaluation Reports
Other:Uplift load of 45.0 psf at clip spacing of 24"o.c.and FL20484 R1 AE EvaluatlonReportC2175 4 Ddf
78.5 psf at clip spacing of 6"o.c.in 15/32"plywood or 7116" Created by Independent Third Party: Yes
OSB.Uplift load of 86.0 psf at clip spacing of 6"O.C.with
structural sealant in 15/32"plywood.
20484.5 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32"
thick plywood or 7/16"thick OSB
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 RI II FvaluatlonReportC2175 5 odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-124 Evaluation Reports
Other:Uplift load of 56.0 psf @ fastener spacing of 24"o.c. FL20484 R1 AE Eva luationReoortC2175 5.odf
&124.0 psf @ fastener spacing of 6"a.c. Created by Independent Third Party:Yes
20484.6 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 I1 EvaluaticnReaortC2175 5 odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-88.5 Evaluation Reports
Other: Uplift load of 56 psf for Fastening System 1.Uplift FL20484 R1 AF EvaluationReoortC2175 6.pdf
load of 88.5 psf for Fastening System 2. Created by Independent Third Party:Yes
https://www.floridabuilding.orWpr/pr_app_dtl.aspx?parain=wGEVXQwtDgsJ9a49YAgX... 10/12/2019
Florida Building Code Online Page 3 of 3
20484.7 ML150 Max 16.5"wide,min 24 ga.steel standing seam panel over
15/32"thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 11 EvaluationReportC2175 7,pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-124 Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6" FL20484 R1 AE EvaluationRe ortC2175 7.12df
o.c.with 180 seam,self-adhering membrane and fixed clip. Created by Independent Third Party:Yes
20484.8 PBR or R Panel Min 26 ga.,36"wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 II Eva luationRe ortC2175 8.Of
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-161.5 Evaluation Reports
Other:Uplift load of 30.0 psf at fastener spacing of 48"u.c. FL20484 R1 AE FvaluationReportC2175 8.Ddf
and 161.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party:Yes
20484.9 SL175 Max 18"wide, min 24 ga.,snap-lock standing seam metal
panel over 15/32"thick plywood
Limits of Use installation Instructions
Approved for use in HVHZ:No FL20484 R1 II EvaluationReuortC2175 9.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-93.5 Evaluation Reports
Other:Uplift load of 39.8 psf @ clip spacing of 36"o.c.and FL20484 R1 AE EvaluationRe ortC2175 9. df
78,5 psf @ clip spacing of 8"o.c with felt. Uplift load of 93.5 Created by Independent Third Party:Yes
psf @ clip spacing of 12"o.c.with self-adhering membrane.
i Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO empleyer.Coovduht 2007-2013 State of Florida :u Privacy Statement::Actess-bOty Statement::Refund Statement
Under Florida law,email addresses are public records.It you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.Ifyou have any questions,please contact 050.487.1395.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To deterrnine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
momICI zct«r
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgX_.. 10/12/2019
EVALUATION IMPORT OF
UNION CORRUGATING COMPANY
'26 GA. 5V PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 20484.1-R1
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S. Ding St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared Bv:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave., Suite C
Tulsa, OIL 74106
Telephone: (918) 492-5992
FAX: (866) 366-1.543
This report consists of
Evaluation Deport (3 Pages including cover)
Installation Details (1 Page) �������?��Gr�����8
Load Spars Table (I Page) ���°
LP
�:s1y
m ° ` . F
Report No. C2175-1 =
Date: 8.23,2017
FL 20484.1-RI
C2175-1
8.23.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with(5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c.
(Factor of Safety=2) 169.0 psf @ fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" long wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat and rib
Test Standards: Roof assembly tested in accordance with LL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
FL 20484,1-RI
C2175-1
8.23.2017
Page 3 of 3
not applicable in High Velocity Hurricane Zone. Refer to current NOA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory or ASTM EI UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16, Reporting Date 5112J16
EhSt-99E-498 Xtl� Z66S-C6Y-8�a:3MHd
g a LO£SZ ON 31lI1 J-L]",Vj 90LbG ��YSlfil
133WS ONM 'S LOL }sLns'�+v aHis n H 9tz�
3 OO 9Ntivof1mG3 NOINfl '3'6 "0'Hd 'MON11"005 WHYS r w LLa
aaannvanrsm
l3Ndd AS
V r
� 31va As reouaia�sta rrosrra� 'oH � �
P N
x o w wU � max
W a aaLi-:2
Z Of �
zm
Ow�Da2Ov~iz
U O Z t-U
omm Urd
LZW
7 w
Q U � �Ww� sI�~ate
w O W O W Q'O U—'w
U
I �- O 4 mJ jU�W[nQ
c o Z U w
o~ .1Y4QUr�4
H U W m
� UY u7 w U D 2
x u ¢¢w�D<
ao=zwQDU
a
�U w-owa
awm a?oa�03�Nswn4
Z oo¢ u�im ���`F�2
¢9Ln Q wV
u�zozoa
m O
ran a w
diUJ � cn
z I ! cad 0Zw C3 U1fl J�II�d
i�v z
z�� < X <a�a2r��z— ¢cnIr W
a�� I zmz ci �i ui
_ Z z
O
n
Q N O m
Q
I—
U1
Z
o Ln
J
Lq
W
Q
0 ID
0
` 2
V1�
N uO
� I I
� I
o � N
LLI a U
LLJ
I I--
5 ox 3; J o W
lZ 0� oN p
I UZ NV7 N Zz
O� K x
� � O
� Z
W 0 �
3 w N OLn
w r O
Z p Z �a Z Xp
0=
UNION CORRUGATING COMPANY
5Y Panel Uplift Loads
(Min 26 ga,)
Description Fastener Spacing Allowable Uplift
along Panel Length Load
(in) (ps f)
Coverage width: 24" 6 169.0
Panel Fasteners 10 147.2
#10-15 hex head screws with 12 136.3
sealed washer 14 121.7
16 106.5
.Panel fasteners spaced at 12" 18 94.7
o.c. across panel width 20 85.2
through ribs. 22 77.5
--
24 71.0
1�ates:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2_
2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
LING�$ fe®
° •S
a� G
,Z m
a LU
cg
- `•. O.
1216 N Lansing Ave.,Suite C �. 'Y' t _`' Bala SockaLingam,Ph.D.,P.E.
Tulsa,Ok 74106 FL 62240