Loading...
HomeMy WebLinkAboutMetal Sales PSU #30 Underlayment Fl11602-R10- --- - - Bas Home Log In User RegiWatmn Hot Topics Submit Surcharge Stats Fad's d/--7", uct Approval bor Public User erAug, Aaprayst {Menu > 8gaLialien a > AqpyL Se -C �q�io �iLjst > Application Detail L_ FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcotegory Compliance Method FL11602-RIO Revision 2017 Approved Owens Corning Roofing and Asphalt, LLC One Owens Coming Parkway Toledo, OH 43645 (740):321-6345 Greg. Keeter@owenscorning.com Keeler Greg Greg, Keeler*owenscorning.corn Greg Keeler 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Roofing unclerjayrnerrte Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12(31/2020 Validated By John W. Knezevich, PE --' Validation Checklist - Hardcopy Received Certificate of fridependence &1111§221�coi �— tib C[aI PVI i Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM 11226 (physicals) 2009 ASTM 04798 2011 FRSA/TRI April 2012 2012 TAS 117(8) 1995 LJL1897 2012 I Publications Contact Us BLIS Site Map Links Search, Owens Corning Roofing and Asphalt, LLC One Owens Coming Parkway Toledo, OH 43645 (740):321-6345 Greg. Keeter@owenscorning.com Keeler Greg Greg, Keeler*owenscorning.corn Greg Keeler 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Roofing unclerjayrnerrte Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12(31/2020 Validated By John W. Knezevich, PE --' Validation Checklist - Hardcopy Received Certificate of fridependence &1111§221�coi �— tib C[aI PVI i Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM 11226 (physicals) 2009 ASTM 04798 2011 FRSA/TRI April 2012 2012 TAS 117(8) 1995 LJL1897 2012 I Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 10/17/2019 Date Validated 10/1712019 Date Pending FBC Approval 10120/2019 Date Approved 12/10/2019 Of Model, Number or Name Description 111602.1 [Titanium Roof Underlayments Synthetic sheet -type roof undeflayments Limits of Use Approved for use in HVHZ. No Approved for use outside HVHZI Yes Impact Resistant: N/A Design Pressure. +N/Al-45 Other: 1.) The design pressure noted herein pertains to use of a specific underlayment -system beneath foam -on the sytsems. Refer to ER Sect -ion 5.6.3 for details- 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Instailation Instructions FL11602 010 11 Verified By. Robert Nieminen PE -59166 Created by independent Third Party- Yes Evaluation Reports FL11602 R10 AE 201910 FINAL ER %L116ti2- .p Created by Independent Third Party. Yes g_ortW Ug *,. 2601 Stair Zone Road. Tallahassee FL X2399 Phone: 850-487-182 The State of Florida Is an AAJEEO employer. 'ant 2607-2013 State qtDgr':Q,9_. :: EVY—ary Statement ACcas$ i b I I b Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records recivest, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail- It you have any questions, please contact 850.487,139S- *Pursuantto Section 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, P.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official cotimunication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click bgre,. Product Approval Accepts'. = 9::1 �0 = W INEM01 etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE CONSULT CERTIFY Owens Coming Roofing and Asphalt, LLC Evaluation Report 111980.11.WR11 One Owens Coming Parkway FL11602-R10 Toledo, OH 43659 Date of Issuance: 1110312008 (740) 321-6345 Revision 11,10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (20171 Florida Building Code sections noted herein. DESCRIPTION: Titanium"m Roof Underlayments LAseuNG- Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted Herein. CoNTiNusc, COMPLIANCE., This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named Client Constitutes agreement to notify Robert Nierninen, PE. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMC} ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION. Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by. Robert J.M. Nierninen, P.E. The facsimile seat appearing was authorized by Robert Florida Registration No. 59166, Florida DCA AAfE1.983 Nleminea, P.E. on 10/17/2019. This does rvot se— as an eleartmically signed document. CERTIFICATION OF INDEFEINT)WE' 1. NEW ETC, LLC does not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nierninen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nleminen, P,E, are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. @2018 NEMER ETC, LLC ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement-, Titanium"' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations I Conditions of Use set forth herein. Section propa Standard Year 1504-31 Wind Uplift UL 1897 2012 1507.1.1, 8905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, 8905.1.1 Exception rear Strength ASTM D1970 2015 1507.1.1, 71507. 1. 2, 1507.2.9.2 physical Properties ASTM D1970 2015 1507.3.3 Physical Properties MSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull-through resistance TAS 117(8) 1995 Enti Examination Reference Date ERD (TST6049r) Physical Properties 115010,04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05,10 05/14/2010 ERD (TST6049) Physical Properties 135520,06.11 0611512011 ERD (TST6049) ASTM D226 13801008-11 08/11/2011 ERD (TST6049) Wind Uplift 135520,08.11-1 08/12/2011 as (TST1509) ASTM D226 3118010CQQ-003 04126/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 41-OC-19-SSUDL-GI.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM 41970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 1010312017 PR((TST5876) ASTM D1970; Tear strensth OCF-332-02.02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02 1010312017 PRI (TST5878) FRSA/TRi April 2012 (04-12), partial Or -F-343-02-01 11/09/2017 PRI (TSTS878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TSTS878) TAS 117(8); Pull-through OCF-422-02-02 04103/2018 PRI (TST5878) FRSA/TRl April 2012 (04-12), partial OCF-425-02-01 08/13/2018 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-331-02-01 R1 05/0712019 PRI (TSTS878) ASTM D226 / ASTM D4798 OCF-332-02-01 R1 05/07/2019 PRI (T ST5878) ASTM D226 / ASTM D4798 OCF-334-02-01 RI 05/07/2019 PRI (TSTS878) UL1897 13797002 07/10/2019 PRI (TST5878) Tensile adhesion OCF-507-02-01 08/13/2019 ITS (QUA1673) Quality control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 NEMO ETC, LLC Evaluation Report 111980-11.08-RII CerUjImte afAothmizotion #32455 6TH FOITION f2017) f6C NOWIRVNZ EVALUATION FL12602-RIO TitaMurn Roof Undertayments Reviii1on 11:1011712019 Page 2 of 8 PRODUCT DescAiPTION, Asphalt Product Spggification Plant(s) Description 4.1 Titanium"" PSU-30 ASTM D197c) Dubai, UAE & unreinforced polymer modified bitumen material adhered Metal and FRSA/TRI Brentwood, NH to the underside of a polymer -coated, synthetic wove ri April 2012 sheet. The underside is backed with a release film. Unit Titanium PSL3-30 weight 24 lbs/scluare 41 TltaniurnTl UDL-25 FBC 150M.1 Qingdao, China synthetic sheet -type underlayment comprised of a woven yes & R905 -1.I Yes core coated on one side with a polymer coating. Unit No (Exception) Yes weight 2.5 lbs./square 4.3 TitaniumT111 UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment, comprised of a woven Yes & R905.1.1 Canada & core coated on both sides with a polymer coating, Unit Yes (Exceptioni Qingdao, China weight 4.0 lbs./square 4.4 Titanium"UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven SWI—) & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit 5.1 5,2 5.3 5.4 5.5 (Exception) Qingdao, China weight 4.7 lbs./square This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for use in FBC HVHZ jurlsdictions. Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Titanium"' Roof Underlayments may be used with any prepared roof cover where the product Is Specifically referenced within FBC approval documents, If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. if i0, P—f i—ntmm- TAsLE 1: ROOF COVER OPMONS Asphalt Wood Shakes Underlayment Shingles NalwnTile foam-O"Tile Metal &Shmales Slate Titanium PSL3-30 Yes Yes Yes (See 5.5.1) Yes Yes yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Yes Yes yes Titanium UDL-30 Yes ta--esheet!42-ply IBasesheetin7-* SWI—) system) Titanium UDL-50 Yes — No No Yes Yes Yes Evaluation Report 11.19$0.11.08-R11NWO ETC, ULC Certificate ofA4,tharIzation 932455 e EDITION (2017) FBC NOv-HvHz EVALUATION F=602-Rlo Titanium Roof Underlayments Revision 11:1.0/17/2019 Page 3 of a "INIEM01 etc. 6.3.3 Slopes of 4.12 or gl eater. End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the undedayment need only be preliminarily attached pending attachment of the battens. 6,3.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12 -inches, and side (horizontal) laps shall be minimum 25 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a 25 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25 -inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be in accordance with PBG Table 1507.1.1 or 8905.1.1. Secure end laps 4 -inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4 Titanium4 PSI! -313: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM 01970 underlayment in FBG Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium""' PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements. 6.4.2 Nail -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRl April 2012 (04-12), and Owens Corning published requirements. Titanluni'm PSU-30 shall be back -nailed max. 6' o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for the staging limitations_ 6.4.3 Foam -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium' PSU-30 shall be back -nailed max- 6!, o.c_ with 12 ga- galvanized annular rink shank nails through 32 ga-, 1 -5J8 -inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Table 1A for allowable the adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 6.5 litanfurn 2 -Ply System: 6,5,1 The Titanium 2 -Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-3(I, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. NEMO ETC, ULC Evaluation Report 111980.11.08-RII Certili'mte qfAutharkaton #32455 e EDITION (2017) FHC Nilli-RV 14Z EVALUATION FLU602-RIO Titanium Roof Underlayments Revision 11, 10/17/2019 Page 7 of 8 A 6.5-3 Nail tart Tile Applications: For nail -on the Installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRl April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for the staging limitations. 6.5.4 loam -tin Tile Applications. For foam -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable the adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for the staging limitations. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Flaying Jurisdiction in order to properly evaluate the installation of this product. MANUIZACTORING PLANTS: Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. QUALITY Assu"NcE ENTITY- Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 N3 7THIN1111viliff 114 tr#lki .Irma ETC, LLC Evaivation Report 111980.11.09-RI2 Certykate- ofAvthodz&i0n #32455 e" WIT ION (2017) FBC WON -W 114Z EVALUATION F1.11602 -RIO Titanium Roof UndertayinOnts Revision 11:- 1011712019 Page 8 of 8