HomeMy WebLinkAboutBlower door testDate: 11L10
Contractor:
Job Address:
Construction:
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone: 772-462-2165 Farr. 772-4.62-64.43
BLOWLIR DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
-a.- a,v.wcoea6ul.Ype—�'.g6'np9ete
( ) Existing —After Addition
douse infiltration Test Results
CFM (50) = 23 S g SLC Climate Zone 2
Volume= 3 1 f 6o Test Date: _ A: f tir(I c 29
ACH (50) = CFM (50) n 60/Volume=- 34
Passing results must be & ACI1(So) or less Mechanical Ventilation required less than 3 ACN
(pass ( ) Fall
FBc, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (so Pascals). Testing shall be conducted by either individuals as defied in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth n
in Section 489.105 (3)(f), (g) or (i) Oran
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
SBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch W. C. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Comaanv
Company Name: pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with §ection R402.4.1.2 Climate Zone 2.
Signature: '
Printed Name: Martin Klein
License/Certification #: 5061633
BUILDING PERFORMANCE
INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020
-
,�
(877) 274-1274
www.bpl.org
r" .
.�aX-iB<z
Martin Klein
BPI IDA: 5051633
(SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES;
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
lnfiltratim .&.Duct Lcal;ago(IDL) 4262021
BUILDING PERFORMANCE IN5TiTUTE, INC.