HomeMy WebLinkAboutAPPROVED Resisto smooth Florida Building Cpde Online Pa e 1 of 2
Y- p. 0 if � p • � �
BCIS Home li Log In User Registration Hot Topics Submit Surcharge g Stats&Facts I Publications ; Contact Us # BCIS Site Map Links Search E
Q Product Approval
.USER:Public User
m
EBAU"ppmyll Menu> ca' >Application Ust>Application Detail
NZ !. FL# FL2569-1119
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
me Mathieu@soprema,ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema,ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688]ean-Berchmans•Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext3327
me Mathieu @soprema,ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
i jfcoteosoprema.ca
Category Roofing
jSubcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nleminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W.Knezevich,PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL2569 R19 COI Z020 01„CQ,) #EMINEN odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015 -
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL1897 2012
Equivalence of Product Standards
Certified By
h4s://www.floridabuilding.org/pr/pr_app_dtl,aspx?param=wGEVXQwtDgSKQFEnekB 1... 7/29/2020
Florida Buil nline
i
I
-! Sections from the Code
i
Product Approval Method Method 1 Option D
Date Submitted 04/09/2020
Date Validated 04/09/2020
Date Pending FBC Approval 04/14/2020
Date Approved 06/02/2020
a
i
Summary of Products
FL# Model,Number or Name Descriptlon
2569.1 Soprema Roof Underlayments Self adhering roof underlayments
Limits of Use Installation Instructions
it Approved for use in HVHZ:No F1.2569 R19 II 2020 04 06 FINAL ER FL25,62-R19 odf
Approved for use outside HVHZ:Yes Verified By; Robert Nieminen,P.E.PE-59166
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-150 Evaluation Reports
1 other:1.)Refer to ER Section 5 for Limits of Use. 2.)The FL2569 Rig AE 202 6 FINAL FR F 569-R19, df
design pressure noted herein pertains to underlayment Created by Independent Third Party; Yes
systems used beneath adhesive-set tile systems. Refer to ER
Section 5.6.4 for details,
Back Next
Contact Us;;26D1_Blair Stone Road,Tallahassee FL 32389 RUggLL 50-487-1824
The State of Florida is an AA/EE0 employer.Copyright 2007-a01a_S�tate of Florida.;;Privacy Statement;; cce a nt;;Refund Statement
Under Florida law,email addresses are public records,if you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Uses rtment with an email address If they have one.The
ema 4s provided may be used for official communication with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click here,
Product Approval Accepts
Credit Cary
✓�t`3
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 1... 7/29/2020
NEMOJetc.
Certificate of Authorization#31455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION .O.
Soprema,Inc. Evaluation Report S18010.06.09-R17
1640 rue Haggerty FL2569-1119 —
Drummondville,Quebec J2C 5138 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 17:04/06/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the
product(s),the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in Its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
i
This Evaluation Report consists of pages 1 through 8.
Prepared by:
.sib:
ST —.Q�•7r "
Robert J.M. Nieminen,P,E, "'•.,oT_�,.� terra: The facsimile seal appearing was authorized by Robert
f'',4b'.^^=• �t'' ,•' Nieminen,P.E.on D4/0 612 02 0.This does not serve as an
Florida Registration No.59166,Florida DCA ANE1983
"S�aN,,,:ien•` elecironically signed document.
CERTIFICATION OF INDEPENDENCE:
1, NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
5. This is a building code evaluation. Neither NEMOI etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically
for that purpose.
m2019 NEMD ETC,LLC
N�NIEMC)Jetc.
ROOFING COMPONENT + •
Z w
_.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprelna, have demonstrated compliance with the
following sections of the 61s Edition (2017)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
Section-- Pro "e 5tand'ard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,1507.2.9.2,R905.1.1, Physical Properties ASTM D1970 2015
R905.2.8.2
1507.3.3,R905.3.3 Physical Properties FRSAMI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
mtnat
Entity_ a Ex" ion Reference-. D'ate ..
ERD(TST6049) Wind Resistance 2778,07,05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014
ERD(T5T6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) 544870,04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) 544870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SDPC-SC14045.05.17-RI 06/07/2017
-' M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018 —
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging _ 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(T5T6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04,A 03/12/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 07/19/2017 _
MEMO ETC,LLC Evaluation Report$18010.06.09-R17
Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R19
soprema Roof Underlayments Revision 17:04/06/2020
Page 2 of 8
1
x
Ur4NEM01 etc.
Prg, Up.t , : Spy+ifrcatton ;.'. ._ .., Plant[sy.,. Description
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,
FRSA/TRI April 2012 SBS modified bitumen roof underlayment
4.2 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4A Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4,7 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4,8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Wadsworth,OH SBS modified bitumen roof underlayment
4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Protection Sheet Wadsworth,OH SBS modified bitumen roof underlayment
4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
f Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4,11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
HT Wadsworth,OH SBS modified bitumen roof underlayment
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
Smooth Seal HT Wadsworth,OH SBS modified bitumen roof underlayment
4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced, —
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Eave&Valley Protector Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.15 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
WATER DEFENDER Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.16 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.17 Colphene FR GR ASTM D1970 and Gulfport,MS self-adhering,fiberglass reinforced,granule-
FRSA/TRI April 2012 Wadsworth,OH surfaced,SIBS modified bitumen roof underlayment
MEMO ETC,I.LC Evaluation Report S18010,06.09-R17
Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1119
soprema Roof Underlayments Revision 17:04/06/Z020
Page 3of8
I
E
NNEMOletc.
LIMITATIONS. a
5.1 This is a buildingcode evaluation. Neither MEMO ETC LLC nor Robert Nieminen, P.E.are,i"
n any way,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
3
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
' 5.5 Allowable Roof Covers:
f _ TABL£1' RQOF COVERPYIONS
jWood or
Untlerl�ment" hg nh es N Tile n To Tm OComposite
n Sf�akes& CSlate or
Y :Metal:' omposite"
Shingles=
Slate
Lastobond TU HT Yes Yes Yes See 55.1 Yes Yes Yes
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes
Lastobond 195
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
TopShield ICE&WATER DEFENDER/
RESISTO L61244
Lastobond Smooth Seal HT/Grip-
Rite Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes No No Yes Yes
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
TAi3LE ALLDWEI6LE T[LE,4AEStVE`/UNDERLAYMeNL COMBINATION51
Underayment Adhesive Flarlda Product-Approval
Dupont TILE BOND'"" FL22525
Lastobond TU HT
ICP Adhesives Polyset®AH-160 FL6332
s Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report S18010.06.09-R17
Certificate of Authorization#32455 6rH EDITION(20171 FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 4 of 8
I
Ur4NEMOletc.
5.6 Allowable Substrates:
w-CABLE SUBSTRAT60P
Undepa`yment. Primer Subs;rates .
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA (Optional)ASTM D41, plywood,OSB,Southern Yellow
SMOOTH PLY 40,Lastoband Shield HT,Lastobond Pro HT-S, Elastocol Stick,Elastocol Stick pine(SYP)
EnviroShleld,Lastobond TU HT,Lastobond Eaves Protection Zero
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236,
Grip-Rite Eave&Valley Protector,TopShield ICE&WATER
DEFENDER,RESISTO LB1244,Lastobond Smooth Seal HT or ASTM D41 structural concrete
Grip-Rite Smooth Seal HT
1 (Optional)ASTM D41 Plywood
Colphene FIR GR
ASTM D41 structural concrete
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Dens Deck Prime;SECU ROCK
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Gypsum-Fiber Roof Board;
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, (Optional)Elastocol Stick Zero ASTM D226,Type I or II felt;
Grip-Rite Eave&Valley Protector,TopShield ICE&WATER Sopra-G;Modified Sopra-G
DEFENDER,RESISTO LB1244,Lastobond Smooth Seal HT,
Grip-Rite Smooth Seal HT or Colphene FR GR
Existing sand-surfaced,glass-
RESISTO LB1236,Grip-Rite Eave&Valley Protector or RESISTO EXTERIOR PRIMER fiber surfaced,mineral-surfaced
TopShield ICE&WATER DEFENDER or film-surfaced roof
liI I underlayment*
" Final acceptance of any existing substrate in a reroof(tear-off)installation!sat the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite
Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.6.1 Soprema recommends priming with Elastocol Stick; Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.6.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D,Testing Application Standard TAS 114,Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings,base sheet shall be attached per minimum
codified requirements. For installations under foam-on tile systems(Lastobond TU HT only), base sheet shall be
attached in accordance with FRSA/TRI April 2012(04-12)or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12)and are used in foam-on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012(04-12)or FBC 1609 for determination of design wind pressures.
NEIVIO ETC,LLC Evaluation Report 516010.06.09-R17
Certificate ofAuthoriration#32455 6-EDITION(2017)FOC NON-HVHZ EVALUATION F1.2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 5 of 8
I
I
U(4
NEMO I etc.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#2 Maximum Design Pressure=-67.5 psf:
f Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction. —
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#3 Maximum Design Pressure=-120.0psf:
Deck: Min. 15/32-11nch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction,
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered;thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-
laps.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#4 Maximum Desi n Pressure=-150.0 Psf:
Deck: Min, 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#5 Maximum Design Pressure=-60.0 psf: —
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three(3),equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps
5.6.5.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf. —
NEW ETC,LLC Evaluation Report S18010.06.09-R17
Certificate of Authorization#32455 671 EDITION(20171 FBC NON-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17:04/06/2020
Page 6 of 8
i
I
{
{1
I
UTY
NEMO I etc.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet ar
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
{, Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609, In this case,Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
I marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
I (January 2016)for Zone 2/3 enhancements.
i
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days
after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield,Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT small not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage limitations(TA5103 per FRSAZTRI April 2012(04-12)1:
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
a..;m.. .... r. R Q2Q1LENSTALLATIN�t;, .. ..
Maximum
Underlaymenf: The Profile ;=5taging Method
Flat Max. 10-tile stack 6:12
Lugged Max. 10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT x
j Lugged w,
i
I
Colphene FR GR Flat Max. 10-tile stack 5:12
Lugged Max. 10-tile stack 6:12
NENIO ETC,LLC Evaluation Report 518010.06.09-1137
Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1119
Soprema Roof Underlayments Revision 17;04/06/20ZO
Page 7of8
i
NEnno 1 etc.
6.1 Soprema Roof Underlayments shall be installed in accordanceµ with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER(if applicable).
6.2.1 Installation of RESISTO LB1236,Grip-Rite Eave&Valley Protector orTupShield ICE&WATER DEFENDER self-adhering
underlayment in a reroof(tear-off)application atop an existing underlayment(per Table 2)requires priming of the
existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof(tear-off)
installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to
the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 La.stobond TU HX, Lastapand Shield, Eastoband Pro HT% RESISTO sX SlMCtOTH PLY 40 Lastobond Shield WT,
..
Lastobond9 Pro WT S,EnuiroShleld,Lastobond Eaves Protection Sheet,Lasttobond 195,Lastobono Eco,Lgstobond';
S Booth Seal WT,,GXip Mite Smooth Seaf HT, REMSITO LB.1236,Grlp Rite Eaive&Valley Protector;TopShield ICE&
WATER;DEFENQER,RE51ST0 LB1244 ar CalpheneFR GR
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507,11 or FBC
Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published
requirements.
6.3.2 Tile Applications Lastobond TU HT or Col .hene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema
published requirements.
For mechanically fastened the roofing over a 2-ply system, consisting of Base Sheet and Self-Adhered Membrane,
fastening of the ASTM D226,Type II base sheet shall be in accordance with Soprema requirements,but not less than
that the densities set forth in FRSA/TRI April 2012(04-12),Table 1.
For foam-on tile applications(Lastobond TU HT only),reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment, See
Table 3 herein,and Soprema published requirements for tile staging,
$U11piNC1PERl ITw IiQtJOMENi�;
...
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of —
this product.
S M'NUFACTUR1NG PLANTS
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements.
Refer to Section 4 herein for product&production locations having rnet codified physical properties specifications.
Q11;4LiTY A55URf�NCE ENTITY
UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report S18010.06.09-1117
Certificate of Authorization#32455 61"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17:04/06/2020
Page 8 of 8