Loading...
HomeMy WebLinkAboutAPPROVED Parker-FL Approval-Extreme Metal.pdf 8/20/2020 Florida Building Code Online Business & Professional Regulation 9CIS Home tog In User Registration Hot Topics Submit Surcharge Stilts&Facts Pubhcations Contact Us BCIS Site Map Links Search dbpr M Product Approval USER:Public User Product Approval Menu>Prodwa or Application Search yohcatvon List>Application Detail FL# FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest,RE, Validation Checklist-Mardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Zdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https:llwww.floridabuilding.org/prlpr_app_dU.aspx?param--wGEVXQwtDgv2aBQpHpOOe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113 8/20/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/26/2017 Date Approved 10/10/2017 summary of Products FL# Model,Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use In HVHZ: No FL17022_R7 11. FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2-"5V Crimp"(R6) 0.032"Aluminum, 3/8" Rib height,21"wide lapped roof panel, mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17Q22 R7 11 FL 17022. M Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: +N/A/Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5_V CRIMP 0.032 ALLIM ssrp�f assembly in compliance with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3- "1.5" Mechanical Seam" (115) 1.5"rib height, 16"wide, 24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 Ii FL 17022.3 1,5 MECHANICAL Approved for use outside HVHZ:Yes seam 24gassr pdf Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL method listed in this report and applicable code sections of seam 24ga ssr•pd_f FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4-"1.5" Mechanical Seam"(R5) 1.5"rib height, 16"wide, 0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 11 FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr,pdf Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17QZ2.4 ME HAN IAL SEAM method listed in this report and applicable code sections of ALUMINUM ssr pdf FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.5 5-"1 in. Nail Strip"(R5) 1"rib height, 16"wide, 26 gauge steel,standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No FL17022 R7 11 FL 17022.5 1.0 NAILSTRIP 5sr.pdf Approved for use outside HVHZ:Yes Verified By; Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022-5 1.0 NAILSTRIP ssr.p�, of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes https:/lwww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 213 8/20/2020 Florida Building Code Online method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 6-"i in.Nail Strip"(Its) I"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 I1 FL 17022.6 1.0 NAIL STRIP_Q.032 Approved for use outside HVHZ:Yes ALUM ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 method listed in this report and applicable code sections of ALUM ssrodf FBC. Refer to manufacturer's Installation Instructions. Created by Independent Third Party:Yes 17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssrpd Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.8 8 - "EMAX Rib" (115) 29 gauge steel, lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssrpdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 177022.8 EMAX fib ssr p-0—f of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.9 9-"PBR MAX" (115) 26 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.9 PBR RIB_ 55r.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations I FL17022 R7 AE Fl-17022.9 P r.pr�f of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes method listed in this report and applicable code sections of FBC. Refer to manufacturers installation instructions. C Contact Us::2§91 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824 The State of F3orlda ks an AA/EEo employer..Qmynaht 20Q7-2613 State of Ffarlda.::Pdyaw Statement::Accessiblilty Statement::Refund Statemn et Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request.do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emaifs provided may be used for official communication with the licensee.However email addresses are public record.IF you do not wish to supply a personal address,please provide the Department with an email address which can be made i vallable to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick hem. Product Approval Accepts: ® ® o� M' I lI' Gard Safe https://www.floridabuilding.orgtprlpr_app_otl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvQQveeg%3d%3d 3/3 Product . . 2160 SW Poma Drive Palm City, FL 34990 772)B72-8034 :Florida Product Approval1 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 9151 Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -96 PSF Main field -97.25 PSF Perimeter FASTENER SPACING 6" O.C. 6" O.C. SEAM ADHESIVE Not required 3/16" continuous bead (see details) Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06& UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 EQUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safety 2:1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial 1"214n agy company manufacturing or distributing products under this evaluation. ����t,( •'��j,y���r,� Locke Bowden,P.E.is not owned,operated,or controlle�yJmRi thineturer,or distributing products under this report. 40 • '� • seal '• STATE OF E Limitations: 1.Undedayment to be compliance with current Florida Building Code(FBC)2017 61 ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 61'ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3.Compliance Method: 1-D 4.Engineering analysis for"project specific approval by local authorities wfJurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 61'ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details 16" 314+ " Panel Profile 16" o.G. �.; K� Deck: -15132"or greater Plywood,or -VVbod plank Integral Snap Lock For NETHGD 2: Apply 3116"Bead Sostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. per Table"A' Pancake Head V4bod Screw (Typical Fastening Pattern Across Width) FL 17022.6 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel ----��—_-- — --�--_ Q 1 i Seam Adhesive Application: Deck: For Method 2 -15J32"or greater Plywood, or Apply 3116"Bead Bostik 915Tm Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A") Isometric View