HomeMy WebLinkAboutdavid rogers engineering1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND
BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD
LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING
DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED
BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS
ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2.
4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM Al003/A1003M-15.
5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE
RESPONSIBILITY OF THE OWNER.
6. ROOF AND WALL SHEATHING SECURED WITH #12-140" SELF -DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX.
7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF -DRILLING SCREWS.
8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER.
9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH.
10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL.
10'-2" 2' -6"-
-----------------------------------------WINDOW
ROLL -U
DOOR
i
i
i
i
L______
-8
NOTES:
SUB -GRADE SOILS:
-TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION
R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION
CONCRETE:
-MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
-ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE
DESIGNED TO SLOPE AWAY FROM THE STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
-MINIMUM GRADE 40 STEEL
-REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
-THE REBAR IS BENT COLD
-THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED
6 -BAR DIAMETERS: AND
-REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT
EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL
CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
-COVER:
-2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY
IN CONTACT WITH SOIL OR WEATHER, AND 14" ELSEWHERE. REBAR EMBEDDED IN
GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE
GROUT, AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL.
REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING
GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO
EARTH OR WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR
WEATHER.
GALVANIZATION:
-METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY
EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153,
CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
,MIN. 2,500 PSI 4" CONCRETE SLAB WITH 10GA. W.W.F. (OR
FIBER MESH) AND 12"02" REINFORCED FOOTER PERIMETER
---------------------------------------------------------------------------
WINDOW
10'-2" —2'-6" I 12'-
4"x5j" EXPANSION ANCHOR WITHIN 6"
OF EACH POST/TRUSS ALONG SIDES
AND EVERY OTHER END -WALL POST
2" MIN. --I H- .-BASE RAIL
I I—III—III—I I
2,500 PSI 4" CONCRETE
SLAB WITH 10GA. W.W.F.
I--12„ OR FIBER MESH
(2) #5 REBAR ® 6" O.C.
MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM
CAPACITY 500 PSF(TYP.) 12" OVERLAP SPLICE
CONCRETE FOUNDATION /BASF RAIL
ANCHOR DETAIL
2 5" PLAN VIEW DOOR FRAMING
" RECESS
4
DOOR WIDTH
ELEVATION VIEW
DOOR FRAMING
T RECESS
•75"J 4„ DOOR WIDTH
OPTIONAL ROLL -UP DOOR
CONCRETE SPLASH -GUARD RECESS
�12"x12" REINFORCED FOOTER
----------------- SWINGING
DOOR WINDOW
5 3'-0" -2 ---4-2'-6
2'-6" I-
0'-0"
CODE VERSION
FBC 2017 6th Edition,
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II -B
RISK CATEGORY
I
FIRE PROTECTION
INONE
FIRE SUPPRESSION SYSTEM
INONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-150mph
INTERNAL PRESSURE COEFF, I+/- 0.18
�Z
i
0
I�
I
i
i
i
i
� o
ROLL4UP
DOOR
i
i
i
i
0'-2
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
0
I
MTB
7/30/20
702 Anita St., Ft. Pierce
501 X 24'W X 14'H
_\CENSE
NO. 64608 E 2
i 'n STATE OF •4
Digitally signed
0 by Matthew
Baldwin
Date: 2020.07.30
15:50:16 -04'00'
z Matthew T. BaldWin P.E_
Q Florida License #64608
Sheet:
CA -1 OF 4
IMPORTANCE FACTOR 1.0
ROOF DEAD LOAD 10PSF
x
ROOF LIVE LOAD 20PSF OR 3001b P.L.
O
I
FLOOR DEAD LOAD 1OPSF
FLOOR LIVE LOAD 50PSF
"R"RATING OF WALLS,FLOOR,ROOF N/A
MODULES PER BUILDING 1
HURRICANE PROTECTION USAGE NO
HURRICANE SHELTER USAGE NO
SQUARE FOOTAGE 11,200 SQ. FT.
REVISIONS
REV DESCRIPTON I DATE I BY
�Z
i
0
I�
I
i
i
i
i
� o
ROLL4UP
DOOR
i
i
i
i
0'-2
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND
THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
0
I
MTB
7/30/20
702 Anita St., Ft. Pierce
501 X 24'W X 14'H
_\CENSE
NO. 64608 E 2
i 'n STATE OF •4
Digitally signed
0 by Matthew
Baldwin
Date: 2020.07.30
15:50:16 -04'00'
z Matthew T. BaldWin P.E_
Q Florida License #64608
Sheet:
CA -1 OF 4
ROLL -UP
DOOR
ROLL -UP
DOOR
24'-0" 24'-0"
FRONT END WALL REAR END WALL
LEFT SIDE WALL
D
Aga
CAMM ERE
CODE INFORMATION
MAX.
FBC 2017 6th Edition
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
O.C.
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-150mph
EXPOSURE
2'-6"
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
2'-6"
1.0
ROOF DEAD LOAD
0
WINDOW _I
N
ROOF LIVE LOAD
20PSF OR 300Ib P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF N/A
0
WINDOW
N
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
m
SWINGING
REVISIONS
10'-2"DOOR
10'-2"
n' -n^
LEFT SIDE WALL
D
Aga
CAMM ERE
CODE INFORMATION
CODE VERSION
FBC 2017 6th Edition
ASCE-7-10
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-150mph
EXPOSURE
B
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
10PSF
ROOF LIVE LOAD
20PSF OR 300Ib P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,200 SQ. FT.
REVISIONS
MTB
7/30/20
702 Anita St., Ft. Pierce
50'L X 24'W X 14'H
W
O.a MAX_
PRINTED COPIES OF THIS DOCUMENT ARE NOT CD
CONSIDERED SIGNED AND SEALED AND THE z
SHA AUTHENTICATION CODE MUST BE VERIFIED
2'-6" 2'-6" ON ANY ELECTRONIC COPIES
WINDOW WINDOW LL
N N
LZ
10'-2" 24'_6^ 10'-2" LLJ
Matthew T. Baldwin P.E.
LLJ Florida License #64608
Lei
RIGHT SIDE WALL C Sheet: CA -2 OF 4
o
v
i?
vRO
CAMWMANMHME
CODE INFORMATION
FBC 2017 6th Edition,
CODE VERSION
ASCE-7-10
MANUFACTURER CARPORTS ANYWHERE
BUILDING TYPE UTILITY STRUCTURE
CONSTRUCTION TYPE II -B
RISK CATEGORY I
UP
DOOR
FIRE PROTECTION NONE
FIRE SUPPRESSION SYSTEM NONE
OCCUPANCY UTILITY, U
WIND SPEED Vult-150mph
EXPOSURE B
ENCLOSURE ENCLOSED
INTERNAL PRESSURE COEFF. +/- 0.18
IMPORTANCE FACTOR 1.0
24'-°•
FRONT END WALL
24-0
ROOF DEAD LOAD IOPSF
ROOF LIVE LOAD 20PSF OR 3001b P.L.
REAR END WALL
FLOOR DEAD LOAD 1OPSF
0
I
Y
FLOOR LIVE LOAD 5OPSF
"R"RATING OF WALLS,FLOOR,ROOF N/A
MODULES PER BUILDING 1
HURRICANE PROTECTION USAGE NO
HURRICANE SHELTER USAGE NO
SQUARE FOOTAGE 1,200 SQ. FT.
REVISIONS
REV DESCRIPTON DATE BY
WINDOW
SWINGING
DOOR
WINDOW
DRAWN BY: MTB
DATE: 7/30/20
LOCATION:
702 Anita St., Ft. Pierce
SIZE: 501 X 24'W X 14'H
w
0
z
LLJ
W
Matthew T. Baldwin P.E.
Florida License #64608
50._0. I
LEFT SIDE WALL
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SHA AUTHENTICATION CODE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES
WINDOW WINDOW
I- 60'-0' I
RIGHT SIDE WALL
0
_
Sheet: CA -3 OF 4
MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH SECURED TO WALL POST WITH
(4)#12-14xi" SELF—DRILLING (4)#12-14xi" SELF—DRILLING
SCREWS SCREWS
71� /— BASE RAIL NIPPLE TOT
62"x2"x2" 16 GA. ANGLE CLIP
"
SECURED WITH #12-14x "
NIPPLE TO SC
BASE RAI SELF—DRILLING SCREWS
POST TO BASE RAIL
CONNECTION
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF—DRILLING SCREWS
NON-STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
INTERIOR
#12-14xi" SELF—DRILLING
SCREWS ® 10" O.C. MAX.,
3" MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX.
FROM CORNERS VERTICALL`
EXTERIOR
DOOR FRAME TO POST
CONNECTION
END POST TO BASE RAIL
CONNECTION
It
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF—DRILLING SCREWS
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF—DRILLING SCREWS
SINGLE OR DOUBLETS
HEADER
INTERMEDIATE POST TO
HEADER/BASE RAIL/OR HEADER CONNECTION
WINDOW RAIL DETAIL DETAIL OPTION 1
2"x2"x2" 16 GA. ANGLE CLIP SECURED
WITH (4) #12-14xj" SELF—DRILLING
SCREWS
VARIES
STD. MAX. SPACING
3" MIN.
4 j STD. MAX. SP CING
m VARIES
> SIDE WALL ROLL -UP
DOOR/FRAME OUT
HEADER DETAIL
INSTALL PER MANUFACTURERS INSTRUCTIONS
#14x1" SELF—DRILLING
SCREWS ® 6" O.C. MAX.
& 6" MAX. FROM CORNERS
ROLL -UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
- 150 Mph
ROOF
+19.3/-41.4
FL27402.1 —R1
WALLS
+20.0/-22.2
NONE
DOORS
+20.0/-22.2
FL27403.1
WINDOWS
+20.0/-22.2
Vult-150mph
SWINGING DOOR
1
2
3
407 STEEL DOOR
4
5
ZONE
+9.3
-21.9
+12.3
-35.1
+19.3
-41.4
+ 18.8
-21.9
+20.0
-22.2
26 GAUGE ROOF SHEATHING SECURED WITH
(1)#12-14xj" SELF—DRILLING SCREWS
'2-1-2-1' (6" O.C. (9" O.C. MAX.))
1" 16 GAUGE FURRING CHANNEL
48" O.C. MAX. SECURED WITH
(2)#12-14x1" SELF—DRILLING
SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTIO
VERTICAL SHEATHING OPTION
2 All IPPLE TO
TRUSS
1 "x2j" 16 GA.
EMINIU—CHANNEL BRACE, MIN.
MUM
24" UP TO 7' POST, 0
48" OVER 7' POST. MIN.
45' TO MAX. 60' FROM
HORIZ. (EXCLUDE
END—WALLS). SECURED
WITH (4)#12-14xi"
SELF—DRILLING SCREWS.
6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xi" SELF—DRILLING
SCREWS
BOX SAVE RAFTER TO
POST CONNECTION DETAIL
TO TRU
PPLE
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
12-14xi" SELF—DRILLING
EWS
SINGLE OR DOUBLETS
HEADER
HEADER CONNECTION DETAIL
OPTION 2
MINIMUM 6" TS NIPPLE.
NIPPLE SECURED TO WALL
POST WITH (4)#12-14xi"
SELF—DRILLING SCREWS
POST TO TRUSS
CONNECTION
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SHA AUTHENTICATION CODE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1 —R1
I
Hampton Rib Roof Panel
NONE
WALL SHEATHING
Carports Anywhere
FL27403.1
U
Hampton Rib Wall Panel
Vult-150mph
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
HURRICANE PROTECTION USAGE
407 STEEL DOOR
HURRICANE SHELTER USAGE
ROLL—UP DOOR
JANUS INTERNATIONAL CORPORATION
FL21450.3
REVISIONS_
SERIES 3100
WINDOW
POCOHONTAS ALUMINUM COMPANY, INC.
FL12940-R5
MODEL 10OVS
_� lid ��� � 1►���Ji l
CODE VERSION
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCYUTILITY,
U
WIND SPEED
Vult-150mph
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.18
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,200 SQ. FT.
REVISIONS_
awvwry HY: MTB
DATE: 7/30/20
LOCATION: 702 Anita St., Ft. Pierce
SIZE: 501 X 24'W X 14'H
J
Q Matthew T. Baldwin P.E.
< Florida License #64608
i; i W
Sheet: CA -4 OF 4