Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
a FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JBM.PROPERTIES- COQUINA AVE PROJECT Builder Name: JBM PROPERTIES Street: 6906 COQUINA AVENUE Permit Office: ST'LUCIECOUNTY - City, State', Zip: FORT PIERCE, FL ,.34951 Permit Number. Owner. Jurisdiction: • ST LUCIE COUNTY .Design Location: FL, Fart Pierce County. ' St Lucie (Florida Climate Zone 2 ) 1. New construction or eAstind New (From Plans) 9. Wail Types (1736.0 sgft) Insulation Area. a. Concrete Block - Int Insul, F)derior R=4.1 1484.00 fN 2. Single family or multiple family Single-family b. Frame: Wood, Adjacent R=11.0 252.00 ft' 3. Number of units, if multiple family 1 c. N/A R=' ft' 4. Number of Bedrooms 4 d' N/A 1o. Ceiling Types. (1776.0 sgft.) R= ft Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1776.00 ft' 6. Conditioned floor area above grade (ft9 1776 b. N/A R= ft' ft' c. N/A R= Conditioned floorarea below grade (fP) 0 11 Ducts R ft' 7. Windows(189.2 sgft.) Description Area a. Sup: Attic, Ret Attic, AH: Garage 6 150 a. U-Factor. SgI, U=0.65 189.20 ft' SHGC: SHGC=0.25 12. Cooling systems kBEfficiency _ b. U-Factor. N/A ft2 a. Central Unit 36.0 38.0 SEER:16.00 SHGC: c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtuthr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1776.0 sgfL) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1776.00 ft' b. Conservation features b. NIA R= ft' None c. N/A R= ft' A5. Credits None Total Proposed Modified Loads: 69.18 PASS Glass/Floor Area: 0.107 Total Baseline Loads: 61.88 I hereby certify that the plans and specifications covered by Review of the plans and QFilGS�9� this calculation are in compliance with the Florida Energy specifications covered by this indicates Code. calculation compliance yn A with the Florida Energy Code. PREPARED BY- J SU( CSu`'<1J Before construction is completed t7 DATE: 2-7-20 this building will be inspected for compliance with Section 553.908 c9 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7,00 ACH50 (R402.4.1.2). 2/5/2020 11:57 AM EnergyGauge® USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FOCw R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: JBM PROPERTIES- COQUIN Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1776 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: JBM PROPERTIES Rotate Angie: 0 Street: 6906COQUINAAVENU Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Ebsting: New (From Plans) Comment: CLIMATE J Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1776 16516.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 4 156 1450.8 No 0 1 1 Yes Yes Yes 2 BATH 3 48 446.4 No 0 1 Yes Yes Yes 3 CLST 4 14 130.2 No 0 1 No Yes Yes 4 LAUNDRY 42 390.6 No 0 1 No Yes Yes 5 DINING 160 1488 No 0 1 Yes Yes Yes 6 KITCHEN 208 1934A Yes 0 1 Yes Yes Yes 7 BEDROOM 3 143 1329.9 No 0 1 1 Yes Yes Yes 8 CLST 3 14 130.2 No 0 1 Yes Yes Yes 9 CLST 2 12 111.6 No 0 1 No Yes Yes 10 BEDROOM 2 156 1450.8 No 0 1 1 Yes Yes Yes 11 BATH 2 45 418.5 No 0 1 Yes Yes Yes 12 HALLWAY 83 771.9 No 0 1 No Yes Yes 13 LINEN 2 4 37.2 No 0 1 No Yes Yes 14 M WIC 49 455.7 No 0 1 No Yes Yes 15 LINEN 14 130.2 No 0 1 No Yes Yes 16 M BATH 55 511.5 No 0 1 Yes Yes Yes 17 MASTER BEDROO 285 2650.5 No 0 1 1 Yes Yes Yes 18 FOYER/GREAT RO 288 2678.4 No 0 1 Yes Yes Yes 2/5/202011:57 AM EnergyGauge& USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 4 25 It 0 156 ft' __ 1 0 0 2Slab-On-Grade Edge Insulation BATH 3 8 ft 0 48 ft' — 1 0 0 3 Slab -On -Grade Edge Insulation CLST 4 1 ft 0 14 ft' __ 1 0 0 4 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 42 ft' __ 1 0 0 5 Slab -On -Grade Edge Insulation DINING loft 0 160 ft' __ 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 13 ft 0 208 ft' — 1 0 0 7Slab-On-Grade Edge Insulation BEDROOM 3 16 ft 0 143 ft' __ 1 0 0 8Slab-On-Grade Edge Insulation CLST 3 2 ft 0 14 ft' — 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 12 ft' __ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 2511 0 156 ft' __ 1 0 0 11Slab-On-Grade Edge Insulation BATH 2 5 ft 0 45 ft' __ 1 0 0 12SIab-On-Grade Edge Insulation HALLWAY 1ft 0 83 ft' — 1 0 0 13SIab-On-Grade Edge Insulation LINEN 2 1 ft 0 4 ft' 1 0 0 14SIab-On-Grade Edge Insulation M WIC 1 ft 0 49 ft' __ 1 0 0 15SIab-On-Grade Edge Insulation LINEN 1 ft 0 14 ft' __ 1 0 0 16SIab-On-Grade Edge Insulation M BATH 5 ft 0 55 ft' — 1 0 0 17SIab•On-Grade Edge Insulation MASTER BEDRO 344 0 285 f' __ 1 0 0 18SIab-On-Grade Edge Insulation FOYER/GREAT R 16 R 0 288112 — 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1924 ft' Oft' Medium N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1776 ft' N N 2/5/202011:57 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 4 30 Blown 156 ft2 0.1 Wood 2 Under Attic (Vented) BATH 3 30 Blown 48 W 0.1 Wood 3 Under Attic (Vented) CLST 4 30 Blown 14 ft2 0.1 Wood _ 4 Under Attic (Vented) LAUNDRY 30 Blown 42 ft- 0.1 Wood 5 Under Attic (Vented) DINING 30 Blown 160 ft- 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 20B fN 0.1 Wood _ 7 Under Attic (Vented) BEDROOM 3 30 Blown 143 ft2 0.1 Wood _ 8 Under Attic (Vented) CLST 3 30 Blown 14 ft2 0.1 Wood _ 9 Under Attic (Vented) CLST2 30 Blown 12 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 2 30 Blown 156 ft2 0.1 Wood _ 11 Under Attic (Vented) BATH 2 30 Blown 45 ft2 0.1 Wood 12 Under Attic (Vented) HALLWAY 30 Blown 83 ft2 0.1 Wood 13 Under Attic (Vented) LINEN 2 30 Blown 4 ft2 0.1 Wood 14 Under Attic (Vented) MWIC 30 Blown 49 ft2 0.1 Wood 15 Under Attic(Vented) LINEN 30 Blown 14 ft2 0.1 Wood 16 Under Attic (Vented) MBATH 30 Blown 55 ft2 0.1 Wood 17 Under Attic (Vented) MASTER BEDRO 30 Blown 285 ft2 0.1 Wood 18 Under Attic (Vented) FOYERIGREAT R 30 Blown 288 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block- Int InstBEDROOM 4 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block- Int InsiBEDROOM 4 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 _ 3 W Exterior Concrete Block - Int Insul BATH 3 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 _ 4 S Garage Frame -Wood BATH 3 11 6 0 9 4 56.0 ft2 0 0.1 0.6 0 _ 5 S Garage Frame -Wood LAUNDRY 11 7 0 9 4 65.3 ft2 0 0.1 0.6 0 _ 6 N Exterior Concrete Block- Int Insul DINING 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0 _ 7 N Exterior Concrete Block - Int Insul KITCHEN 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 _ 8 S Exterior Concrete Block- Int InstEEDROOM 3 4.1 11 0 9 4 102.7 ft2 0 0 0.6 0 9 W Exterior Concrete Block- Int InsuBEDROOM 3 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block- Int Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 _ 11 E Exterior Concrete Block- Int InsLSEDROOM 2 4.1 13 0 9 4 121.3 ft2 4 0 0.6 0 _ 12 S Exterior Concrete Block- Int Insu8EDROOM 2 4.1 12 0 9 4 112.0 ft2 4 0 0.6 0 _ 13 E Exterior Concrete Block- Int Insul BATH 2 - 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _ 14 E Exterior Concrete Block- Int Insul M BATH 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _ 15 N Exterior Concrete Block- Int InsuMASTER BE 4.1 18 0 9 4 168.0 ft2 0 0 0.6 0 _ 16 E Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 17 S Exterior Concrete Block- Int lnsuFOYER/GRE 4.1 16 0 9 4 149.3 ft2 0 0 0.6 0 18 W Garage Frame -Wood FOYER/GRE 11 14 0 9 4 130.7 ft2 0 0.1 0.6 0 215/202011:57 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 2 _ 3 4 5 _ 6 _ 7 8 9 10 11 N 1 Metal W 3 Meted N 6 Metal N 7 Metal S 8 Metal S 12 Metal E 13 Metal E 14 Metal E 16 Metal S 17 Metal S 17 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single La E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 N 15.0 ft- 0.65 0.25 N 6.0 ft2 0.65 0.25 N 40.2 ft2 0.65 0.25 N 15.0 ft2 0.65 0.25 N 15.0 ft2 0.65 0.25 N 15.0 W 0.65 0.25 N 9.0 ft2 0.65 0.25 N 9.0 ft2 0.65 0.25 N 20.0 ft2 0.65 0.25 N 25.0 ft- 0.65 0.25 N 20.0 ft2 2 ft 0 in 2 It 0 in 2 ft 0 in 2 It 0 in 2 It 0 in 2 It 0 in 2 ft 0 in 2 It 0 in 2 It 0 in 2 It 0 In 2 It 0 in 1 It 0 in 1 ft 0 in 1 It 0 in 0It 0In 1 It 0 in 1 It 0 In 1 R 0 in 1 ft 0 in 1 ft 0 in 3 ft 5 in 3 If 5 in None None None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 299 ft2 299 ft2 27 It 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 1927 105.79 198.95 .1522 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 36 kBtulhr 1080 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage Volume FEF None None ft2 215/202011:57 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / —Supply— — Return Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 112 Attic 15 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable[lin[XT�]hermostatf:Jan N CAprffelllliing Fans: Venting J [FebfX]1 Mar(([ Mar 11 Apr May n JMay un [X] [ ) Jul �XI ( ] Aug Sep f[X11 Oct Dec f[X1] Deecc j ] n [ ] Feb [XJ [XJ [ ] Jun [ 1 Jul (1 Aug 111 111 Sep [XJ Nov [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 - 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM ' 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 fN 0 ft 0.3 BEDROOM 4 Default(B lbs/sq.fL ft2 In 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 It 0.3 CLST 4 Default(B lbslsq.fL ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 In 0.3 DINING Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 ibs/sq.fL ft2 ft 0.3 CLST 3 Default(8 lbs/sq.ft. ft2 It 0.3 CLST 2 Default(8 lbs/sq.fL ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 It 0.3 BATH 2 Default(8 lbs/sq.ft ft2 It 0.3 HALLWAY Default(8 lbs/sq.fL ft2 ft 0.3 LINEN 2 Default(8 lbs/sq.fL ft2 ft 0.3 MWIC Default(8 lbs/sq.ft. ft2 ft 0.3 LINEN Default(8 lbslsq.ft. ft2 It 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default 8lbs/s .ft. ft2 ft 0.3 FOYERIGREAT RO 2/5/2020 11:57 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 6 of 6