Certification for Design Load Compliance
Project Name: Lucas Residence
Project Address: 9473 Meadowood Drive
Permit #: Occupancy Type: R-3 Construction Type: V=B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
X New Residences (single or multi -family)
o Residential Addition
Any accessory structure requiring a building permit
Any non-residential structure.
" Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
,:
1. DESIGN CODE: Florida Building Code Sixth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X 11 _III_IV Exposure Category:_B X C _D
4. Design Wind Velocity 157 mph 122 ASO 157 LRFD End Zone Width: ft
5. Mean Roof Height ft Roof Pitch:6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -43 Zone 2: -70 Zone 3: -70 Zone 4: +33/-36 Zone 5: +33/44 Garage: +27/-30
7. Design Loads: Floor: PSF Roof/Dead:7 PSF Roof/Uve:20 Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9.
Is A Continuous Load Path Provided?_YesNot
Applicable Explain Why Not:
10.
Design Soil Bearing Pressure: 1800
PSF
Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
I forces specified:
Signa ure,.Dat�e, and Seal
Terence Schlitt, FL P.E.# 81238 C A :0 32-2-95-'
Print Name Cert # & Co. Cert Auth.
T.E. Schlitt Engineering
1555 Indian River Blvd Suite B-145, Vero Beach, FL 32960
Company Name & Address
Revised 12/07/2018