HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Lucas Residence Project Address: 9473 Meadowood Drive Permit #: Occupancy Type: R-3 Construction Type: V=B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: X New Residences (single or multi -family) o Residential Addition Any accessory structure requiring a building permit Any non-residential structure. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) ,: 1. DESIGN CODE: Florida Building Code Sixth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X 11 _III_IV Exposure Category:_B X C _D 4. Design Wind Velocity 157 mph 122 ASO 157 LRFD End Zone Width: ft 5. Mean Roof Height ft Roof Pitch:6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -43 Zone 2: -70 Zone 3: -70 Zone 4: +33/-36 Zone 5: +33/44 Garage: +27/-30 7. Design Loads: Floor: PSF Roof/Dead:7 PSF Roof/Uve:20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided?_YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1800 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design I forces specified: Signa ure,.Dat�e, and Seal Terence Schlitt, FL P.E.# 81238 C A :0 32-2-95-' Print Name Cert # & Co. Cert Auth. T.E. Schlitt Engineering 1555 Indian River Blvd Suite B-145, Vero Beach, FL 32960 Company Name & Address Revised 12/07/2018