Loading...
HomeMy WebLinkAboutEnergy CodeRECEIV>-b FORM R405-2017 JUL 10 2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING Q Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LUCAS Bulkier Name: Street•. Permit Office: City, Stale, Zip: ST. LUCIE COUNTY, FL, Permit Number. Owner. PAUL LUCAS Jurisdiction: Design Location: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2820.0 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Stock - Int Insul, Exterior R=5.0 2520.00 ft' b. Frame- Wood, Adjacent R-13o 300.00 ft 3. Number of units, Ifmultiple family 1 c. WA R= ft' 4. Number of Bedrooms 2 d• WA R= ft' 5. Is this a waist case? No 10. Ceiling Types (1777.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 1777.00 ft' 6. Conditioned floor area above grade (ft� 1777 b. WA R= ft' Conditioned floor area below grade (fNj 0 a, NIA R= fl' 11. Dusts R ft' 7. Windows(264.0 soft.) Deccriptwn Area a. Sup: Attic, Rat Attic, AH: Garage 6 355A a. U-Factor. Sgl, U=1.04 264.00fe SHGC: SHGC=0.25 b. U-Factor. NIA 112 12. Cooling systems kl3tufhr Efficiency SHGC: a. Central Unit 44.0 SEER:16.00 c- U-Factor. NIA ft' SHGC: 13. Heating systems kStu/hr Efficiency d. U-Factor. WA ft' a. Electric Strip Heat 31.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.727 it Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 6. Floor Types (1777.0 spit) insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1777.00 ft' b. Conservation features b. NIA R= ft' None c. N/A R-- w 15. Credits Patel Glass/Floor Area: 0.149 Total Proposed Modified Loads: 66.82 PASS Total Baseline Loads: 68.97 ai I hereby certify that the plans and specifications covered y Review of the plans and S1106' this calculation are in compliance with the Florida E r specifications covered by this OOUE �. , ; = 0 Code. calculation Indicates compliance �j� C .-•� PREPARED -BY.. (Ala :2 i _Cat _._v... with the Florida Energy Code. Before construction is completed DATE: .C-)b-,. ✓✓ this building will be inspected for compliance with Section 553.908 v a a I hereby certify that this building, a design i compliance with the Florida Energ Florida Statutes. OD WE f¢ OWNERfAGENT ....... . _.___. ___ _.____ _ BUILDING OFFICIAL: --_____ ._.._-..................... .. DATE: DATE: ---..._....._..._..._._ ............... - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Banierand Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.73 ACH50 (R402.4.1.2). 7/aI2020 9:47 AM EnergyGaugeO USA 0.0.02 (Rev. 1) - Fk Res2017 FSC Oth Edition (2017) Compliant Software page 1 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13, Coaling system: Capacity 44.0 a) Split system SEER 5, is this a worst case? (yeslnc) 5. No b) Single package SEER c) GroundMrater source SEERICOP 6. Conditioned floor area (sq. R) 6. 1777 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.040 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 31.0 c) Area 7c. 264.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factoc(weighted average) 88. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) ga. 0.0 b) Wood, ralsed (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) gc. a) Electric resistance EF O. 77 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 1OA7. a) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent g) Other 1. Wood frame (insulation R-value) 1081. 13.0 2. Masonry (Insulation R-value) 1 OB2. 16. HVAC credits claimed (Performance Method) 11. Calling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation V O b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Muttizone cooling credit d) Radiant barter installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: Date: City/FL Zip: ST. LUCIE COUNTY, FL 7IM0209:48:00 AM EnergyGaugeO USA 6.0.03 (Rev. 1)- Flaftes2017 FBC 6th Edition (2017) Compliant Software Page i of 1 , FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LUCAS Bedrooms: 2 Address Type: StreatAddress Building Type., User Conditioned Area: 1777 Lot# Omer Name: PAUL LUCAS Total Stories: 1 BloWSubdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: ST. LUCIE COUNTY, Family Types Single-family FL, New/Erdsting: New (From Plans) Comment CLIMATE ✓ Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Ske 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 efockl 1777 17770 SPACES Number Name Area Volume IOtchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ZONE 1 1777 17770 Yes 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area ..... ............:._. ........: ............. ._.......... 1 SlatsOn-Grade Edge Insulatio ZONE 1 252It 0 Im R' _ 0 0 1 ROOF J Roof Gable Roof Red Solar SA Emrt Emitt Deck Pitch # Type Materials Area Area Color Bart Absor. Tested Tested Insul. (deg) 1 Hip Metal 1987W af? Medium N 0.96 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC i Full attic Vented 150 1777fe N N CEILING # Type__ Space R-Value Ins Type Area Framing Froc Truss Type _ 1 _Ceiling Under Attic (Vented) ZONE 1 30 Blown 1777 f i 0.11 Wood V812920 9A7 AM EnergyGauge8 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHFCKI_IST RFPART WALLS Adjacent SpaceeRvalua Cavity Width Height Sheathing Framing Solar Below #-Omt Tn--Waglypa Ft-In-._..FLJn Aga a-Value_Emc ion-Absoc._.Gmde°lo_ _ 1 N Exterior Concrete Stock- Int Insul ZONE 1 5 87 10 870.0 fl` 5 0 0.75 0 -2 S Exterior Concrete Block -fit Insul ZONE 1 5 87 10 870.0 ft' 5 0 0.75 0 -3 E Exterior Concrete Stock - Int Insut ZONE 1 5 39 10 390.0 ft' 5 0 0.75 0 -4 W Exterior Concrete Block -lnt Insul ZONE 1 5 39 10 390.01P 5. 0 0.75 0 5 W Garage Frame - Wood ZONE 1 13 130 10 300.0 ft' 13 0.11 0.75 6 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft in 1 N Insulated ZONE 1 None .46 16 8 128 it' 2 N Insulated ZONE 1 None A6. 7 a 56 ft' WINDOWS Orientation shown is the entered. Proposed orientation. Wall Ovemang V # -............ ...... _......... Dint 10 Frame Panes _.-'- NFRC U-Fedor SHGC Imp Area Depth Separation Int Shade Screening _ i W 4 Metal Low-E Single Yes 1.04 0.25 Y �...._._.__ 48.0 ft' 12 It 0 in 1 ft 0 in Drapes/blinds None _ 2 W 4 Metal Low-E Single Yes 1.04 025 Y 48.0 IF 12 ft 0 in / It 0 in Dropeslblinds None _ 3 S 2 Metal Low-E Single Yes 1.04 025 Y 24,.0 ft' 12 it 0In 1 ft 0 in Drapesiblinds None 4 S 2 Metal Low-E Single Yes 1.04 0.25 Y 12.0 ft' 2 ft 0 In 1 ft 0 in Drapes/blinds None 5 E 3 Metal Low-E Single Yes 1.04 025 Y 40.0 ft' 2 It 0 in 1 ft 0 in Drapeslbiinds None _ 6 E 3 Metal Low-E Single Yes 1.04 0.25 Y 4.0 8' 2 It 0 in 1 ft 0 in Drapes/blinds None _ 7 N 1 Metal Low-E Single Yes 1.04 0.25 Y 10.0 ft' 2 ft 0 in 1 It 0 in Drapeslblinds None _ 8 E 3 Metal Low-E Single Yes 1.04 025 Y 24.0 fe 4 It 0 in 1 ft O In Drapeslblinds None 9 N 1 Metal Low-E Single Yes 1.04 0.25 Y 24.0 ft' 2 It 0 in 1 ft 0 in Drapesiblinds None 10 W 4 Metal Low-E Single Yes 1.04 0.25 Y 30.0 ft' 2 ft 0In 1 It 0 In Drapesiblinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 630.3 ft' 630.3 ft' 84 ft loft 5 INFILTRATION # Scope --...------'----_- Method SLA CFM 50 ELA EgLA ACH ACH 50 ..............._------ .._...------ 1 Wholehouse Proposed CFM(50) .0003 `__- ------ ------ - 1400 78:86 144.64 .1138 --'---.----_.----- 4.7271 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts f Electric Strip Heat( None COPA 31 kStwnr 1 sys41 71812020 9:47 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017FBC 61h Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Airflow SHR Block Ducts _ 1 Central Unit/ None SEER: 16 44 kBlulhr 1320 cfm 0.75 1 ~sys#1 HOT WATER;SYSTEM System Type SubType Location EF Cap use SetPnt Conservations i Electric' _ None Garage 0.97 50 gat 50 gal _ 120 deg J None _ SOLAR HOT WATER SYSTEM FSEC Collector Storage Can # Company Name _--� System Model # Collector Model # Area Volume FEF None None — DUCTS / — Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT CIN RLF Heat Cool 1 Attic 6 355A ft Aft 88.85 ft Default Leakage Garage .(Default) (Default) 1 1 TEMPERATURES ProgramablCoolingt(e Thermostat Y Ceiling Fans: Heating FebJan Feb Mar ((( Apr n Jun f[X M Jun Jul (tX�t Aug Oct I[X,l Nov NovNo Dec rX�} Dec ng [ ] Jan [ J y [ [ J Sep [XJ [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)-- AM 78 78 78 78 78 78 78 78 80 80 8o 8o PM 80 80 80 8o 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 8o 80 80 PM 80 8o 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 Be 68 68 68 68 Heating (WEH) 68 68' 68 68 68 68 PPMM 68 68 68 68 68 68 MASS _ Mass Type Area Thickness Furniture Fraction Space Default(B lbs/sq.fL 0 ft' Off 0.3 ZONE 1 71812020 9:47 AM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4