Loading...
HomeMy WebLinkAboutIn-Place Density Report_Test-8.24.20 � Iu Ardaman In-Place Density Report Client: Project: ME& &Associates, Inc. Permit#2007-0290 Renar Development Corp. 113-15-66-5434B Report Date: 8/21/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 Test Results Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp. Test# Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (in) Compaction (%) Remark 340 8/14/20 20-238 A 11.0 116.0 8.9 111.1 12 96 95 Pass (Modified) 341 8/14/20 20-238 A 11.0 116.0 10.2 110.0 12 95 95 Pass (Modified) 342 8/14/20 20-238 A 11.0 116.0 9.3 111.5 12 96 95 Pass (Modified) 343 8/14/20 20-238 A 11.0 116.0 11.0 112.6 12 97 95 Pass (Modified) 344 8/14/20 20-238 A 11.0 116.0 9.8 109.9 12 95 95 Pass (Modified) 345 T-7720 20-238 A 11.0 116.0 9.2 110.7 12 95 95 Pass (Modified) Test Information Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 340 Footings: Footings for Lot 28 at 9725 Starboard Drive. NW End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech, Port St. Lucie 341 Footings: Footings for Lot 28 at 9725 Starboard Drive.SW End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech, Port St. Lucie 342 Footings: Footings for Lot 28 at 9725 Starboard Drive.SE End of Footings -1.0 Bottom of footings CPN/MC-3/M340507396/ Tech, Port St. Lucie 343 Other: House Pad for Lot 28 at 9725 Starboard Drive.SE End of Pad -1.0 1 Top of pad CPN/MC-3/M340507396/ Tech, Port St. Lucie 344 Other: House Pad for Lot 28 at 9725 Starboard Drive.SW End of Pad -1.0 Top of pad CPN/MC-3/M340507396/ Tech, Port St. Lucie 345 Other: House Pad for Lot 28 at 9725 Starboard Drive. NE End of Pad -1.0 Top of pad CPN/MC-3/M340507396/ Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. � Iu Ardaman In-Place Density Report Client: Project: ME& &Associates, Inc. Permit#2007-0290 Renar Development Corp. 113-15-66-5434B Report Date: 8/21/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 ♦ No.63911 U ; gyp , , � . i /// ONAL /I I I I This item has been digitally signed and sealed by Branch Manager Dan J.Zrallack, P.E. on Aug 21, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.