HomeMy WebLinkAboutIn-Place Density Report_Test-0336-0339_6687240 � Iu Ardaman In-Place Density Report Client: Project:
ME& &Associates, Inc. Permit#1911-0396 Renar Development Corp. 113-15-66-5434B
Report Date: 8/14/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce
Florida CA No.5950 Fort Pierce, FL
460 NW Concourse Place,Unit 1
Port St.Lucie,FL 34986
Phone:772-878-0072
Test Results
Optimum Maximum In Place In Place Probe
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp.
Test# Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (in) Compaction (%) Remark
336 8/10/20 20-073 A 10.0 112.0 9.3 110.3 12 98 95 Pass
(Modfied)
337 8/10/20 20-073 A 10.0 112.0 8.7 109.9 12 98 95 Pass
(Modfied)
338 8/10/20 20-073 A 10.0 112.0 10.3 111.1 12 99 95 Pass
(Modfied)
339 8/10/20 20-073 A 10.0 112.0 10.9 110.7 12 99 95 Pass
(Modfied)
Test Information
Gauge
Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician
336 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -1.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie
91.Center of Pad,South Side
337 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -1.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie
91.Center of Pad, North Side
338 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -2.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie
91.Center of Footing,West Side
339 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -2.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie
91.Center of Footing, East Side
Remarks Comments
Pass: Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as
"Backscatter".Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
� Iu Ardaman In-Place Density Report Client: Project:
ME& &Associates, Inc. Permit#1911-0396 Renar Development Corp. 113-15-66-5434B
Report Date: 8/14/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce
Florida CA No.5950 Fort Pierce, FL
460 NW Concourse Place,Unit 1
Port St.Lucie,FL 34986
Phone:772-878-0072
♦
No.63911
U ;
gyp , , � .
i
/// ONAL
/I I I I
This item has been digitally signed and sealed by Branch
Manager Dan J.Zrallack, P.E. on Aug 14, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.