Loading...
HomeMy WebLinkAboutIn-Place Density Report_Test-0336-0339_6687240 � Iu Ardaman In-Place Density Report Client: Project: ME& &Associates, Inc. Permit#1911-0396 Renar Development Corp. 113-15-66-5434B Report Date: 8/14/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 Test Results Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp. Test# Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (in) Compaction (%) Remark 336 8/10/20 20-073 A 10.0 112.0 9.3 110.3 12 98 95 Pass (Modfied) 337 8/10/20 20-073 A 10.0 112.0 8.7 109.9 12 98 95 Pass (Modfied) 338 8/10/20 20-073 A 10.0 112.0 10.3 111.1 12 99 95 Pass (Modfied) 339 8/10/20 20-073 A 10.0 112.0 10.9 110.7 12 99 95 Pass (Modfied) Test Information Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 336 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -1.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie 91.Center of Pad,South Side 337 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -1.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie 91.Center of Pad, North Side 338 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -2.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie 91.Center of Footing,West Side 339 Building-Slab on Grade: House Pad and Footings at 9783 Palm Breezes Drive,Lot -2.0 Top of Pad CPN/MC-3/M330907150/ Tech, Port St. Lucie 91.Center of Footing, East Side Remarks Comments Pass: Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. � Iu Ardaman In-Place Density Report Client: Project: ME& &Associates, Inc. Permit#1911-0396 Renar Development Corp. 113-15-66-5434B Report Date: 8/14/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 ♦ No.63911 U ; gyp , , � . i /// ONAL /I I I I This item has been digitally signed and sealed by Branch Manager Dan J.Zrallack, P.E. on Aug 14, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.