Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WS-LOT-9 MANUAL-J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-13 13:33:47 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-9.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Aug 11, 2020Date:Entire House By: Project Information WATERSTONE LOT-9For: ARMINA PL (LOT 9 BLOCK 3), FT. PIERCE, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5050Inside humidity (%) 5922Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140361A*Cond GSZ140361A* AHRI ref 4514392 Coil AR*F374316C* AHRI ref 4514392 Efficiency 8.7 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh24500 Heating output Btu h @ 47°F33400 Latent cooling Btuh10500 Temperature rise °F26 Total cooling Btuh35000 Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.055 Air flow factor cfm/Btuh0.046 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.68 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) OWNERS SUITE 210 3204 3216 175 147 DINING AREA 185 1852 1342 101 62 GREAT ROOM 207 3685 5461 201 250 EX STE BED 137 1096 1379 60 63 KITCHEN 181 183 1800 10 82 OS BATH 95 877 459 48 21 OS WIC 64 586 308 32 14 FOYER 92 2226 1919 122 88 HALL BATH 53 54 107 3 5 BEDROOM 3 147 1855 1707 101 78 LAUNDRY 78 255 851 14 39 BEDROOM 2 138 1471 1489 80 68 HALL 54 55 110 3 5 EX STE BATH 51 52 104 3 5 EX STE LNDY/FOYER 35 607 1501 33 69 EX STE WIC 20 133 280 7 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-13 13:33:47 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 2 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-9.rup Calc = MJ8 Front Door faces: W EX STE LIVING 166 3171 3425 173 157 Entire House 1914 21362 25457 1167 1167 Other equip loads 0 0 Equip. @ 0.95 RSM 24312 Latent cooling 12176 TOTALS 1914 21362 36487 1167 1167 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-13 13:33:47 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-9.rup Calc = MJ8 Front Door faces: W Job:Project Summary Aug 11, 2020Date:Entire House By: Project Information WATERSTONE LOT-9For: ARMINA PL (LOT 9 BLOCK 3), FT. PIERCE, FL 34951 Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16 Daily range L Relative humidity %50 Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18107 Structure Btuh19847 Ducts Btuh3255 Ducts Btuh5610 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh21362 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh24312 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh10649 Ducts Btuh1527 CoolingHeating Central vent (0 cfm)Btuh0 19141914Area (ft²)Equipment latent load Btuh12176 1664716647Volume (ft³) Air changes/hour 0.140.26 Equipment total load Btuh36487 Equiv. AVF (cfm)3972 Req. total capacity at 0.70 SHR ton2.9 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140361A*Cond GSZ140361A* AHRI ref 4514392 Coil AR*F374316C* AHRI ref 4514392 Efficiency 8.7 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh24500 Heating output Btu h @ 47°F33400 Latent cooling Btuh10500 Temperature rise °F26 Total cooling Btuh35000 Actual air flow cfm1167 Actual air flow cfm1167 Air flow factor cfm/Btuh0.055 Air flow factor cfm/Btuh0.046 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.68