Loading...
HomeMy WebLinkAboutCompaction testHeadquarters 11345 U.S. Highway 1 Tllll C� 1 Mailing PO Box78-1377 Sebastian, FL. 32958 AtENGINEERING Z%&J jW AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-58589-0712-0712 723 Progress Way C.A.# 5693 Sanford, FL. 32771 SOIL COMPACTION REPORT KSMengineering.net ASTM D 1557 and ASTM D 2922 DATE TESTED: January 31, 2020 KSM JOB #: 200500-id/MH/cv PERMIT #: 1911-0556 CONTRACTOR: Wynne Development Corp. JOB LOCATION: 6556 Spanish Lakes Boulevard Spanish Lakes Fairways Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. N.E. 0" - 12" 50 110.6 113.4 97.5% 2. S.E. 50 111.4 98.2% 3. Center 50 110.9 97.8% 4. N.W. 50 112.6 99.3% 5. S.W. 50 109.9 96.9% 114.0 - W I Soil Description: E Brown Sand with Traces of Clay G H 1130 —•I. .._L._.. 1 In Place Moisture: T T- 7.9% Optimum Moisture: P112.0 �— I I I I I —' — —•• 11.0% C I 1 I ( 1 T Max. Dry Density: P.C.F. F I I I I I I I I I 113.4 111.0 T- @ Test Locations The D I I I I I I Density & Penetrometer R I I I I I Readings Indicate the y I I I I I 1 Degree of Compaction Meets 110.0 — .4------; Minimumquvg� 8 9 10 11 12 13 14 for &ike , Moisture - % of Dry Weight ``gyp' o. 39 _ Disclaimer: Contractor is responsible to maintain E OF ;• the tested area in the condition that KSM • B� ISlta�����; completed the indicated passed compaction test. KSM is not responsible if the tested area has been PE # 81439 2 3 2020 altered from the / / approved inspected condition. Email to: dotty@wynnebc.com; St. Lucie County Building Department Proudly Serving Florida since 1990