HomeMy WebLinkAboutNOA; Therm-O-Flex TF 1000 Series Elastromeric Roof CoatingMIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Slreet Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525.99
NOTICE OF ACCEPTANCE (NOA) v vw.miamidade.eov/econumv
LAPOLLA Industries, Inc.
15402 Vantage Parkway East, Suite 322
Houston, TX 77032
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
Tllis NOA shall not be valid after the expiration date stated below. The Miami -Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Therm-O-Flex TF 1000 Series Elastomeric Roof Coating.
.LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0726.04 and consists of pages 1 through 3.
The submitted documentation was reviewed by Jorge L. Acebo.
File COPY
NOA No.: 16-0525.09
Expiration Date: 08/09/21
Approval Date: 07/21/16
Page 1 of 3
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Cak orv: Cement -Adhesive -Coatings
Materials: Elastomeric
SCOPE:
This approves "Therm-0-Flex TF 1000 Series Elastomeric Roof Coating" as a maintenance roof
coating as manufactured by LAPOLLA Coatings, as described in this Notice of Acceptance, designed to
comply with the Florida Building Code, High Velocity Hurricanes Zone.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reoort Dig
Underwriter Laboratories, Inc. R14353 UL 790 12/15/11
Factory Mutual Research Corp. 3023796 Class 4470 10/02/05
PRI Construction Materials LPII- 013-02-01 ASTM D 6083 01/10/12
Technologies, LLC TT-C-555B
MANUFACTURING LOCATION:
1. Houston, TX.
PHYSICAL PROPERTIES OF COMPONENTS
Trade names: Therm-O-Flex TF-1001(White), TF-1002(Grey), TF-1003(Tan)
Thickness: Wet Film per Coat: 24 mils
Dry Film per Coat: 13.2 mils
Specifications: ASTM D 6083
Description: A water -based eastomeric coating membrane applied at an application rate of;
• Galvanized Metal Roofs: Apply Base Coat at a rate of 1.5 to 2 gal/100 fl
and Finish Coat at a rate of 1.5 to 2 gal/100 ft2.
• SBS Modified Bitumen Granule Surfaced Membranes: Apply Base Coat at a
rate of 1.5 to 2 gal/100 ft' and Finish Coat at a rate of 1.5 to 2 gal/100 ft.
• EPDM Single Ply Membranes: Apply Base Coat at a rate of 1.5 to 2 gal/l00
R2 and Finish Coat at a rate of 1.5 to 2 gal/l00 ft
• Spray Polyurethane Foam Roof Systems: Apply Base Coat at a rate of 1.5 to
2 galJ100 ft' and Finish Coat at a rate of 1.5 to 2 gal/100 ft.
• Concrete Decks: Apply Base Coat at a rate of 1.5 to 2 gal/100 W and Finish
Coat at a rate of 1.5 to 2 gal/] 00 ft2.
Container Size: 5, 55 and 275 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities sliall comply with specific Roof
Assembly, Product Control Notice of Acceptance.
NOA No.: 16-0525.09
MIAMMADE COUNTY Expiration Date: 08/09/21
Approval Date: 07/21/16
Page 2 of 3
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance
2. Any other documents required by the building official or the Applicable Building Code in order to
properly evaluate the installation of this system.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. Therm-O-Flex TF 1000 Series Elastomeric Roof Coating shall not be applied in inclement weather
conditions.
3. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list any of the products listed herein as part of their roof assemblies Notice of
Acceptance.
4. All products listed herein shall have an unannounced follow-up quality control program from an
approved listing agency. Follow up test results shall be made available to Miami -Dade Product
Control upon request.
5. Change in materials, use, or manufacture of any of the products listed herein shall be cause for
termination of this Notice of Acceptance.
6. Therm-0-Flex TF 1000 Series Elastomeric Roof Coating shall be used as a roof maintenance
coating system in accordance with applicable Building Code. Therm-0-Flex TF 1000 Series
Elastomeric Roof Coating is not approved for use as a recover system.
7. Therm-0-Flex TF 1000 Series Elastomeric Roof Coating shall be applied in accordance with
manufacturer's published application instructions.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61 G20-3 of the Florida Administrative Code.
9. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the
imprint or identifiable marldng of the manufacturer's name or logo, city, state and the following
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below
END OF THIS ACCEPTANCE
NOA No.: 16-0525.09
Expiration Date: 08/09/21
Approval Date: 07/21/16
Page 3 of 3