HomeMy WebLinkAboutR2C 2926 S Header Canal Rd BNDY TOPO-SHEET1 8.25.2045.3' 1 1
Q
o1
I
�
w
Z
J
Q }
Z 39:
a
�I
Q10
U
O
2
6 g
w 2
Q �
W
1m
I
I
uj
z
w
1
I
w
'a
�
I
J
Q
�
V)
a
I
I
I
o
LOT 3
(VACANT)
FOUND 5/8" IRON ROD & CAP FOUND 5/8" IRON ROD & CAP
e� STAMPED "AJP PSM 6330" STAMPED "AJP PSM 6330"
0.28' NORTH 0.92 NORTH
�0 0.55' WEST 0.53' WEST 06�
S89°25'51 "E 660.00' x,
715' D.E. U.E.
.
0
lc h SET 5/8" IRON ROD & CAP
II I 1-------------------------------------PER PLAT
I - - - - - - - - - - - - - - - - - -
STAMPED "LB 7805"
45.3'1. 72.5'
II I w 1
1
Q LOT 2 - 1
w
(VACANT) 1
I J w
Q I o- 1 _--- - - - - - o
� w w
C_) I N I w 1 > Y
z
--- �� z
1ryxL o'DQ / , �� \x 12 (3) 0_C3 U
LLJ �� eo Y z�� 1 / I I �o F w
I 0-) } I Io S oaw 1 / / \ \ o O
/ 8 " 56.7' w v7
J J mo: I / // �\ \_ // // w a� rN LOT 6
Q Q _� / ' 1 N -0 zq - N +�° PROPOSED COVERED PATIO 1 a (VACANT)
Q Q ---------� ----� I 12" I /� PROPOSED /a0' ��N �7. 2 1 w� W
_ � I I I I COVERED � 17
NCi
U - - - - - - - - - PROPOSED DIRT DRIVEWAY PROPOSED POND I / PORCH ww W lz 8.7 PROPOSED CONC. POOL & DECK Lo � N
r--------- I I / �
II o I 1 �\ I 1' 12 M 0Nw M M o
006 W 1 jI Z I 1 \ 1 / / / 10" M ZD
�vo M\ (n
z Q 1 \ / / �+ 5.0' a
13.0' n 28.0 15.7' 198.3'
h o w / + 21.0' ti
/ / 14" Iti° PROPOSED WATER LINE x yo
/x / I 12" 12"
14"
I i
1 0 1 m I \ \ \ \ \ _ _ i / i i / PROPOSED WELL 75. RAD/�S
I 1 O 1 I`` A 1
t o IIo
I I I 12"
I I I
1 1 o"
I
I
x1p 18"
I
o FOUND 5/8" IRON ROD & CAP
titi°� a�tFOLIND 5/8" IRON ROD & CAP N89*32'29"W 660.00' S"oMPED "AJP PSM 6330"
TAMPED "AJP PSM 6330" ti
I
ZI
I r 00
�
C; LOT 1
o w
w (VACANT) HEADER RANCHES SUBDIVISION
3Q PLAT BOOK 40, PAGES 38
_ m
(� N o
I of 1n z
O -
N ZW
wl m
I
SOUTHWEST CORNER LOT 1
FOUND 5/8" IRON ROD & CAP
STAMPED "AJP PSM 6330" - - - -
Y
Z
Q
m
w
O
CL
0
140'
NATURAL GRADE
TOP OF WATER
1 3 11' ZY
3
CROSS SECTION A -A
PROPOSED POND
NOT TO SCALE
`1
z
Q
m
O
0_
0
EL 20.3
LV%. t-N 1 I%JIN IVIP1r
(NOT TO SCALE)
LEGEND
O.R.B. -
OFFICIAL RECORDS BOOK
(�-
CENTERLINE
PLAT
M-
�P�-
MEASURED
D-
DEED
(C)-
CALCULATED
L.B. -
LICENSED BUSINESS
CONC.-
CONCRETE
C.M.P.-
CORRUGATED METAL PIPE
INV -
INVERT
EL -
ELEVATION
F.F.E. -
FINISH FLOOR ELEVATION
U.E.-
UTILITY EASEMENT
D.E.-
DRAINAGE EASEMENT
OHU -
OVERHEAD UTILITY LINE
c0b-
WOOD POWER POLE
�-
GUY ANCHOR
C.C.R.-
CERTIFIED CORNER RECORD
# -
WOOD LIGHT POLE
®-
ELECTRIC METER
I.D. -
IDENTIFICATION
QT -
TELEPHONE RISER
M.E.S.-
MITERED END SECTION
{ -
CAN RISER
-
OAK TREE
-
PALM TREE
GRAPHIC SCALE
0 40 80
( IN FEET )
1 inch = 40' ft.
DESCRIPTION
LOT 2, HEADER RANCHES SUBDIVISION, ACCORDING TO THE PLAT THEREOF, RECORDED IN
PLAT BOOK 40, PAGE 38, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
SURVEYOR'S NOTES
1. THIS SURVEY MAP OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE
AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER.
2. HORIZONTAL RELATIONSHIPS, AS SHOWN HEREON, ARE BASED ON THE FLORIDA STATE
PLANE COORDINATE GRID, EAST ZONE, USING THE NORTH AMERICAN DATUM OF 1983 WITH
THE 2011 ADJUSTMENT (NSRS 2011).
3. THE EAST RIGHT OF WAY LINE OF NORTH ST. LUCIE RIVER WATER MANAGEMENT DISTRICT
CANAL NO. 59 IS ASSUMED TO BEAR NORTH 00°05'24" WEST AND ALL OTHER BEARINGS
SHOWN HEREON ARE RELATIVE THERETO.
4. THE HORIZONTAL LOCATION OF NON -DIMENSIONED FEATURES ARE PLOTTED TO SCALE,
UNLESS NOTED OTHERWISE.
5. SYMBOLS SHOWN WITHIN THIS DRAWING ARE NOT SCALE DEPENDENT.
6. DESCRIPTION SHOWN HEREON PROVIDED BY CLIENT.
7. FIELD SURVEY LAST CONDUCTED ON JUNE 1, 2020.
8. OVERALL PARCEL CONTAINS 5.00 ACRES, MORE OR LESS.
8. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING
PARTY OR PARTIES ARE PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR
PARTIES.
9. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS -OF -WAY, EASEMENTS,
OWNERSHIP, OR OTHER INSTRUMENTS OF RECORD.
10. UNDERGROUND IMPROVEMENTS, IF ANY, WERE NOT LOCATED, EXCEPT AS SHOWN.
11. ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM
OF 1988 (NAVD 88).
12. LIMITS OF WETLANDS, IF ANY, UNDER GOVERNMENT JURISDICTION, WERE NOT
DETERMINED AS PART OF THIS SURVEY.
13. BY GRAPHIC PLOTTING ONLY, SAID DESCRIBED PROPERTY IS LOCATED WITHIN AN AREA
HAVING A FLOOD ZONE DESIGNATION OF "X" AND "A", ACCORDING TO THE FEDERAL
EMERGENCY MANAGEMENT AGENCY (FEMA) ON FLOOD INSURANCE RATE MAP (FIRM) PANEL
NUMBER 121 1 1 CO150J AND 121 1 1 C01 65J, HAVING AN EFFECTIVE DATE OF FEBRUARY 16,
2012. THIS INFORMATION SHOULD BE CONFIRMED WITH THE APPROPRIATE COUNTY PRIOR
TO CONSTRUCTION.
14. SIZE OF TREES, AS SHOWN HEREON, WERE MEASURED AT BREAST HEIGHT OF TRUNK.
CERTIFIED TO
DIEDERICH HUECK
SURVEYOR'S CERTIFICATE
I HEREBY CERTIFY THAT THE BOUNDARY SURVEY, AS SHOWN HEREON, IS A TRUE AND
CORRECT REPRESENTATION OF A FIELD SURVEY MADE UNDER MY DIRECTION AND CHARGE AND
SAID SURVEY IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE AND BELIEF. I
FURTHER CERTIFY THAT SAID SURVEY COMPLIES WITH THE APPLICABLE STANDARDS OF
PRACTICE FOR SURVEYS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS
AND MAPPERS IN CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION
472.027, FLORIDA STATUTES.
CIVILSUI�V DESIGN GROUP, INC.
O
i=
W
�
w
U
�
O
O
cl�
CL
QD
0
Co
o
�
I=
w
z
Cl::
o
m
w
-
z
O
C)
C
w
�
o
>
w
o
o
Q
w
w
m
�
�z
�
C
w
w
w
Q
w
�
0
w
0
o
0
o
�
>
o
0
o
0
C
C
0
0
0
0
0
N
N
C" M
N
C7
N
ti
ti
a>
H
Z Lo
��
/rt0/rt ai
V i
a>
�Z a
C/) U-
w
Cn r >> u
y
U 'o
0
00
N
"
Y
m
}
m
O
m
m
Z
Y
c�
w
w
Oct
m
=
o
LL
m
U
N
C
0
z
m
CO)
II
o
�
O
T
Q
z
U o
O
z
�CIO
o
w
ui
w
=m
a
cai
0
N z
0
Cl)
d
N m
w
M
a
a
0 =
Q �
OW
Lf) 0
� J C")OC
a_
>Z=-1
Q z LL
Oz
W O
0 Q N V
Z Q z w
5 W O ()
0 = V J
(A Cj) F-
N O
0) z
N O
cc
O
a
a
z
0
z
J
BY: BRIAN C. KIERNAN
PROFESSIONAL SURVEYOR & MAPPER
FLORIDA REGISTRATION NO. 6101
DATE OF SIGNATURE
SHEET NO.
I
OF
I