Loading...
HomeMy WebLinkAboutLetter from David Cleveland, response to comments■■ Cleveland Design Group,lnc. 772-464-2010 vidandl2Qyahoo.com 100 Avenue A, Suite 2E Fort Pierce Florida 34950 AUGUST 17, 2020 TO: WILLIAM DURDEN RE: PERMIT# 2007-0648 PLAN REVIEW COMMENTS DATED 8/3/2020 MR. DURDEN, THE FOLLOWING ARE RESPONSES TO YOU COMMENTS. 1- 5 WE WILL APPLY FOR SEPARATE PERMITS. 6. UNDERSTOOD 7. THE DESIGN CRITERIA IS ON SHEET 3 OF 4. 8. THE SHED THAT IS ATTACHED TO THE WEST END OF THE EXISTING GARAGE IS CONSTRUCTED AS SHOWN ON THE DRAWINGS. THE BLOCK WALL DOES NOT EXIST ANY LONGER. THE FOUNDATION TYPE IS IN COMPLIANCE WITH R403.1. 9. THE CLADDING DETAIL IS ON SHEET 2 OF 4. SECTION 107 OF THE FBC RESIDENTIAL IS RESERVED. 10. NON -HABITABLE SPACE 1 1. NON -HABITABLE SPACE 12. NON -HABITABLE SPACE 13. NON -HABITABLE SPACE 14. TO MY UNDERSTANDING THIS WAS AN ORIGINAL OPENING IN THE EXISTING BLOCK WALL. 15. THIS IS A 2' WIDE PRESSURE TREATED WALKWAY ON GRADE. 16. NON -HABITABLE SPACE 17. IN ACCORD WITH R301.1.3 THIS IS AN ENGINEERED CERTIFIED ALTERNATE DESIGN. 18. SECTION 107 OF THE FBC RESIDENTIAL IS RESERVED, THE SCREW ANCHORS HAVE BY CERTIFIED BY THE STRUCTURAL ENGINEER. 19. UNDERSTOOD 20. MOST ALL OF THE COST HAS BEEN INCURRED, THE LABOR IS BEING SUPPLIED BY THE OWNER BUILDER. ZONING REVIEW 21. UNDERSTOOD 22. THE HEALTH DEPARTMENT IS CURRENTLY REVIEWING THE PLAN REVIEW APPLICATION. 23. THE SURVEY IS BEING AMENDED TO REFLECT THE PARCEL COMBINATION. THE ELEVATIONS ARE NOT NEEDED BECAUSE THE SPACE IN QUESTION IS NON- HABITABLE AREA. WHEN THE COUNTY IS CALLED FOR INSPECTIONS 1 WILL MAKE MYSELF AVAILABLE TO MEET THE INSPECTOR ON SITE, AND WE CAN ADDRESS ANY UNFORESEEN ISSUES IN THE FIELD. REGARDS DAVID M. CLEVE ND ,Ie-7/H~ 4��o� i--.. .' - - - Ptsrwift 3 Development services 8a k*V & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. U982 REVIEW COMMENTS Comment: PHOTOS DATED 02/18/2010 SHOW SMALL ROOF STRUCTURE OVER A SLAB ON (3HADL WI I H UMU WALL BEING CONSTRUCTED, AND PHOTOS DATED 08/06/2019 SHOWS AN ELEVATED FLOOR. PER THE PHOTOS DATED 08/03/2020 THE STRUCTURE APPEARS TO BE CONSTRUCTED ON A WOOD SUB FLOOR SYSTEM; S 8/3/2020 THE PLANS SHOW THE STRUCTURE ON A 4 INCH CONCRETE SLAB ANCHORED WITH A 48 INCH X 6 INCH EARTH ANCHOR. PLEASE SHOW OR CLARIFY THE FOUNDATION SYSTEM USED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: NO PRODUCT APPROVAL SUBMITTED FOR THE COMPONENTS AND CLADDING FOR THE ADDITION. SEE 9 8/3/2020 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: NO SHOP DRAWINGS SUBMITTED FOR THE SECURITY BARS COMPLYING WITH EMERGENCY ESCAPE 10 8/3/2020 AND RESCUE. SEE R310 OF THE RESIDENTIAL BUILDING CODE. Comment: • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 t( 8/4/2020 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER Comment: • PLEASE FURNISH A DUCT PLAN SHOWING A BALANCED SYSTEM, DUCT SIZE, GRILL SIZE, AND ROOM BY 12 8/4/2020 ROOM CFMS PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN ( 8/4/2020 .3 ACCORDANCE WITH 602.2 OF THE 2017 FLORIDA BUILDING CODE Comment: NO DETAIL ON THE PLANS FOR THE ALTERATION OF THE ORIGINAL EXTERIOR WALL FOR OPENING. SEE 1-4 8/4/2020 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 15 Comment: NO DETAIL ON THE PLANS FOR THE WOOD DECK AROUND THE ADDITION. SEE SECTION 107 OF THE 2017 8/4/2020 FLORIDA BUILDING CODE. 1110 Comment: NO DETAILS ON THE PLANS FOR THE CONVERSION OF THE GARAGE TO HABITABLE SPACE. SEE 8/4/2020 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: NO FOOTING DETAILS ON THE PLANS MEETING THE MINIMUM SIZE, RESISTANCE TO UPLIFT, rt 8/4/2020 FOUNDATION ANCHORAGE REQUIREMENTS OF CHAPTER 4, SECTION 403 OF THE 2017 FLORIDA BUILDING CODE. Comment: PLEASE SHOW THAT THE CALCULATIONS FOR THE SCREW TYPE ANCHORING OF THE ADDITION. SEE ($ 8/4/2020 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. (4 Comment: UNABLE TO COMPLETE MY REVIEW OF THE ADDITION/RENOVATION DUE TO LACK OF INFORMATION ON 8/4/2020 THE PLANS. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • COST OF CONSTRUCTION SEEMS LOW PLEASE SUBMIT A DETAILED ESTIMATE FOR THE COST OF CONSTRUCTION. PERMIT VALUATIONS SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS 20 8/4/2020 AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED. AS PER SECTION 109.3 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION. ZONING REVIEW INCOMPLETE Lydia Galbraith 8W020 21 Comment: EACH INDIVIDUAL BUILDING AND THE ADDITION/GARAGE ENCLOSURE REQUIRES A SEPARATE PERMIT APPLICATION. THE CURRENT APPLICATION WILL BE USED FOR THE HOUSE ADDITION/GARAGE ENCLOSURE. PLEASE INDICATE AT EACH APPLICATION THE SIZE OF THE BUILDING TO BE CLEAR WHICH APPLICATION 8/3/2020 BELONGS TO WHICH STRUCTURE.. GAZEBO + DIMENSION 1 STORY WOOD FRAME BUILDING + DIMENSIONS SHED 13.8'X10.2' SHED 11.7'X12.3' THIS SHED WILL NEED TO BE RELOCATED TO MEET 5' REAR SETBACK., DEMOLITION PERMIT FOR ALUMINUM SHED TO BE REMOVED. 2 Z Comment: ACCORDING TO THE APPLICATION THE PROPERTY IS ON SEPTIC. 8/3/2020 PLEASE PROVIDE A LETTER OF APPROVAL FROM THE HEALTH DEP. FOR THE PROPOSED ADDITION (ENCLOSURE OF GARAGE TO EXERCISE ROOM AND THE ADDITION OF THE CRAFTSROOM. AND A COPY OF THE SURVEY WITH APPROVAL STAMP FROM HEALTH DEP. 2 5 Comment: THE SURVEY IS INCOMPLETE OR HAS CONFLICTING INFORMATION. PLEASE UPDATE WITH FOLLOWING INFORMATION: INDICATE PROPERTY AS ONE LOT. - INDICATE THE FLOOR ELEVATION OF THE HOUSE, THE GARAGE AND THE CRAFT ROOM. WE WILL NEED 8/3/2020 TO KNOW FROM EACH AREA WHAT THE FLOOR ELEVATION IS. ELEVATION OF THE CENTER LINE OF THE ADJACENT ROAD. INDICATE THE RELOCATED SHED AND GAZEBO AT THE PROPOSED LOCATION. DIMENSIONS AND SETBACKS FROM ALL PROPOSED BUILDINGS. THE SHED 117'X12.3' WILL NEED TO BE RELOCATED TO MEET V REAR SETBACK. Planning & Deveiopment Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce. FL. 34982 PROPERTY INFORMATION Address: 3307 Avenue J City / State / Zip: Fort Pierce, FI 34947 Parcel #: 2405-701-0103-000/3 Zoning: RS-4 APPLICATION INFORMATION Permit Number: 2007-0648 Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS Review Type Status DOCUMENTS MISSING PENDING Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: NOTIFIED FOR PICK UP Comment: PLANS EXAMINER REVIEW 1 8/3/2020 Comment: 2 8/3/2020 Comment: 3 8/3/2020 Comment: 8/3/2020 Comment: 8/3/2020 Comment: (0 8/3/2020 Comment: 8/3/2020 Comment: PENDING COMPLETE PENDING REVIEW COMMENTS Page 1 Owner(s): Deseriee Wiley / Robert J Wiley Jurisdiction: SAINT LUCIE COUNTY Lot#: 4 Block: 43 Stories: Automatic Sprinkler System? No Fax Number: Reviewed By Date Started Ellen Vaughn 7/30/2020 Email: Date Completed Date Released 7/30/2020 7/30/2020 INCOMPLETE William Durden 8/3/2020 A SEPARATE PERMIT IS REQUIRED FOR THE RELOCATION OF THE GAZEBO. A SEPARATE PERMIT IS REQUIRED FOR THE RELOCATION OF THE 13.30 X 24.27 SHED. A DEMO PERMIT IS REQUIRED FOR THE DEMOLITION OF THE SHED ON LOT 6. A SEPARATE PERMIT IS REQUIRED FOR THE 10.2 X 13.8 SHED WITH WOOD DECK. A SEPARATE PERMIT IS REQUIRED FOR THE 11.7 X 12.3 SHED WITH WOOD DECK. UNABLE TO COMPLETE MY REVIEW ON THE ITEMS LISTED ABOVE. ADDITIONAL INFORMATION MAY BE REQUIRED FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. THE DESIGN INFORMATION WAS NOT ON THE PLANS, PLEASE SUBMIT THE DESIGN LOAD COMPLIANCE FORM OR ADD TO THE PLANS.