Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Report (Russell) - Master Craft Aluminum Products
Property Information Owner:Russell Address:1405 Platts Ln Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 52 49 7 31.3 -34.0 2 Int 105 49 7 29.8 -32.5 3 Int 52 49 7 31.3 -34.0 4 Int 52 49 7 31.3 -34.0 5 Int 52 49 7 31.3 -34.0 6 Int 36 26 7 32.5 -35.2 7 Int 70 80 7 29.6 -32.4 8 Int 144 38 7 29.2 -31.9 9 Int 142 80 7 28.1 -30.9 10 Int 70 80 7 29.6 -32.4 11 Int 52 49 7 31.3 -34.0 12 Int 36 26 7 32.5 -35.2 13 Int 52 49 7 31.3 -34.0 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1