Loading...
HomeMy WebLinkAboutPermit Worksheets•' i"• C - • •u• ...j : . r. • , • • • `' !'EF iVI IT ih(O R�CSF`1EE'T P 9e Y ®f 2 • ski+ . NUMBER Installer _aW wj e. - R ...r-M tom? License # _Dl 4 -to I / Z �( New Home . ® Used Home Home installed to the Manufacturer's Installation Manual [� Address cf home e I S � � 1"' being installed Q Home is installed to accordance with Rule i5-C13 ILL Manufacturer Length x width ? y X ? �®n Singie wide fjuble wide ' ® RPLU Wind Zone I Wind Zone Ili Installation Deca'i�-d�." _ NOTE; W home Is a,single wide fill out one half of the blocking plan li home is a triple or quad wide sketch In remainder of home ® plelQuad W Q- Serial # f aD } I understand Lateral Arm Systems cannot be used on any home (new or ed) LU where the sidewall ties exceed 5 ft 4 in, ,. �-� " _ PIER SPACING TABLE FORUSED HOMES Installer's initials_ <'� Typical pier s dCinq if �� lateral ® t cad Poorer bearing' size181/�' capacity (sq ir1) tE56 ) X 181/2' 20' X 20' 342 ( ) (400) 22' X 221 24' X Z4' ae• X Z6' (48 (576)• (576) PIER PAD SIZES I-beam pier pad size t Y Z Z Perimeter pier pad size l _/ X Z Z Other pier pad sizes (required by the mfg.) MIDraw the approximate locations of marriag wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and.their pier pad sizes below. Opening Pier pad:size - !S- 351 r`_k zZ- POPULAR PAD SIZES ANCHORS Oft FRAME TiES within 2' of end.of home spaced at 5' 4" oc TIEDOWN OOMPONENTs OTHER TIES L.ongltudlnal sfablllxing Device (L-SD) Number - -- - - Sidewail Manufacturer W W . Longitudinal Longltudlnal Stabblllaing Device W a ral ArMs �4 Marriage wall Manufacturer 1/4l N ur" �� +t' Shearwall At PERMIT NUMBERk; s�; ;� > r: ; , \yr 2 4Y POCKET PENETROMETER TEST ; The pocket penetrometer tests are rou ded wn to psf or check hereto declare 1000 lb. soil without testing. X X X POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the horde at 6 locations. 2. Take the reading at the depth of the.footer, S. Using 500 lb. increments, take the lowest reading and round down to that increment. X TORQUE PROBE TEST The results of the torque probe test is inch pounds or check here if you are declaring V anchors without testing . A test showing 275 inob pounds or less will require 5 foot anchors. Note: -A state approved lateral arm system is being used and 4 ft. .anchors are allowed at -the sidewall locations. i understand 51 anchors are required at all centerline tie points where the torque test reading Is 275•or less and where the Mobile home manufacturer may requires anchors with 4000 lb holding capacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED 11gSTALLER Installer Name W � NAIR_ 6.11d, A,—d- co-ce Date Tesfed Electrical Ibnneot electrical conductors between multi -wide units, but not to the main power ource. This•includes the bonding wire between molt -wide units. Pg. onneot ail sewer drains to an existing sewer tap or septic tank Pg. onnect all potable wafer supply piping to arws i i g water meter, water tap, or other idepandent water supply systems, Pq. PERMIT WORKSHEET page 2 of 2 Site Preparation Debris and organic material reMoved Water drainam Naturaly Swale Pad Other__T, Fastening multf wide units Al Floor. - Type Fastener. Lam_ Length: 0 Spacing: Walls: Type Fastener. Length: 0/_ Spacing: �</ — Q� Roof: Type Fastener. - c Length Spacing: For.used homes a min. 30 gauge,;8" wide, galvanized metai strip will be centered'over the peak of the -roof and fastened With gals. roofing nails at 2" on center on both sides of the centerline, 1 understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew Arid buckled marriage walls are a result of a poorly installed or no gasket being installer], .I un, erstand a strip of tape will not serve as a gasket. Installer's initials Type gasket / `~ installed: Pg. Between Floors Yes Between Walls Yes c/ Bottom of ridgebeam Yes Weatherproofing The bottomboard will be repaired and/or taped. Yes Pg._ Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney Installed so as not to allow intrusion of rain water, Yes /�i9 MlsaeltaneoUs Skirting to be.installed. Yes I.",- No Dryer vent installed outside of skirting. Yes ✓N/A Range downflow vent installed -outside of skirting. Yes N/A Drain lines supported at 4 foot intervals, Y� Electrical crossovers protected. Yes Other: - verifies all information given, with this pe is accurate and true based -an the Installer Signature Datelt/�