Design Pressure Report (Schmied) - Master Craft Aluminum Products
Property Information Owner:Schmied Address:519 Paurotis Ft Pierce, Fl 34982 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 52 37 7 38.6 -42.0 2 Int 109 49 7 36.0 -39.4 3 Int 25 49 7 39.4 -42.7 4 Int 25 37 7 39.4 -42.7 5 Int 52 49 7 37.9 -41.3 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1