Loading...
HomeMy WebLinkAboutDesign Pressure Report (Gram) - Master Craft Aluminum ProductsProperty Information Owner:Gram Address:6666 Tulipan Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 74 64 7 30.0 -32.7 2 Int 37 64 7 31.4 -34.2 3 Int 53 40 7 31.7 -34.4 4 Int 128 88 7 28.1 -30.9 5 End 336 88 7 25.6 -29.7 6 End 111 51 7 29.6 -37.7 7 Int 26 52 7 32.5 -35.2 8 Int 26 52 7 32.5 -35.2 9 Int 26 39 7 32.5 -35.2 10 Int 53 52 7 31.1 -33.9 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1