HomeMy WebLinkAboutDesign Pressure Report (Emskamp) - Master Craft Aluminum ProductsProperty Information Owner:Emskamp Address:19 Florida Way Port St Lucie, Fl 34952 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 26 39 7 32.5 -35.2 2 Int 37 63 7 31.5 -34.2 3 Int 37 63 7 31.5 -34.2 4 Int 26 39 7 32.5 -35.2 5 Int 74 63 7 30.0 -32.8 6 End 106 84 7 28.6 -35.8 7 End 106 84 7 28.6 -35.8 8 Int 108 84 7 28.6 -31.3 9 Int 52 55 7 31.0 -33.8 10 Int 52 55 7 31.0 -33.8 11 Int 26 39 7 32.5 -35.2 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1