HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY' EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE ROYALE IMPACT
BuilderName: WYNNE
Street: WYNNE DEV.'
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner: �.%- -l-) �V
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans) .
9. WallTypes.(1688.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int'insul, Exterior
R=4.1 1448.70 ftz
3. Number of units, if multiple family 1
b. Frame- Wood, Adjacent
c. N/A
R=11.0 240.00 ft2
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1750.0 sqft.)
Insulation Area
a, UnderAttic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floorarea above grade (ftz) 1720
b. Knee Wall (Vented)
R=19.0 30.00 ft2
.Conditioned floorareabelowgrade(ftz) 0
c. N/A
R= ft2
7. Windows(!! 5.4 sgft.) 'Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 155
a. U-Factor: Sgl, U=.1.04 115.42 ft2
SHGC: SHGC=0.29
b. U=Factor: Sgl, U=1.11 40.00 ftz.
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15:00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1720.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits .
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.10
PASS
Total Baseline Loads: 56.25
I hereby certify that the plans and specifications covered by
Review of the plans and:
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance,,;
a
with the Florida Energy Code.+
PREPARED BY:
Before construction is. completed
.b
DATE: 4-2&-2020
this building will be inspected for
compliance with Section 553.908
41
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
4y
with the Florida Energy Code.
OWNER/A NT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier'and Insulation I e t'o ec t i accordance with R402.4.1A and this project requires
an envelope leakage test report with envelope lip
MA h i CH50 (R402.4A.2).
CODE COMPLIANCE
IT® LQ.JCIE CC)I.INI'�P' ov
sOCC FIU:
4/20/2020 2:55 PM EnergyGauge® USA 6:0.02 (Rev:1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY'CHECKLIST REPORT
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
Street Address
'BuildingType: User
Conditionedkea' 1720
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst.Case: Yes
PlatBook:
BuilderName: WYNNE
RotateAngle:. 90
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Designtocation
Design Temp
TMY Site 97.5 % " 2.5 %
Int Design Temp
Winter Summer
Heating Design DailyTemp
Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1720 13760
SPACES
Number. Name;
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished :Cooled
. Heated
1 BEDROOM
343 2744 No 0
1
1
Yes
Yes
Yes
2 WIC
63 . 504 No 0
1
No '
Yes
Yes
3 M.BATH
56 448 No 0
1
Yes
Yes '
Yes
4 KITCHEN
172 1376 Yes 0
1
No
Yes
Yes
5.- BATH
45 360 No 0
1
Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1
Yes
Yes
Yes
7 ENTRY
98 784 No 0
1
Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1
Yes
Yes
Yes
9 GREAT/DINING
528 4224 No 0
1
Yes
Yes
Yes
10 BEDROOM 3
169 1352 No 1
Yes
Yes
Yes
FLOORS.
# FloorType
Space Perimeter PerimeterR.-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab-On-GradeEdge Insulation
BEDROOM 52ft 0.
343ft2
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
-___
0 1
0
3 Slab -On -Grade Edgelnsulation
M. BATH .8 ft 0
56 ft2
____
0 1
0
4Slab-On-Grade Edge Insulation
KITCHEN 1 ft 0
172ft2
____
0 1
0
5 Slab-On-GradeEdgeinsulation
BATH . 5 ft_ 0
45 ftz
____
0 1
0:
6SIab-On-Grade Edgelnsulation
BEDROOM2 42.6ft 0
264ft2
____
0 1
0
7 Slab-On-GradeEdgelnsulation
ENTRY 6.3ft 0
98ft2
0. 1
0
4/20/2020 2:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT -SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType Space Perimeter PerimeterR-Value
Area
Joi.stR-Value
.Tile Wood Carpet
8Slab-On-Gr6de Edge Insulation LAUNDRY 6ft
0
42ft2
_ _
0
1
0
9Slab-On-Grade Edge Insulation GREAT/DINING 48ft 0
528ft2
____
0
1
0
10SIab-On-Grade Edge Insulation BEDROOM 13ft 0
169ft2
____
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt . Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor..
Tested
Tested Insul.
(deg)
1
Gable orShed Metal 1813 ft2
286 1`12
Light
N
0.6
No 0.7
No 0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic BEDROOM
30-
Blown:
343ft2
0.1.
Wood-
2
UnderAttic(Vented) WIC
30
Blown
63ft2
0.1
Wood
3
Under Attic (Vented), M. BATH
30
Blown
56ft2
0.1
Wood
-4
Under Attic (Vented) KITCHEN
30 .
Blown
172 ft2
0.1 '
Wood
5
UnderAttic(Vented) BATH
30
Blown
45ft2
0.1
Wood
6
UnderAttic (Vented), BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
36
Blown
98ft2
0.1
Wood
8
UnderAttic(Vented) LAUNDRY
30
Blown
42ft2'
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM
30
Blown
169ft2
0.1
Wood.
11
Knee Wall (Vented) GREAT/DINING
19
Blown
30ft2
0.11
Wood
WALLS
Adjacent To vvallDpeSpace Cavity Width
Height
Sheathing .Framing Solar Below
1
N=>E
Exterior Concrete Block - Int Insul BEDROOM
4.1 9
0 8
'0
72.0 ft2
0
0
0.4
0
2
S=>W
Exterior Concrete Block - Int Insul BEDROOM
4.1 29
0 8
0 -
232.0 ft2
0
0
0.4
0
3
W=>N
Exterior Concrete Block - Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4
S=>W
Exterior Concrete Block - Int Insul, M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5
N=>E
Exterior Concrete Block - Int Insul BATH'
4.1 51
0 8
0
40.0 ft2
0
0
0.4
0
6
N=>E
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
7
NE=>SE Exterior Concrete Block- Int InsuBEDROOM2 '4.1
2
10 8
0
22.7 ft2
0
0
0.4
0-
8
E=>S
Exterior. Concrete Block- Int InsuBEDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
9
SE=>SW Exterior Concrete Block- Int InsuBEDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
10
S=>W
Exterior Concrete Block - Int InsuBEDROOM 2
4.1 14
0 8
0
112.0 ft2.
0
0
0.4
0
11
NE=>SE Exterior Concrete Block- Int Insul ENTRY
4.1 1
5' 8
0
11.3 ft2 •
0
0
.0.4
0
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT S1LMMARY r14FC:K1 IST RFPnRT
WALLS
#
Adjacent Cavity Width
()Mt TO IAWITypeSpace . -
Height
Sheathing Framing Solar Below
12
E=>S Exterior Concrete Block- Int Insul ENTRY 4.1 5 0 8
0 40.0 ft2
soro
0 0 0.4
0
13
S=>W Exterior Concrete Block - Int lnsul LAUNDRY 4.1 6 0 8
0 48.0 ft2
0 0 0.4
0
_14
N=>E Exterior Concrete Block - Int lnsuI3REAT/DINT 4.1 28 0 8
0 224.0ft2
0 0 0.4
0
_ 15
W=>N Exterior Concrete Block- Int InsuIGREAT/DIN 1 4.1 20 0 8
0 160.0 ft2
0 0 0.4
0
16
N=>E Exterior Concrete Block - Int InsuBEDROOM 3 4.1 13 0 8
0 104.0 ft2
0 0 0.4
0
_17
N=>E Garage Frame -Wood BEDROOM -3 11 30 8
240.0ft2
0.23 0.4
0
DOORS
# Ornt DoorType Space Storms
U-Value
Width Height
Area
Ft
In Ft In
1 E=>S Insulated ENTRY None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/
Wall
Overhang
Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area Depth
Separation IntShade
Screening
1 W=>N 3 Metal Low-ESingle Yes 1.04 0.29 N
32.4 ft2 1 ft 0 in
1 ft 5 in Drapes/blinds
Exterior5
2 S=>W 4 Metal Low-ESingle Yes 1.04 0.29 N
6.9 ft2 1 ft 0 in
1 ft5 in None
None
3 E=>S 8 Metal . Low:ESingle Yes 1.04 0.29 N
23.2 ft2 1 ft 0 in
1 ft 5 in None
None
4 N=>E 14 Metal Low-ESingle Yes 1:04 0.29 N
36.8 ft2 1 ft 0 in
1 ft 5 in None
None
5 W=>N 15 Metal Low-ESingle Yes 1.11 0.27 N
40.0 ft2 10 ft 0 in
1 ft 5 in None
None
6 N=>E 16 Metal Low-ESingle Yes 1.04 0.29 N
16.2 ft2 1 ft 0 in
1 ft 5 in None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft2 300 ft2 30 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000356 1605.3 88.13 165.74 .1233
7
HEATING SYSTEM
# System Type Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING. SYSTEM
# SystemType Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/ Split Single SEER: 15 34.8. kBtu/hr cfm 0.85 1
sys#1
4/20/2020 2:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY• CHFCKLIST RFPnRT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System Model# CollectorModel# Area Volume 'FEF
None None
ft2
DUGTS
/ -- Supply---
--- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 _ 155 ftz
Attic
55 ft2
DefaultLeakage
Attic
(Default) c(Default) c •
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinH Jan H Feb
Mar
M Mar
Apr
f APr
May
f May
Jun Jul
Jun Jul
Auge
AuSep
Oct HNov
f Oct Nov
Dec
HDec
VentingJan Feb
Mar
[x] A r
[ May
Jun Jul
Aug
Se
[X) Oct Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4
5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
80 80 80
80
PM
80
80 78
.78
78 78
78
78
78 78 78
78
Cooling(WEH) AM
78
78 78
78
78' •78
78
78
78 78 78
78
PM
78
78 78.
78
78 78
78
78
78 78 78
78
Heating(WD) AM
66
66 66
66.
66 '68
68
68
68 68 68
68
PM
68 •68
68
68
68 68
68
68
68 68 66
66
Heating(WEH) AM
66
66 66
66
66 68
68
68
68 68 68
68
PM
68
68 68,
68
68 68
68
68
68 68 66
66
MASS
Mass Type
Area
'Thickness'
Furniture Fraction
Space
Default(8lbs/sq.ft.
O. ft2
0 ff
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.,
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
BE 2
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
GREAT/DINING
Default 8lbs/s .ft.
W
ft .
0.3
BEDROOM 3 .
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
'2017 --*AIR BARRIER AND]N.SULATION 'INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
U
ui
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A -continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
-not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air.barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill.platei shall be sealed..
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material havingthermal resistance of R-3
Knee walls shall be sealed.
.a
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The.space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be -installed to
(including
insulation.
maintain permanent contact with the underside, of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut -to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on, exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electric0phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the subfloor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended. by the manufacturer..
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire snri kler cover plates and walls or ceilln s
a. In addition, inspection of log'walls'shall be in accordance with the provisions of [CC-400.
4/20/2020 2:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
• ' ; 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy
Performance Index,
the,more efficient the home.'
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Sinole-family
:b) Return.ducts R
6.0
- c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: :Capacity .
34.8
a) Split system SEER
. 15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1120
d) Room unit/PTAC EER .
e) Other
7. Windows, type and area
a) U-factoe(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
155.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF .
8. Skylights _
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas . AFUE
b) Solar Heat Gain Coeffiicient(SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level;
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Woodframe (Insulation R=value)
10A1.
e) Dedicated heat pump with tank EF
2: Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit, HeatRec%
B. Adjacent:
g) Other
1.- Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation ,
No
b) Single assembly
11b.
c) Whole house'fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building.Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida. Building Code, Energy Conservation, through the above energy
saving features which wilfbe installed (or exceeded) in. this home before final inspection. Otherwise,.a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: WYNNE• DEV. ���� 7 A_2111JC" City/FL Zip: FT. PIERCE. FL '3 -A9 S'
4/20/2020 2:55:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1