HomeMy WebLinkAboutTrussA-LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
SPACING NOTE
TRI OSE AR:- BE 5E
AT 2 -C ONTER
EXCE Ar- ic0_ED Ali
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
`NGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY. All
30' Span or less 30' to 60' Span
Io degrees Spreader Bar
cc _
L iog �_. APprox 2/3 to_-�
Lin BIJ Or'. � DprLine 1/2 of Span
REFER 71 BCS REFER TO BCSI
Tress ^rosT be set to s way.' were _sad. Truss must be set this way If crane used.
r_ss's an e.nr,,e, yc, it-ss m ntnn. --is is on exomole, truss may not match.
�^sst crone operator set, Vass the by, Insist crone operator sets truss this .way..
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
® are installed.
A I FR 1--1 A N C 1— Ill F2 N C> T
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAYBE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
package.
Carrying Girder
Nails must be as
shown. Guide tabs o
Dome angle nails.
SEAT PLATES BY CHAMBERS
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-l"
ABOVE FINISHED FLOOR
12
4.00
u5I(O'i 8,-1,t
heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
BEARING HEIGHT 8' 1"
TYPICAL END DETAIL
3
ARRANGE WITH (O.'JNRANE OPERATOR
{ D, not stand on trusses
mom
14'
14'
._ 1 „
2 118
2'-1 1 ^
16
- N
up
aD
m
eD
m
W
W
W
m
CO
CD
m
fp
Y
N
s
r
a-
i�
J2
J2
J4
c+0
J6
41b
J6
GRC
A6
A4
1
A3
I
I
A2
1
At
I
At
1
Al
aD
Al
1„
13-72
/121 1 IN .
Al
I
Al
All
I
Al
...
Al
_...».
'..,
A
A
jA
� 0 of77
O
>_. . N
A
O�5
-
I
QQO�
A
W L)
Qz
A
W U)
IY C6
w_
A
z
z
O
A
N
C7
j
A
T SETBACK BOSTON HIP TRUSS '
BH7
GRB r`
>
;
J3:
B
A
B
M - - - - - -
B
=
of I
GRA
I 1
-- — — — -- — — — — — — —. — — — — — — — - — — — — 1
— — JC ro JC o
NI 1
N- - - - - - - - - - - - - - - - - - - .4 -
- - - - -
15' 10„
5` 4" 2'-2" 9'-6" 2,-2"
- --
35'
GARAGE
LEFT
ENGTH
properly Haile POs raps
ngers
35' "
- 21 -
14'
2' 11"
—
2 -116"
16
I
I
c-.
iv
J2
iv
J4
00
\
�^
o
J6.
�eNX,
.\
J6
I
GRC
00
A6
A4
A3
A2
At
7777�
Al
N
Al
121 2 INT.
13'-71,1
2
Al
i
1
Al
Al
114
'I
CID
7777
Al
O
��\
Al
,n.
A
A
2
W ED O .
A
N LL
Z
A
~
03 W J d
A
ijL)
o
Qz
1w..UO
A
gym¢
w_
Z Z
A
OT
io
(N
Cl)
:..A
T SETBACK BOSTON HIP TRJSS
BHT
F GRB
B zr) J3
s
B J1
B
I I
GRa
o
I
Jc N JC ro
-_------- --- ----------- -
I
I
N. I
(V `� it
a - ---—+---- - - - -acN
-- - ------ ---�-
1 -84"
2' 2" 9' 6" 2'-2" 5'-4" 15'-10"
REVS
35'
CODE
FABRICATION AGREEMENT
TRUSSES CANNOT 9E STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description Oft e property where the trusses wJi be Installed is;
The undersigned acknowledges and agrees: ---�_
1; Trusses will be made in strict accordance with this trussplacement diagram layout,
which is the sole authority for determining. successful fabrication of the trusses
2. Atl dimensions In this layout have been verified by the undersigned. .3. Unless written notice Is provtded by certified mall to Chambers Truss within ten (f 0)
days of delivery the undemlgned agrees that no backcharges will be allowed In the event
such written notice Is famished Chambers Truss shall have three (3) bussiiness days In wiYlch
to begin repairs required, or to su 13utuIs bthec trusses at Chambers o0ui' .
4. Tha undersigned acknowledges receipt of "SCSI i-03" summary sheet by T & yvTCA.
6. Delivery is to Job site. It Is the buyefa'rasponalblliry fo make the Job site suitable for
delvery. Chambers Truss has the sole authority to detemslno the suitability of the Job at o} a
portion of the Job Bite for delivery. Chambers Truss will be responsible for dump delivery only,
The buyer Is responsible for additional delivery expenses if Chambers Truss has to redeliver
use Job ske Is not preDarad for delivery or buyer Is not prepared !or delivery oft russes,
3v, la rsponaible tc Chambers Trues for towing costs due to site conditions.
8. Price es shown Iq paragroph7 below Is subject to change If any changes are. made In
this layout. A $50 per hour fee for revislons may be charged by Chambers Truss,
7: This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If no
agreement a reasonable pries, Invoice will be made on delivery and paid within terms of net
on delivery. invoice may be made at scheduled date of delivery If buyer cannot accept-
delivery of fabricated trusses,
The undersigned agrees to pay Chambers,Trysa reasonable
attorney's fee for collections In event of payment not timely made, 1.12 Yr, per.. . service
charge will be added for all sums not paid within terms,
. 8, Signature orJnitlals anywhere on this sheet constitutes agreement to allterma herein.
9:In consideration of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and ail Indebtedness owed to
Chambers boas by,any entity to INng atonal and the undersigned agrees to pay such
Indebtedness Including attomeys fees, If default in payment for10. In the material he made by the
recipient. '.
vent of any
gation
ng
e ito
or payments referred to helrlein, the. Partiesrlagrfeesthat the so,, v nuems for any such hereunder
be Saint lucre County, Florida.actlonwill
11. Desig
n responsibilities are psr "National Standard And RecommendedTrusses
Guidelines On
Raeponslblllues For Construction Using Metal Plate Connected Wood Trusses
ANSIRPI/VJTCA 4 - 2002". .
DATED
SIGNED
FOR TITLES`
Aspreader barmaybe tegi{eed per'8_CSI 1-03" to Plederlt 1rjury& darriaa
Multiple ply trusses must be fastened together per enginee'rfng
before they are set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life
and property and is the responsibility of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Tnffiaes must be setarid braced perdeslgn tr prevent iNUry& daiilags.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
other concentrated loads on trusses this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
e
3105 Oleander Avenue
Fort Plercei Florida 34982-6423
800-551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach T72v''69-2012 Stuart 772-286.9302
The Architect's or Architect's represetstative's .-
shop drawing approval is NOT
"double check" of the contractor.
The contractor shall remain, responsible
for checking field measurements and
other construction criteria,. Architect's
approval covers:�neral roof shape,
review of truss ittraipping, and loading on
structure from gra y and uplift loads and
their res ec ive local io s
Approved 3
Date: ----
Braden & Braden A.I.A. P.A.' —
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
J Building Department ST LUCIE COUNTY
� Wind Design Criteria ASCE 7-2010
>° " 0 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
� � � � Roofing Material Metal Roof
Loading in PSF Roof R.D.L.
° Top Chord Live 20
o � c —Top Chord Dead 7 4.2
N Bottom Chord Live 10 Non -Concurrent
� C y
m o Bottom Chord Dead 10 3
R TOTAL Load 37 7.2
N Duration Factor 1.25
yrJ Wind Speed 165mph
v Top Chord C.B. Sheeting by builder.
Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 12'-0"
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017 I
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
�/ Chambers Truss Inc. Drawing Name: M11324
0L Scale: 1/4 = 1'
' ' I 83 total trusses, 27 different trusses.
W MI 4: SAE ACAD: SAE Reviewed By:
Date:07/19/12 Revised`:03/21118
FOR Revised: 3/05/2020
EFORNYNNE BUILDING CORP.
CO IAN �, rSCRIPTION:
GARAGE RIGHT sT. �.uc� uN OYALE 7�7-73(,z:2
R
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
27 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11324 1 gq-7-7
MiTek'
RE: ml1324
THE ROYALE
Site Information:
Customer: WYNNE BUILDING CORPORATION Project Name: ml 1324
Lot/Block: Model: ROYALE
Address: UNKNOWN
City: ST LUCIE
Subdivision:
State: FL
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014
Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10
Wind Speed: 165 mph
Roof Load: 37.0 psf
Floor Load: N/A psf
This package includes 27 individual, dated
Truss Design
Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby
certify that I am
the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name
Date
No. Seal# Truss Name Date
1 T19781776 A
5/5/2020
21 T19781796 JC 5/5/2020
2 T19781777 Al
5/5/2020
22 T19781797 KJ5 5/5/2020
3 T19781778 A2
5/5/2020
23 T19781798 KJ8 5/5/2020
4 T19781779 A3
5/5/2020
24 T19781799 KJA 5/5/2020
5 T19781780 A4
5/5/2020
25 T19781800 KJB 5/5/2020
6 T19781781 A6
5/5/2020
26 T19781801 MV2 5/5/2020
7 T19781782 B
5/5/2020
27 T19781802 MV
8 T1978178BHA
5/5/2020
05/5/2020
r%y
9 T19781784 GRA
5/5/2020
ti C
10 T19781785 GRB
5/5/2020
11 T19781786 GRC
5/5/2020
12 T19781787 J 1
5/5/2020
13 T19781788 J2
5/5/2020
munoo 6ui��rwaad
G
14 T19781789 J3
5/5/2020
RED$'
15 T19781790 J4
16 T19781791 J5
5/5/2020
5/5/2020
C®®E WMPLIANCE
17 T19781792 J6
18 T19781793 J8
5/5/2020
5/5/2020
ST. LUCWeOUNTY
19 T19781794 JA
5/5/2020
R—
20 T19781795 JB
5/5/2020
,��••..
oc'4�.r
This item has been electronically signed and sealed by ORegan, Philip using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision
based on the parameters provided by Chambers Truss.
%%%
C''9
Truss Design Engineer's Name: ORegan, Philip
%%, `Z`�y'' b E N •'• ��i
SF•••. L �'.
My license renewal date for the state of Florida
is February
28, 2021. •'•��
Florida COA: 6634
No 581261.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
'0:•
/STATE OF •:��/
0sO N A1- EG %�
��//111111110%
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 May 05, 2020
1 of 1 ORegan, Philip
Job
Truss
Truss Type
Ply
THE ROYALE
T19781776
M11124
A
COMMON r
�Qty
10
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 1
ID:_k8GCA6bx7j2Syl HDXFw7ye3KX-bdFkwKP1 WVd5kvh4gXmgUQgkzjKtK4bfmPcjqXzXjGq
1-0-0 8-4-0 12-11-0 17-6-0 22-1-0 26-8-0 35-0-0 6-0
-0-0 8-40 4-7-0 4-7-0 4-7-0 4-7-0 8.4-0 0-0
�1
O
4.00 12
45 =
Scale = 1:59.3
17 '- 15 -" -" 14 '- 12
4x5 — 2x3 II 5x6 WB = 3x8 = 2x3 II 4x5 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
OTHERS
2x4 SP No.3
3x8 =
5x6 WB =
4-0
12-11-0
22-1-0
26-8-0 35-0-0
4-0
4-7-0
9-2-0
4-7-0 8-4-0
SPACING-
2-0-0
CS1.
DEFL.
in (loc) I/defi Ud
PLATES GRIP
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.33 14-15 >999 360
MT20 244/190
Lumber DOL
1.25
BC 0.68
Vert(CT)
-0.64 14-15 >652 240
Rep Stress Incr
YES
WS 0.63
Horz(CT)
0.13 10 n/a n/a
Code FBC2017/TP12014
Matrix -MS
Weight: 169 lb FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-1-13 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 4-10-7 oc bracing.
REACTIONS. (lb/size) 2=139910-8-0, 10=1399/0-8-0
Max Horz 2=-223(LC 8)
Max Uplift 2=-775(LC 10), 10=-775(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3404/2226, 3-5=2807/1885, 5-6=-2801/1990, 6-7=-2801/1990, 7-9=-2807/1885,
9-10=3404/2226
BOT CHORD 2-17=1946/3218, 15-17=-1946/3218, 14-15=-1116/2053, 12-14=-1946/3188,
10-12=-1946/3188
WEBS 6-14=-598/1034,7-14=252/246, 9-14=-702/541, 6-15=-598/1035, 5-15=-253/246,
3-15=701 /541
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2)12-8-6
to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 100.O1b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.59126
MiTek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTekrSl connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781777
M1ie324
Al
SPECIAL .f
�Qty
9
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:18 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-3gp67gQfHplyL3GGEEHv1 dDr47c?3X1 o?3LG"jGp
1-0-0 7-8-0 13-71 17-6-0 23-11-12 26-9-10 35-0-0 6-0
-0-0 7.8-0 5-11-8 3-10-8 6-5-12 2-9-14 B-2.6 -0-0
Scale=1:60.3
5x8 MT18HS =
4.00 12
1 Icb
14 13
3x5 = 2x3 11 5x12 = 3x12
2.00 12 =
7-8-0i 13-7-8 i 23-11-12 i
35-M
711 5-11-8 1044
11-0-4
Plate Offsets (X Y)—
[2:0-1-2 Edge] [8:0-3-0Edge] [10:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deb. Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.89
Vert(LL) 0.80 12 >525 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.94
Vert(CT) -1.39 12-13 >302 240
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.62
Horz(CT) 0.37 10 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 159 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied.
WEBS 2x4 SP No.3 *Except* WEBS 1 Row at micipt 6-12
6-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-223(LC 8)
Max Uplift 2=-825(LC 10), 10=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3309/2433, 3-5=-2581/2012, 5-6=-2548/2113, 6-7=-5337/4002, 7-9=-5302/3868,
9-10=-5702/4143
BOT CHORD 2-14=-2151/3113, 13-14=-2151/3113, 12-13=-1450/2202, 10-12=-3809/5431
WEBS 3-14=01265, 3-13=-813/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/3388,
7-12=-298/368,9-12=-405/352
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterlor(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Extedor(2) 12-8-6
to 17-6-0, Interior(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
electronically signed and
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
sealed by ORegan, Philip, PE
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
using a Digital Signature.
capacity of bearing surface.
t lne Pfd copies Of this,
P
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall MiTek*
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iViiTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781778
M1 i924
A2
SPECIAL 7
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-XONULORH26uozDrSoyo8Zr13jXxjoyGyEj5gvozXjGo
n1-0-0 8-0-1 13-7 8 16 O 0 19-0-0 23-11-12 26 9-9 35-0-0
-0-0 8-0-1 5 7-7 2-0 8 3-0-0 4-11-12 2-9-13 8-2-7 0-0
�1
6
4.00 12
5x6 = 4x4 =
Scale = 1:62.3
3x8
5x10 7 5x6
34 89
22 23
12
2 10 11 n m
13 6x10 MT18HS = I
14 3x10
15
2x3 11 5x6 =
3x5 = 2.00 12
3x12 Zz
8-0-1 13-7-8 19-0-0
23-11-12
35-0-0
8-0-1 5-7-7 - 8
4-11-12
11.0.4
Plate Offsets (X,Y)—
[2:0-1-2,Edge], [4:0-2-12,0-3-0], [4:0-0-0,0-1-12], [8:0-3-0 Edge], [8:0-0-0,0-1-12], [9:0-3-2,0-0-0[, [10:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.70
Vert(LL)
0.75 12
>559
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT)
-1.02 12-21
>412
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.75
Horz(CT)
0.37 10
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 160 lb
FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 WEBS
REACTIONS. (lb/size) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-205(LC 8)
Max Uplift 2=-825(LC 10), 10=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6=-2524/1699, 6-7=-2672/1734, 7-9=-5246/3199,
9-10=5687/3567
BOT CHORD 2-15=-1849/3111,14-15=-1849/3111,13-14=-1217/2314,12-13=-2804/5025,
10-12=-3257/5414
WEBS 3-15=0/300, 3-14=-954/692, 5-13=-206/561, 6-13=-357/632, 7-13=-2796/1678,
7-12=1082/1957,9-12=-479/463
Structural wood sheathing directly applied or 2-4-8 oc puffins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
1 Row at midpt 7-13
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. ORegan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE,
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOWis always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-B9 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781779
M1f924
A3
SPECIAL
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fart Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:20 2020 Page 1
ID:—kfiGCA6bx7j2Syl HDXFw7ye3KX-7CxsYMSvpQOfbNQfLfJN621EjxHyXPZ5SNgNRszXjGn
8-0-1 14-0-0 21-0-0 23-11-12 26 9-10 _ 35-0-0 a6.0.q
-0-0 8-0-1 5-11-15 7-0-0 2-11-12 2-9-14 8-2-6 1-0-0'
3x5 =
5x6 =
46 =
d_nn r1_9 4 D 3xR
13
2x3 11 5x6 =
2.00 12
3x12
Scale=1:61.3
8-0-1 13-7-8
21-00
23-11-12 _, 35-0.0
8-0-1 5-7-7
7 4-8
2-11-12 11-0-4
Plate Offsets (X Y)—
[2:0-1-2 Edoe] [8:0-1-15 Edoe]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Well Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.69
Vert(LL)
0.72 10 >582 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -0.98 10-19 >427 240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
WB 0.74
Horz(CT)
0.35 8 n/a n/a
BCDL 10.0
Code FBC2017/rPI2014
Matrix -MS
Weight: 158 lb
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-5-0 cc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 cc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 8=1349/0-8-0
Max Horz 2=-181(LC 8)
Max Uplift 2=-825(LC 10), 8=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=3286/2122, 3-4=-2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7=-5214/3232,
7-8=-5695/3643
BOT CHORD 2-13=-1853/3079, 12-13=-1853/3079, 11-12=-1338/2410, 10-11=-2826/4982,
8-10=-3331/5422
WEBS 3-13=0/293, 3-12=-854/595, 4-11=-480/959, 5-11=-360/724, 6-11=2280/1355,
6-1 0=-1 118/1934, 7-10=-530/515
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 8 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint B.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITeM connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781780
M1 M324
A4
SPECIAL
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xb2cz2T9L1 GNggal T4MrBTNaQkzc?IfOwhJUWIzXjGI
�1-0-0 6-5-8 i 12-0-0 17-8-4 23-0-0 23,-11-1,2 26-9-9 , 35-0-0 3s-0-a
-0-0 6-5.8 5.6.8 5-8-4 5-3-12 0.11-1 2-9-13 8-2-7 �-V
4.00 12
3x6 =
5x6 = 3x4 =
14 13 3x4
3x4 = 54 =
2.00 12
5x8 =2x3 11
6 7
3x12
Scale=1:61.3
o 7-
0
1
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0
Max Horz 2=157(LC 9)
Max Uplift 2=-825(LC 10), 9=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3367/2256, 3-4=3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301,
7-8=5219/3301, 8-9=5704/3714
BOT CHORD 2-14=-2000/3170, 13-14=-1488/2537, 12-13=-2065/3480, 11-12=-2440/4196,
9-11=-3399/5431
WEBS 3-14=-429/415, 4-14=-323/584, 4-13=-142/386, 5-13=-11251697, 5-12=-1411467,
6-12=861/437, 6-11 =1 145/2016, 8-11=542/518
Structural wood sheathing directly applied or 2-5-6 oc pudins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING- Verify design pammeters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall PYRE
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T19781781
M14324
A6
HIP ., j � f?, •
1. ",
1
Job Reference (optional)
cnamoers I russ, Inc., t-on merce, t-L t%l su s mar i i zuits ml i eK incusines, Inc. i ue mar z4 iz:o4:zs zuzu rage i
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-Pnc7AOUo6LOESg9E1 nt4khwkW8Mmktl Y9L312BzXjGk
i1-0-0 6-7-15 10-0-0 .13-8-0 21-4-0 25-0-0 28-0-1 35-0-0 as-o-a
0 0 6-7-15 3 4-1 3.8-0 7 8.0 3 8-0 3 4.1 6-7-15 -0-0
Scale = 1:60.3
5x8 = 24 II 2x3 II Sx8 =
4.00 12
4 23 24 5 25 26 6 27 28 7
16 15 14 13 12 11
4x5 — 3x4 = 4x5 = 3x4 = 3x4 = 4x6 _ 3x4 = 4x5 —
LOADING (psf)
SPACING-
2-M
CSI.
DEFL.
in (loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1:25
TC 0.71
Vert(LL)
0.60 11-13
>424
360
TCDL 7.0
Lumber DOL
125
BC 0.71
Vert(CT)
-0.78 13
>328
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.31
Horz(CT)
0.11 9
file
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0
Max Horz 2=-133(LC 8)
Max Uplift 2=-692(LC 10), 14=-219(LC 10), 9=739(LC 10)
Max Grav 2=1118(LC 1), 14=454(LC 19), 9=1206(LC 20)
PLATES GRIP
MT20 2441190
Weight: 153 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-6-3 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2600/2341, 34=2215/1960, 4-5=-2527/2290, 5-6=-2527/2290, 6-7=-2527/2290,
7-8=-2531/2224, 8-9=2880/2572
BOT CHORD 2-16=-207412444,14-16=-1569/2065,13-14=-1968/2527,11-13=-1833/2382,
9-11=-2290/2707
WEBS 3-16=495/599,4-16=-206/347,4-14=-541/820,5-14=-526/591, 6-13=-234/311,
7-13=-182/282, 7-11=-355/492, 8-11=-444/551
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2) 18-2-9
to 25-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at
joint 14 and 739 lb uplift at joint 9.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE 11111-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
m�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781782
M1M24
B
COMMON
�Qty
3
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:24 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-uzANOjVQtf W53JQaVOJGuT?gYo2TN IhN?oaadzxjGj
6-11-0 13-10-0
r 1-0-0 6-11-0 6-11-0
Scale: 1/2"=l'
4x6 =
Y)
Io
2x3
3x4 = 3x4 =
6-11-0
6-11-0
Plate Offsets (X,Y)—
[2:0-2-10,Edge], [4:0-2-10,Edge]
LOADING (psf)
SPACING- 2-M
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL) 0.10
5-8 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(CT) -0.13
5-8 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT) 0.01
4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 47 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural woad sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-7-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=510/0-8-0, 2=568/0-8-0
Max Horz 2=93(LC 9)
Max Uplift 4=-292(LC 10), 2=-377(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=967/954, 34=-966/952
BOT CHORD 2-5=-785/883, 4-5=-785/883
WEBS 3-5=-84/315
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; save=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall tt IV I�:
building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing iTek-
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCS/Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781783
M1'4324
BH7
BOSTON HIP
1
1
Job Reference D tional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:25 2020 Page 1
ID:_kriGCA6bx7j2Syl HDXFw7ye3KX-MAkib3W2dyeyh8lcBCvYp674vy5bCkwgcfY864zXjGi
15.6.0 21-6-0
i1-0-0 7-0-0 9-6-0 11.6-0 13.6-0 14-0.0 17-6-0 19.6-023-6.0 , 25-6-0 , 28-0 0 _ 35-0-0 36-0-0
-0.0 7.0-0 2-6-0 2-0-0 2-0-0 0.6 1-6-0 2-0.0 2-0-0 1-6-0 0-0- 2-0-0 7-" i-0-0'
Scale = 1:62.6
4.00 12 Sx6 =
4x6 = 3x8 = 3x4 = 4x6 = 3x6 =
3x5 =
7-0-0 14-0-0
21-0-0 28-0-0 35-0-0
7-0-0 7-0-0
7-0-0 7-0-0 7-0-0
Plate Offsets (X,Y)—
[2:0-1-2,Edge), [28:0-0-2,Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deb L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL) 0.51 32-33 >826 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.67 32-33 >628 240
BCLL 0.0
Rep Stress Incr YES
WB 0.48
Horz(CT) 0.14 28 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 208 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing.
WEBS 2x4 SP No.3
JOINTS 1 Brace at Jt(s): 11, 18, 15, 7, 23
REACTIONS. (lb/size) 2=1349/0-8-0, 28=1349/0-8-0
TOP CHORD MUST BE BRACED BY END JACKS,
Max Horz 2=-223(LC 8)
ROOF DIAPHRAGM, OR PROPERLY CONNECTED
Max Uplift 2=-825(LC 10), 28=-825(LC 10)
PURLINS AS SPECIFIED.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3392/2640, 3-4=-12131956, 4-8=-1157/946, 8-9=-1145/979, 9-12=-1122/1028,
12-14=-1125/1090, 14-16=-1124/1089, 16-19=-1121/1028, 19-22=-1145/979.
22-26=-1157/946,26-27=-1214/956,27-28=-3393/2641,3-5=-2373/2046,5-7=-2376/2050,
7-10=-2376/2050, 10-11=-237612050, 11-13=-2376/2050, 13-15=-2376/2050,
15-17=-2376/2050, 17-18=-2376/2050, 18-20=-2368/2046, 20-23=-236812046,
23-25=-2368/2046,25-27=-2364/2041
BOT CHORD 2-35=-2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32=-2361/3167,
28-30=-2358/3191
WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353,
14-15=405/437
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Extedor(2) 10-8-9
This item has been
to 17-6-0, Interior(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
electronically Signed and
3) Provide adequate drainage to prevent water ponding.
sealed by ORegan, Philip, PE
4) All plates are 2x3 MT20 unless otherwise indicated.
using a Digital Signature.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
`
Printed copies of this
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
document are not Considered
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signed and sealed and the
joint28.
signature must be verified
8) Graphical purin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd, Tampa FL 33610
Date;
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job •
Truss
Truss Type
city
Ply
THE ROYALE
T19781784
M15324
GRA
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:27 2020 Page 1
ID:_k8GCA6bx7j2Sy1HDXFw7ye3KX-IYsV01X19augwRS?GdxOuX5Zdrvglw73z1FByzXjGg
1-0 0 4-1-8 5-7-3 8-2-13 111 13-10-0 14-'10-0
1-0-0 4-1-8 1-5 11 2-7-9 1-5-11 4-1-8 1 0 0
2.37 12
4x4 = 4x4 =
4x10 4x10
19 4 20 21 5 22 6
2x3 II 3x4 = 3x4 = 20 II
3x4 =
3x4 =
Scale = 1:26.6
N
IA
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deb Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) 0.08
11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.32
Vert(CT) -0.10
10 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.06
Horz(CT) 0.03
7 n/a n/a
BCDL 10.0
Code FBC2017rFP12014
Matrix -MS
Weight 58 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-4-7 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-0-4 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 2=770/0-8-0, 7=77010-8-0
Max Horz 2=-65(LC 6)
Max Uplift 2=-523(LC 8), 7=523(1_C 8)
Max Grav 2=787(LC 17), 7=787(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=1798/1192, 3-4=-1761/1197, 4-5=-1724/1169, 5-6=-1761/1190, 6-7=-1798/1137
BOT CHORD 2-12=1083/1685, 11-12=-1082/1692, 10-11=-1112/1724, 9-10=-1024/1692,
7-9=-1028/1685
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 lb uplift at joint 2 and 523 lb uplift at
joint 7.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at
4-1-8. 85 lb down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and
129 lb up at 7-11-0, 113 lb down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 Ib up at
9-8-8 on top chord, and 6 ib down and 7 lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3. 39 lb down at 5-11-0
, 39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 Ib down and 7 lb up at 9-8-8 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-5=54, 5-6=-54, 6-8=-54, 13-16=-20
Concentrated Loads (lb)
Vert: 3=7(B)4=-64(B) 5=-64(B) 6=7(B)12=-6(B) 11=-35(B) 10=-35(B) 9=-6(B) 19=-28(B) 20=-60(B) 21=-60(B) 22=-28(B)
23=-18(B) 24=-18(B)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.56126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall rt 1�
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Intormadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss Type
Qty
Ply
THE ROYALE
T19781785
M1� 324
Puss
RB
SPECIAL
1
1
Job Reference (optional)
cnambers I russ, Inc., tort Pierce, t-L 6.1 su s Mar 11 2u16 Mi I eK maustrles, Inc. I ue Mar Z4 1404:26 2uzu rage i
ID: kftGCA6bx7j2Sy1HDXFw7ye3KX-mlQuE5YwwtOXYb1BpLSFRkdg49ACP4oHldmojOzxjGf
5-0-0 103-0 15-6-0 21-6-0 26-2-0 , 28-1-0 , 35.0-0 $6-0-Q
5.3-0 5-3-0 6-0-0 4.8-0 1-11-0 6-11-0 -0-0
2x3 11
4.00 12
48 =
30 =
3x6 =
3 25
26 4 27 28 29
5 630 31 32
v��Jr
�{ N1 2
"`111 ,iI
d
18 36
37 17 38 16 39
42
2x3 II
Sx1 =4041
3x4 =
3x4 = 3x6 =
Scale = 1:62.4
4x4 =
2x3 11 4x4 =
9
733 34 35 8
N
10 11 n
Imo;
0
14 4313 12
3x4 =3x6 = 3x4 = 3x4 =
5-0-0 10-3-0 1'61 21-6-0 28-1-0 35-0-0
5.0-0 5 3-0 5-3-0 6-0-0 6-7-0 6-11-0
Plate Offsets (X,Y)— (3:0-5-4 0-2-0)
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/de0
Ud
TCLL 20.0
Plate Grip DOL
1.25
TIC 0.41
Vert(LL)
0.11 17-18
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
-0.14 17-18
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.53
Horz(CT)
0.03 10
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
PLATES GRIP
MT20 244/190
Weight: 146 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 54-6 oc puriins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-15
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=96(LC 7)
Max Uplift All uplift 100 lb or less atjoint(s) except 2=-536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-314(LC
8)
Max Grav All reactions 250 lb or less at joints) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC
14)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595,
8-9=702/344, 9-10=-719/323
BOT CHORD 2-18=962/1659, 17-18=-958/1675, 15-17=-843/1406, 14-15=-595/429, 12-14=158/622,
10-12=-196/636
WEBS 3-18=0/331,3-17=-297/158,4-17=0/362,4-15=-2076/1313,6-15=505/480,
7-14=431/408, 8-14=-1063/625,8-12=-115/265
NOTES-
1) Unbalanced roof live loads,have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 lb uplift at
joint 15, 555 lb uplift atjoint 14 and 314 lb uplift atjoint 10.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at
5-0-0, 100 lb down and 129 lb up at 7-0-12, 100 Ib down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12, 100 lb
down and 129 lb up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 Ib down and
129 Ib up at 19-0-12, and 100 lb down and 129 lb up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-0-12, 39 lb
down at 9-0-12, 39 Ib down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 39 lb down at
19-0-12, and 39 lb down at 21-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
IdiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
P
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. f0103/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall r� Ar
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV IiTe k•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication• storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALS
T79781785
M1 1324
GRB
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:28 2020 Page 2
ID:_kriGCA6bx7j2Sy1 HDXFw7ye3KX-mlQuE5YwwtOXYb1 BpLSFRkdg49ACP4oHldmojOzXjGf
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-11=-54, 19-22=-20
Concentrated Loads (Ib)
Vert: 3=-160(F) 18=-45(F) 25=60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=60(F) 36=-13(F) 37=-13(F) 38=-13(F) 39=-13(F) 40=-13(F)
41=13(17) 42=-13(F) 43=-13(F)
®WARNING - Verify design parameters and. READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,111.7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p qr
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iUliTe k•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
7Q,
T19781786
M11324
GRC
HIP
1
Job Reference (optional)
r:namoers Truss, Inc., ron Tierce, rL d.13u s Mar 11 2u16 Mt l ex lncustnes, Inc. I Ue Mar L4 7z:o4:JU LULU rage 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-i7XeenZBSVGFnvBaxlvjW9jxmzm3tvGamxFvoHzXjGd
1-0-0 8-M 13-8-0 17-M 21-4-0 27-0-0 35-0-0
3 6-0
-0-0 8-0-0 -10-0 3-10-0 5-8-0 8-0-0 -0-0
Scale = 1:60.3
5x8 MT18HS =
4.00 12 2x3 11 3xB = 3x6 = 2x3 II
3 23 24 25 426 27 285 6 729 30 31 32
5x8 MT18HS =
8
16 33 15 14 34 35 36 37 13 38 12 39 11
3x5 = 2x3 II 3x6 = 6x10 = 6x10 = 3x6 = 2x3 II 3x5 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017rrP12014
CST.
TC 0.71
BC 0.67
WB 0.79
Matrix -MS
DEFL. in (loc) I/deft L/d
Vert(LL) 0.22 11-22 >999 360
Vert(CT) -0.31 13-14 >830 240
Horz(CT) 0.05 9 n/a n/a
PLATES
MT20
MT18HS
Weight: 157 lb
GRIP
244/190
244/190
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-5-6 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 5-9-3 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 3-14, 5-14
4-14,7-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0
Max Horz 2=-109(LC 6)
Max Uplift 2=-299(LC 8), 14=-2133(LC 8), 9=764(LC 8)
Max Grav 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-377/225, 34=-1093/1954, 4-5=-1093/1954, 5-7=-194311220, 7-8=-1943/1220,
8-9=-2776/1671
BOT CHORD 2-16=154/317, 14-16=160/350, 11-13=147512624, 9-11=-1464/2591
WEBS 3-16=200/679, 3-14=2514/1528, 4-14=-641/586, 5-14=-2674/1707, 5-13=1124/2080,
7-13=-592/548,8-13=760/483,8-11=-201/684
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
electronically signed and
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at
sealed by ORegan, Philip, PE
joint 14 and 764lb uplift at joint 9.
using a Digital Signature.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at
Printed copies of this
CO p
8-0-0, 107 lb down and 173 lb up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb
down and 173 lb up at 16-0-12, 107 lb down and 173 lb up at 16-11-4, 107 lb down and 173 lb up at 18-11-4, 107 lb down and 173
document are not considered
lb up at 20-114, 107 lb down and 173 lb up at 22-114, and 107 lb down and 173 lb up at 24-11-4, and 182 lb down and 312 lb up
signed and sealed and the
at 27-0-0 on top chord, and 411 lb down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at
signature must be verified
12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 lb up at 16-11-4. 79 lb down and
On an electronic copies.
1 lb up at 18-11-4, 79 lb down and 1 lb up at 20-11-4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4,
y p
and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility
Philip J. O'Regan PE No.58126
of others.
MiTek USA, Inc. FL Cart 6634
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
6904 Parke East Blvd. Tampa FL 33610
Data:
LOAD CASE(S) Standard
March 24,2020
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
r
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members oNy. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPH Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781786
M11324
GRC
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:30 2020 Page 2
ID:_kfiiGCA6bx7j2Syl HDXFw7ye3KX-i7XeenZBSVGFnvBaxlVjW9jxmzm3tvGamxFvoHzXjGd
LOAD CASE(S) Standard
1) Dead 4 Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20
Concentrated Loads (lb)
Vert: 3=-126(B)6=-107(B)8=126(B)15=-50(B)16=-411(B)11=-411(B)12=-50(B)23=-107(B)25=-107(B)26=-107(B)27=-107(B)28=-107(B)29=-107(B)
30=-107(B) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B) 36=-50(B) 37=-50(B) 38=-50(B) 39=-50(B)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a trusssystem. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�a
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOWis
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSHTPH Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781787
M11324
A
MONO TRUSS
2
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:312020 Page 1
ID: _k6GCA6bx7j2Syl HDXFw7ye3KX-AK5Os7apDoO5P3mmVTOy3NFEuMGVcYtj_a?SKjzXjGc
-1-0-0 1-0-0
1-0-0 1-M
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
TCDL 7.0
Lumber DOL 1.25
BC 0.02
BCLL 0.0
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC2017fTP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical
Max Horz 2=48(LC 10)
Max Uplift 3=-4(LC 7), 2=-140(LC 10)
Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale = 1:6.1
3x4 =
DEFL. in (loc) Udell Ud PLATES GRIP
Vert(LL) -0.00 5 >999 360 MT20 244/190
Vert(CT) -0.00 5 >999 240
Horz(CT) 0.00 4 n/a n/a
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cad 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and. properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSf?PII Quality Criteria, DS849 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781788
M11324
J2
MONO TRUSS
4
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
1-0.0
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:31 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AK50s7apDoO5P3mmVT0y3NFEuMFhcYtj_a7SKjzXjGc
2-0-0
Scale = 1:7.8
2-M
2-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(CT) -0.00
7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 8 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=28(1_C 10), 2=136(LC 10), 4=-3(LC 7)
Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 9=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint
2 and 3 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Informadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781789
M11324
J3
MONO TRUSS
2
1
'
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.130 s Mar 112018 MiTek Industries. Inc. Tue Mar 2412:54:32 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-fWfO3TbR_6Wyl DLy2AXBbaoPemaML?7sDEkOsAzXjGb
3-M
Scale = 1:9.4
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(Ice) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) 0.01
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) -0.01
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical
Max Horz 2=85(LC 10)
Max Uplift 3=-54(LC 10), 2=-147(LC 10), 4=4(LC 10)
Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIA ,7473 rev. f0/0312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for on Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall�e
building design. Bracing indicated 1s to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOWis always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information avallabte from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610
Job
Truss
Truss Type IQty
Ply
THE ROYALE
T19781790
M11324
J4
MONO TRUSS
4
1
4
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1
ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-7iDnHoc3lQepfMv9cu2QBoLW4AtR4SNOSuUZOczXjGa
Scale=1:11.1
4-0-0
4-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.02
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.02
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 14 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-79(LC 10), 2=161(1_C 10), 4=8(1_C 10)
Max Grav 3=97(LC 15), 2=206(LC 1), 4=67(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint
2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MN-7473 rev. f0103/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall r
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/RP1 f Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T19781791
M11324
JS
MONO TRUSS �
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:33 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7iDnHoc3lQepfMv9cu2Q8oLSAApH4SNOSuUZOczXjGa
-1-0-0 5-0-0 _
1-0.0 5-0-0
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.70
TCDL
7.0
Lumber DOL
1.25
BC 0.64
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017ffP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=115/Mechanical, 2=243/0-8-0, 4=63/Mechanical
Max Horz 2=123(LC 10)
Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=-9(LC 10)
Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:12.7
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
Vert(LL)
0.06
4-7
>939
360
MT20 244/190
Vert(CT)
-0.06
4-7
>964
240
Horz(CT)
-0.00
3
n/a
n/a
Weight: 17 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc pudins
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Carl 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIf►P/1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city,
Ply
THE ROYALE
T797B1792
M11324
J6
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:34 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-bvn9U8dhWjmgGWULAbZfg?tWa6ypvd9hYD6x2zxjGZ
6-0-0
6-0-0
Scale = 1:14.3
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/deb Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) 0.11
4-7 >664 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.80
Vert(CT) -0.11
4-7 >652 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 20 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
REACTIONS. (lb/size) 3=142/Mechanical, 2=275/0-8-0, 4=70/Mechanical
Max Horz 2=140(LC 10)
Max Uplift 3=-129(LC 10), 2=-192(LC 10), 4=8(LC 10)
Max Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 lb uplift at
joint 2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.56126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall q�
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IYIiTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T19781793
M11324
J8
MONO TRUSS
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:35 2020 Page 1
ID:kFvnsnOwY419Zh0_nM3lc6ylJ9g-35L)(!UdJH 1 vXug3XkJ4uDDQp7_XMYMIJvCzgTVz)qGY
-1-0-0 8-0-0
1 0-0 B-0-0
3x4
7-M 8-0.0
7-M
Plate Offsets (X,Y)— [2:0-3-14,0-1-8]
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(Ioc)
Udefl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
-0.14
4-7
>676
360
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
.-0.30
4-7
>310
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
0.26
4-7
>368
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical
Max Horz 2=178(LC 12)
Max Uplift 3=-174(LC 12), 2=-226(LC 12), 4=13(LC 12)
Max Grav 3=195(LC 17), 2=348(LC 1), 4=141(LC 3)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:17.5
PLATES GRIP
MT20 244/190
Weight: 26 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=59ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-7-3, Interior(1) 2-7-3 to 7-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3, 226 lb uplift at
joint 2 and 13 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not•
It
-
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type �
city
ROYALET19781794
[IyTTHFE
M11324
JA
MONO TRUSS
2
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:36 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-XHuvvgex2L10WgekHOc7mQz5eNyVHp7S8siD?xzXjGX
-1-0-0 2-4-3
1.0-0 24-3
Scale = 1:8.3
3x4 =
L 2-4-3
2.4-3
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.00 7 >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 9 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc pudins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical
Max Horz 2=73(LC 10)
Max Uplift 3=-37(LC 10), 2=-139(LC 10), 4=-4(LC 7)
Max Grav 3=50(LC 15), 2=150(LC 1). 4=37(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.56126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall A �
building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and Bost Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type I
oty
Ply
THE ROYALE
T19781795
M11324
JB
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:36 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-XHuvvgex2L1 OWgekHOc7mOz10Nm?Hp7S8siD?xzXjGX
-1-2-5 5-5-11
1-2-5 5-5-11
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.38
TCDL
7.0
Lumber DOL
1.25
BC 0.89
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical
Max Horz 2=114(LC 10) '
Max Uplift 3=-109(LC 10), 2=-206(LC 10), 4=-6(LC 10)
Max Grav 3=127(LC 15), 2=269(LC 1), 4=90(LC 3)
FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale=1:12.5
DEFL. in (loc) I/deft Ud PLATES GRIP
Vert(LL) 0.10 4-7 >646 360 MT20 244/190
Vert(CT) -0.07 4-7 >898 240
Horz(CT) -0.00 3 n/a n/a
Weight: 19 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corri zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at
joint 2 and 6 lb uplift at joint 4.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. VRegan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MtTEK REFERENCE PAGE M11.7473 rev. f0/0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�e
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T19781796
M11324
JC
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:37 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-7USH6Afape9F7_Dwrk7MIeVGNnJvOGNbNWSmXNzXjGW
1-0-0 1-1-4
LOADING (psf)
SPACING-
2-0-0
CSI.
TOLL
20.0
Plate Grip DOL
1.25
TC 0.18
TCDL
7.0
Lumber DOL
1.25
BC 0.02
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017rrP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=11/Mechanical, 2=119/0-8-0, 4=4/Mechanical
Max Horz 2=50(LC 10)
Max Uplift 3=-6(LC 7), 2=138(LC 10)
Max Grav 3=14(LC 15), 2=119(LC 1), 4=14(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:6.2
3x4 =
1-1-4
1-1-4
DEFL. in (loc) I/deft Ud PLATES GRIP
Vert(LL) -0.00 5 >999 360 MT20 244/190
Vert(CT) -0.00 5 >999 240
Horz(CT) 0.00 4 n/a nla
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.56126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd, Tampa FL 33610
Date:
March 24,2020
® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
,I
` Design valid for use only with MITekS connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPN Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
CityPly
THE ROYALE
T19781797
M11324
KJ5
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
-1-5-0
3x4 =
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:54:38 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-TgOgKWgCayH618o6PRebrr2OYBbJljclbABK4pzXjGV
3-11-0 7-0-2 ,
2.83 12
Scale=1:15.7
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) 0.09 4-7 >923 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.26
Vert(CT) -0.15 4-7 >563 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanical
Max Horz 2=109(LC 8)
Max Uplift 3=-174(LC 8), 2=-191(LC 8)
Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-3=-95(F=-20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=-8)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified.
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
® WARNING - Verify desrgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall pat
building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safefylnrormadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610
Job
Truss
Truss Type
0ty �
Ply
THE ROYALE
C
T19781798
M11324
KJ8
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
i0.=t1
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 2412:64:39 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHNlz89gN3bblbyjU50uqqxtcGzXIGU
7-2-7
3x4 = 3x4 =
7-2-7
3-10-5 0-2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) 0.08 6-9 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.25
Vert(CT) -0.10 6-9 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.35
Horz(CT) 0.01 5 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 44 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 9-10-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=90/Mechanical, 2=46510-11-5, 5=409/Mechanical
Max Horz 2=178(LC 8)
Max Uplift 4=-91(LC 8), 2=332(LC 8), 5=-223(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=875/541
BOT CHORD 2-6=535/842, 5-6=-535/842
WEBS 3-6=1/287, 3-5=923/587
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 lb uplift at joint
2 and 223 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at
2-11-0, 38 lb down and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106 lb up at 5-8-15, and 42 lb down
and 145 lb up at 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 lb up at 2-11-0, 31 lb up at 2-11-0, 11 lb
This item has been
down and 31 lb up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb
up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
electronically Signed and
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
sealed by ORegan, Philip, PE
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
document are not considered
Vert: 14=-54, 5-7=-20
signed and sealed and the
Concentrated Loads (lb)
signature must be verified
Vert: 10=80(F=40, B=40) 11=-5(F=-3, B=-3) 12=-83(F=-42, B=42) 13=14(F=7, B=7) 14=-21(F=-11, B=-11) 15=-50(F=-25,
on any electronic copies.
B=25)
Philip J. O'Regan PE No.68126
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
I ® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
111 Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component. not �A
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall -'��•
building design. Bracing indicated is to prevent buckling of individual truss web aridfor chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Salefy /nformadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE ROYALE
T19781799
M11324
KJA
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:64:39 2020 Page 1
ID:_kriGCA6bx7j2Syl HDXFw7ye3KX-xsa2XsggKGPzNHNIz89gN3bbNbzyUAsuqqxtcGzXjGU
-1-2-9 6-0-4 i
1-2.g 6.0-4
Scale=1:13.6
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) 0.04
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) 0.07
4-7 >974 240
BCLL 0.0
Rep Stress Incr NO
WEI 0.00
Horz(CT) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 20 Ib FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical
Max Horz 2=97(LC 8)
Max Uplift 3=-129(LC 8), 2=-150(LC 8)
Max Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3 and 150 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-3=-81(F=-14, B=-14), 5=0(F=10, B=10)-to-4=-30(F=-5, B=5)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
®WARNING . Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall my
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
I always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erecUon and bracing of trusses and truss systems, see ANSUTP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
THE ROYALE
T19781800
M11324
KJB
MONO TRUSS
�Oty JPly
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:40 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-Q280IChS5ZXq_RyVWsg3wG7oh?KKDd623UgR8izxiGT
-1-2-9 4-11-9
1-2-9 4-11-9
Scale = 1:11.7
3x4 =
4-11-9
4-11-9
LOADING (psi)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) Ildefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL) -0.02
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.10
Vert(CT) -0.03
4-7 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-11-9 oc puffins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=95/Mechanical, 2=148/0-9-11, 4=46/Mechanical
Max Horz 2=75(LC 8)
Max Uplift 3=-84(LC 8), 2=-136(LC 8)
Max Grav 3=95(LC 1), 2=148(LC 1), 4=77(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plo
Vert: 2=0(F=27, B=27)-to-3=-67(F=-7, B=-7), 5=0(F=10, B=10)-to-4=-25(F=-2, B=-2)
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE.
i� Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall'
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPli Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE ROYALE
T19781801
M11324
MV2
VALLEY
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
2-0-0
3x4
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:64:412020 Page 1
ID:_knGCA6bx7j2Syl HDXFw7ye3KX-uFioyXl4stfhcbXh4ZBITUg_ROhoy4MBl8Q_h8zXJGS
4.00 12
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
2 n/a Na
BCDL 10.0
Code FBC2017frP12014
Matrix-P
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=41/2-0-0. 2=3012-0-0, 3=11/2-0-0
Max Harz 1=21(LC 10)
Max Uplift 1=-20(LC 10), 2=-30(LC 10)
Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC
3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
7 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1.7473 rev. f010312015 BEFORE USE.
Design valid for use only with WWI) connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bmdng Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety In/oration available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T19781802
M11324
MV4
VALLEY
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.37
TCDL
7.0
Lumber DOL
1.25
BC 0.17
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017(rP12014
Matrix-P
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3
WEBS
2x4 SP No.3
REACTIONS.
(lb/size) 1=109/4-0-0, 3=109/4-0-0
Max Horz 1=56(LC 10)
Max Uplift 1=-54(LC 10), 3=72(LC 10)
Max Grav 1=112(LC 15). 3=117(LC 15)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
4-0-0
8.130 s Mar 112018 MiTek Industries, Inc. Tue Mar 24 12:54:41 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-uFioyXt4stfhcbXh4ZBITUgvHOPJy4MB180_h6zxGS
Scale = 1:9.4
3x4 11
DEFL. in (loc) I/defi Ud PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(CT) n/a n/a 999
Horz(CT) 0.00 n/a n/a
Weight: 12 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at
joint 3.
This item has been
electronically signed and
sealed by ORegan, Philip, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Philip J. O'Regan PE No.68126
MiTek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bradng MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
Ole
For 4 x 2 orientation, locate
plates 0- yi6" from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
' Plate location details available in MiTek 20120
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
ell, by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIITP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
1 2 3
TOP CHORDS
WEBS c 4
O= O
O eve c5 U
a
a
H c'-e c6a ce-6 00
BOTTOM CHORDS
8 7 6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MiTek
�
MiTek Engineering Reference Sheet: MII-7473 rev. 10103/2015
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses. .
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSIrrPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pur ins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient
20. Design assumes manufacture in accordance with
ANSIfrPI 1 Quality Criteria.