HomeMy WebLinkAboutConstruction PlansGENERAL NOTES-, DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. ACI318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. ALUMINUM FBC 2017 CH. 20 TABLE 2002.4 DESIGN NOTES: ALLOWABLE DESIGN PRESSURES UTILIZED IN THIS DOCUMENT HAVE BEEN CALCULATED PER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017) & ASCE 7-10 USING ALLOWABLE STRESS DESIGN METHODOLOGY WITH THE CRITERIA AS OUTLINED HEREIN. THE CONTRACTOR SHALL CONTACT THE AUTHORITY HAVING JURISDICTION TO ENSURE APPROPRIATE CRITERIA TO BE USED BEFORE CONSTRUCTION BEGINS. THE SYSTEM HAS NOT BEEN DESIGNED TO WITHSTAND CONCETRATED LOADS FROM HUMAN ACTIVITY. GENERAL NOTES: 1. THIS DOCUMENT SHALL -NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF CRAIG E. GUNDERSON, P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 2. THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). STRUCTURE SHALL BE FABRICATED IN ACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 3. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 4. THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 5. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 6. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT. 7. ALL FASTENERS TO BE #12 SAE GRADE 2 OR STAINLESS STEEL 304 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM -PLATED OR OTHERWISE CORROSION -RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 8. FOR ALUMINUM MEMBERS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN. SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 9. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 10. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON -CRACKED CONCRETE ONLY. 11. WOOD HOST STRUCTURE & ALL WOOD MEMBERS SHALL BE "SOUTHERN YELLOW PINE" G=0.55 OR GREATER DENSITY. 12. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 13. ALL ALUMINUM SHALL BE 6005-T5 ALLOY AND TEMPER UNLESS NOTED OTHERWISE. 14. ALL STEEL ANGLES SHALL BE ASTM A1011 OR A653 GRADE 50 (Fy=50 KSI, Fu=65 KSI) OR BETTER. 15. ALL CONCRETE AND EPDXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 16. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 17. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 18. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. SYSTEM NOTES: PERGOLA SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATION ISSUED BY RENAISSANCE PATIO. SYSTEM NOTES: 1. REFER TO AFOREMENTIONED MANUFACTURER ISSUED ASSEMBLY MANUAL FOR ALL CONNECTION DETAILS THAT ARE NOT ILLUSTRATED HEREIN. �- - ST. Lucie County, Permitting o o c =Z:):Wco oLLI o : Q z- U ;�'�> z° O ////1111111)111\��\ AN w 81-011 KP 1x2 2x2 O o0 � X O IL N = 2X2X.050 EDGE BEAM 8'-01 71-611 7'-0" II 1-0 O/H n I II I n I n I N II I= m m I I 10 I —i m Z L/' D I I I N Cmi N N n 10 D n r p I p z n „ w i= z Q II O , - I m III � IT N NJ OII L Ln O IN N m ~' D � i� Oz z z o 10 D O I I --n rm— Z m M N i m Ln G) O N II I �_ n I 2X2X.050 EDGE BEAM -o I I N ' ,A X 00 n � O = 2x2 D Z KP 1x2 I-- 8'-0" G E. ��NpF'%.,, s% �. �Q�, • ��CENg� . � , co v CONTRACTOR: No. 60102 o ALL STAR SUNROOMS FLORIDA ENGINEERING LLC m o o z _ z z v UNIT 101 '. STATE OF44/ N > 4161 TAM TRAIL - . � PORT CHARLOTTE, FLORIDA 33952�R!° �C��,,�` co m � 0 PROJECTADDRESS: (941) 391-5980 w www.flengineeringlic.com N ROGACKI D o 6011 PAPAYA DR raigrson, P.E. #60102 N m FT PIERCE FL PROJECT NO. 2021311 CACERT.#30782 DATE: 08/03/2020 w POST o � 2X3 DJ w 0 N 2X3 DJ = = m D rn _ � � m - o� m D � � � POST 0 Ql W X N � x 2 N mD -v m N W D ZxZ rn � rn � w POST S� 1 STRUCTURAL INSULATED PANEL PER SEPERATE CERTIFICATION, TYP. RECEIVING CHANNEL WITH #12 SELF DRILLING SCREW @ 8" O.C. 1" FROM ENDS TOP & BOTTOM OR EITHER SIDE WITH SCREW THROUGH ENTIRE PANEL, TYP. WOOD FASCIA 1 HOSTCONNECTION 6 SCALE: N. T. S DETAIL SLIDE BASE PLATE COVER OVER POST AND BASE PLATE 6 POST EMBEDMENT 6 SCALE: N. T. S DETAIL TO BE USED WITH ALL FREESTANDING STRUCTURES MAY BE USED FOR ATTACHED STRUCTURES AT CONTRACTOR DISCRETION HOST STRUCTU RE WITH BUILT-IN FASCIA (BY OTHERS), TYP. (1) 1/4" DIA. WOOD SCREW SPACED 1" MIN., WITYH 1.S" THREAD PENETRATION MIN. & 1" EDGE DISTANCE @ EVERY 12" O.C, TYP. SLIDE BASE PLATE COVER OVER POST AND BASE PLATE i REBAR 12" LONG 1RU POST, TYP. (6) CONCRETE ANCHOF STRUCTURAL INSULATED PANEL PER SEPERATE CERTIFICATION, TYP. (4) #14 SELF DRILLING SCREW PER SIDE, TYP. POST 5 ANCHOR CONNECTION 6 SCALE: N. T. S DETAIL TO BE USED WITH HOST ATTACHE D STRUCTURES ONLY RECEIVING CHANNEL WITH #12 SELF DRILLING SCREW @ 8" O.C. 1" FROM ENDS TOP & BOTTOM OR EITHER SIDE WITH SCREW THROUGH ENTIRE PANEL, TYP. D (1) 1/4" DIA. TAPCON WITH D a 2.5" EMBEDMENT INTO 3KSI �t' OR GROUT FILLED CELLS WITH 5" MIN SPACING & 6" EDGE zr_DISTANCE @ 24" O.C, TYP. D .4 EXISTING D CONCRETE OR CBS p WALL, TYP. H OST CO N N ECTI O N 2 (CONCRETE OR BLOCK) 6 SCALE: N. T. S DETAIL ATTACH TO CARRY BEAM W/#12 SELF -DRILLING SCREW W/ 1" OD WASHER @6" O.C, TYP. FA (4) #14 SELF DRILLING SCREW PER SIDE, TYP. STRUCTURAL INSULATED PANEL PER SEPERATE CERTIFICATION, TYP. 4 POST CONNECTION 6 SCALE: N. T. S DETAIL . .. .:. . . .. . . (2) #14 SELF -DRILLING SCREW PER SIDE, TYP. (4) 414 SELF -DRILLING SCREW PER SIDE, TYP. (3 WASF 0 \\\\0��1111111�,'////// Z•coo O O_ J ZD =C> :W LIJ Q o. z_ y' Z �o ATTACH TO CARRY BEAM W/ #12 SELF -DRILLING SCREW W/ 1" OD WASHER @6" O.C, TYP. 1&3 3 POST CONNECTION 6 SCALE: N. T. S DETAIL HEAVY HEADER & HEAVY POST CONNECTION (ALTERNATE, ONLY WHEN SPECIFIED) N 0 0 ui a: 0 1 a) c� w POST BASE ANCHOR TIE - DOWN SCHEDULES: (FOR USE WITH HOST ATTACHED SYSTEM HOST MOUNTED SYSTEM (REFER TO DETAIL 5/6) WIND SPEED (EXPOSURES B & C) ALL PROJECTION -BEAM SPAN, ALL MAIN BEAM SPAN 120 MPH ANCHOR TYPE #1 ANCHOR TYPE #2 150 MPH ANCHOR TYPE #1 ANCHOR TYPE #2 170 MPH ANCHOR TYPE #1 ANCHOR TYPE #2 ANCHOR TYPES: (6) 1/4" DIA ITW TAPCON, 1/4" DIA. SAE GRADE WASHER, 1.75" EMBEDMENT, ANCHOR TYPE #1 2.5" SPACING, 3" MIN. EDGE DISTANCE INTO 3KS1 MIN. CONCRETE (6) 1/4" DIA BLUE TAP ANCHOR WITH 2.1" EMBEDMENT, INTO 3KSI MIN. ANCHOR TYPE #2 CONCRETE 2.5" SPACING, 3" MIN. EDGE DISTANCE 1" 2 5" 38 3 ANCHOR SCHEDULE "_') SCALE: N. T. S 1" 2 4 ANCHORS TO BASE PLATE g SCALE: N. T. S ,_FOOTER_, WIDTH 00 ®° 0� U- REBAR NOT SHOWN FOR CLARITY PLAN VIEW (2) #5 LONGITUDINAL REBAR AT BOTTOM REBAR AT TOP QUANTITY EACH WAY PER SCHEDULE cc = 00 0� U- FOOTER I �REBAR AT BOTTOM WIDTH --1 QUANTITY EACH WAY PER SCHEDULE 1 TYPICAL FREESTANDING FOOTING g SCALE: N. T. S TYPICAL HOST ETAIL 5/6 #4 REBAR @ 6" O.C. DOWELED INTO EXIST. SLAB MIN 4" SET IN EPDXY, TYP. SLAB :LL COMPACTED SOIL (BY OTHERS) 2 ATTACHED STRIP FOOTING "_') SCALE: N. T. S FOOTER REINFORCEMENT FOOTER WIDTH NUMBER OF #5 REBAR EACH WAY TOP BOTTOM 29" 3 3 35" 3 3 40" 3 3 FOOTING SCHEDULE NOTES: 1. PROVIDES THE REQUIRED FOOTER REINFORCEMENT FOR THE RESPECTIVE FOOTER SIZE. 2. REQUIRED REINFORCEMENT IS BASED ON UP TO 30" DEEP FOOTERS. 3. SEE DETAIL 1/7 FOR DEFINITION OF FOOTER WIDTH & DEPTH. 4. ALL REINFORCEMENT SHALL HAVE A MINIMUM CLEAR COVER OF 3". 5. ALL REINFORCEMENT SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A615, GRADE 60 (U.N.O.), FREE FROM OIL, LOOSE SCALE AND LOOSE RUST; AND BENT, LAPPED, PLACED, SUPPORTED AND FASTENED ACCORDING TO THE "ACI DETAILING MANUAL" AND ACI 318. ALL STEEL SHALL BE SECURELY HELD IN PLACE DURING POURING OF CONCRETE. IF REQUIRED, ADDITIONAL BARS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR TO FURNISH SUPPORT FOR ALL BARS •�' / 'uj LL 0 co 0 o Lu d/ o 0 w ro Q = 10uj /��/�IIIIIIIII00\ 38 rcoo 0.090 HOST ATTACHED POST 7 38 Flo M HEAVY POST (Freestanding Structures Only, Unless Specified) 24 HEADER BEAM N 0.080 31' POST CAP HOST ATTACHED 2i. HEAVY HEADER BEAM (Alternate, Only When Specified) NON-STRUCTURAL PARTS (OPTIONAL) I ? GUTTER DROP POST BASE COVER DOWNSPOUT STRAP HEADER END CAP STRUCTURAL PARTS 36„ .-lo M 1 16„ iv 0.080 3 8' POST CAP FREESTANDING GUTTER CAP LEFT 61„ 2 BASE PLATE HEADER INTERIOR CLIP ROOF 3" RECEIVING CHANNEL �Im 0.125 F� HEADER HD INTERIOR CLIP GUTTER JOINER ��u STRUCTURAL INSULATED PANEL GUTTER CAP RIGHT 61 a,lm 0.065 M GUTTER N Co.; . ! o cm CoZz O O ( O -mow o =C� CO �: - o N z tj 0 O 00CD W