Product Approval
USER: Publi[ User
Product Aiaproval Menu > Product or 2plication Search > Ari]lication List > Application Detail
FL#
Application Type
Code Version
Application Status
Comments
Archived
Product: Manufacturer
Address/Phone/Email
Authorized Signatilre
Technical Representative
Address/Phone/Email
Qual'lty Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL16048-R6
Revision
2017
Approved
Tri-Built Materials Group, LLC
PO BOx 70
Rutherford, NJ 07070
(800) 516-1485
david,ruiz@tribuiltmg,com
David Riiiz
david .ruiz@tribui ltmg .com
Davld Rul2
250 Route 17 North
East Rutherford, NJ O7o73
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
ROofing
Underlayments
Evaluat:ion Report from a Florida Registered Architect or a Licensed Florida
Professlonal Engineer
Evaluation Report -Hardcopy Received
Florida Englnecr or Arc.hltect Namt: wlio dcveloF]ed tlie Robert Nlemlnen
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificat:e of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certifled By
PE-59166
UL LLC
06/29/2023
John W. Knezevich, PE
' Valldat.Ion Checklist -Hardcopy Recelved
Standard
ASTM D1970
ASTM G155
FM 4474
FRSAITRI April 2012 (04-12)
UL 1897
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtFpmdYiNDwrvipmtAnR8jv9FiYHTk4FLCxcqvtRhfvMw%3d%3d 1/2
8/26/2020
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Florida Building Code Online
Method 1 option D
09/25/2017
10/01/2017
10/03/2017
12/12/2017
Summary of Products
FL#Model, Number or Name Description
16048.1 TRI-BUILT Roof underlayments Self-adhering, modified bitumen roof underlayments
Limits af Use Installation Instructions
Approved for use in HVHZ: No FL16048 R6 11 2017 09 FINAL ER TRI-
Approved for use outs ide HVHZ: Yes BUILT UNDERLAYMENTS FL16048-R6. 2d£
Impact F`esistant: N/A Verlfled By: Robert Nlemlnen PE-59166
I)es[gn Pressure: +N/A/-150 Created by Independent Third Party: Yes
Othel`: 1.) The deslgn pressure noted herein pertains to use of Evaluation Reports
foam-on tile systems overtop the self-adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI-
for one partlcular appllcat I.on. See ER Sectlon 5.6.4 for details.BUILT UNDERLAYMENTS FL16048-R6. f
2.) Refer to ER Section 5 for other Umlts of Use,Created by Independent Third Party: Yes
EEE
Contact Us : : 2601 Blair Stoiie Road, li]llahassee FL 32399 Phone: 850-487-1824
The State Of Florida is an AA/EEO employer, £gpy[ight 2007-2013 State Of Florida. : : Ed}[agr Statement : : Accessibility Statement : : Refund Statement
Under Florida few, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronie
mall tci this entity. Instead, contact the office by phone or by traditlonal mail. It you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective october 1, 2012, licensees licensed under Chapter 455, FS. must pro\/lde the Department with an emaH address lf they have one. The emails
provided may be used for official communlcatlon \^/lth the llcensee. tiowever email addresses are pubwc record. If you do not wlsh to su|)Dry a personal address, phase
provide the Department with an eman address which can be made available to the piiblic. To determine if you are a licensee iinder Chapter 455, F,S„ please cllck b£[s..
Product Appro`/al Accepts:
EE RE EiH BEE E
Credit CardSate
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVxctwtDqtFF'mdYiNDwrvipmtAnR8jv9FiYHTk4FLCxcqvtRhfvMw%3d%3d 2/2
(\:h_:;TRINITY
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
TRl-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
Evaluation Report A42960.10.12-R6
FL16048-R6
Date of lssuance: 10/25/2012
Revision 6: 09/25/2017
ScOpE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DEscRlpTloN: TRl-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CoNTINUED CoMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P,E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity| ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity| ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INspECTloN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report cons.ists of pages 1 through 6.
Prepared by:
Robert I.M. Nieminen, P.E.
Flor.Ida Flegistration No. 59166, Flor;da DCA ANE1983
.+.ssr.N.Nf##`gr#f-:.-
'' tr =
i-..3j;ii£.;i;,;iifii;j`:::`;?=
The facsimlle seal appearln8 was authorlzed bv F`obert Niemlnen,
P.E. cin 09/25/2017. This does not serve as an electronlcally slBned
document.
CEBTIFICATION 01: INDEPENDENCE :
1. Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity| ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates,
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4, Robert Nieminen, P,E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinfty|ERD nor Robert Nieminen, P.E. are, in any way, the Des.i8ner of Reccird for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
(\::;i-`!lN,TY
ROOFING COMPONENT EVALUATION:
1. ScOpE:
Product category: Roofing
Sub-Category: U n derlayment
Compliance Statement: TRl-BUILT Roof Underlayments, as produced by TRl-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6th Edition (2017) I=lorlda Building Code through testing
in accordance with the following Standards. Compliance is subj.ect to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
ls04.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1,1507.2.9.2
1507.3.3
3. REFERENCES:
Erty
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
lJL, LLC. (QUA9625)
UL, LLC. (QUA9625)
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Qua lity Control
Standard
FM 4474
uL 1897
ASTM G155
ASTM D1970
FRSAnRi April 2012 (04-12)
Reference
S40540.02.13-1
S40540.11.13
S40540.03.14
S44870.04.14-2
S44870.04.14-3
S44870.04.14-1
S44870.04.14-4
S43530.02.14-1-RI
S43530.05.14
S40540.10.14
SC7645.02.15
SC8520.04.15
SC14045.05.17-RI
Multiple-Listing R16814
Service Confirmation
Date
on.|T8|2fjr3
11/19/2013
ua|2:6|2:OL4
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
ash:]i2fIT5
06iovn:Or]
12/10/2015
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built s/A HT TU underlayment is a self-adhering, non-woven polyester fabric surfaced, SBs modified
bitumen roof underlayment; meets ASTM D1970 and FRSAnRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design gLlidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHzj.urisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterlor Research and I)eslgn, LLC.
Ce rtificate of Authorization #9503 6" EDITloN (2017) FBC NON-HVHZ EVALUATION
TRl-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12-R6
FL16048-R6
Revision 6: 09/25/2017
Page 2 of 6
:#:,N,TY
5.4 TRl-BUILT Roof underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
Allctwable Roof Covers:
TABLE 1: ROOF CdvER0rmoNs
-
underlayment AsphaltShingles Nail.On Tile Foam-On Tile Metal Wood Shakes&Shingles Slate
Tri-Built Sand-R SA ShingleUnderlavment Yes No No No Yes Yes
Tri-Bu.ilt S/A HT TU Yes Yes
Yes Yes Yes YesUnderlaymentSee 5.5.1
Tri-Built Smooth HT S/AUnderlayment Yes No No Yes Yes Yes
5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE iA:ALLOWABLE`TILEAbHESIVE/'UNDERLAtM'ENl. CO'MBINATI0NS£ \
Adhesive Florida Product Approva I Underlayments
lcp Adhesives Polyset® AH-160 FL6332 Tri-Built S/A HT TU Underlayment
Dow TileBondtM FL22525 Tri-Built S/A HT TU Underlayment
5.6 Allowable substrates:
5.6,1 Direct-Bond to Deck:
5.6.2
Trinouilt Sand-R SA Shingle Underlayment, Tritoullt S/A HT TU Underiayment or Tri-Built Smooth HT S/A
underlayment applied to:
> Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not rec|uired over plywood, OSB or Southern Yellow Pine substrates, TRl-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRl-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or
OSB prior to installation of the self-adhering underlayment.
Bond-to-Insulation:
TriDuilt Sand-R SA Shingle Under]ayment, TriBuilt S/A HT TU Underlayment or TriBuilt Smooth HT S/A
underlayment applied to:
> Dens Deck prime; SECUROCK Gypsum-FiberRoof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems ITri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterlor Research and Deslgn, LLC.
Certificate of A uthorization sO503 6" EDITION (2017) FBC NON-HVHZ EVALUATloN
TRI-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12-R6
FL16048-R6
Revision 6: 09/25/2017
Page 3 of 6
:\\``:Jiri,Nltt
ERD
5.6.3 Bond to Mechanicallv Attached Base Laver:
Trireuilt Sand-R SA Shingle Underlayment, Trirouilt S/A HT TU Underlayment or Trirauilt Smooth HT S/A
Underlayment applied to:
> AS" D226, Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems ITri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSAnRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlavment Systems in Foam-On THe Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foamron tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table lA or
FBC 1609 for determination of design wind pressures.
#1 Maximum Desifzn pressure = 45.ODsf:
Deck: Min. 15/32inch plywood to meet project requirements to satisfaction of Authority
HavingJurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built s/A HTTU underlayment, self-adhered.
#2 Maximum Design pressure = rd7.5 Dsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built s/A HTTU underlayment, self-adhered.
#3 Maximum Design pressure = -150.0 pst:
Deck: Min.15/32-inch APA-rated BCx plywood (may be installed c-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deckpreparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projectictns shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Ti.i-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end-laps.
#4 Maximum Design pressure = -60.0 Dsf:
Deck: Min.19/32-inch pl\^^/ood to meet project requirements to satisfaction of Authority
HavingJurisdiction.
Base sheet: Soprema sopra-G or Modified sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built s/A HT Tu underlavment, self-adhered.
Exterior Research and Design, LLC.
Ce rtifi¢ate Of Author.ttation ro5o3 6TH ED|T|oN (2ol7) FBC NON-HVHZ EVALUATION
TRl-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12-R6
FL16048-R6
Revision 6: 09/25/2017
Page 4 of 6
(:\`!`i:EINITY
5.6.4.1 For mechanically attached Base sheet, the maximum design pressure forthe selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table lA.
Altematively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANsl/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Rooflng
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 EXDosure Limitations:
TriBuilt SandR SA Shingle Underlayment or TrLBuilt Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
TriBuilt S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation,
5.8 Tile slippage Limitations (TAS 103 per FRSAITRI April 2012 (04-12)):
When loading roof tiles on the underlayment in directrdeck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2:'TIIESLIPPAGELIMITATloNSFdRDI R Err-DECK\tiLE I NSTALIAT'o NS,
Underlayment Tile Profile Staging Method MaximumSlope
Tri-Bu.ilt S/A HT TUUnderlayment
Flat Max. 10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Lugged
Max. 10.tileshallbeinvertonslostack (bottom 2-tile stacked,followedby8tileshighpe,asshownbelow)
6:12
{,5££ i•:\`„%, .&agi,`-t!,,*xp
_ae t `'f?,(`
"\*i:` ,l,`tr\,,,;,,,:f?¢,\;''i=;fz,,`,`-`t'L,"``{` H|
i-I,`,i.'i.:I,';,,,';i I ,,`,,
¥
i A,..i-,,??=,..,#£
•.., .%,
`
ac #1^`.'
`, ,-!,-,
Exterior Research and Design, LLC,
Ce rtificate Of Authorization ro5o3 6" EDITloN (2017) FBC NON-HVHZ EVALUATION
TRl-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10,lz.R6
FL16048-R6
Revision 6: 09/25/2017
Page 5 of 6
(:-\`ji:RINITY
6. I NSTALLATION :
6.1 TRl-BUILT Roof Underlayments shall be installed in accordance with TRl-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels, and check for prc)truding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built sand-R SA shingle llnderlavment, Tri-Built s/A HT TU underlavment or Tri-Built smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile apD`ications..
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge, Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, con figured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRl-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
6.3.3
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths, Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
Tile APE]lications ITri-Built S/A HT TLJ Underlavment oniv):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foamron tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
stagln8.
7. BUILDING PERMIT REQUIREMENTS:
As rec|uired by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PIANTS:
Gulf port, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC -QUA9625; (314) 578-3406; k.chancellor@us.ul.com
-END 0F EVALUATION REPORT -
Exterior Research and Design, LLC.
Ce rtificate of A uthorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATloN
TRl-Bull.T Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12.R6
FL16048-R6
Revision 6: 09/25/2017
Page 6 of 6