HomeMy WebLinkAboutProduct Approval MIAMI- MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES R Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany-NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke,modify, or suspend the use of such product or material within
their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade
County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Concrete Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials,.use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-1020.03 and consists of pages 1 through 45.
The submitted documentation was reviewed by Jorge L.Acebo.
MIAMI•DADE COUNTY
NOA Nn.: 18-0919-13-
Fxniration Dati— 11/06173
Approval Date: 11/01/1 R
Page 1 of 45
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Concrete
Maximum Design Pressure: -495 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
GAFGLAS®Ply 4 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet
(1 meter)Wide reinforced with fiberglass mat.
Tri-Ply®Ply 4 Ply Sheet 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet
(1 meter)Wide reinforced with a fiberglass mat.
GAFGLAS®F1exPly 6 39.37" ASTM D2178 Smooth surfaced asphaltic ply sheet
(1 meter)Wide reinforced with fiberglass mat.
GAFGLAS®#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet
(1 meter)Wide reinforced with fiberglass mat.
Tri-Ply®#75 Base Sheet 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet
(1 meter)Wide reinforced with a fiberglass mat.
GAFGLAS®#80 Ultima"'Base 39.37' ASTM D4601 Smooth asphaltic base or base/ply sheet
Sheet (1 meter)Wide reinforced with fiberglass mat.
GAFGLAS®Stratavent® 39.37' ASTM D4897 Smooth surfaced asphaltic perforated
Perforated Venting Base Sheet (1 meter)Wide venting base sheet reinforced with
fiberglass mat.
GAFGLAS®Stratavent®Nailable 39.37' ASTM D4897 Smooth surfaced asphaltic nailable
Venting Base Sheet (1 meter)Wide venting base sheet reinforced with
fiberglass mat. Bottom side surfaced
with granules.
GAFGLAS®Mineral-Surfaced 39.37' ASTM D3909 Granule surfaced asphaltic cap sheet
Cap Sheet (1 meter)Wide reinforced with fiberglass mat.
Tri-Ply®BUR Granule Cap Sheet 39.37' ASTM D3909 Granule surfaced asphaltic cap sheet
(1 meter)Wide reinforced with a fiberglass mat.
GAFGLAS®EnergyCapT' 39.37' ASTM D3909 Granule surfaced asphaltic cap sheet
Mineral-Surfaced Cap Sheet (1 meter)Wide reinforced with fiberglass mat. Cap
sheet is factory coated with
EnergyCote'.
u eros moot 7' 1 ASTM D6163 Smooth surfaced torch applied SBS
meter)Wide base or ply sheet reinforced with a
fiberglass mat.
Ru eros mooth 39.37" (1 ASTM D6164 Smoothsurfaced torch applied
meter)Wide base or ply sheet reinforced with a
polyester mat.
Ruberoid®HW Granule 39.37" (1 ASTM D6164 Granule surfaced torch applied SBS cap
meter)Wide sheet reinforced with a polyester mat.
NOA No.: 18-0919.13
MIAMI•DADe Cou1VTY Expiration Date: 11/06/23
,Approval Date: 11/01/1
Page 2 of 45
Test Product
Product Dimensions Specification Description
Ruberoid®HW Granule FR 39.37" (1 ASTM D6164 Fire retardant granule surfaced heat-
meter)Wide welded SBS cap sheet reinforced with a
polyester mat.
Ruberoid®HW Plus Granule 39.37' (1 ASTM D6164 Granule surfaced torch applied SBS cap
meter)Wide sheet reinforced with a polyester mat.
Ruberoid'HW Plus Granule FR 39.37' ASTM D6164 Fire retar ant granule sur ace torch
(1 meter)Wide applied sheet reinforced with a
pp SBS cap
polyester mat.
Ru eroi EnergyCap W Plus 39.37' ASTM D6164 Fire retardant granule surfaced heat-
Granule FR (1 meter)Wide welded SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory
coated with EnergyCote'
Ruberoid®Torch Smooth 39.37' ASTM D6222 Smooth surfaced torch applied APP
(1 meter)Wide base or ply sheet reinforced with a
polyester mat.
Tri-Ply®APP Smooth Membrane 39.37' ASTM D6222 Smooth surfaced torch applied APP cap,
(1 meter)Wide base or ply sheet reinforced with a
polyester mat.
Ruberoid®Torch 39.37" ASTM D6222 Granule surfaced torch applied APP cap
Granule (1 meter)Wide sheet reinforced with a polyester mat.
Tri-Ply®APP Granule Cap Sheet 39.37' ASTM D6222 Granule surfaced torch applied APP cap
(1 meter)Wide sheet reinforced with a polyester mat.
Ruberoid®Torch Plus Granule 39.37" ASTM D6222 Fire retardant granule surfaced torch
FR (1 meter)Wide applied APP cap sheet reinforced with a
polyester mat.
Ruberoid®EnergyCapT`'Torch 39.37' ASTM D6222 Fire retardant granule surfaced torch
Plus Granule FR (1 meter)Wide applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory
coated with EnergyCoteT"
Ruberoid® EnergyCap' 39.37" ASTM D6222 Fire retardant granule surfaced torch
Torch Granule FR (1 meter)Wide applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory
coated with EnergyCoteT"
Ruberoid®20 Smooth 39.37" ASTM D6163 SBS polymer-modified asphalt base or
(1 meter)Wide ply sheet reinforced with a fiberglass
mat.
Ruberoid®30 Granule 39.37" ASTM D6163 Granule surfaced mop applied SBS cap
(1 meter)Wide sheet reinforced with a fiberglass mat.
Ruberoid®30 Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop
(1 meter)Wide applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid®30 Plus Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop
(1 meter)Wide applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid®Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
NOA No.: 18-0919.13
MIAMI•DADE COUNTY
..., � _Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 3 of 45
Test Product
Product Dimensions Specification Description
Tri-Ply®SBS Granule Cap Sheet 39.37' ASTM D6164 Granule surfaced mop applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
Intee Flex PRF 39.37' ASTM D6164 Granule surfaced mop applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
Ruberoid®Mop Smooth 39.37' ASTM D6164 Smooth surfaced mop applied SBS base
(1 meter)Wide or ply sheet reinforced with a polyester
mat.
Ruberoid®Mop Smooth 1.5 39.37' ASTM D6164 Smooth surfaced mop applied SBS base
(1 meter)Wide or ply sheet reinforced with a polyester
mat.
Ruberoid®Mop Plus Smooth 39.37' ASTM D6164 Smooth surfaced mop applied SBS base
(1 meter)Wide or ply sheet reinforced with a polyester
mat.
Ruberoid®Mop Plus Granule 39.37' . ASTM D6164 Granule surfaced mop applied SBS cap
(1 meter)Wide sheet reinforced with a polyester mat.
Ruberoid®Mop Plus Granule FR 39.37' ASTM D6164 Fire retardant granule surfaced mop
(1 meter)Wide applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid®EnergyCap'Mop 39.37' ASTM D6164 Fire retardant granule surfaced mop
Plus Granule FR (1 meter)Wide applied SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory
coated with EnergyCote''
Ruberoid®Mop Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced mop
(1 meter)Wide applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid®EnergyCap'30 39.37" ASTM D6163 Fire retardant granule surfaced mop
Granule FR (1 meter)Wide applied SBS cap sheet reinforced with a
fiberglass mat. Cap sheet is factory
coated with EnergyCote''
Matrix' 102 SBS Membrane 3, 5 or 55 ASTM D3019 Fiber reinforced rubberized cold-applied
Adhesive gallons adhesive for modified bitumen roof
systems.
TOPCOAT® Membrane 1, 5 or 55 ASTM D6083 Water-based elastomeric coating
gallons
United Coatings'Roof Mate 5 or 55 gallons ASTM D6083 Water-based elastomeric coating
TCM Coating
TOPCOAT®MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed
to block asphalt bleed-through.
United Coatings"Roof Mate 5 or 55 gallons Proprietary Water based, low VOC primer designed
MB Plus Coating to block asphalt bleed-through.
TOPCOAT® 5 gallons ASTM D6083 Solvent-based thermoplastic rubber
Surface Seal SB sealant designed to protect and restore
aged roof surfaces and to increase roof
reflectivity.
NOA No.: 18-0919.13
MIAMI•DADE COUNTY Expiration Date: 11/06/23
_Approval Date: 11/01/18
Page 4 of 45
Test Product
Product Dimensions Specification Description
United Coatings'"` Surface Seal 5 or 55 gallons ASTM D6083 Solvent-based thermoplastic rubber
SB Roof Coating sealant designed to protect and restore
aged roof surfaces and to increase roof
reflectivity.
Flex Seal'' 5 or 55 gallons TAS 139 Solvent-based elastomeric sealant.
Matrix'307 Premium Asphalt 3, 5, 55 ASTM D41 Asphalt concrete primer used to
Primer gallons promote adhesion of all types of
asphalt-based roofing materials.
Matrix'201 Premium SBS 11 oz. Tubes ASTM D4586 Cold applied flashing cement in SBS-
Flashing Cement or 5 gallons ASTM D3409 modified bitumen asphalt roof systems.
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA
EnergyGuard7 Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuarr Tapered Polyiso Polyisocyanurate foam insulation GAF
Insulation
EnergyGuard'RA Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard'RH Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard'RN Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuardd'RA Composite Polyiso Polyisocyanurate foam insulation with GAF
Insulation high density fiberboard or permalite
EnergyGuard"Perlite Roof Insulation Perlite insulation board. GAF
EnergyGuard'"Perlite Recover Board Perlite recover board GAF
DensDeck®Roof Board Gypsum board. Georgia-Pacific Gypsum LLC
IDensDeck®Prime®Roof Board Gypsum board. Georgia-Pacific Gypsum LLC
Structodek®High Density Fiber Board High Density Fiber Board Blue Ridge Fiber Board,Inc.
Roof Insulation
SECUROCK®Gypsum-Fiber Roof Gypsum board. United States Gypsum Corp.
Board
NOA No.: 18-0919.13
=Mlin
DECOUNTY -�� Expiration Date: 11/0 .
Approval Date: 11/01/18
^� PaLye 5 of 45
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1 Drill-Tec''#14 Fastener Truss head, self-drilling, #14 x 16" GAF
pinch point,high thread Max. Length,
fastener for use in steel, #3 Phillips
wood or concrete decks. head.
2 Drill-Tec' 3" Steel Plate Round Galvalume®steel 3" Round GAF
stress plate with
reinforcing ribs and
recessed for use with Drill-
Tec' fasteners.
3 Drill-Tec'2 in. Barbed Round galvanized steel 2" Round GAF
Plate stress plates for use with
Drill-Tec'fasteners.
4 Drill-Tec'AccuTrac®Flat A2-SS aluminized steel 3" square; GAF
Plate plate for use with Drill- .017" thick
Tec'fasteners.
5 Drill-Tec'AccuTrac® Galvalume®steel plate 3" square; GAF
Recessed Plate with recess for use with .017" thick.
Drill-Tec'fasteners.
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
FM Approvals FMRC 4470 ODOA8.AM 07/09/97
FMRC 4470 2B8A4.AM 07/02/97
FMRC 4470 3005640 11/09/00
FMRC 4470 3006845 . 10/17/00
FMRC 4470 3005175 05/23/00
FMRC 4470 3005177 05/19/00
FMRC 4470 3005640 11/09/00
FMRC 4470 3007500 06/15/00
FMRC 4470 3008178 12/27/00
FMRC 4470 3010215 03/01/01
FMRC 4470 3009788 03/28/01
FMRC 4470 3011140 08/14/01
FMRC 4470 3013788 01/10/03
FMRC 4470 3017250 04/05/04
FMRC 4470 3018578 09/14/04
FMRC 4470 3028039 09/11/06
FMRC 4470 3032811 12/11/08
FMRC 4470 3042887 11/14/11
FMRC 4470 3023458 07/18/06
FMRC 4470 3036980 08/14/09
NOA No.: 18-0919.13
CMIAMI-MADEC11W Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 6 of 45
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency/Identifier Name Report Date
FM Approvals FMRC 4470 3042905 01/10/12
FMRC 4470 3028039 09/11/06
FMRC 4470 3035864 06/03/09
FMRC 4470 3045348 05/30/12
FMRC 4470 3046328 09/13/12
FMRC 4470 3047104 08/29/13
FMRC 4470 797-10228-267 01/15/15
FMRC 4470 RR203450 12/04/15
FMRC 4470 FM Letter 04/11/13
FMRC 4470 FM Letter 09/15/15
FMRC 4470 RR213219 03/14/18
Trinity I ERD ASTM D6862 C8500SC.11.07 11/30/07
TAS 114 #01881.09.03-2 03/24/08
TAS 114 #01881.11.03-2-R1 08/21/07
TAS 114 #4483.04.97-1 06/06/97
ASTM D6222 G30250.02.10-2 02/11/10
ASTM D3909. G30250.02.10-3-R2 06/03/15
ASTM D6164 G31360.03.10 03/31/10
ASTM D6164 G33470.01.11 01/13/11
ASTM D6163 G34140.04.11-2 04/25/11
ASTM D4601 G34140.04.114-R2 06/04/15
ASTM D4897 G34140.04.11-5-R3 06/04/15
ASTM D6222 G40620.07.12-2 07/17/12
ASTM D6164 G40630.01.14-2A 01/07/14
ASTM D6164 G40630.01.14-2A-1-R1 04/10/14
ASTM D6164 G40630.01.14-2B-Rl 01/16/15
ASTM D6164 G40630.01.14-2C 01/07/14
ASTM D6163 G40630.01-14-1 01/06/14
ASTM D6164 G40630.03.14 03/06/14
ASTM D6222 G43190.03.14-1 03/06/14
ASTM D6222 G43190.03.14-2 03/06/14
ASTM D6222 G43190.05.14-R1 05/20/14
ASTM D6222 G43190.11.13-1 11/15/13
ASTM D3909 G43610.01.14 01/22/14
ASTM D6163 G46160.02.15 02/12/15
ASTM D6163 G46160.02.15-2D-1 02/09/16
ASTM D6163 G46160.03.15 03/11/15
ASTM D6163 G46160.09.14-2A 09/09/14
ASTM D6164 G46160.09.14-3A 09/09/14
ASTM D6164 G46160.09.14-3B 09/09/14
ASTM D6164 G46160.09.14-3C 09/09/14
ASTM D6164 G46160.12.14-3E 12/29/14
ASTM D6163 G6850.08.08 08/01/08
ASTM D6222 G6850.10.08 10/06/08
ASTM D6222 G6850.11.08 02/17/09
NOA No.: 18-0919.13
MIAMI•DAD,COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 7 of 45
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency/Identifier Name Report Date
Trinity I ERD ASTM D6164 G6850.08.08-R1 04/14/11
ASTM D3909 SC6870.08.14-R1 09/04/14
UL LLC UL 790 R1306 08/21/18
PRI Construction Materials TAS 139 GAF-122-02-01 05/07/06
Technologies,LLC ASTM D2178 GAF-3.14-02-01 08/23/11
ASTM D2178 GAF-315-02-01 08/23/11
ASTM C1289 GAF-369-02-01 10/22/12
ASTM C1289 GAF-464-02-01 02/06/14
ASTM D6083 GAF-498-02-01 09/16/16
ASTM D6083 GAF-499-02-01 03/12/14
ASTM D6083 GAF-500-02-01 03/12/14
Atlantic&Caribbean Roof 06-041 TAS 114-D 11/10/06
Consulting,LLC 11-051 TAS 114-D 08/11/11
12-009 TAS 114-D 04/20/12
NOA No.: 18-0919.13
MIAMI-DAD;COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 8 of 45
I
APPROVED ASSEMBLIES:
Membrane TXpe:- APP/SBS
Deck Type 3I: Concrete Decks,Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(1): Insulation adhered with approved adhesive and membranes adhered to insulation.
Vapor Retarder: oval) One or more plies of GAFGLAS®Ply 4, Tri-Ply®Pl 4 ,
GAFGL Pt `"' 6, GAFGLAS®#75 Base 1- Y'#75 Base Sheet,
GAFGLAS®4
80 Ul
tma r uberoid®20 Smooth®adhered with hot
asphalt a - bs./sq. to e ed with ASTM D-41 Asphalt Primer
atrix'M 307 Premium Asphalt Primer.
All General and System Limitations shall apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuardT°'Polyiso Insulation,EnergyGuardT"'RH Polyiso Insulation
Minimum. 1%"thick N/A N/A
Note: Base layer shall be adhered with OlyBond®at 1 gal./sq.full coverage,.OlyBond 500®or
OlyBond 500®Green-n s/d" to 1" wide ribbons spaced 12" o.c. Insulation panels listed are
minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density(See Roofing Application Standard RAS 117 for
fastening details).
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/W
DensDeck®Primp Rnaf Rnarrl SECUROCK®Gypsum-Fiber Roof Board
Minimum.l/a"thick N/A N/A
Note: Apply top layer of insulation with OlyBond®at 1 gal./sq.full coverage, OlvBond 500®or
OlyBond 500®Green in 3/4" to 1" wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment_ Tncnlatinn lictod ac Race T.a'rnr only-hall be ngpd-
-only_as base layers with a second layer of approved Top Insulation Laver installed as the final
membrane substrate.
Anchor Sheet: Two plies of GAFGLAS®#75 Base Sheet,Tri-Ply®#75 Base Sheet
(Optional) or a single ply of GAFGLAS®#80 Ultima'Base Sheet,Ruberoid®20 Smooth®,
Ruberoid®Mop Smooth,Ruberoid®Mop Smooth 1.5,Ruberoid®Mop Plus
Smooth,Ruberoid®HW 25 Smooth",Ruberoid®HW Smooth'applied in hot
asphalt full mop at 25 lbs./sq.
Base Sheet: One or more plies of Ruberoid®HW 25 Smooth'or Ruberoid®HW Smooth7
torch applied.
Ply Sheet: lies of Ruberoid® 1 11, , ,,r;,11! Smooth—
(Optional) pie .
MIAWDADE COUNTY _NOA No.: 18-0919.13
.Expiration Date: 11/06/23_
Approval Date: 11/01/18
Page 9 of 45_
Membrane: One or more plies Ruberoid®HW 25 Smooth , Ruberoid®HW Smooth'"',
Ruberoid®HW Granule' Ruberoid®HW Granule FRT' Ruberoid®HW Plus
Granule',RuberoidHW Plus Granule FR or Ruberoid EnergyCap HW Plus
Granule FRT", applied in accordance with manufacturer's instructions.
Or
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®APP Smooth Membrane,
Ruberoid®Torch Granule, Tri-Ply®APP Granule Cap Sheet,Ruberoid®Torch Plus
i Granule FR®,Ruberoid®EnergyCapT".Torch Granule FR or Ruberoid®
EnergyCapT'Torch Plus Granule FRT"'applied in accordance with manufacturer's
instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions.All coatings must be listed within a current NOA.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of
proved asphalt at 601bs./sq.
2. GAF ®Mineral-Surfaced Cap Sheet, Tri-Ply®BUR Granule eet®or
GAFGLAS rgyCap"Mineral-Surfaced Cap Sheet'"a in a full mopping
of approved aspha lied within the EVT range a rate of 20-40 lbs./sq.
3. TOPCOAT®Surface Seal S rite atings'' Surface Seal SB Roof Coating
applied in one or more coats a in rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® us or United Coatings'"Roo e MB Plus Coating applied at
ami ' rate of 1.0 gal./sq.(to be used as a primer) o ed by TOPCOAT®
embrane or United Coatings"Roof Mate TCM Coating-app ' in one or more
coats at a minimum rate of 1.0 gal./sq.per coat.®
Maximum Design
Pressure: -300 psf. (See General Limitation#9)
NOA No.: 18-0919.13
MIAMFDADE COUNTY
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 10 of 45
CONCRETE DECK SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete.is proposed, a
field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns
and density. All testing and fastening design shall be in compliance with Testing Application Standard
TAS 105 and Roofing Application Standard RAS 117; calculations shall be signed and sealed by a Florida
Registered Engineer,Architect;or Registered Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening
pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied
using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in
three rows, one at each side lap and one down the center of the sheet allowing a continuous area of
ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in each ribbon
to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275
lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-
tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official, a
revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,Architect,or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a
Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant(When this
limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters, and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones(i.e.perimeters, extended corners and comers). (When this limitation
is specifically referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-0919.13_
MIAMI-DADecouNW Expiration Date: 11/06/23
Approval Date: 11/01/18