Loading...
HomeMy WebLinkAboutArchitect letterDwrg*FT PA-Vrs A-Xe*rTZCT, PA. Florida license 8AR0016908 1045 S.E. Riverside Drive Stuart, Florida 34996 (772)781-6695 August 24, 2020 St. Lucie County Building Department Fort Pierce, Florida RE: Phyllis Hughitt Residence 12410 Harbour Ridge Blvd. 6-3 Fort Pierce, Florida To whom it may concern: The design pressures (PSF) for the above location to replace (2) windows and (1) sliding glass doors at the second floor (20'component height) are as follows: ZONE 4 - +43.0, -46.5 ZONE 5 - +43.0 —57.4 Zone 5 is defined as 5' of building wall from building comers. Zone 4 is defined as all other wall space. Design pressures calculated with 160mph ultimate design wind speed and 124 nominal wind speed, importance factor 1.0, exposure D, surface exposure D, category II, internal pressure coefficient +.18,-18. Sincerely, Dwight Davis AIA