Loading...
HomeMy WebLinkAboutRevision; Add Hardie Plank to close Pole Barn(:Sot", OFFICE USE ONLY: DATE FILED: J '� 0-72 'PERMIT # 1911-0412 REVISION FEE: _ RECEIPT # 1 142(a PLANNING & DEVELOPMENT SER BUILDING & CODE REGULATION DIV 2300 VIRGINIA AVENU FORT PIERCE, FL 34982-5 (772) 462-1553 ' APPLICATION FOR BUILDING PER1 PROJECT INFORMATION LOCATION/SITE ADDRESS: FILE COP 11298 MULLER ROAD s FORT PIERCE, FL 34945 {v DETAILED DESCRIPTION OF PROJECT REVISIONS: ADD HARDIE PLANK TO PARTIALLY CLOSE POLE BARN 3 SECTIONS OF 4' HARDIE PLANK (12) FROM THE TOP LEAVING THE BOTTOM 4' AROUND THE POLE BARN OPEN. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: HOB - REBECCA PERCY ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: 11298 MULLER ROAD'. CITY: FORT PIERCE STATE: FL ' ZIP: 34945 PHONE (DAYTIME): 772-579-3845 FAX: OWNER/BUILDER INFORMATION: NAME: REBECCA PERCY ADDRESS:11298 MULLER ROAD CITY: FORT PIERCE STATE: FL ZIP: 34945 PHONE (DAYTIME: 772-579-3845 PAX: ARCHITECT/ENGINEER INFORMATION: NAME: ARCHITECTONIC ADDRESS: 806 DELAWARE AVE .CITY: FORT PIERCE STATE: FL ZIP: 34950 PHONE (DAYTIME): 772-460-7751 FAX: 772-460-4244 SLCCC 9123109 Revised 06130117 i ication Celt for Design f r es an Load Compliance 1. DESIGN CODE: Florida IfEi19A>fAl L-code 2017 Edition w/20_ supplements using ASCE 7-10 2. Structure Design is: _ Enclosed _ Partially Enclosed _ C,Z,_ Open Building ✓� T,.,-,-,..../ �^""-""'��� --""`�`._...._.�___--.._„� 3. Risk Category: )�_I _II _III _p 1V Exposure Category: _64 C ,D Adjustment coefficient PI I. i PRmUCT REVIEW 4. Design Wind Velocity mph _-ASD,LRFD End Zone Width A�ft. 5, Mean Roof Height: jCft. Roof Pitch: 4- :12 Parapet ft PRODUCT OPENING DESIGN PRODUCT MANUFACTURER PODEL# APPROVAL# GLASS ATTACHMENT METHOD PRESSURES (WORST DESIGN TYPE CASE) PRESSURES ROOF ZONE 1-25.4 N/A' OWENS CORNING BRKSHIRE FL N/A 6— ROOFING NAILS PER SHINGLE ZONE 2 -42.3 y1NGLE5 K 10674-R-15 ZONE 3 -64.13 WALLS ZONE 4 -30.25 N/A JAMES HARDIE 11P SIDING FL# N/A 11 GA. ROOFING NAILS (0.121" SHANK x 0.37P' HD x ZONE 5 -36-3 BUILDING 13192.2 1.25' TANG) i 24" O,G PRODUCTS — 1 6. Components & Cladding Design Pressure �used: (PSF, based on Actual sq. ft. G� 3o 'MRH (worst case) Zone 1:-91-4 Zone 2:-413' Zone 3:- y 13Zone 4:-!LrZone 5:-3413 Garage: kd A 7. Design Loads: Floor:' PSF Roof/Dead: 1,.5' PSF Roof/Live ,— PSF Balcony: _PSF Dock: _,-„PSF Deck: _ PSF Stalrs: _ PSF Fence: _PSF Railing: _ PSF ((( 8. Were Shear Walls Considered for Structure? DXYes -_Not Applicable Explain Why Not: y 9. Is a Continuous Load Path provided? - V Yes_Not applicable Explain Why Not: THE SEAL HEREON 15 PROVIDED ONLY TO INDICATE OUR REVIEW AND APPROVAL FOR L F OF PRODUCTS LISTED FOR THIS STRUCTURE. THE ACCEPTANCE OF THESE PRODUCTS AND METHODS OF -_. ATTACHMENT ARE BASED ENTIRELY UPON TEST DATA PROVIDED BY THE MANUFACTURR, WHICH CARRIES ITS OWN ENGINEER'S CERTIFICATION AND IMPLIES NO WARRANTY OR GUARANTEE BY r 'I THIS OFFICE FOR THESE PRODUCTS. !f STRUCTURAL NOTES; - 1. STRUCTURAL LUMBR TO BE HEM -FIR #2 GRADE OR BETTER WITH 1000 P.S.I. MIN. FIBER STRESS VALUE, ICI 2. CONCRETE SLABS AND FOOTINGS TO BE 2500 P,S.I. MIN. 3. REINFORCING STEEL SHALL BE GRADE 60 OR BETTER WITH 30" MIN. LAP. 4. CONCRETE COVER OVER REINFORCING STEEL; !, FOOTINGS 3" 5. FILL (SOIL) SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO A - _ MINIMUM OF 96 MODIFIED PROCTOR DENSITY, 6. ALL COMPONENT OF THIS STRUCTURE HAVE BEEN DESIGNED & SELECTED TO WITHSTAND WIND FORCES OF THE FLORIDA BUILDING CODE 2017 EDITION PER WIND LOAD COMPLIANCE. - - 7. WINDOW AND DOOR ASSEMBLY COMPONENTS TO BE CERTIFIED BY MANUFACTURER FOR WIND FORCES OF THE FLORIDA BUILDING CODE 2017 EDITION PER WIND LOAD COMPLIANCE DESIGN PRESSURES. '.. - 8.. FOR METHOD OF ATTACHMENT FOR DOORS AND WINDOWS SEE PRODUCT REVIEW AFFIDAVIT. NOTE: ALL SIMPSON STRONG TIE PRODUCTS IN CONTACT WITH TREATED LUMBERL HAVE A MINIMUM Z- MAX COATING OR BETTER. ;1 MW4Gr51 ) (Z ll �-1 xF gcA.e (n+1 E.4 PQ r IA 4T 2 >/ f PI-Ig �PC� HITECT rchitectonic Inc DELAWARE AVENUE RT PIERCE, FLORIDA 34950 '72 460 7751 '72 460 4244 VW.ARCH ITECTON ICINC.COM 4TE REG # AA26003348 ,PYRIGHT 2017 PERCY POLE BARN ST. LUCIIE COUNTY, FLORIDA NT ' � � VVIYJVLIn1Y1V Z >SEl Tz rih I 'I y I � REGISTRATION r G�^CR eoPJ�r-'.fL. w�S�fs Sff K1��.4 • e. �o1_r m IF F _L _ > AiZ96ativ- • �l s Ei A 0 49 ( REVISIONS ®`)If1- - NO. DATE REVISION / q I 7 zazo Wfsav v� _t v1 i1 .d KEY PLAN vim. " Yo 1VQS�C T TITLE / SHEET NUMBER CO tq, t►. \41i? R P�5o�,ol`'yP Q IPROJECT NUMBER 19 Oc\ DATE )Z/3 Ili i__