HomeMy WebLinkAboutENtrega tile 2019Florida Building Code Online
Business & Professional Regulation i
SCIS Home Log In ? User Registration Not Topics Submit Surcharge Stats &Facts
ba
r z (Product Approval
Iy USER: Publfc User
Product Aggro al Menu > Product or Aoolligitim Search > AaMicatien Lfst > Application Detail
FL *
FL7804-R1.0
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Entegra Roof Tile, LLC
Address/Phone/Email 1.289 NE 9th Avenue
Okeechobee, FL 34972
(602)515-6933
thomas.jemmett@boral. corn
Authorized Signature Thomas Jemmett
thomas.lemmett@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Page 1 of 2
OBPR No1,E A 1111T D P -R nb a OaA^M6145[. CONTACT 687if
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida 'Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License
PF -59166
Quality Assurance Entity
PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date
11/03/2020
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL78p4 RIO C0I 2016 01 COI Nieminen ndf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1945
TAS 102(A)
1995
TAS 112
1995
Equivalence of Product Standards
Certified By
Sections from the Code
https:Hfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bAM,gs... 3/17/2020
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approvaf
Date Approved
FL #
7804.1
Model, Number or Name
Method 1 Option D
10/17/2017
10/19/2017
10/22/2017
12/12/2017
Description
Entegra Concrete Roof Tiles (HVHZ Concrete Roof Tile
jurisdictions)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section S for Limits of Use. Refer to Eli
Section 6 for Installation.
7804.2 Entegra Concrete Roof Tlles (non-
HVHZ jurisdictions)
Limits of use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant; N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Section 6 for Installation.
Page 2 of 2
Installation Instructions
FL7804 R10 II 2017 10 FINAL ER ENTEGRA FL7804-
R10 HVHZ odf
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL7804 R10 AF 2017 10 FINAL ER ENTEGRA F1 7804-
R10 HVHZ.odf
Created by Independent Third Party: Yes
Concrete Roof Tile
Installation Instructions
FL7804 R10 II 2017 10 FINAL ER ENTEGRA F1.7804 -
R10 NON-HVHZ odf
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL7804 RIO AE 2017 10 FINAL ER ENTEGRA FL7804-
R10 NON-HVHZ.DdF
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee rL 32399 Phone: 850-487-1824
The State of Rorida is an AA/EEO employer, Logynaht 2007-2013 5.tate of Honda.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-remrds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditionai mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275
(1), Rorida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the. Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine Ir you area licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
r W1 Iva]� that
Credit Card
Safe
I
https://floridabuilding.org/pr/Pi _app_dtl.aspx?param=wGEVXQwtDquov{}jOH1%2bAMgs... 3/17/2020
Florida Building Code Online
Business a Professional i
SCIS Home Lng In User Registration r Hot Topics Submit Surcharge Stats & Facts . Publications
ba
{� Product Approval
USER: Public User
a-:
Product Approval Menu > Product or Appilcatlon Search > Application List
Search Criteria
Page 1 of 1
Cuntact Us PCIS Site Inap Links Search
Refine e_e S rchh
Code Version
2017
FL#
7804
Application Type
ALL
Product Manufacturer
Entegra Roof Tile, LLC
Category
Roofing Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Other
ALL
Search Results - Applications
FL#
Ir;
Manufacturer
Validated By
Status
FL7804-R10
Revision
Entegra Roof Tile, LLC
Jahn W. Knezevich, PE
Approved
His
Category: Roofing
(954) 772-6224
Subcategory: Roofing Tiles
Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone! 850-487-1824
The State of Florida is an AA/ELO employer. Copyright 2007-2013 Stata of Florida :: Pril Statement :: Acces i ility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455,275
(1), Florida Statutes, effective October 1, 2812, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emaits provided may be used for official communication with the licensee, However en ii addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click her
Product Approval Accepts:
OD Il l rLh
Credit Card
Safe
https://floridabuilding.org/pr/P _app_lst.aspx . 3/17/2020
r �t
ER®
TRINITY
EVALUATION REPORT
EXTERIOR RESEARCH St DESIGN, LLC.
Certificate of Authorization #9so3
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Entegra Roof Tile, LLC Evaluation Report E39310.11.11 -1-R4
1289 NE 9" Avenue FL7804-R10
Okeechobee, FL 34972 Date of Issuance: 11/02/2011
SCOPE: (602) 515-6933 Revision 4: 10/17/2017
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61th Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
d
RobertJ.Ml. Nieminen, P.E.
The facsimile
.2 err ?
�;
seal appearing was authorxed6yRobert Nieminen,
Florida Registration No. 59166, Florida DCA ANE1983
R . ....,
P.E. on 10/17/2017. This does not serve as an electronicallysi ned
,
document, Signed, sealed hardcopies have been transmitted to the
P
CERTIFICATION OF INDEAENDENCE: to uct Approval Administrator and to the named client
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates,
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRfN" ERD
ROOFING SYSTEM EVALUATION.-
1.
VALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6,5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.23
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
Ent+
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL(TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL(TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL(T5T3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, LLC.Evaluation Report E39310.11.11 -1-R4
Certificate of Authorization #9503 6TH EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4. 10/17/2017
Page 2 of 8
4. PRODUCT DESCRIPTION:
4.1 1 TAS 112, Type 3a (flat -profile)
L 16'
Y
T
2'
10'
16' �1
Bermuda Flat
(Tf�R'IINITY,IRD
BERMUDA FLAT, PLANTATION FLAT and HORIZON FLAT
lee
f
17-114"
13"
Horizon Flat
Plantation Flat
Exterior Research and Design, I.I.C. Evaluation Report E3931o.11.11-1-R4
Certificate of Authorization #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4-.10/17/2017
Page 3 of 8
4.2
4.3
4 ERD
TRINITY'
TAS 112, Type 1a (interlocking, high-profile) I BELLA ,HIGH "S"
Bella High "S"
TAS 112, Type 1b (interlocking, low -profile)
Estate "S"
4.3 1 TAS 112, Type 2a (non -interlocking, high-profile)
Galena Spanish "S"
ESTATE "S" and HACIENDA
GALENA SPANISH ""S" and REGAL
Exterior Research and Design, LLC. Evaluation Report E39310.11.11 -1-R4
Certificate ofAuthorization #9503 Gr" EDITION (2017) FBC HVHZ EVALUATION FL7804-Rio
Entegra Roof Tiles Revision 4: 10/17/2017
Page 4 of a
TRINITY ERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512,4.2.4 regarding field testing of completed the roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix'A'.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System` in
accordance with Roofing Application Standard RAS 127-11 usine the data ni,tlinarl h, -rain
TABLE 2: RESTORING MOMENT DUE To GRAVITY- M, (Fr -LBF)
Roof Slope (ej
Tile
2:12<8<3:12
3:12<9<4:12
4:12<8<5.12
5:12<9<6:12
6:12<0<7:12
8>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens Direct
Bermuda Flat
5.22
6.43
5.17
637
5.09
6.27
4.98
6.15
4.86
6.00
4.72 5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26 7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89 7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50 6.13
Estate "S"
6.14
6.84
1
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40 6.14
Hacienda
5.92
6.80
2
i7.77
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41 6.22
Galena Spanish "S"
N/A
6.20
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A 5.57
Regal
7.77
$.34
8.34
7.65
8.20
7.49
8.03
7,30
7.83
7.10 7.61
Exterior Research and Design, U.C.
Certificate of Autharization
#9503
6'
EDITION 120171
FBC HVHZ EVALUATION
Evaluation
Report
E39310.11.11 -1-R4
Entegra Roof Tiles
FL7804-Rio
Revision 4: 10/17/2017
Page 5 of 8
TRINITY ERD
TABLE 3A: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT -LBF)
MECHANICALLY ATTACHED SYSTEMS
Fastener Direct -Deck
Direct -Deck
(min. 19/32"
(min. 15132"
Type #
Size Shank Clip
p plywood)
plywood)
Battens
Nail One (1) 10d Smooth or Screw N/A 7.3
9.8
4.9
Nail Two (2) 10d Smooth or Screw N/A 14.0
18.8
7.4
Nail One (1) 10d Smooth or Screw Eave 19.0
19,0
22.1
Nall One jl) lOd Smooth or Screw Field 24.3
24.3
24.2
Nail Two (2} 10d Smooth or Screw Eave 31.9
31.9
32.2
Nail Two f2) 10d Smooth or Screw Field 35.5
35.5
34.8
Nail Two (2) 10d Ring N/A 30.9
38.1
17.2
Nail' Two (2)' 10d' Ring' N/A 50.31
65.51
48.31
Screw One (1) #8 N/A N/A 30.8
30.8
18.2
Screw Two (2)N/A 51.7
51.7
24.4
' Installation with a 4 -inch tile headlap and fasteners located min. 234 -inch from head tile.
of
Nail One (1)' 10d Smooth or Screw N/A 8.83
11.83
4.12
Nail Two (2) 10d Smooth or Screw N/A 16.4
21.9
7.1
Nail One(1)2 10d Smooth or Screw Eave 19.02
19.02
22.13
Nail One(1)2 10d Smooth or Screw Field 24.32
24.32
24.22
Nail Two (2) 10d Smooth or Screw Eave 31.9
31.9
32,2
Nail Two (2) 10d Smooth or Screw Field 35.5
35.5
34.8
Nail Two (2) 10d Ring N/A 27.8
37A
28.8
Nail' Two (2)' 10d1 Ring' N/A 43.01
67.5'
50.91
Screw One{1)2 #8 N/A N/A 25.8'
25.82
22.92
Screw Two (2) #8 N/A N/A 47.1
47.1
49.1
'Installation with a 4 -inch tile headlap and fasteners Incated min- 236 -inch from head
oftile..
z For one (1) fastener installations, utilize hole that is approximately 4Y -inch from the interlocking edge.
Nail One (1) 1od Smooth or Screw N/A 5.1
6.8
2.8
Nail Two (2) 10d Smooth or Screw N/A 6.9
9.2
7-3
Nail One (1) 10d Smooth or Screw Field 23.1
23.1
19.0
Nail One (1) 10d Smooth or Screw Eave 29.3
29.3
24.0
Nail Two (2) 10d Smooth or Screw Field 27.6
27.6
386
Nail Two (2) 10d Smooth or Screw Eave 38.1
38.1
41.8
Nail Two (2) 10d Ring N/A 28.6
41.2
19.4
Nail' Twp (2)1 10d' Ring' N/A 33.11
48.1'
S0.9'
Screw One (1) #8 N/A N/A 20.7
20.7
18.1
N/A 43.2
Screw Two (2) ��mln.
h�eea�dlap
43.2
29.8
' Installation with a 4 -inch tile 234 -inch from head of tile.
Exterior Research and Design, LCC. Evaluation Report E39310.11.11 -1-R4
Certificate ofAuthorizotion #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4: 10/17/2017
Page 6 of 8
TRINITY ERa
TABLE 4: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF (FT -LBF)
MORTAR AND ADHESIVE -SET SYSTEMS
Mote from Entegra Roof Tile, LLC. � The performance data listed in Table 4 are based on the respective adhesive manufacturers' test
reports and Miami -Dade NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to provide these values for our inclusion
in this FSC HVHZ Evaluation Report. Please consult the individual adhesive manufacturer for information on product approvals,
limitations, revisions or other information for determining wind load and overturning moment performance.
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited quality Assurance
Agency noted herein.
and/or
Lj� IE N T
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "Sr", Galena Spanish "S"
Exterior Research and Design, LLC. Evaluation Report E39310.11.11 -1-R4
Certificate of Authorization #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof riles Revision 4: 10/17/2017
Page 7 of 8
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
"TILE BONpTM"" by pow Chemical
NOA 16-0222.01
Interdependent (2 -paddy)
41
Bermuda
Flat'
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2 -paddy)
73
Plantation
"Polyset® RTA -1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2 -paddy)
5.2
Flat or
"Polyset® AH -160" by ICP Adhesives &
Interdependent (2 -paddy)
43
Horizon
Sealants
NOA 17-0322.03
Independent (medium paddy, -30 g)
51
Independent (large paddy, -45 g)
92
"TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2 -paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2 -paddy)
42
Estate "S" or
"Polyset® RTA -1" by ICP Adhesives & Sealants
NOA 16-0315.43
Interdependent (2 -paddy)
44
Hacienda
"Polyset® AH -160" by ICP Adhesives &
Interdependent (2 -paddy)
50
Sealants
NOA 17-0322.03
Independent (medium paddy, -30 g)
37
Independent (large paddy, -54 g)
61
Mortar
Various
Per RAS 120
21
"TILE 90NDT"" by Dow Chemical
NOA 16-0222.01
Interdependent (2 -paddy)
48
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2 -paddy)
52
Bella High
"S", Galena
"Polyset° RTA -1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2 -paddy)
36
Spanish "S"
"Polyset® AH -160" by ICP Adhesives &
Interdependent (2 -paddy)
30
or Regal
Sealants
NOA 17-0322.03
Independent (medium paddy, -30 g)
49
Independent (large paddy, -63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited quality Assurance
Agency noted herein.
and/or
Lj� IE N T
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "Sr", Galena Spanish "S"
Exterior Research and Design, LLC. Evaluation Report E39310.11.11 -1-R4
Certificate of Authorization #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof riles Revision 4: 10/17/2017
Page 7 of 8
TT�k'
INITY 1 E R D
ant!/or
Han on
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High) "S", Galena Spanish "S"
Ft. Myers, FL Horizon Flat, Hacienda
Deerfield Beach, FL Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.--QUA9110; (813) 621.-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, LLC. Evaluation Report E3931o.11.11-1-R4
Certificate of Authoriratian #9503 6' EDl-n ON (2017) FBC HVHZ EVALUATION F L7804 -R 10
Entegra Roof Tiles Revision 4: 10/17/2017
Page 8 of 8