Loading...
HomeMy WebLinkAbout5V Crimp MetalProduct Report Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" 772 872-8034 Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Lo ads METHOD 1 METHOD2 METHOD 3 METHOD4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" o.c. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 152 7 UL 580-06 & 1897-041 TAS 125-0 3 05/02/14 Test Report D05893.0l-450-18 Test Report F3366.0l-450-18 Test Report D05893.02-450-18 12/18/15 0 7/22/14 ··'''""''''·' ,, ,,'�x.. 0. BO �V: ,,., Locke Bowden, P.E. does not have, not will acquire a finan cial in��l�-eili'; fqmJla11.V, �;�facturing or distributing products .. .. \,� ., l .:i',t:' • / / ,,. under this evaluation. :-'v • � • ' �Locke Bowden, P.E. is not owned, operated, or controlled by ai, co�parl'lprrnithJfKtur;,, ord.istributing products under this report. ;�,1. (Mj·� :: :f"': :•:: �,... .? � � /'·. . s" · :,"-i�ilo -;,,C!<-;_ • .;:-l OH\0 � • • ·�J, "',, ,:s ,· •.•• • .... �{) .. · l,,: 10NAL t-\ ,.;,•l:itt::. 11\\\\•' *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12.*Design pressure margin of safety 2:1 See Fastener attachment specifications above Fasten r #9 × 1-1/2" Min. or #10 × 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Length Nominal 12" o.c. Nominal 12" o.c. Panel Overlap Deck- 15/32" or greater :Plywood, or -Wood plank Fasteners - #9 × 1-1/2" Min. or #10 × 1-1/2" Min. per Table "A" for Row Spacing and Design Pressures Hex Washer Head Wood Screws Refer to Table "A"Deck: - 15/32" or greater Plywood, or - Wood plank 5-V Crimp Roof Panel FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report.