Loading...
HomeMy WebLinkAboutStiebel Eltron DHC-3-1DHC Technical Specifications 17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info@stiebel-eltron-usa.com | www.stiebel-eltron-usa.com Model DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 Item no.074050 074052 074053 074051 074054 074424 074055 232204 074056 Phase - 50/60 Hz 1 Voltage 120 V 240 V 208 V 240 V 208 V 277 V 240 V 208 V 240 V 208 V 240 V 208 V 277 V 240 V 208 V Wattage 3.0 kW 3.3 kW 2.5 kW 3.8 kW 2.9 kW 4.5 kW 4.8 kW 3.6 kW 6.0 kW 4.5 kW 7.2 kW 5.4 kW 9.0 kW 9.6 kW 7.2 kW Amperage 25 A 14 A 12 A 16 A 14 A 17 A 20 A 18 A 25 A 22 A 30 A 26 A 32.5 A 40 A 35 A Min. recommended circuit breaker size 1 25 A 15 A 15 A 20 A 15 A 20 A 20 A 20 A 25 A 25 A 30 A 30 A 35 A 40 A 35 A Min. recommended wire size 2 10/2 AWG 14/2 AWG 12/2 AWG 14/2 AWG 12/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 8/2 AWG 8/2 AWG Minimum water flow to activate unit 0.32 gpm (1.2 l/min) 0.32 gpm (1.2 l/min) 0.42 gpm (1.6 l/min) 0.42 gpm (1.6 l/min) 0.42 gpm (1.6 l/min) 0.47 gpm (1.8 l/min) 0.69 gpm (2.6 l/min) 0.79 gpm (3.0 l/min) 0.79 gpm (3.0 l/min) Weight 4.6 lb (2.1 kg)5.3 lb (2.4 kg)5.3 lb (2.4 kg)4.6 lb (2.1 kg)4.6 lb (2.1 kg)4.6 lb (2.1 kg)5.3 lb (2.4 kg)5.3 lb (2.4 kg)5.3 lb (2.4 kg) Dimensions Width 77/8� (20.0 cm) x Height 143/16� (36.0 cm) x Depth 41/8� (10.4 cm) Nominal water volume 0.13 gal (0.5 l) Working pressure 150 psi (10 bar) Tested to pressure 300 psi (20 bar) Water connections 3 ½� NPT DHC 3-1, 3-2, 4-2 ship with a 0.5 gpm (1.9 l/min) pressure compensating fl ow-reducer/aerator that must be installed. 1 This is our recommendation for overcurrent protection sized at 100% of load (DP for 240/208/277 V & SP for 120 V models). Check local codes for compliance if necessary. Tankless water heaters are considered a non-continuous load. 2 Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load. 3 Suitable for supply with cold water only. Tested and certified by WQA against NSF/ANSI 372 for lead free compliance. Certified to ANSI/UL Std. 499 Conforms to CAN/CSA E335-1 & E335-2-35Technical Data Scroll for temp. rise charts.  DHC Technical Specifications 17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info@stiebel-eltron-usa.com | www.stiebel-eltron-usa.com DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 10 20 30 40 50 80 90 70 60 0 0.750.5 1.0 1.25 1.5 1.75 2.0 Te m p R i s e ° F Flow Rate GPM Temperature Rise vs. Flow Rate at Maximum Rated Voltage 0.69 0.79 DHC 3-2 DHC 4-2 DHC 5-2 DHC 6-2 DHC 8-2 DHC 10-2 10 20 30 40 50 80 90 70 60 0 0.750.5 1.0 1.25 1.5 1.75 2.0 Te m p R i s e ° F Flow Rate GPM Temperature Rise vs. Flow Rate at 208 V 0.69 0.79