Loading...
HomeMy WebLinkAboutCC Ft. Pierce Bathroom Rev2 8.26.20COCA -COLA Ft. Pierce ADA Ke5troom Renovation BUILDING CODE REFERENCE FLORIDA BUILDING CODE- 2017 Gth Edition INFORMATION ON DRAWINGS SECTION I GOG. 1.7 FBC SECTION I GOG I . BASIC WIND SPEED FLORIDA 170 MPH- 3 SECOND GUST 2. WIND IMPORTANCE FACTOR I I BUSINESS OCCUPANCY 3. WIND EXPOSURE PLORIDA WIND EXPOSURE B 4. INTERNAL PRESSURE COEFFICIENT BUILDING SIMPLE DIAPHRAGM MEETING THE 7 SHAPE CRITERIA 5. COMPONENTS* CLADDING INTERNAL PRESSURE COEFFICIENT= 0. 18 DESIGN WIND PRESSURE 32 PSF FOR COMPONENTS CLADDING DESIGN WIND PRESSURE FOR OPENINGS: +29.4 PSF / -34.7 PSF FOR 30 WIDTH OPENING STREET ADDRESS 3939 ST LUCIE BLV. FORT PIERCE, FL 3494G PARCEL NUMBER 1432-222-0001 -000-9 PARCEL ZONING INDUSTRIAL JURISDICTION: CITY of FORT PIERCE, ST LUCIE COUNTRY, FLORIDA PROJECT DESCRIPTION: INTERIOR DEMOLITION of EXISTING, NEW TENANT IMPROVEMENTS BUILDING OCCUPANCY GROUP 4 1 MANUFACTURING PARCEL DESCRIPTION COCA -COLA PLAT I G2-2 1 B PARCEL A CODE INFORMATION ADOPTED CODES FLORIDA BUILDING CODE- 2017 Gth Edition BUILDING: FLORIDA BUILDING CODE- 2017, EXISTING BUILDING FIRE: FLORIDA PREVENTION CODE- 2017 PLUMBING: FLORIDA BUILDING CODE, PLUMBING- 2017 MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL- 2017 ELECTRICAL: NATIONAL ELECTRIC CODE, 2014 ACCESSIBILITY: 2017 FLORIDA ACCESSIBILITY CODE FOR BLDG CONSTRUCTION ENERGY: FBC 2017 ENERGY EFFICIENCY FOR BLDG CONSTRUCTION S' CI f f R v ; _ % EX15TING BUILDING 51TE PLAN N® FINISH PLAN KEY NOTES F I - Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate. (30G8 solid core birch door) F2 - ADA ground and floor surfaces along accessible routes must be stable, firm and slip -resistant F3 - Ore piece plated stainless steel WashBar includes touch -free soap, water and hand dryer - ADA COMPLY Specification: Verge with washbar - LVQ-Series ( LVQD 1) F3. 1 - Ore piece plated stainless steel WashBar includes touch -free soap, water and hand dryer - ADA COMPLY Specification: Verge with washbar - LVQ-Series ( LVQD2) F4 -Waterless Urinals shall be the stall -type or the wall -hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground. Urinals shall be 13 1/2 inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. F5 -The sink high forward reach shall be 48 inches (1 220 mm) maximum where the reach depth is 20 inches (5 10 mm) maximum. Where the reach depth exceeds 20 inches (5 10 mm), the high forward reach shall be 44 inches (1 120 mm) maximum and the reach depth shall be 25 inches (G35 mm) maximum. FG -The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be I G inches (405 mm) minimum to 18 F7 -The side wall grab bar shall be 42 inches (1 O(;5 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. F8 -Rab Bars. Grab bars for water closets shall comply with GO9. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. F9 -Pictograms shall have a field height of G inches (1 50 mm) minimum. Characters and braille shall not be located in the pictogram field. F I O -ADA mirror on each sink ELECTRICAL PLAN KEY NOTES E I -ELECTRICAL OUTLETS FOR THE SINK SYSTEM n. T o5 ® 6 M a N eo I NON RATED WALL 3/8" = I' NEW EXHAUST FAN FLOOR DRAIN TO REPAIR E- LIGHT 4' UNISEX DRYWALL 1 PARTITION 2 OM�O_E5TS 3MW Digitally signed by Gregory D. Gainer, P.E. ON: c=US, st=Florida, ,..���.rg:"o;• .I. 1=Saint Petersburg, G,e �{ :,,; o=Gregory D. Gainer, P.E., cn=Gregory D. Gainer, P.E., email=pa ssm enot@ h otma i 1. com Date: 2020.8.20 16:33:10 -04'00' ELECTRICAL 3/8" = I' RELOCATED URINALS �W U OQ U � Lu zw0cN U N CO �m Z0 Z D_ m 0 O � Q Z LLJ Q Cn cn � = N CV L! — O �m s_ Ln m 00 C) L L _J — N O IL Q -1 1L s_ C� m LIU U Iz LLJ LIU U U IL �mm Q LLJ J U U � Q J U� m DATE: 07/2 1 /2020