Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MARSHALL SPECS
Protector® QS Series INCLUDES: • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. • True Power"' Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CflITERIA: PROTECTOR® US SERIES Standby Generators Liquid -Cooled Gaseous Engine Standby Power Rating Model RG022 (Aluminum -Gray) - 22 kW 60 Hz Model RG027 (Aluminum - Gray) - 27 kW 60 Hz Mo ,0 Aluminum -Gray) - 32 kW 60 Hz Model RG038 A num -Gray) - 38 kW 60 Hz o e 048 (Aluminum - Gray) - 48 kW 60 Hz Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATIDN. This stale -of -the -art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. � PROTOTYPE TESTED a NEMA MG1-22 EVALUATION O GENERAC TRANSFER SWITCHES. Lang life and reliability are 4 SYSTEM TORSIONAL TESTED t MOTOR STARTING ABILITY synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC• 22 27 32 38*Wk1jr applicalFan &engineehngi, GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32,38 & 48 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES g heary generator Revolvinfield duty Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully proloryped tested ENCLOSURE FEATURES Electrostatically Aluminum weather Ensures protection against mother nature. rotective enclosure papplied textured epoxy paint for added durability. Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (AII ratings in accoNance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271) ENGINE SPECIFICATIONS: 223 275 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bare (tn/mm) 3,41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Naturally Aspirated (22 & 27 kW) or Intake Air System Turbocharged/Aftercooled (32 & 38 kV) Litter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model VType Cylinders 8 Displacement (Liters) 5.4 Bare (tn/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Litter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qt/q 6/5.7 (48 kW) GINE COOLING SYSTEM EN Type (AII ratings in accoNance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271) ENGINE SPECIFICATIONS: 223 275 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bare (tn/mm) 3,41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Naturally Aspirated (22 & 27 kW) or Intake Air System Turbocharged/Aftercooled (32 & 38 kV) Litter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model VType Cylinders 8 Displacement (Liters) 5.4 Bare (tn/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Litter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qt/q 6/5.7 (48 kW) GINE COOLING SYSTEM EN Type ENGINE SPECIFICATIONS: 48 kW Make Generac Model VType Cylinders 8 Displacement (Liters) 5.4 Bare (tn/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Litter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qt/q 6/5.7 (48 kW) GINE COOLING SYSTEM EN Type ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qt/q 6/5.7 (48 kW) GINE COOLING SYSTEM EN Type GINE COOLING SYSTEM EN Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW (22 & 27 kW) or Fan Diameter (hymen)18.1/459.7 22/558.8 (32, 38 & 48 kW) Pusher (22 & 27 kM or Fan Mode Putter (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carhurelor Down Dratt Secondary Fuel Regulator Standard fueI Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 man HG 22 27 32 38 48 11' operating t, GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Not. Gas C8 Size (Both) 120/240 V, 10, 1.0 pf 22 92 22 92 100 RG022 120/208 V, 30, 0.8 pf 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 120/240 V, 100 1.0 pf 27 113 25 104 125 RG027 120/208 V. 30, 0.8 pf 27 94 25 87 100 120/240 V, 30, 0.8 i f 27 81 25 75 90 120/240 V. 10, 1.0 pf 32 133 32 133 150 120/208 V, 30, 0.8 i f 32 111 32 111 125 RG032 120/240 V, 30, 0.8 pf 32 96 32 96 100 2771480 V, 300 0.8 pf 32 48 32 48 60 120/240 V, 10, 1.0 i f 38 158 38 158 175 120/208 V 30, 0.8 pf 38 132 38 132 150 RG038 120/240 V 300 0.8 i f 38 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 120/240 V, 10, 1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 8G048 120/240 V, 30, 0.8 pf 48 144 48 144 150 277/480 V, 30, 0.8 pf 48 72 48 72 80 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf Natural Gas Propane 15% 30% (k3/hr) (m3/hr) (gal/hr) (1/hr) (ft3/hr) 120/240 V, iH 55 135 RG022 120/208 V, 30 40 92 120/240 V, 30 35 80 120/240 V, 10 62 170 RG027 120/208 V, 30 70 120 120/240 V, 30 61 103 120/240 V, 10 75 180 , 30 87 210 RG032R , 30 75 182 , 30 36 87 , 10 75 180 30 87 210 RG038, , 30 75 112 V, 30 36 87 120/240 V, 10 85 195 120/208 V, 30 90 218 RG048 120/240 V, 30 78 189 277/481 V, 30 36 87 Note: Fuel pipe must be sized tar full load. For Btu content, multiply B3/hr x 2520 (LP) ar ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 BIG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCADMD permitting purposes. Exercise cycle 34 1.0 0.4 1.4 13 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. ENGINE COOLING j j operating gala 22 kW 27 kW 32 & 38 kW 48 kW Air flow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 System coolant capacity (gal/liters) 2.519.5 2.5/9.5 2.5/9.5 3/11.4 Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 1 145,(300/153 186,000/I96.2 Maximum operation air temperature on radiator CC/*F) 60/150 Maximum ambient temperature (°CPF) 50/140 COMBUSTION REOUIREMENTS Flow at rated power(cfm/cmm) 1 68/1.9 1 68/1.9 1 106/3 163/4.6 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode' 1 61 61 58 63 Sound output in d8(A) at 23 8 (7 m) with generator operating at normal load' 170 70 64 68 'Sound levels are taken from the front of the generator. Sound levels taken Ito mother sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 165/4.7 180/5.1 1 300/8.5 414/11.7 Exhaust temperature at muffler outlet (OGPF) 482/900 538/1000 1 579/1075 552/1025 ENGINE PARAMETERS Rated Synchronous rpm 1800 PDWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Defation...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22, 27 & 48 kW).....................................................................................1 % lot every 100 m above 183 on or 3% for every 1000 if above 600 ft Altitude Deration (32 & 38 kW)....................................................................................... 1 % for every 100 m above 915 m or 3% for every 1000 it above 3000 If 1 •� 2-Line Plain Tex[ LCD Display, Manual......................................................... Programmable start delay between 10-30 seconds .............. Engine Start Sequence......................................................... EngineWarm-up.................................................................. Engine Cool-Dawn............................................................... Starter Lock-out................................................................... Smart Battery Charger ................. .........................I....I.......... Automatic Voltage Regulation with Over and Under Voltage F Automatic Low Oil Pressure Shutdown ................................. Overspeed Shutdown....................................4...................... High Temperature Shutdown... ...... d ..... 4 ... 4.,w..wmm ...... Overcrank Protection............................................................ SafetyFused........................................................................ Failure to Transfer Protection ................................................ Low Battery Protection.......................................................... 50 Event faun Log... ............ w ...... d.d ..... 4..4 ...... Future Set Capable Exerciser ................................................ ncorrect Wiring Protection........ ............ ......... w .... ___mm ... nternal Fault Protection..........................................4........... Common External Fault Capability ....................................... Governor Failure Protection... ...... w ... md ... d..d ............ Simple user interface for ease of operation 22 • 27 • 32 • 38 • 48 kW available accessories Madef Prodvei Uescrrhan Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with G006463-3 Mobile Link'" ? any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U S only. G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with Mobile Link l G005630-1 - 225 273 32 & 38 kW If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with G005632-1- 48 kW thermostat built into the wrap G005616-0 - 22, 27, 32 & 38 kW ` Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for G007088-0 - 48 kW Weather Kit extended periods of time. For liquid cooled units only. I G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to G005704-0 Paint Kit touch-up the paint to protect from future corrosion. The paint kit includes the j necessary paint to properly maintain or touch-up a generator enclosure. j G005656-0 - 22 & 27 kW The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware G005984-0 - 32 & 38 kW Scheduled necessary to perform complete maintenance on Generac liquid -cooled G006205-0 - 48 kW Maintenance Kit generators. E G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor Monitor provides you with instant status information without ever leaving the house. Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, G006665-0 Extension Harness required for use on units 70 kW or greater. Smart Management Modules are used in conjunction with the Automatic G006873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides Module (50 Amps) additional power management flexibility not found in any other power management system. E-stop allows for immediate fuel shutoff and generator shutdown in the event G006510 0 1 E Stop j ) of an emergency, I 3 & m kW installation layout Drawing A mAem% ( / _ \ .2./ .\:jG! .,g,_ , . ,08 . &W&r,..=s,,#J J: 2e... ag. = gsR,«<,aa's azz � e;: W00 6 &&, ! zsa�® . °°° ! 23Juba! \/\ O�E�\/T - /� \/§\6q ` ©! _ �, r,,� ,�r!§! !)!;§ ® z - - 2 ! \\§/\ \\§/ /R§ (q! �++« <n�:�s as©S qz,Z�Om \w : a2=Gga�»a«aau Im 00,< ; l;l.,:l,2:�=•�1:w�., . a aaO-� omw x «. gglau92Zgmww swoa®tROWI<Dc 6 .. 1::,;,:1=2=:rMOOm#r41;=z: : § ;}.§.:.;;_ „ ,2, !!§: ,\\\\\\x WO ;§k , §§k n§ _ ` E°§ . \\§ \ \ )) O \� )|;|! \&@ !�!!i ) �) Drawing #OK9268-A a0 aW <z _W z FX