HomeMy WebLinkAboutMARSHALL DRAWINGSLn ATTIC.. GRADE ABBREVIATIONS: AC ALTERNATING CURRENT NO AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM (CONDUCTOR) AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER(CONDUCTOR) COVE CITY OF VERO BEACH OC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER a LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLTAMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDID MAIN DISTRIBUTION PANELBOARD O EXISTING 225 AMP METER CAN 120240 iq, EXISTING (2j 618" X 8' CU GROUND RODS NEW 225 AMP MAIN BREAKER DISC. WATER LINE kl'4,LUP]F. MTS MANUAL TRANSFER SWITCH MSB MAIN SWITCHBOARD �... MLO MAIN LUGS ONLY —____ __ SURFACE MOUNT 120f240V, /0, 3-WIRE PANELBOARD NEC NATIONAL ELECTRICAL CODE NTS NOT TO SCALE FLUSH MOUNT 120124OV, 10, 3-WIRE PANELBOARD NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION _ - SURFACE MOUNT 277/48OV, 30, 4-Vir PANELBOARD NON -SE NON SERVICE ENTRANCE RATED PLCB PLACES (QUANTITY) —0— FLUSH MOUNT 27714BOV, 30, 4-WIRE PANELBOARD PNL PANEL - -- PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOFTOP UNIT ----- -- UTILITY METER CAN OR METEWMAIN COMBO UNIT BE SERVICE ENTRANCE RATED TYP TYPICAL —®— SURFACE MOUNT AUTOMATIC TRANSFER SWITCH TEMP TEMPORARY ---------- TRANS,TX TRANSFORMER UG UNDERGROUND POINT OF NEW CONNECTION UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT EXTERIOR---0----INTERIOR INTERIOR mil —EXTERIOR ATTIC NEW NEW 225 AMP 225 AMP GENERAL11 MAIN NONSE PANEL RATED ATS SCOPE OF WORK: • EXISTING INTERIOR MAIN PANEL TO BE REMOVED AND REPLACED WITH NEW 225AMP, MLO, SQUARE-D 00 54 CIRCUIT LOAD CENTER. • PROVIDE SEL NEW P NEL LLWH N WORK BREAKERS AS REQUIRED IN NEW PANEL. • E. INSTALL 2SAMPROWSE RATED ATISCOMPLETI • WALL INSTALL NONSE RATEDATS NEXT TO UTILITY METER CAN ON EXTERIOR WALL • SEPARATE NEUTRALS AND GROUNDS MAIN PANEL. • INSTALL COLD WATER BOND FROM NEW MAIN BREAKER DISCONNECT TO NEAREST CU WATER PIPING. • FPOUR CONCRETE PAD FOR GENERATOR. • PROVIDE AND INSTALL ALL GENERAC LP ORS FRRATOR. • PROVIDE (1)LOA SHED UIT AND CONDUCTORS IS SHEET. TO GENERATOR. PROVIDE AN LOAD SHED DEVICE PER SIZING DATA THIS SHEET. • SEPARATE TANKTOBE PROVIDED AND INSTALLED BY FERRELLGAB UNDER SEPARATE PERMIT. • NO CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPEPEOF OF WORK WORK. GENERAL 3BKW FINISHED FLOOR ®BREAKER -INTERIOR R as B —NE RATING NON -FUSED DISCONNECT eon � NON FUSED ,4r 11 wvzmnw FUSEDDISCONNECT aoPr-� FUSE SIZE GENERATOR AND GENERATOR PAD GAS STORAGE TANK ®I NATURAL GAS METER 1 GROUNDROD GENERAL NOTES: ' • THE ELECTRICAL CONTRACTOR SHALL VERIFY ANO COORDINATE ALL ELECTRICAL SERVICE ROUGHIN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICALINSTALLATION SHALL BE INACCORDANCE WITH THE FLORIDA BUILDINGICODE 6TH EOITION(2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014L • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERV1610N OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE, PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 250. • STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. encnwtyrlarrw ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BV MONITORING GENERATOR CURRENT AND FREDUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). 1 NTS GENERATOR ADDITION RISER DIAGRAM GENERAL NOTES: 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. 2. DARKAND RED LINE WORK REPRESENT NEW EpUIPMENT, CONDUIT, AND WIRE. SYMB fi378EBABTIAN BLVD INC GENL•- -Ac (Ti2)308-0533 32958 Sizing Report Reletl Nominal Voltage 240 for Fuel Propane (NEC Siz nit McNod(NEC220) Part IV (Pnd nl regwrea far selected drag Implementation, Bola card far whose Iwuae) General LlghOup 8 Resonances ad (kW) Square Footage Being Covered#02) 4500 13.5 SmallApPliance Circuits (20 amps) Kgagen circuits 4e laundn circuits 1 L5 seemed E Estimated amepaato N(amp) Fred In PlacaA Motors Leads V Lane Dryer X 5.5 Miuowave I'S Caok Top X 3.0 O en 50 X do Heater 50 X 5.0 OWaier IsgwazM1er 1.5 11.66 Freezer 0.8 0.8 RPefdgPamlor 0.6 mD 2.0 2.0 Well Pump 1.5 1.5 Managed Estimated E nnotata Alr Condglodn &Coot) Loads (amps) 240V lead k 4.0 Ton Unit 4.0 X 4.0 4.0 Ton Unit 4.0 X 4.0 Managed Estimaled Nameptafe Hea11ng8HeeI Pumps Leads RAN) (amps) 24DV Wad(G" Heal Pump ll0 Tan) 10.0 X 10.0 Heel Pump lt0T ) X 10.0 X 0.0 Estimated &fuel Utilized men) dGAA) 1L 3A) (URA) largest Molegr'a Sfading Amps KRA) Lora NEC Summary NEC lased (kWB flequired LlgM1ling&Receptacles 19.5 FuedraI imPlace AppllencesBMafors Sum of all General Loatls 459 24.3 Doling B a Healing (wMemard factors) 10 10 g o(Heating 8 Cooling 10 10 (zing based on requlnmmis of NEC Article 220, Pad IV 34.3 Elevation 0it Minimum silo gonaralorlor molar Starting requirements 13 BTU IOatl re9uired 725" 38 kW Generac Modal Generator Recommended N rn UQJvi W I—U-o W Q Z m m � � N O U E-1 OB/13/2020 10F2 ►i Y R I EXISTING UTILITY- ---- METER ► NEW MAIN BREAKER DISCONNECT ► NEW 1000 GAL. fl��ryl NEW PANEL ► LP TANK O (BY OTHERS) 73 ' GARAGE NEWGENERATOR ► AND PAD NEW ATS m ► �-- PLANTER N ► ► SINGLE FAMILY i RESIDENCE 13415 WAX MYRTLE TRAIL PALM CITY, FL. 34890 ► I I ► ► I I SCREENED POOL \O ENCLOSURE qpo o.� COVERED q yt�,1, PATIO Pq ` 1 ► 1 � 1 ► �1 ► I DRIVEWAY ► 1 ► 1 ► 1 ► DRIVEWAY ►�- � I r I� II C 5 115.54' N -- -� GENERATOR SITE PLAN `" E s PROPERTY LINE RILL 1l4" DEEPER THAN ANCHOR EMBEDMENT TOROUE: 45fl.ibs. EMBEDMENT: 2-12" NOTE: i. THE USE F AING CARBIDTOANSIEDRILL SIT TANDAR CONFORMING TO ANSI STANDARD 8212.1815 RECOMMENDED. 2. ANCHOR BOLTS TO BE 3/8"DIA.4-3/4"LONG UNLESS OTHERWISE NOTED. 6"MIN. } 42' --"1 84" ---� LEFT ELEVATION FRONT ELEVATION � 2 N.T.S._ GENERATOR PAD DETAIL Z Q N W KZ Mcs wgLL� Q W m N m � � O N wJ oJ� D U z c�a E-2 ,A_08/13/2020 2OF2 E-2 ,A_08/13/2020 2OF2