HomeMy WebLinkAboutWS 49 - Cover, Arch, WP, Ele, Plu 8.26.2020COMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______THESE PLANS HAVE BEEN PREPARED TO MEET THE REQUIREMENTSOF THE FLORIDA BUILDING CODE, 6th Edition (2017) RESIDENTIALw/ APPLICABLE SUPPLEMENTSOCCUPANCY: R3BUILDING TYPE: VBSPRINKLED: NOFLOOD ZONE: 'X'TERMITE PROBABILITY: VERY HEAVYBUILDING DATALOTASHMERE049ABBREVIATIONSMASMATMAXMCMINM.O.MTLN.I.C.(NTS)OHGDOPEROPNGOPTOSBOZ1/R1/SPCPNLPLYWDPREFABPRPROJPSIPSFP.T.QUADREFREINFREQ'DRNGR.O.RRNDMASONRYMLMATERIALMAXIMUMMEDICINE CABINETMINIMUMMICRO LAMMASONRY OPENINGMETALNOT IN CONTRACTNOT TO SCALEOVERHEAD GARAGE DOOROPERATOROPENINGOPTIONALORIENTED STRAND BOARDOUNCEONE RODONE SHELFPRECASTPANELPLYWOODPREFABRICATEDPAIRPROJECTEDPOUNDS PER SQUARE INCHPOUNDS PRE SQUARE FOOTPRESSURE TREATEDQUADRUPLEREFRIGERATORREINFORCEDREQUIREDRANGEROUGH OPENINGRISERROUNDMECHMECHANICALMIRMIRRORABA.F.F.ADJ.ALUM.ANCH@BD.BLDG.BM.BLKGBRG.BRK.C.J.CMUCOL.CONC.COND.CONT.CANT.CLG.CMCRDdDBL.DIA.DIR.DNDRDWDWGD.S.DTLEA.E.J.ELEC.CLBFANCHOR BOLTABOVE FINISH FLOORADJUSTABLEALUMINUMANCHORANGLEATBOARDBI-FOLDBUILDINGBEAMBLOCKINGBEARINGBRICKCONTROL JOINTCENTER LINECONCRETE MASONRY UNITCOLUMNCONCRETECONDITIONCONTINUOUSCANTILEVERCEILINGCROWN MOLDINGCHAIR RAIL DRYERPENNYDOUBLEDIAMETERDIRECTIONDOWNDOORDISH WASHERDRAWINGDOWNSPOUTDETAILEACHEXPANSION JOINTELECTRICALB.O.BOTTOM OFO.C.ON CENTERPKTPOCKET DOOROBSOBSCUREDB.P.BI-PASS DOORPDSPULL-DOWN STAIRFDFND.FLR.FPFRFRMFTGGA.GALV.GCGENGYP.GLHGT.HDR.HBINSUL.INT.LTFLOOR DRAINFOUNDATIONFLOORFIREPLACEFIRE RATEDFRAMEFOOTINGGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGYPSUMGLUE LAMHEIGHTHEADERHOSE BIBBINSULATIONINTERIORLAUNDRY TUBHCHOLLOW COREHORIZ.HORIZONTALFINISHED FLOORFIN.LAVATORYLAV.ELEVEQ.EQUIP.EXPEXT.EEELEVATIONEQUALEQUIPMENTEXPANSIONEXTERIOREACH ENDFXDFIXEDGLSGLASSHHIGHR&SSCSCHEMSHLFSHTSIMS.S.STLSTRUCTSUSPSGDSQTBT>YPTTRTRPLU.N.O.VERTV.L.I.F.WW/WDWWMWDWROD AND SHELFSOLID CORESCHEMATICSHELFSHEETSIMILARSTAINLESS STEELSTEELSTRUCTURALSUSPENSIONSLIDING GLASS DOORSQUARETOWEL BARTONGUE AND GROOVETYPICALTREADTOWEL RODTRIPLEUNLESS NOTED OTHERWISEVERTICALVERIFY LOCATION IN FIELDWASHERWITHWOODWELD WIRE MESHWINDOWWCWATER CLOSETSINGLE HUNGSHSHOWERSHWRTEMPTEMPEREDT.O.TOP OF RELEASE HISTORY TERMITE PROTECTION SHALL BE PROVIDED BY DOMINION2L TERMITICIDE/INSECTICIDE. UPON COMPLETION OF THEAPPLICATION OF THE TERMITE PROTECTIVE TREATMENT,A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THEBUILDING DEPARTMENT BY THE LICENSED PESTCONTROL COMPANY THAT CONTAINS THE FOLLOWINGSTATEMENT: "THE BUILDING HAS RECEIVED A COMPLETETREATMENT FOR THE PREVENTION OF SUBTERRANEANTERMITES. TREATMENT IS IN ACCORDANCE WITH RULESAND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENTOF AGRICULTURE AND CONSUMER SERVICES."TERMITE TREATMENT90 Matawan RoadMatawan, NJ 07747(732) 383-2200TM ELEVATION "A"5185 ARMINA PLACEFT. PIERCE, FL 34951FRONT & REAR ELEVATIONSFIRST FLOOR PLANCOVERSHEET & BUILDING DATAA2.1A1.1CS.1CS.2A2.2ROOF PLANA5.1 BUILDING SECTIONSA5.2 TYPICAL WALL SECTIONSGENERAL NOTESDRAWING INDEXFIRST FLOOR ELECTRICAL PLANE1.1SLAB PENETRATION PLANP1.1SIDE ELEVATIONSA3.1STRUCTURAL NOTESS-0.0F-1.0BLOCK PLANS-1.3 ROOF FRAMING PLANSD-1FOUNDATION DETAILSSTRUCTURAL DETAILSSD-2SLAB PLANF-2.0STRUCTURAL DETAILSPBSB-1WP1 WATERPROOFING DETAILSCS1COVER SHEET &
BUILDING DATAAREA CALCS:1,464 SF"A"ELEVATION1ST FLR/TOTAL A/CENTRYTOTAL URGARAGE33 SF385 SF2,002 SF12,688 CU. FT.TOTAL VOLUMELANAI120 SF
CEILING CONSTRUCTION:1. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE ANDITS ATTIC AREA BY NOT LESS THAN 1/2 INCH (12.7 mm) GYPSUMBOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATHHABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLEROOMS ABOVE BY NOT LESS THAN 5/8 INCH (15.9 mm) TYPE "X"GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS AFLOOR-CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THESEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2INCH (12.7 mm) GYPSUM BOARD OR EQUIVALENT.GENERAL CONSTRUCTION NOTES:EXTERIOR FINISHES:1.CEMENT PLASTER FINISH OVER MASONRY SHALL BE 5/8" THICKTEXTURED PER COMMUNITY STANDARDS.2.CEMENT PLASTER FINISH OVER WOOD SUBSTRATE SHALL BE 7/8"THICK (3) COAT STUCCO OVER (2) LAYERS OF WATER RESISTANTBARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 6THEDITION (2017) RESIDENTIAL, R703 AND ASTM C926. TEXTURE PERCOMMUNITYFLASHING:1. FLASHING SHALL BE INSTALLED AT WALL AND ROOFINTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS,AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUNDROOF OPENINGS.2. APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIEDSHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATERINTO THE WALL CAVITY OR PENETRATION OF WATER TO THEBUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHEREDMEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711.THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIORWALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGSSHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS:3. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING ATEXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THESURFACE OF THE EXTERIOR WALL FINISH OR TO THEWATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BEINSTALLED IN ACCORDANCE WITH ONE OR MORE OF THEFOLLOWING:·6*'('0'564#6+10/#07(#%674'45+056#..#6+10#0&(.#5*+0)+05647%6+10514(14#22.+%#6+105016#&&4'55'&+06*'('0'564#6+10/#07(#%674'4 5+05647%6+105+0#%%14�%'9+6*6*'(.#5*+0)/#07(#%674'4 5+05647%6+1059*'4'(.#5*+0)+05647%6+10514&'6#+.5#4'0162418+&'&2#0(.#5*+0)5*#..$'+056#..'B*'5+..1(':6'4+149+0&19#0&&11412'0+0)52#0(.#5*+0)5*#..$'5'#.'&145.12'&+057%*#/#00'4#561&+4'%69#6'4616*'574(#%'1(6*'':6'4+149#..(+0+5*14616*'9#6'4Ä4'5+56+8'$#44+'4(1457$5'37'06&4#+0#)'12'0+0)575+0)2#0(.#5*+0)5*#..#.51+0%14214#6'(.#5*+0)142416'%6+10#66*'*'#�&5+&'5·+0#%%14�%'9+6*6*'(.#5*+0)&'5+)014/'6*1&1(#4')+56'4'&&'5+)0241('55+10#.·+0#%%14�%'9+6*(/###/#(/###/#(/#9&/#14(/###/#9&/#WINDOW INSTALLATION:1. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCEWITH THE MANUFACTURERS WRITTEN INSTALLATIONINSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BEPROVIDED BY THE MANUFACTURER FOR EACH WINDOW.FLOOD ZONE REQUIREMENTS:PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGEFLOOR ELEVATION.ASPHALT SHINGLES (IF APPLICABLE) :1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALTSHINGLES SHALL BE INSTALLED IN ACCORDANCE WITHSECTION R905.2.6 AND R905.2.6.1.CHIMNEY HEIGHT REQUIREMENTS:1. WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLEDTHE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHEREIT EXTENDS THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THANTHE ROOF OR RIDGE THAT IS 10'-0" AWAY OR CLOSER.TUB AND SHOWER AREAS:1. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BOARD (NOGREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1288,C1325, OR C1178 AND INSTALLED IN ACCORDANCE WITHMANUFACTURER RECOMMENDATIONS SHALL BE USED ASBACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALLPANELS IN SHOWER AREAS.MECHANICAL AND HVAC:1. ENERGY CALCULATIONS FOR HEATING AND COOLINGCAPACITIES SHALL BE FURNISHED BY THE GENERALCONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THETIME OF APPLICATION FOR PERMIT.2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FORINSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUTREMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES,OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THEAPPLIANCE BEING INSPECTED, SERVICED, REPAIRED, ORREPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762mm) DEEP AND 30 INCHES (762 mm) WIDE SHALL BE PROVIDED INFRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS ORCEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALLBE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OROTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTOTHE GARAGE.4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICALSYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 mm) ABOVETHE FINISHED GRADE AND SHALL ALSO CONFORM TO THEMANUFACTURER'S INSTALLATION INSTRUCTIONS.5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSINGAPPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAINPAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILLOCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAINPIPING SYSTEM. THESE PANS SHALL BE INSTALLED INACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONSM1411.3.EXHAUST FANS AND VENTING:1. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERYMECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THEOUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC,SOFFIT, RIDGE VENT OR CRAWL SPACE.2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALLNOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHERDWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THEOUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMSSHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHERAREAS INSIDE THE BUILDING.3. DUCT LENGTH: THE MAXIMUM LENGTH OF A CLOTHES: DRYEREXHAUST DUCT SHALL NOT EXCEED 35 FEET. THE DRYER LOCATIONTO THE WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OFTHE DUCT SHALL BE REDUCED 2.5 FEET (762 mm) FOR EACH 45DEGREE (0.79 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE(1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCTDOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE ACLOTHES DRYER BOOSTER FAN IS INSTALLED AND LISTED ANDLABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THEEXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BEPERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FANMANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE ACLOTHES DRYER BOOSTER FAN IS INSTALLED AND NOT READILYACCESSIBLE FROM THE ROOM IN WHICH THE DRYER IS LOCATED, APERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TOWHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALLBEAR THE WORDS "THIS DRYER EXHAUST SYSTEM IS EQUIPPEDWITH A REMOTELY LOCATED BOOSTER FAN."4. PROVIDE LOUVER DEVICES AT INTAKE ANDEXHAUST LOCATIONS IN ACCORDANCE WITHAMCA STANDARD 550 IN FBC.ATTENTION GENERAL CONTRACTOR / BUILDER: ISSUANCE OFPLANS FROM THIS OFFICE SHALL NOT RELIEVE THE BUILDER OFRESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS,AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TOCOMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OFERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLEBUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THEDRAFTER'S OFFICE FOR CORRECTION BEFORE COMMENCEMENT OFANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS ORCHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THATARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETEDSHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONSARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THANTHE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELDRESPONSIBLE.FOUNDATION INSPECTION NOTES:A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OFTHE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTOR'SUSE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND ASTRING STRETCHED FROM MARKER TO MARKER TO VERIFYREQUIRED SETBACKS.FRAMING INSPECTION NOTES:ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH INSMUST BE COMPLETE, INSPECTED, AND APPROVED BEFOREREQUESTING THE FRAMING INSPECTION (FBC 110.6)EGRESS:MINIMUM SIZE.EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE AMINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET.EXCEPTION:1. ALL GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NETCLEAR OPENING OF 5 SQ FT.MAXIMUM HEIGHT FROM FLOOR:EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THEBOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHESMEASURED FROM THE FLOOR.2. OPERATIONAL CONSTRAINTS:EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BEOPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USEOF KEYS OR TOOLS. BARS, GRILLES, GRATES OR SIMILAR DEVICESARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE ANDRESCUE OPENINGS PROVIDED THE MINIMUM NET CLEAR OPENINGSIZE COMPLIES WITH SECTION 1030.4 AND SUCH DEVICES SHALLBE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THEUSE OF A KEY, TOOL OR FORCE GREATER THAN THAT WHICH ISREQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUEOPENING.3. FALL PROTECTION:WHERE THE OPENING OF THE SILL PORTION OF AN OPERABLEWINDOW IS LOCATED MORE THAN 72 INCHES (1829 MM) ABOVETHE FINISHED GRADE OR OTHER SURFACE BELOW, THE LOWESTPART OF THE CLEAR OPENING OF THE WINDOW SHALL BE AT AHEIGHT NOT LESS THAN 24 INCHES (610 MM) ABOVE THE FINISHEDFLOOR SURFACE OF THE ROOM IN WHICH THE WINDOW ISLOCATED. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24INCHES (610 MM) SHALL BE FIXED OR HAVE OPENINGS THROUGHWHICH A 4-INCH (102 MM) DIAMETER SPHERE CANNOT PASS.EXCEPTION: OPENINGS THAT ARE PROVIDED WITH WINDOWGUARDS THAT COMPLY WITH ASTM F 2006 OR F 2090.SEPARATION FROM GARAGE:PER SECTION R302.5, R302.6, OPENING PROTECTION1. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOMUSED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED.OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BEEQUIPPED WITH SOLID OR HONYCOMB CORE STEEL AND NOT LESSTHAN 1 3/8", 20 MINUTE RATED, WITH SELF CLOSER.2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE ANDITS ATTIC AREA BY NOT LESS THAN 1/2" GYPSUM BOARD APPLIEDTO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMSABOVE BY NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD OREQUIVALENT.TREADS AND RISERS:THE MAXIMUM RISER HEIGHT SHALL BE 7.75" AND THE MINIMUMTREAD DEPTH SHALL BE 10". THE TREAD DEPTH SHALL BEMEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OFTHE FOREMOST PROJECTION OF THE ADJACENT TREADS AND AT ARIGHT ANGLE TO THE TREADS LEADING EDGE. THE MINIMUMWINDER TREAD DEPTH AT THE WALK LINE SHALL BE 10", AND THEMINIMUM WINDER TREAD DEPTH SHALL BE 6". NOSING SHALLNOT BE LESS THAN 3/4" BUT NOT MORE THAN 1 1/4". A NOSINGSHALL NOT BE REQUIRED WHERE THE TREAD DEPTH IS 11".HANDRAILS:HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACHCONTINUOUS RUN OF TREADS OR FLIGHTS OF 4 OR MORE RISERS.HANDRAIL HEIGHT:HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, ORFINISH SURFACE OF RAMP SLOPE SHALL BE UNIFORM, NOT LESSTHAN 34" AND NOT MORE THAN 38".HANDRAIL GRASPABILITY:HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE ANOUTSIDE DIAMETER OF AT LEAST 1.25" AND NOT GREATER THAN2" OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THEHANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETERDIMENSION OF AT LEAST 4" AND NOT GREATER THAN 6.25" WITH AMAXIMUM CROSS-SECTION DIMENSION OF 2.25". EDGES SHALLHAVE A MINIMUM RADIUS OF 0.01".HANDRAIL CONTINUITY:HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS,WITHOUT INTERRUPTION BY NEWEL POSTS OR OTHEROBSTRUCTIONS.EXCEPTIONS:1.HANDRAILS WITHIN DWELLING UNITS ARE PERMITTED TOBE INTERRUPTED BY A NEWEL POST AT A STAIR OR RAMPLANDING.2.WITHIN A DWELLING UNIT, THE USE OF A VOLUTE, TURNOUTOR STARTING EASING IS ALLOWED ON THE LOWEST TREAD.3.HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THEBOTTOM SURFACE OF THE HANDRAIL SHALL NOT BECONSIDERED OBSTRUCTIONS TO GRASPABILITY, PROVIDEDTHAT THE FOLLOWING CONDITIONS ARE MET:3.1.THEY DO NOT PROJECT HORIZ BEYOND THE SIDES OF THEHANDRAIL WITHIN 1½" OF THE BOTTOM OF THE HANDRAILAND PROVIDED THAT, FOR EACH 1/2" OF ADDITIONALHANDRAIL PERIMETER DIMENSION ABOVE 4", THE VERTICALCLEARANCE DIMENSION OF 1½" CAN BE REDUCED BY 1/8".3.2.THEY HAVE EDGES WITH A RADIUS OF NOT LESS THAN .01".3.3.THEY OBSTRUCT NOT IN EXCESS OF 20 PERCENT OF THEHANDRAIL LENGTH.HANDRAIL CLEARANCE:CLEAR SPACE BETWEEN A HANDRAIL AND A WALL OR OTHERSURFACE SHALL BE A MINIMUM OF 1.5". A HANDRAIL AND A WALLOR OTHER SURFACE ADJACENT TO THE HANDRAIL SHALL BE FREEOF ANY SHARP OR ABRASIVE ELEMENTS.GUARDS:SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES,PLATFORMS, STAIRWAYS, RAMPS AND LANDINGS THAT ARELOCATED MORE THAN 30" MEASURED VERTICALLY TO THE FLOOROR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TOTHE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BECONSIDERED AS A GUARD.OPENING LIMITATIONS:REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THEWALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICHALLOW THE PASSAGE OF A 4" SPHERE.SCREEN PORCHES:PORCHES AND DECKS WHICH ARE ENCLOSED WITH INSECTSCREENING SHALL BE PROVIDED WITH GUARDS WHERE THEWALKING SURFACE IS LOCATED MORE THAN 30" ABOVE THEFLOOR OR GRADE BELOW.FIRE PROTECTION:FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL VERTICALAND HORIZONTAL CONCEALED DRAFT OPENINGS.HAZARDOUS LOCATIONS:1. GLAZING IN DOORS: GLAZING IN ALL FIXED AND OPERABLE PANELSOF SWINGING, SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED AHAZARDOUS LOCATION.EXCEPTIONS:1.DECORATIVE GLAZING2.WHEN THERE IS AN INTERVENING WALL OR OTHERPERMANENT BARRIER BETWEEN THE DOOR AND THEGLAZING.3.GLAZING IN WALLS ON THE LATCH SIDE OF ANDPERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSEDPOSITION.4.WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET ORSTORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN THISAPPLICATION SHALL COMPLY WITH SECTION R308.4.3.5.GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIODOORS.2. GLAZING IN WINDOWS:GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETSALL OF THE FOLLOWING CONDITIONS:1.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9SQUARE FEET.2.BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.3.TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.4.ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914MM) HORIZONTALLY OF THE GLAZING.3. GLAZING AND WET SURFACES:GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACINGSWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THEGLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANYWALKING SURFACE SHALL BE CONSIDERED A HAZARDOUS LOCATION. THISSHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING.EXCEPTION: GLAZING THAT IS MORE THAN 60" (1,524 mm), MEASUREDHORIZONTALLY AND IN A STRAIGHT LINE, FROM THE WATER'S EDGE OF ABATHTUB, HOT TUB, SPA, WHIRLPOOL, OR SWIMMING POOL OR FROM THEEDGE OF A SHOWER, SAUNA, OR STEAM ROOM.4. GLAZING ADJACENT TO THE BOTTOM OF A STAIR LANDING:GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAYWHERE THE GLAZING IS LESS THAN 36" ABOVE THE LANDING AND WITHIN 60"HORIZONTALLY OF THE BOTTOM TREAD SHALL BE CONSIDERED AHAZARDOUS LOCATION.DRAFTSTOPPING:IN COMBUSTABLE CONSTRUCTION WHERE THERE IS USABLESPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF AFLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLEDSO THAT THE AREA OF THE CONCEALED SPACE DOES NOTEXCEED 1,000 SQUARE FEET. DRAFTSOPPING SHALL DIVIDE THETHE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS.WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANEABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPINGSHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THEFOLLOWING CIRCUMSTANCES:1. CEILING IS SUSPENDED.2.FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYP OPEN-WEBPERFORATED MEMBERS.1. MATERIALS:DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2"GYPSUM BOARD, 3/8" WOOD STRUCTURAL PANELS OR OTHER#22418'&MATERIALS ADEQUATELY SUPPORTED.DRAFTSTOPPING SHALL BE INSTALLED PARALLELL TO THEFLOOR FRAMING MEMBERS UNLESS OTHERWISE #22418'& BYTHE BUILDING OFFICIAL.R506.2.3 VAPOR RETARDER :A 6-MIL POLYETHYLENE OR APPROVED VAPOR RETARDER WITHJOINTS LAPPED NOT LESS THAN 6 INCHES (152 MM) SHALL BEPLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASECOURSE OR THE PREPARED SUBGRADE WHERE NO BASECOURSE EXISTS. EXCEPTIONS1.GARAGES, UTILITY BUILDINGS AND OTHER UNHEATEDACCESSORY STRUCTURES.2.FOR UNHEATED STORAGE ROOMS HAVING AN AREA OFLESS THAN 70 SQUARE FEET (6.5 M2) AND CARPORTS.3.DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOTLIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE.4.WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ONLOCAL SITE CONDITIONS.R309.1 FLOOR SURFACE:GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLEMATERIAL.THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHERVEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDSTO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY.R302.9 FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX FOR WALLAND CEILING FINISHESFLAME SPREAD AND SMOKE DEVELOPED INDEXES FOR WALL ANDCEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1THROUGH R302.9.4.R302.10 FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX FORINSULATIONFLAME SPREAD AND SMOKE-DEVELOPED INDEX FOR INSULATION SHALLBE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5.CS2GENERAL NOTESCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______
FIRST FLOOR PLAN SCALE: 1/4"=1’−0"*ABRKA1.1FIRST FLOOR PLANK. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.ARCHITECT:DAWN BOGGIO KORBELAKSIGNATURE:______________________DATE:______2’−11"1’−2" MAX.2x6 STUD WALLSEE PLANS FORWALL LAYOUTSUBFLOORBASE CABINET ASPER SHOP DWG.FINISH FLOORTOP PLATE1/2" GYP.BD.WD.BASEMOLDINGFINISHFLOORSOLID SURFACE COUNTERTOP.INSTALLER TO PROVIDEAPPROPRIATE COUNTERTOPSUPPORT IF REQUIRED2x WOOD/STEEL FRAMEDPARTITIONINTERIOR PARTITION w/INSULATIONCMU WALLCMU WALL w/ FURRING &INSULATIONNOTE: INTERIOR WALLS ARE DRAWNTO ROUGH DIMENSIONSDOORS LOCATED ADJACENT TO WALLINTERSECTIONS ARE TO BE PLACED 3"MEASURED FROM INTERSECTION TODOOR JAMB UNLESS DIMENSIONED ORNOTED OTHERWISE.DOORS LOCATED WITHIN ALENGTH OF WALL ARE TO BECENTERED UNLESSDIMENSIONED OR NOTED OTHERWISE.ABNOTE: TYP. WINDOW HEAD HGT.AT 7’−4" U.N.O.
8'-8"
7'-4"FIN. FLOORT.O. MASONRYT.O. WINDOW5:125:121257'-4"16070 GARAGE DOOR3068SOLID PANEL DR.*25 SH1'-0"1'-0"4" WIDE STUCCO BAND (+1)4" WIDESTUCCO BAND(+1)6" ALUMINUM WRAPPEDFASCIA W/ VINYLVENTED SOFFIT, TYP.ROOF SHINGLES PERCOMMUNITY SPECS.6" ALUMINUM WRAPPEDFASCIA W/ VINYLVENTED SOFFIT, TYP.125216'-334"17'-4"
COACH LIGHT ℄12'-6"ROOF MEAN HEIGHTROOF PEAK HEIGHT35 SH6068 SGD*35 SH1'-0"7'-4"
TYP.5:12ROOF SHINGLES PERCOMMUNITY SPECS.5512121'-0"9"5124"+1RAISEDSTUCCOBAND4"2"4"4"2"RAISEDSTUCCOBAND+14"4"2"RAISEDSTUCCOBAND+1WINDOW HEAD & SILL DETAILSSCALE: 3/4"=1'-0"2GARAGE HEADTRIM DETAILSCALE: 3/4"=1'-0"1REAR ELEVATIONSCALE: 1/4"=1'-0"FRONT ELEVATIONSCALE: 1/4"=1'-0"PAINT AND FINISH SCHEDULE / KEYNOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWNAROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILLOF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD &SILL THE TRIM COLOR.PAINT COLOR SCHEMEBODY COLORTRIM COLORSAND FINISHMEDIUM TEXTURE /SKIP TROWEL FINISHSURFACE TEXTURE / FINISH KEYSTUCCO INSTALLATIONSTUCCO AND PORTLAND CEMENT PLASTER SHALLBE INSTALLED PER THE CURRENT ASTM C926 & C1063REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE%10641.,1+065 IN 3-COAT STUCCO SHALL BE USED TODELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. ORAT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTSPER ASTM C1063 (CURRENT EDITION)9''25%4''& SHALL BE INSTALLED AT ALLSTUCCO TRANSITIONS BETWEEN WOOD AND MASONRYAS REQUIRED BY ASTM C1063 (CURRENT EDITION)567%%1 SHALL NOT BE LESS THAN 3 COATS WHEN APPLIEDOVER METAL OR WIRE LATH AND SHALL NOT BELESS THAN 2 COATS WHEN APPLIED OVER MASONRYA2.1FRONT & REAR ELEVATIONSCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______WINDOW SILLWINDOW HEAD
*25 SH1'-0"1'-0"FIN. FLR.7'-4"ROOF SHINGLES PERCOMMUNITY SPECS.5:12551212512TYP.
9"
7'-4"8'-8"T.O. MASONRY512FIN. FLR.35 SH7'-4"ROOF SHINGLES PERCOMMUNITY SPECS.5:125512125125:121'-0"1'-0"1'-0"TYP.
9"
7'-4"
8'-8"T.O. MASONRY512LEFT ELEVATION SCALE: 1/4"=1'-0"PAINT AND FINISH SCHEDULE / KEYNOTE: WRAP THE SAND FINISH TRIM BAND (WHERE SHOWNAROUND WINDOWS & DOORS) INTO THE JAMB, HEAD & SILLOF THE WINDOW & DOORS. PAINT THE BAND, JAMB, HEAD &SILL THE TRIM COLOR.PAINT COLOR SCHEMEBODY COLORTRIM COLORSAND FINISHMEDIUM TEXTURE /SKIP TROWEL FINISHSURFACE TEXTURE / FINISH KEYSTUCCO INSTALLATIONSTUCCO AND PORTLAND CEMENT PLASTER SHALLBE INSTALLED PER THE CURRENT ASTM C926 & C1063REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE%10641.,1+065 IN 3-COAT STUCCO SHALL BE USED TODELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. ORAT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTSPER ASTM C1063 (CURRENT EDITION)9''25%4''& SHALL BE INSTALLED AT ALLSTUCCO TRANSITIONS BETWEEN WOOD AND MASONRYAS REQUIRED BY ASTM C1063 (CURRENT EDITION)567%%1 SHALL NOT BE LESS THAN 3 COATS WHEN APPLIEDOVER METAL OR WIRE LATH AND SHALL NOT BELESS THAN 2 COATS WHEN APPLIED OVER MASONRYRIGHT ELEVATIONSCALE: 1/4"=1'-0"A2.2SIDE ELEVATIONSCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______
5:12
5:12
5:12
5:125:125:121'-0"1'-0"1'-0"1'-0"OFF RIDGE VENT,TYP.1'-0"1'-0"5:12
5:12
5:12THE MINIMUM NET FREE VENTILATING AREA SHALL NOTBE LESS THAN 1/150 OF THE VENTED SPACE.EXCEPTION: THE MINIMUM NET FREE VENTILATION AREASHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOTLESS THAN 40 PERCENT AND NOT MORE THAN 50PERCENT OF THE REQUIRED VENTILATING AREA ISPROVIDED BY VENTILATORS LOCATED IN THE UPPERPORTION OF THE ATTIC OR RAFTER SPACE. UPPERVENTILATORS SHALL BE LOCATED NOT MORE THAN 3FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OFTHE SPACE, MEASURED VERTICALLY, WITH THE BALANCEOF THE REQUIRED VENTILATION PROVIDED BY EAVE ORCORNICE VENTS. WHERE THE LOCATION OF WALL ORROOF FRAMING MEMBERS CONFLICTS WITH THEINSTALLATION OF UPPER VENTILATORS, INSTALLATIONMORE THAN 3 FEET (914 MM) BELOW THE RIDGE ORHIGHEST POINT OF THE SPACE SHALL BE PERMITTED.ATTIC VENTILATIONSQ. FT. ATTICAREANET FREE AREASOFFIT VENTINGNET FREE AREAUPPER ROOF VENTING2002547 sq. in.414 sq. in.VENTS REQUIRED48" TAMCO OFF-RIDGE VENT (138 SI NET FREE) - 3 ventsNOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL HIPS RIDGES ORVALLEYS, MIN., TYP.TOTAL VENTING REQUIRED961 SQ. INROOF PLANSCALE: 1/4"=1'-0"UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED INACCORDANCE WITH SECTION R905, TABLE R905.1.1FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2FOR TILE ROOFING REFERENCE TO SECTION R905.3A3.1ROOF PLANCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______
%#4)#4#)'.0&;-+6%*'0190'4557+6'%.A5.12A5.12125PRE-ENGINEERED ROOF TRUSSESSEE FRAMING SHEET FOR DETL'SROOF SHINGLES PER COMMUNITYSPECS. (TYP.)125125CONCRETE FOOTINGSEE STRUCTURAL PLANSFIN. FLR.8'-8"T.O.M.T.O.WDW7'-4"REF.SPACER-4.1INSULATIONR-11INSULATIONR-30 INSULATION$'&411/.0&;)4'#6411/
$';10&$'&411/FIN. FLR.8'-8"T.O.M.125PRE-ENGINEERED ROOF TRUSSESSEE FRAMING SHEET FOR DETL'SR-30 INSULATION125ROOF SHINGLES PER COMMUNITYSPECS. (TYP.)A5.11A5.11T.O.WDW7'-4"CONCRETE FOOTINGSEE STRUCTURAL PLANSTRANSFER GRILLR-4.1INSULATIONR-4.1INSULATIONCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______
BUILDING SECTIONSBUILDING SECTIONSCALE: 1/4"=1'-0"2BUILDING SECTIONSCALE: 1/4"=1'-0"1A5.1
ROOF SHINGLES OVERSYNTHETIC POLYMER-BASEDROOFING UNDERLAYMENTROOF SHINGLES OVERSYNTHETIC POLYMER-BASEDROOFING UNDERLAYMENTROOF SHINGLES OVERSYNTHETIC POLYMER-BASEDROOFING UNDERLAYMENTNOTE: THESE DETAILS DEPICTARCHITECTURAL SPECIFICATIONS ANDFINISHES ONLY. REFER TO STRUCTURALDRAWINGS FOR STRUCTURAL INFORMATIONPROVIDE 2X4FRAMEDENCLOSURE FORELECTRICALPANEL, FINISH W/12" GYPSUMBOARDELECTRICALPANELCONCRETECURB REFERTO PLANSELECTRICALPANELCONCRETECURB REFERTO PLANSGYPSUMBOARDGYPSUMBOARDGARAGE016' ELECTRICALPANEL IS TO BEINSTALLED ACCORDINGTO ALL APPLICABLELOCAL, STATE ANDNATIONAL CODES.VERIFY PANELDIMENSIONS PRIOR TOCONSTRUCTION.CONCRETESLAB ONGRADE ATGARAGEFLOORATTIC OR SECONDFLOOR LIVING SPACEREFER TO PLANS12" GYPSUMBOARDNICHE FORELECTRICALPANEL &WIRING2'-4"
6'-2"
2'-4"3'-2"
6'-2"
8"
PER PLAN3"1'-0"3"1'-6"3 1/2"EXTERIORCMU BLOCKWALLEXTERIORCMU BLOCKWALLSTUCCOFINISHELECTRIC METERLOCATION - SEEPLANS. VERIFYINSTALLATION INFIELD3'-2"8"
PER PLAN
T.O.MGRADEATTIC ORSECOND FLOORLIVING SPACEREFER TO PLANSELECTRICAL PANEL NICHE AT CMU BLOCK WALLSCALE: 1/2" = 1'-0"PRECAST WIN. SILL1x PT DRAPE BLKGABOVE WINDOWS 1/2"G.W.B.WINDOW PER PLANBASE BOARDTYP. 1-STORY WALL @ WINDOWSCALE: 1/2" = 1'-0"SEESEE STRUCTURALPLAN2x6 ALUM WRAPPED FASCIABD. w/ALUM DRIP EDGE.SOFFIT PER SPECSSEE ROOFELEV.12PLANPRE-ENGINEERED ROOFTRUSSES AT TYP. 24" O.C.BOTTOM CHORD VARIES. REFERTO TRUSS MFGR. DRAWINGS.HURRICANE STRAP EACH ENDOF TRUSS - REFER TOSTRUCTURAL.1/2" (MIN.) CLG. BD.(REFER TO ELEV.)TOP OF C.M.U.INSULATION PERCOMMUNITY SPEC.SEE ENERGY CALCS.FIN. FL.0'-0"FOUNDATIONPER STRUCTURAL DRAWINGSSLOPE GRADE AWAYFROM HOUSE1/2" GYP. BD. OVER RADIANTBARRIER INSULATION (R-4.1)ATTACHED TO 1x2 PT.FURRING @ 24" O.C.GYP.BD.WINDOW SILLPERIMETER MASONRY SEAT1 12" BELOW TOP OF SLABSEESEE STRUCTURALPLAN1/2" (MIN.)CLG. BD.(58" TYPE 'X' GYP. BD.TO BE PROVIDEDWHEN LIVING SPACEIS ABOVE GARAGE)2x6 ALUM WRAPPED FASCIABD. w/ALUM DRIP EDGE.SOFFIT PER SPECSSEE ROOFELEV.12PLAN8" CMU BLOCKW/ CEMENTITIOUSFINISH (BEYOND)(REFER TO ELEV.)TOP OF C.M.U.WALL SECTION @ GARAGE DOORSCALE: 1/2" = 1'-0"3/4"SLOPEFIN. FL.0'-0"FOUNDATIONPER STRUCTURAL DRAWINGSDRIVEWAY PER COMMUNITYSPECSSLOPEGARAGE SLAB,SEE STRUCTURALPLANS4"PRE-ENGINEERED ROOFTRUSSES AT TYP. 24" O.C.BOTTOM CHORD VARIES. REFERTO TRUSS MFGR. DRAWINGS.HURRICANE STRAP EACH ENDOF TRUSS - REFER TOSTRUCTURAL.EXPANSION JOINTSLOPETYP. CMU COLUMN @ LANAI/PORCHSCALE: 1/2" = 1'-0"SEESEE STRUCTURALPLANSMOISTURE RESISTANTDRYWALL CEILING2x6 ALUM WRAPPED FASCIABD. w/ALUM DRIP EDGE.SOFFIT PER SPECSSEE ROOFELEV.12PLAN(REFER TO ELEV.)TOP OF C.M.U.8" CMU BLOCKW/ CEMENTITIOUS FINISHFIN. FL.0'-0"FOUNDATIONPER STRUCTURAL DRAWINGSSLOPE GRADE AWAYFROM HOUSEPRE-ENGINEERED ROOFTRUSSES AT TYP. 24" O.C.BOTTOM CHORD VARIES. REFERTO TRUSS MFGR. DRAWINGS.HURRICANE STRAP EACH ENDOF TRUSS - REFER TOSTRUCTURAL.COMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______A5.2TYPICAL WALL SECTIONS
KICKOUT DETAILSCALE: N.T.S.STEP 1STEP 2STEP 3STEP 4FOLD INWARD @ PT. AFOLDAFOLD INWARD @ PT. ACREASE @ PT. BABFOLD @ 45°FOLD INWARD @ PT. ACREASE @ PT. BBCCREASE @ PT. CABCAFOLD INWARD @ PT. ACREASE @ PT. BCREASE @ PT. CFOLD @ 77°WATERTIGHT SEAL.FOLD. DO NOT CUT.BOTTOM FLANGEFOLD PT. C OVER PT. B TILLPT. C TOUCHES BOTTOM FLANGE78" THICK, 3 COATCEMENT PLASTERWRAP LAYERS OF BUILDINGWRAP OVER NAILING FLANGE, STOPWRB APPROX. 1-1/2" ABOVE SHINGLESROOF/WALL SCREED5X5 WALL FLASHINGKICK-OUT FLASHING (SEE DTL. BELOW)SHINGLE ROOFINGFELT UNDERLAYMENTFASCIA WRAPDRIP EDGE: OVERLAP 3", EXTENDBELOW SHEATHING, MECH. FASTEN4" O.C. MAX.LAP
UNDERLAYMENT
12-18"LAPUNDERLAYMENT
1
2
-
18
"3" MIN.3"
M
IN
.
5" MIN.60 MIN. GRADE D PAPER BACKED LATHBARRICADE PLUS WRB (OR APPROVED EQUAL)6"6"6"EXTERIOR CMU WALL1) PROTECTO WRAP LWM200 ORSIMILAR ON WINDOW SILL, JAMBSAND HEAD. APPLY AROUNDCORNER AND EXTEND 6" ALLAROUND THE EDGES OF THE WALL2) SET P.T. WOOD BUCKOVER CMUWATERPROOFING INURETHANE SEALANT.FASTEN PER PRODUCTAPPROVALS.3) APPLY LIQUIDWATERPROOFINGMEMBRANE OVER THE TOPAND EXTERIOR FACE OFBUCK AND SILL4) INSTALL WINDOWOR DOOR. FASTEN PERPRODUCT APPROVALSAND SEAL WINDOW ORDOOR FRAME TO P.T.WOOD BUCK ANDMASONRYCMU OPENING WATERPROOFINGSCALE: N.T.S.SEAL EDGE OF P.T. WOODBUCK TO MASONRYPRECAST SILLCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______WP1WATERPROOFING
DETAILS
220VDV
SGFI 48" AFF
GFI 48" AFFADD BLOCKINGAS REQUIREDADD BLOCKINGAS REQUIREDADD BLOCKINGAS REQUIREDWP/ GFIA/CDISCONNECT220VDISCONNECT110V/GFIGFIS3SS3
SGFISSS SADD BLOCKINGAS REQUIREDADDBLOCKINGAS REQ'DSS3S3S3SCH GFICH GFISUNDER-SINKSWITCH FORDISPOSALREF.GFI 220VSSSVP3-BULBFIXTURES3-BULBFIXTUREATTIC LIGHTP.B. FORCHIMESADDBLOCKINGAS REQ'DS3S3S3SGFI℄SP.C.ELECTRICALPANEL ON2X4 WALL(V.I.F.)IRRIGATION TIMERLOCATION VARIESPER MAIN WATERSERVICECONNECTIONS3 S3
CHTVCAT 5TVCAT 5VPWH220V
WHDISCONNECTDW4'-0"
GFI
GFI5'-1"10'-0"MECH2'-0"WP/GFISTRUCTUREDWIRE PANEL(SWP)OWNER'SSUITEOWNER'SBATHBEDROOM 3FOYERLNDYBEDROOM 2HALLBATHKITCHEN2 CARGARAGEOS WICLCLCLENTRYDININGAREAGREATROOMHALLCLLPTRYCLMECHPREWIRE FORGARAGE DOOROPENERGFI
GFI
SDSDSDCMCMM.#0#+SVPWP/ GFIWP/ GFI3#3/0 AL, 1#6G 1 12" C150 A MLO PANEL42 CIRCUITS N1150 A METERCOMBO 120/240V1ph. N3R 22K AIC150A/2P#4 GROUND WIREBLDG STEEL2 GROUND ROD58"x8' GALV.2" PVC STUBDOWN FORFLORIDAPOWER &LIGHTELECTRICAL RISER DIAGRAMASHMERELOAD CALCULATIONSPANEL "A"DESCRIPTIONLOAD KVAGENERAL LTG. 3Wx1464 S.F.4392SMALL APPLIANCESMALL APPLIANCEREFRIGERATORDISHWASHERDISPOSALMICROWAVERANGEWATER HEATERDRYERWASHERLAUNDRYEXTERIOR GFIIRRIGATIONGDOTOTAL KVAAHU #1 HEATFIRST 10KWBALANCE @ 40%AC LOADTOTAL LOADKVA/240V150015001200240085012008000450050001500150015008009003674210000KWx.6565001000010697650027197113AMPSWIREPOLETRIPDESCRIPTIONCKTWIREPOLETRIPDESCRIPTIONCKT15379111315171921232527293135333739264810121614182022262428303236343840#10#6#12#12#12#12#12#12#12#12#12#12#12#6#10#10#12#14#14#14#14#14#142P2P1P1P1P1P1P1P1P1P1P1P1P30A60A20A20A20A20A20A20A20A20A20A20A20A2P50A2P2P25A30A20A1P1P1P1P1P1P1P15A15A15A15A15A15ASPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEAIR COMPRESSORAIR HANDLERDISHWASHER (AF/GFI)DISPOSAL (AF/GFI)WASHER (AF/GFI)REFRIGERATOR (AF)SMALL APPLIANCE (AF/GFI)SMALL APPLIANCE (AF/GFI)BATH (GFI)GARAGE DR. OPENER (GFI)GARAGE (GFCI)SPRINKLER SOLENOIDEXTERIOR (GFI)RANGEWATER HEATERDRYERMICROWAVE (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)GENERAL LTG. (AF)FIRST FLOOR ELECTRICAL PLANSCALE: 1/4"=1'-0"FOUR-WAY SWITCHCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED INCANDESCENT LIGHT FIXTUREVAPOR PROOF LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREEXHAUST FAN/LIGHT COMBINATIONPUSHBUTTON SWITCH (OPTIONAL)ELECTRIC PANELNOTES:DISCONNECT SWITCHTELEPHONE (OPTIONAL)TELEVISION (OPTIONAL)ELECTRIC METERCHIMES (OPTIONAL)SMOKE DETECTOREXHAUST FANP.C.KEYLESS LIGHT FIXTUREDUPLEX CONVENIENCE OUTLETWEATHERPROOF DUPLEX OUTLETGROUND FAULT INTERRUPTER DUPLEX OUTLET ELECTRICAL KEY220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHCOMBINATION SMOKE / CO2 DETECTORTVSMS3S4WPGFISDCHCM OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLINGROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS,AND GARAGES, SHALL REQUIRE AFCI PROTECTION.JUNCTION BOXJ ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC406.12. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO ANELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITHA MONITORED BATTERY BACKUP. PROVIDE AND INSTALLLOCALLY CERTIFIED SMOKE DETECTORS.UNLESS OTHERWISE INDICATED, INSTALL SWITCHES &RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHFLOOR:SWITCHES...........42"OUTLETS.............14"ABOVE COUNTER OUTLETS......46"TELEPHONE.........14"TELEVISION..........14" PROVIDE AND INSTALL GROUND FAULTCIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUITINTERRUPTERS (AFCI) PER 2014 NEC 210.12STANDARD ELECTRICAL LINE IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIANTO INSURE THAT ALL ELECTRICAL WORK IS IN FULLCOMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS,CODES, AND ORDINANCES.CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLEDPER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLEDFIXTURES SHALL BE HIGH-EFFICIENCY LAMPSGFCI DEVICES SHALL BE READILY ACCESSIBLE12. REFER TO ENERGY CALCULATIONS FOR ADDITIONALINFORMATION.PROVIDE THE REQUIRED CLEARANCES AROUND PANELSANDDISCONNECTS IN COMPLIANCE WITH NEC 110.26. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PERNEC 406.12. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) INA GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THEGARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLETSHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PERFBC E3901.9.VPE1.1FIRST FLOOR
ELECTRICAL PLANCOMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______LOAD CALCULATIONSSCALE: N.T.S.PANEL SCHEDULESCALE: N.T.S.ELECT. RISER DIAGRAMSCALE: N.T.S.
DV
HB.DWMECHOWNER'SSUITEOWNER'SBATHBEDROOM 3FOYERLNDYBEDROOM 2HALLBATHKITCHEN2 CARGARAGEOS WICLCLCLENTRYDININGAREAGREATROOMHALLCLL15'-1012"
18'-5"
21'-212"1'-912"40'-1"9'-11"2'-312"44'-412"
41'-1012"
25'-912"16'-1012"43'-0"PTRYCL45'-6"MECHLOCATION VARIESPER MAIN WATERSERVICECONNECTION22'-912"11'-312".#0#+COMMUNITY:SHEETRELEASED:TMASHMERE - LOT #049 BLOCK #000PLAN # 61008/25/20No.date DESCRIPTION
REVISIONS
WATERSTONE90 MATAWAN ROAD
MATAWAN, NJ 07747 (732) 747-7800
K. HOVNANIAN HOMES EXPRESSLY RESERVES ITS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS & DRAWINGS. THESE PLANS & DRAWINGS ARE NOT TO BE REPRODUCED IN ANY FORM OR MANNER WITHOUT WRITTEN CONSENT.
ARCHITECT:
DAWN BOGGIO KORBELAK
LICENSE # AR94880
90 MATAWAN RD, 5TH FL, MATAWAN, NJ 07747
SIGNATURE:______________________DATE:______SLAB PENETRATION PLANSCALE: 1/4"=1'-0"P1.1SLAB PENETRATION PLANPLUMBING RISER DIAGRAMSCALE: N.T.S.