HomeMy WebLinkAboutStructural Construction PlansGENERAL NOTES: CODES AND STANDARDS 1. THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES: 1.1. FLORIDA BUILDING CODE 2017, FBC EXISTING 2017, ASCE 7-10, ASO, AISC, & CITY OF MIAMI BEACH CODE OF ORDINANCES. 2. DIMENSIONS 2.1. BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS TO PROPERLY SIZE OR FIT THE WORK. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BY THE OWNER RESULTING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT. 2.2. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH ANY WORK. DIMENSION NOTES: 1. UNLESS SPECIFICALLY DETAILED ON THESE DRAWINGS, CONTRACTOR SHALL FURNISH AND INSTALL ADEQUATE SHORING BRACING AS REQUIRED DURING DEMO, ETC. REQUIRED TO SAFELY SUPPORT ALL CONSTRUCTION LOADS AND SHALL BE FULLY RESPONSIBLE FOR THE SAME. SHORING MUST COMPLY WITH ALL LOCAL AND OSHA REQUIREMENTS. 2. DETAILS AND CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN ACCORDANCE WITH DETAILS SHOWN FOR SIMILAR CONDITIONS AND MATERIAL. FOUNDATION NOTES: 1. ALL FOUNDATIONS, SLABS, AND FOOTINGS ARE EXISTING TO REMAIN. CUT AND REWORK CONCRETE SLAB TO RELOCATE PLUMBING PER PLANS. NEW CONCRETE AT REAR PATIO SLAB WHICH HAS NON—STRUCTURAL CRACK. THE PATIO SLAB IS TO BE RECONSTRUCTED PER PLANS. 2. BOTTOM OF SLABS/FOOTINGS TO BEAR ON SOIL CAPABLE OF SAFELY SUPPORTING MIN. 2000 PSF. CONTRACTOR TO PROVIDE', REPORT OF COMPACTION TEST TO SHOW 95% MODIFIED PROCTOR DENSITY. STRUCTURAL DESIGN CRITERIA: MEAN ROOF HEIGHT 15 OCCUPANCY TYPE RESIDENTIAL CONSTRUCTION TYPE VB WIND LOAD CHAPTERS 1, 2, 26, & 28 OF ASCE 7-10 WIND VELOCITY 170 MPH; ULTIMATE WIND SPEED WIND VELOCITY 132 MPH; NOMINAL WIND SPEED EXPOSURE "D"; ENCLOSED DESIGN Qz 73 PSF Kz 1.03 LAMBDA HEIGHT & EXPOSURE FACTOR 1.47 ROOF SLOPE 18.4' LOAD COMBINATIONS ASCE 7-10 CHAPTER 2.4: DL+LL; DL+0.6WL; 0.6DL+0.6WL INTERNAL PRESSURE COEFFICIENT +/-0.18 PER TABLE 26.11-1 RISK CATEGORY II ROOF LIVE LOAD 20 PSF ROOF DEAD LOAD 30 PSF (20 PSF TOP, 10 PSF BOT) DEFLECTION CRITERIA: LIVE = L/360 DEAD + LIVE = L/240 WIND (EXTERIOR WALLS) L/240' MAIN FRAME: MAX. HORIZONTAL LOAD +63 PSF MAX. VERTICAL LOAD —54 PSF DEMO AND INSTALLATION: 1. PRIOR TO INSTALLATION THE CONTRACTOR WILL VERIFY ALL DIMENSIONS. THE .CONTRACTOR UNDERSTANDS THAT THE EXISTING BUILDING WILL REQUIRE MODIFICATION AS SHOWN IN THE DRAWINGS. 2. THE CONTRACTOR IS TO COMPLETELY REMOVE AND DISPOSE OF ALL MATERIALS THAT ARE SO INDICATED INCLUDING WOOD, DRYWALL, AND CONCRETE. 3. THE LOCATION OF ALL EXISTING UTILITIES ARE THE CONTRACTOR'S RESPONSIBILITY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR EXACT LOCATIONS. PRIOR TO THE START OF DEMOLITION THE CONTRACTOR SHALL VISIT THE SITE AND DETERMINE THE LOCATION AND THE EXISTENCE OF ALL STRUCTURES AND UTILITIES SHOWN OR NOT ON THE PLANS. BUILDING EXISTING NOTES: 1. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND BE AWARE OF ALL EXISTING CONDITIONS AND INTERFERENCES. 2. THE CONTRACTOR SHALL CHECK CONDITION FOR EXISTING WIRING INSULATION AND NOTIFY THE OWNER, ARCHITECT, OR ENGINEER OF ANY DANGEROUS CONDITIONS. 3. THE CONTRACTOR IS TO COMPLETELY REMOVE AND DISPOSE OF ALL ITEMS AND THAT ARE SO INDICATED ON THE PLANS WITH THE OWNERS APPROVAL. 4. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HAVING VISITED THE SITE AND HAVING FAMILIARIZED HIMSELF WITH ALL EXISTING CONDITIONS. ANY QUESTIONS OR DISCREPANCIES FOUND WITH REGARD TO THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING ENGINEER BEFORE SUBMITTING A PROPOSAL. FIELD MEASURE EXISTING CONDITIONS PRIOR TO FABRICATION OF ALL MATERIALS. 5. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR/INSTALLER. 6. IF MATERIALS, QUANTITIES, STRENGTHS OR SIZES INDICATED BY THE DRAWINGS OR SPECIFICATIONS ARE NOT IN AGREEMENT WITH THESE NOTES, THE BETTER QUALITY AND/OR GREATER QUANTITY, STRENGTH OR SIZE INDICATED, SPECIFIED OR NOTED SHALL BE PROVIDED AND APPROVED BY EOR. Elk SCOPE OF WORK: s SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE: 1. CMU COLUMN REMOVE DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 2. CMU VERTICAL WALL INJECT ALL CRACKS PER PERMIT PLANS AND SPECIFICATIONS 3. CMU VERTICAL WALL DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 4. REMOVE AND RE —INSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS 5. 'INSTALL TRENCH DRAIN PER PLANS 116 I a—! 3p,5 35.5 EA WALL & WALK 1—STOR TT- ,q ISLAND Lb t KEY MAP NOT TO SCALE` 2ND STORY EXISTING WALL RECREATION CENTER 2—STORY BUILDING BASIN j'� LANDING-1 STAIRS BOAT {SASS - DOWN AREA AREA SHOWN) WiT...71301 :CONCRETE N r'� JD�RFD SURVI -lkPAVERS «t_ 7b 71r KIDS ^^^ 4TION WALL - '•': 0 PUMP STATION HOT TUB o1 r.m"Fb SHUFFLE BOARD COURTS (NOT SHOWN) .1 PROJECT LOCATION FILE �// �O COPY ��j �/ r MP- OC.�„N mw IIEVIEWED FOR CODE COMPLIANCE ST. L CIE COUNTY ROCC 7 Gv STRUCTURAL CONSTRUCTION PLANS SHEET S-1 S-1,1 S-2 S-3 DESCRIPTION COVER SHEET, LOCATION MAP, AND GENERAL NOTES GENERAL REPAIR NOTES PROPOSED RESTORATIONS PLAN VIEW PICTURES OF DAMAGE TYPE REG HALL SPA/POOL EAST RETAINING WALL RESTORATIONS NETTLES ISLAND 9801 S. OCEAN DRIVE JENSEN BEACH, FL 34957 f�INEE CIVIL • STRUCTURAL CSM ENGINEERING, LLC 20B SW OCEAN BOULEVARD STUART, FLORIDA 34994 o: 772-220-4601 w: www.CSM—E.net CERTIFICATE OF AUTHORIZATION: 29057 THE ENGINEER HEREBY EXPRESSLY RESERVES HIS/HER COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED, COPIED, OR ASSIGNED TO ANY THIRD PARTY IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF CSM ENGINEERING, LLC. THIS DOCUMENT, THE IDEAS, AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS PROPERTY OF CSM ENGINEERING, LLC AND B NOT TO BE USED, IN WHOLE OR IN PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CSM ENGINEERING, U.C. CSM ENGINEERING, LLC COPYRIGHT C2020 PERMIT SET: 7�20-2020 NOTES & COMMENTS » ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL DIMENSIONS. ALL SCALES INDICATED PERTAIN TO 24"X36" PLOTS 2 3 4 5 DESIGNED BY: CHARLES DARDEN DRAWN BY: JASON THOMASELLI CHECKED BY: CHARLES DARDEN SCALE: AS SOWN PROJECT J: \\``\1\i1lJllp1jA'` m Q�°. V`cENsfi Fey s� No.769T0 - �F STATE OF ORID J/p/fl(18 CHARLES�A DARDEN JR DATE 1 FLORIDA REGISTERED PROFESSIONAL ENGINEER NO 76000 SHEET NAME: COVER SHEET, NOTES, & MAPS SHEET: S-1 GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE & EXISTING FBC 2017; 6TH EDITION AND ASCE 7-10. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE BEFORE CONSTRUCTION HAS BEGUN. ALL OBSERVED DISCREPANCIES SHALL BE REPORTED IMMEDIATELY TO THE ENGINEER. 3. DESIGN LOADS: ALL LOADS ARE EXISTING TO REMAIN; NO NEW LOADING ONLY REPAIRS. 4. CONCRETE: ALL REINFORCED CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", AND ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". ALL CONCRETE REPAIR WORK SHALL BE IN ACCORDANCE WITH ACI "CONCRETE REPAIR MANUAL LATEST EDITION. ACI 311, "RECOMMENDED PRACTICEFOR CONCRETE 'INSPECTION". ACI 347, "RECOMMENDED PRACTICE FOR CONCRETE FORM WORK". ACI 304R, "GUIDE FOR MEASURING, MIXING, AND PLACING CONCRETE". ALL STRENGTHS NOTED BELOW ARE 28-DAY STRENGTHS: IXING AND CONVEYANCE I READY -MIXED CONCRETE SHALL BE MIXED IN ACCORDANCE WITH ACI 304 AND DELIVERED IN ACCORDANCE WITH ASTM C94. SELECT PROPORTIONS FOR NORMAL WEIGHT CONCRETE IN ACCORDANCE WITH ACI` 301. 3. CONCRETE 'SHALL BE CONVEYED FROM MIXER TO PLACE OF FINAL DEPOSIT BY METHODS THAT WILL PREVENT SEPARATION OR LOSS OF MATERIAL. CONVEYING EQUIPMENT SHALL BE CAPABLE OF PROVIDING A SUPPLY OF CONCRETE AT THE SITE OF PLACEMENT WITHOUT SEPARATION OF INGREDIENTS AND WITHOUT INTERRUPTIONS SUFFICIENT TO PERMIT LOSS OF PLASTICITY BETWEEN SUCCESSIVE INCREMENTS. 5. DURING HOT WEATHER, PROPER ATTENTION SHALL BE GIVEN TO INGREDIENTS, PRODUCTION METHODS, HANDLING, 'PLACING, PROTECTION AND CURING TO PREVENT EXCESSIVE CONCRETE TEMPERATURES OR WATER` EVAPORATION THAT MAY IMPAIR REQUIRED STRENGTH OR SERVICEABILITY OF THE MEMBER STRUCTURE. POURED -IN -PLACE STRUCTURAL CONCRETE: 5000 PSI EXTERIOR CONCRETE SHALL HAVE 4% MINIMUM ENTRAINED AIR. CONCRETE REPAIRS SHALL BE PROVIDED FOR THOSE AREAS IDENTIFIED WITH SPALLING, DETERIORATION, AND UNACCEPTABLE CONCRETE. 4a. THE MIX DESIGN SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS 2. REMOVE ALL UNSOUND CONCRETE IN THE AREA OF THE DETERIORATION. REMOVAL SHALL BE PERFORMED WITH SMALL POINTED TOOLS RATHER COMPRESSIVE STRENGTH : 5000 PSI MIN. THAN WIDE CHISEL EDGES TO PREVENT MICRO CRACKING AND CONTINUED SLUMP: 5 TO 7 INCHES SPALLING OF CONCRETE WHICH IS TO REMAIN. AIR CONTENT: 4% TO 6% OPTIONAL WATER/CEMENT RATIO: 0.40 THE AREA OF CONCRETE TO BE REMOVED SHALL EXTEND ALONG THE PUMPABLE PEA -ROCK MIX LENGTH OF THE REINFORCING, BEYOND THE LIMITS OF THE REINFORCING MAX. COARSE AGGREGATE : 3/8" TO 3/4° DETERIORATION A MINIMUM OF 2" INTO SOUND CONCRETE. CORROSION INHIBITOR: 2.5 GALLONS PER CUBIC YARD �I PROVIDE A Y" MINIMUM DEPTH SAW -CUT, PERPENDICULAR OR SLIGHTLY UNDERCUT TO THE CONCRETE SURFACE AT THE LIMITS OF THE REPAIR TO 5. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60. PREVENT FEATHERING OF THE PATCH MATERIAL. DO NOT CUT ANY FOR & REINFORCING, EXCEPT AS ACCEPTED BY THE ENGINEER. TENSION SPLICES: 48 x BAR 0 #3, #4, #5 5. REMOVE ALL RUST AND SCALING OF THE REINFORCING THOROUGHLY BY 6. ALL CONNECTIONS EXPOSED TO WEATHER, OF STEEL TO STEEL AND STEEL SAND 'BLASTING OR WIRE WHEELING TO MASONRY/CONCRETE, MUST BE STAINLESS STEEL` BOLTS. 7. THESE DRAWINGS ARE NOT VALID UNLESS SIGNED AND SEALED WITH AN THOROUGHLY CLEAN THE EXPOSED CONCRETE SURFACE OF ALL TRACES EMBOSSED SEAL OF AN ENGINEER EMPLOYED BY CSM ENGINEERING, LLC OF DIRT, GREASE, OIL, DUST, AND OTHER CONTAMINANTS WHICH MAY ANY CHANGES TO THE DOCUMENTS MUST HAVE THE WRITTEN CONSENT OF PREVENT PROPER BONDING OF THE REPAIR MATERIALS. CSM ENGINEERING, LLC. ALL ORIGINAL DRAWINGS, TRACINGS, AND SPECIFICATIONS MUST BE RETAINED IN THE OFFICES OF CSM 7. THE PREPARED CONCRETE SURFACE SHALL BE SATURATED SURFACE DRY ENGINEERING, LLC AND ARE THE SOLE PROPERTY OF CSM ENGINEERING, iI (SSD), BUT FREE OF STANDING WATER. APPLY A BOND COAT OF SLURRY, LLC. PREPARED WITH THE REPAIR CONCRETE, WITH A STIFF BRISTLE BRUSH COVERING ALL EXPOSED STEEL AND ALL CONCRETE SURFACE AREAS. 8. CSM ENGINEERING, LLC. SHALL BE AFFORDED THE OPPORTUNITY TO PROVIDE CONSTRUCTION OBSERVATION SERVICES DURING THE CONCRETE 8. WHILE SCRUB COAT 1S STILL WET, PLACE REPAIR CONCRETE MIX DESIGN RESTORATIONS AND REPAIR WORK OF THE STRUCTURAL RETAINING WALL. IN ACCORDANCE WITH ACI 301 IN A CONTINUOUS POUR. IN THE EVENT THAT CSM ENGINEERING, LLC. IS NOT RETAINED IN THIS CAPACITY, CSM ENGINEERING, LLC. CAN ASSUME NO RESPONSIBILITY FOR 9. I PERFORM REPAIRS IN ACCORDANCE WITH ICRI GUIDELINE 03730, GUIDE THE CONSTRUCTION DEFECTS FOR THE RECOMMENDATIONS PROVIDED IN THESE FOR SURFACE PREPARATION FOR THE REPAIR OF DETERIORATED DOCUMENTS. CONCRETE RESULTING FROM REINFORCING STEEL CORROSION. 9. ENGINEER SHALL BE NOTIFIED A MINIMUM OF 24 HOURS PRIOR' TO ALL OBSERVATIONS. TYPICAL CONCRETE REPAIR 1. CONCRETE SHALL BE REMOVED USING A 15# CHIPPING HAMMER. 2. WHERE REINFORCEMENT IS EXPOSED BY CONCRETE- REMOVAL,''; EXTRA CAUTION SHALL BE EXERCISED TO AVOID DAMAGING DURING REMOVAL OF ADDITIONAL UNSOUND CONCRETE. 3. IF RUST IS PRESENT ON REINFORCEMENT, ADDITIONAL CONCRETE SHALL BE REMOVED UNTIL CLEAN, SOUND REINFORCEMENT AND CONCRETE IS FOUND AND COVERED WITH "SIKADUR 110, ARMATEK" OR "THOROC ZINC -RICH PRIMER". THIS WILL ONLY' BE DONE AT THE ENGINEERS DIRECTION. 4. UPON REMOVAL OF ALL DAMAGED CONCRETE, AND PRIOR TO STARTING REPAIR, A REVIEW BY THE ENGINEER OF RECORD SHALL BE CONDUCTED. 5. ALL EXPOSED CONCRETE AND STEEL SHALL BE SAND BLASTED CLEAN OR WIRE WHEELED. A ZINC ANODE SHOULD BE INSTALLED TO BARE STEEL. THEN A THIN COAT OF PENETRATING EPDXY SEALER SHALL BE APPLIED OVER THE BARE METAL REINFORCEMENT IMMEDIATELY AFTER SAND BLASTING. 6. THE CUT AREA OF THE CONCRETE SHALL BE CLEAN AND IN THE STATE OF "SSD" (SURFACE SATURATED DRY) PRIOR TO COMMENCEMENT OF PATCHING CURING OF CONCRETE: 11 . ALL REPAIR AREAS SHALL RECEIVE AN APPLICATION OF BURKE "AQUA RESIN" MEMBRANE CURING COMPOUND AFTER FINISHING IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS OR APPROVED EQUAL. 2. ALL CONCRETE SHALL CURE A MINIMUM OF 28 DAYS PRIOR TO APPLICATION OF ANY COATINGS OR FINISHES. 3. AN OBSERVATION SHALL BE CONDUCTED BY THE ENGINEER PRIOR TO APPLICATION OF ANY COATINGS ON THE CONCRETE. ANY CRACKS IN _ THE REPAIR AREAS SHALL BE REPAIRED IN ACCORDANCE WITH THE REQUIREMENTS FOR CRACK REPAIRS. REPAIR OF CRACKS SHALL BE AT NO ADDITIONAL COST TO THE OWNER. REINFORCING R(PLACEMENT: 1. ALL REINFORCING WITH DETERIORATION OF MORE THAN 15% OF THE ORIGINAL BAR DIAMETER, AS DETERMINED BY THE ENGINEER, SHALL BE REPLACED. '. 2. TO PERMIT LAPPING OF THE NEW REINFORCING STEEL, THE CONCRETE, SHALL BE REMOVED ALONG THE LENGTH OF THE REINFORCING, A MINIMUM OF 12" BEYOND THE DETERIORATION INTO SOUND CONCRETE' TO PERMIT SPLICING OF THE REINFORCEMENT. 3. AFTER THE ',REINFORCING HAS BEEN PREPARED, LAP THE NEW REINFORCING BESIDE THE ENTIRE LENGTH OF THE EXPOSED REINFORCING, SECURE IN PLACE WITH WIRE TIES. 4. FOLLOW ALL OTHER PROCEDURES FOR THE CONCRETE REPAIR AS INDICATED. 5. WHERE THE'REMOVAL OF CONCRETE TO ACHIEVE THE REQUIRED LAP LENGTH IS NOT PRACTICAL AS DETERMINED BY THE ENGINEER, BAR DEVELOPMENT CAN BE ACHIEVED BY EMBEDDING THE REINFORCING INTO SOUNDCONCRETE A MINIMUM OF 9" WITH SIKADUR 35, HMLV, A HIGH STRENGTH EPDXY GROUT. 6. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 MINIMUM AND BE GALVANIZED OR EPDXY COATED. TYPICAL SPALLED CONCRETE REPAIR 1, THE CONTRACTOR SHALL LOCATE ALL SPALLS BY S❑UNDING THE CONCRETE SURFACES, USING A HAMMER, UPON L❑CATI❑N OF THE LOOSE CONCRETE A DISTINCT HOLLOW SOUND WILL BE HEARD; THESE AREAS SHALL BE MARKED WITH CHALK OR PAINT BY THE ENGINEER. 2. DELAMINATED, SPALLED, AND UNSOUND CONCRETE AREAS SHALL HAVE THEIR MARKED B❑UNDARIES SAW -CUT TO A MINIMUM OF DEPTH OF 1" INT❑ THE CONCRETE SURFACE. ALL EDGES SHALL BE STRAIGHT AND PATCHED AREAS ARE TO BE AS SQUARE AND RECTANGULAR AS P❑SSIBLE, 3 CONCRETE SHALL BE REMOVED USING A 15# CHIPPING HAMMER, 4, WHERE REINF❑RCEMENT IS EXPOSED BY CONCRETE REMOVAL, EXTRA CAUTION SHALL BE EXERCISED TO AV❑ID DAMAGING DURING REMOVAL OF ADDITI❑NAL UNSOUND CONCRETE, 5. IF RUST IS PRESENT ON REINF❑RCEMENT, ADDITI❑NAL CONCRETE SHALL BE REMOVED UNTIL CLEAN, SOUND REINF❑RCEMENT AND CONCRETE IS FOUND AND COVERED WITH "SIKADUR 110, ARMATEKN, 6, UPON REMOVAL OF ALL DAMAGED CONCRETE, AND PRI❑R TO STARTING REPAIR, A REVIEW BY THE ENGINEER BF RECORD SHALL BE C❑NDUCTE�D, 7, ALL EXPOSED CONCRETE AND STEEL SHALL BE SAND -BLASTED OR WIRE WHEELED CLEAN A ZINC ANODE SHOULD BE INSTALLED TO BARE STEEL, THEN A THIN COAT OF PENETRATING EPDXY SEALER SHALL BE APPLIED OVER THE BARE METAL REINFORCEMENT IMMEDIATELY AFTER SAND -BLASTING OR WIRE WHEELING, 8, THE CUT', AREA OF THE CONCRETE SHALL BE CLEAN AND DRY PRI❑R TO COMMENCEMENT OF PATCHING. 9. REPAIR FOR SPALLS LESS THAN 1 1/2" IN DEPTH: A) THEI,CONCRETE SURFACE AREA SHALL BE COATED WITH B❑NDING OR SIMILAR APPROVED AGENT AND ALLOWED TO COMPLETELY DRY. B) THE SPALLED AREA SHALL THEN BE FILLED WITH "SIKAT❑P 123" AND FINISHED FLUSH WITH THE EXISTING CONCRETE SURFACE. 10, REPAIR FOR SPALLS GREATER THAN 1 1/2" IN DEPTH: A) THE ,FINISH CONCRETE SURFACE AREA SHALL BE SCRATCH COATED W/ '� SIKAT❑P 123 B) APPLY ANOTHER LAYER OF EPDXY GROUT DIRECTLY OVER THE NEW' SURFACE AND FLUSH W/ EXIST. SURFACE, REVIEWED FOR ;ODE COMPLIANCE ST. LUCIE/+COUNTY ROCC REC HALL SPA/POOL EmAST RETAINING WALL RESTORATIONS NETTLES ISLAND 9801 S. OCEAN DRIVE JENSEN BEACH, FL 34957' I aI F ENG I1NEER'IN , CIVIL • $11R;UCIURAI •' MARINE - I CSM ENGINE RING, LLC ( 208 SW OCEAN BOULEVARD G STUART, FLORHCA 34994 o: 772-220-460,) w: www.CSM-E.net CER11RCATE OF AUTHORIZATION: 29057 THE ENGINEER HEREBYD(PRESSLY RESERVES HIS/HER COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED, COPIED, OR ASSIGNED TO ANY THIRD PARTY IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EMPRESS WRITTEN PERMISSION AND CONSENT OF CSM ENGINEERING, LLC. THIS DOCUMENT, THE IDEAS, AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS PROPERTY OF CSM. ENGINEERING, LLC AND IS NOT TO BE USED; IN WHOLE OR iN PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CSM ENGINEERING, LLC. CSM ENGINEERING, LLC COPYRIGHT 02020 R R I 8 NOTES & COMMENTS ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL DIMENSIONS. ALL SCALES INDICATED PERTAIN TO 24M36' PLOTS 1 z 3 4 s DESIGNED BY: CHARLES DARDEN DRAWN BY: JASON THOMASELLI CHECKED BY: CHARLES DARDEN s SCALE: AS SHOWN PROJECT: \1111f111f/YJ \ 1 ,�` �g A DA60'�.,�� y\GENSF ✓y i pp I NO. 76910 I STATE OF niA� 1111111t _ CHARLES A DARDEN JR DATE FLORIDA REGISTERED PROFESSIONAL ENGINEER NO. 76910 SHEET NAME: GENERAL REPAIR NOTES SHEET #: S-1.1 EXISTING CONCRETE HOLLOW CORE AN K SCRATCH COATED FILL WITH "SIKA TOP 123 PLUS`' OR STO PATCH REPAIR MORTAR CR211 EXISTING REBAR/TENDON (TYP.) REPAIR IN ACCORDANCE WITH I.C.R.I. GUIDELINE No. 03730 OVERHEAD SPALLED CONCRETE REPAIR GALVASHIELD XP COLUMN REPAIR INSTALLATION SCALE: NTS NOTES 1. REMOVE DAMAGED CONCRETE AS WITH STANDARD REPAIR METHODS. 2. REPLACE/CLEAN CORRODED REINFORCING STEEL 3. ENSURE ALL EXPOSED STEEL IS SECURELY FASTENED TOGETHER WITH TIE WIRE TO PROVIDE GOOR CONTINUITY 4. ATTACH GALVASHIELD XP ANODES TO CLEAN REINFORCING STEEL AT SPACING OUTLINED IN CONTRACTOR SPECIFICATION. REFER TO GALVASHIED XP DATA SHEET FOR MAXIMUM SPACING GUIDLINES 5. POUR BACK REPAIR AREA WITH MATERIAL AS PER ENGINEER'S SPECIFICATIONS. INJECT CRACK WITH "SIKADUR 35 HI —MOD LV LPL" AS SPECIFIED DRILL J" DIA. HOLES AND INSTALL PORTS AT 8"O.C. ALONG ENTIRE LENGTH OF CRACK SEAL CRACKS AND SECURE PORTS WITH "SIKA HI —MOD GEL" VERTICAL CONIC CRACK REPAIR POUR NEAT MATERIAL (SIKADUR 32 HI -MOD OR APPROVED EQUAL) INTO PRE VEE-NOTCHED CRACK UNTIL CRACK IS COMPLETELY FILLED. / SEAL UNDERSIDE OF SLAB PRIOR TO FILLING IF CRACK REFLECTS THROUGH APPLY CAULK DAM ALONG LENGTH OF CRACK HORIZONTAL GRAVITY CONIC CRACK REPAIR r t EXISTING CMU NEW NP-1 CAULKING EACH RETAINING WALL TO SIDE OF NEW DRAIN REMAIN EXISTING PAVERS TO NEW CONT. REMAIN TRENCH DRAIN Id lo XA ............. .... AIL CONNECT NEW TRENCH DRAIN TO EXISTING PIPE' SYSTEM -CONTRACTOR NOTES: 1. ELECTRICAL & PLUMBING MUST REMAIN OPERATIONAL DURING WORK. DETACH CONDUITS OR PIPING FROM THE WORK AREA AND SUPPORT IN PLACE. CONSTRUCTION MUST BE COMPLETED BY A LICENSED ELECTRICIAN. 2. POOL PUMPS AND HEATERS MUST REMAIN OPERATIONAL DURING CONSTRUCTION. 3. CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS TO SHORE AND PROTECT THE ELECTRICAL, PLUMBING, AND ,POOL PUMP/FILTRATION SYSTEMS. SUBMIT PLAN PRIOR TO COMMENCING WORK. EXISTING POOL DECK WITH TWO SPAS TO REMAIN SOW. SLOPES SOIL SLOPES UP NERE TOP OF DECK 12.42' EXISTING HOT SPA UNIT TO REMAIN INSTALL NEW TRENCH DRAIN PER S-2 & S-3 EXISTING HOT SPA UNIT TO REMAIN EXISTING SOD AREA TO REMAIN L' TOP OF GRADE 6.00' EXISTING EQUIPMENT ALCOVE BLOW REMOVE ELECTRICAL AND PLUM ING AS NECESSARY TO FACILITATE THE EPAIRS EXISTING SOD AREA TO REMAIN EXISTING CMU RETAININ({ WALL TO REMAIN AND BE REPAIRED PER LANS l �— POOL EQUIPMENT LOCATION EXISTING CARPORT ROOF COVERING SUPPORTED BY POST I EXISTING EQUIPMENT ALCOVE BLOW REMOVE ELECTRICAL AND PLUM ING AS NECESSARY TO FACILITATE THE REPAIRS i F/S-3 TOP OF GRADE 6.00' \ REPAIR CMU W/Su S AND CRACKS PER P DSED PLAN VIEW OF REPAIR WORK SCALE: 1/4" = 1'—O" POOL PIPING UNES IN RETAINING WALL T CMU RINING WALL TO REMAIN REPAIR PER PLANS DUSTING SOD AREA M REMAIN REC HALL SPA/POOL EAST RETAINING WALL RESTORATIONS NETTLES ISLAND 9801 S. OCEAN'' DRIVE JENS \ENBEACH, FL 34957 u f E N G I N E E R I N G CIVIL STRUCTURAi. MARINE. CSM ENGINE�ERINGj LLC 208 SW OCEAN BOULEVARD N STUART, FLORIDA 34994 o: 772-220-4601 w: www.CSM—E.net CERTIFICATE OF AUTHORIZATION: 29057 THE ENGINEER HEREBY EXPRESSLY RESERVES HIS/HER COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS. THESE PLANS AND DRAWINGS ARE NOT TO BE w REPRODUCED, CHANGED, COPIED, OR ASSIGNED TO ANY THIRD PARTY IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF CSM ENGINEERING, LLC. THIS DOCUMENT, THE IDEAS, AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS PROPERTY OF CSM ENGINEERING, LLC AND IS NOT TO BE USED, IN WHOLE OR IN PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CSM ENGINEERING, LLC. CSM ENGINEERING, LLC COPYRIGHT �02020 ii Ii I H y u s VIEWED FOR COD COMPLI4NCE ST. LUCIE C06NWY BOCC I NOTES & COMMENTS ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR.I THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL DIMENSIONS. ALL SCALES INDICATED PERTAIN TO 24X36" PLOTS 1 2 3 4 5 DESIGNED BY: CHARLES DARDEN DRAWN BY: JASON THOMASELLI (CHECKED BY: CHARLES DARDEN SCALE AS SHOWN PROJECT III: Iltttlfill/e 6 8 v\cews�r F� No. 76910 =_ *' 4tja STATE OF JI I\\\ —_... CHARLES A DARbEN JR DATE FLORIDA REGISTERED P OFESSIONAL ENGINEER Id6: ?8Si0 SHEEP NAME RETAINING WALL REPAIR PLAN cl W/ DETA! S-2 EQUIPMENT ALCOVE - A SCOPE OF WORK: COLUMN AND OVERHEAD. REPAIR SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE: 1. REMOVE EXISTING PLYWOOD FORM WORK THAT WAS LEFT IN -PLACE 2. ENGINEER TO INSPECT CONCRETE FOR DAMAGE 3. SHORE AS REQUIRED BY ENGINEER 4. REPAIR SLAB AS OVERHEAD REPAIR PER PERMIT PLANS AND SPECIFICATIONS 5. REMOVE AND RE -INSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS Z XTERIOR FACE OF RETAINING WALL SCOPE OF WORK: COLUMN AND OVERHEAD REPAIR SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE: 1. CMU VERTICAL WALL INJECT ALL CRACKS PER PERMIT PLANS AND SPECIFICATIONS 2. CMU VERTICAL WALL DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 3. REMOVE AND RE -INSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS EQUIPMENT ALCOVE CORNER CMU COLUMN - E SCOPE OF WORK: COLUMN AND OVERHEAD REPAIR SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE: 1. CMU VERTICAL WALL INJECT ALL CRACKS PER PERMIT PLANS AND SPECIFICATIONS 2. CMU VERTICAL CORNER REMOVE DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 3. REMOVE AND RE -INSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS 4. SHORE AS REQUIRED BY ENGINEER SCOPE OF WORK: SELECTIVE REPAIRS TO At 1. REMOVE EXISTING 2. ENGINEER TO INSP 3. SHORE AS REQUIRI 4. REPAIR SLAB AS C 5. REMOVE AND RE-1 EQUIPMENT ALCOVE - B COLUMN AND OVERHEAD 'REPAIR XISTING RETAINING WALL TO INCLUDE: WOOD FORM WORK THAT WAS LEFT IN -PLACE CONCRETE FOR DAMAGE BY:; ENGINEER KAD REPAIR PER PERMIT PLANS AND SPECIFICATIONS ALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS EQUIPMENT ALCOVE OPENING LEDGER - D down( SCOPE OF WORK: COLUMN. AND OVERHEAD REPAIR - for poi Zurn 1 SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE: 41ndir 1. CMU VERTICAL WALL INJECT ALL CRACKS PER -PERMIT PLANS AND SPECIFICATIONS Grade decal- 2. CMU VERTICAL WALL DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 3. REMOVE AND RE -INSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS and 1- sq. mn 4. SHORE AS REQUIRED BY ENGINEER enwrifi EQUIPMEN MU COLUMN - F SCOPE OF WORK: SELECTIVE REPAIRS TO AN EXISTING RETAINING WALL TO INCLUDE; 1. CMU VERTICAL WALL INJECT ALL CRACKS PER PERMIT PLANS AND SPECIFICATIONS 2. CMU VERTICAL CORNER REMOVE DAMAGED CONCRETE AND REPLACE PER PERMIT PLANS AND SPECIFICATIONS 3. REMOVE AND REINSTALL ANY ELECTRICAL AND/OR PLUMBING NECESSARY TO PERFORM THE REPAIRS 4. SHORE AS REQUI10 BY ENGINEER ' 1, RA -1 SPEGIFICA110N SHEET r 12[305] WIDE THROAT TRENCH DRAIN SYSTEM TAG Dimensional Data (inches and:[ mm 1) are Subject to Manufacturing Tolerances and Change Without (Notice SPECIFYINGCOENGINEER £' fEEPIT AND P017 CONCRETE EPJ0.,4SEMfF[tT tUdf) RE1NFQRCING BASED UPON APPLICATION AND LOCAL CCCES z' _5O5J 17 [40321 v [102I MIN, 12 [3ti5] a Mu e THILhN - to be tau 1��1"'I + Aewaf111gh UensLiV PalyethVlsne ctie�iirelle���glhi§&;5�2L�B"9jiq allrsVifioY q�reriap, with f-ahii4fachsdttia fsog`th iS Bd4F2 f$]wiih the ekcep¢on of P N 120*a-,U 12`Jj of) fvaal and have a 1211[365mml water absorbent High Density connection between channel per ASTM standard AWS DIA. Frames shall be produced in the USA; PREFIX Z 8O [2032] High 0enslty Polyethylene Channel, Heavy -Duty Frame with Anchor Studs* SUFFIX OPTIONS (Check/specify appropriate options): da Gers F Closed End Cap -U44 4 (102] No -Hub Bottom Outlet T ,1Hub E4 4 [10211 End Outlet _ -U6 6 [1521 No -Hub Bottom Outet 'E6 611621 No -Hub End Outlet -U8 8 [203] No -Hub Bottom Outlet _ -E8 812031 No,HUb End Outlet _-U12 12[3051 No- Hub Outlet _E10 10 [2641 No -Hub Outlet _ -BDF Blade Aci -DCC Ductile In -DCF Ductile In _ -DGC Ductile In -DGF Ductile In vw GDC Gs ize _-GDF G,alvaI 401 FLberglas -GHPD GdvanW _-HPD Heel -Pro( -SBG Stainless DGC-USA Ductile Iron DGF-USA: Ductile Iron -DADA-USA Galvanized o5c-USA Galvanized -GDF-USA, Galvanized g1tudhial Ductile Iron Grate - Class G ictile Iron Grate.- Class C: Class C G ate - Class C ate-Clas's F )A Slotted Grate - Class C sited Grate - Class G Ated Grate - Glass P' Zurn Industries, LLC I Specification Drainage Operation _ 1801 Pittsburgh Avenue, Erie, PA'. U.S.A. I6S62 Ph. 855-663-9876, Fax 914-454-7929 In Canada I Zutn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 - Ph. 908-405-8272, Fax 905-405-1292 wwV&zU§ n.ast THE Trench DGC-USA Ductile Iron DGF-USA: Ductile Iron -DADA-USA Galvanized o5c-USA Galvanized -GDF-USA, Galvanized g1tudhial Ductile Iron Grate - Class G ictile Iron Grate.- Class C: Class C G ate - Class C ate-Clas's F )A Slotted Grate - Class C sited Grate - Class G Ated Grate - Glass P' Zurn Industries, LLC I Specification Drainage Operation _ 1801 Pittsburgh Avenue, Erie, PA'. U.S.A. I6S62 Ph. 855-663-9876, Fax 914-454-7929 In Canada I Zutn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 - Ph. 908-405-8272, Fax 905-405-1292 wwV&zU§ n.ast THE Trench 'A' FIoW Miscellaneous Options -RC Rebar Clips (Set of 2) - _VP Vandal -Proof Lockdown MADE In the U,S.11. Mlscallaneoust)otions _ -CBF Black Acid Resistant Co ted Frarne -DB Bottom Dome Strainer � '=HDS Tye 304 Stainless Steel'Top Frame Regularly furnished unless otherwise specifi Rev. T Gate: 1012612017 G.N. No, 1,39096 Prod, I Dwg, No. Z874-1 2 ECIFICATION APPROVAL REC HALL SPA/POOL EAST RETAINING WALL RESTORATIONS NETTLES ISLAND 9801 S. OCEAN DRIVE I JENSEN BEACH, FL 34957 E N GI N E CIVIL • STRUCTU CSM ENGINEERING, LLC 208 SW OCEAN BOULEVARD STUART, FLORIDA 34994 a 772-220-4601 w: www.CSM-E.net CERTIFICATE OF AUTHORIZATION: 29057 THE ENGINEER HEREBY EXPRESSLY RESERVES HIS/HER COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS. THESE PLANS AND DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED, COPIED, OR ASSIGNED TO ANY THIRD PARTY IN ANY FORM OR MANNER WHATSOEVER WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF CSM ENGINEERING, U.C. THIS DOCUMENT, THE IDEAS, AND DESIGNS INCORPORATED HEREIN, AS AN ;rISTRUMENT OF PROFESSIONAL SERVICE, IS PROPERTY OF CSM ENGINEERING, LLC AND IS NOT TO BE USED, IN WHOLE OR IN PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CSM ENGINEERING, LLC. CSM ENGINEERING, LLC COPYRIGHT o2020 -- t i �i y� N f�f i i xv�rr NOTES & COMMENTS ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL DIMENSIONS. ALL SCALES INDICATED PERTAIN TO 24-X36' PLOTS 2 4 5 DESIGNED BY: CHARLES DARDEN .DRAWN BY: 'JASON nOnASELci .CHECKED BY: CHARLES DARDEN SCALE: AS SHOWN PROJECT: 7, No.76910 _ I = -; �pf'''- STATE OF C(/41 lr r �* f�k /sZSZ0NALCLL-A - CHARLES A DARDEN JR DATF'a FLORIDA REGISTERED PROFESSIONAL ENGINEER RU. i Min MEET NAME: ' PHOTOS OF DAMAGE TYPE SHEL) il" S-3