Loading...
HomeMy WebLinkAboutEvaluation Report; CertainTeed Asphalt Roofing ShinglesEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OTRINITYIERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-1118 1400 Union Meeting Road FL5444-117 Blue Bell, PA 19422 Date of Issuance: 09/22/2005 Revision 8: 05/05/2014 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code. DESCRIPTION: CertainTeed Asphalt Roofing Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, • P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 05/05/2014 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. QOTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category; Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roofing Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the'following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.5, R905.2.4 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 3. REFERENCES: Entity UL (TST 1740) UL (TST 1740) UL (TST 1740) UL( TST 1740) UL (TST.1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL LLC (TST 9628) UL LLC (TST 9628) UL LLC (TST 9628) UL LLC (QUA 9625) Property Standard Year Physical Properties ASTM D3462 2007 Wind Resistance ASTM D3161, Class F 2006 Wind Resistance ASTM D7158, Class H 2O07 Examination Reference Date ASTM D3161 94NK9632 05/15/1998 ASTM D3161 99NK26506 11/23/1999 ASTM D3161 03CA12702 05/27/2003 ASTM D3161 03CA12702. 06/16/2003 ASTM D3161 .03NK29847 10/03/2003 ASTM D3161 04CA11329 05/24/2004 ASTM D3161 04CA32986 12/03/2004 ASTM D3161 OSNK07049 04/15/2005 ASTM D3161 OSNK16778 05/12/2005 ASTM D3161 OSCA16778 05/12/2005 ASTM D3161 05NK14836 05/22/2005 ASTM D3161 OSNK22800 06/22/2005 ASTM D3462 R684 09/21/2005 ASTM D7158 05NK08037 06/28/2006 ASTM D3161 & D3462 09CA28873 07/23/2009 ASTM D3462 IOCA41303 10/07/2010 ASTM D3161 10CA41303 10/08/2010 ASTM D7158 10CA41303 10/27/2010 ASTM D3161 & D3462 10CA44960 11/11/2010 ASTM D3161, D3462 & D7158 13CA32897 11/21/2013 ASTM D3161, D3462 TFWZ.R684 04/22/2014 ASTM D7158 TGAH.R684 04/22/2014 Quality Control Service Confirmation Exp. 02/13/2016 Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 Certificate of Authorization #9503 FL5444-R7 Revision 8: 05/05/2014 Page 2 of 11 C�D ,,! I KINITY I ERD 4. PRODUCT DESCRIPTION: 4.1 CT201-, XTTM 25, XTTM 30 and XTTM 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Carriage House Shangle@, Centennial Slate TM, Grand Manor Shangle@, Landmark TM, Landmark TM IR, LandmarkTM Pro, Landmark TM Premium, LandmarkTM TL, Landmark TM Solaris and Landmark TM Solaris IR are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Presidential Shake TM, Presidential Shake TM IR and Presidential Shake TLTM are fiberglass reinforced, architectural asphalt roof shingles. 4.4 HatterasTM, Highland SlateTM and Highland Slate TM IR are fiberglass reinforced, 4-tab asphalt roof shingles. 4.5 PatriotTM is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a .laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.6 Presidential Accessory, Accessory for Hatteras, Shangle RidgeTM, Shadow Ridge TM, Cedar CrestTM and Cedar CrestTM IR are fiberglass reinforced accessory shingles for hip and ridge installation. 4.7 Any of the above listed shingles may be produced in AR (algae resistant) versions. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All shingles • noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge and Cedar Crest hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F when BASF Sonolastic.NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, indicating the shingles are acceptable for, us in all wind zones up to Vasd = 150 mph (V,it = 194 mph). 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the CertainTeed asphalt roofing shingles listed in Section 4.1 through 4.5 exceeds the calculated uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (V„it = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local, jurisdiction, which shall take precedence. 5.4 All products in the roof assembly shall have quality assurance audits in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-R7 Revision 8: 05/05/2014 Page 3 of 11 6. -0 'fit I KINOI'YIERD INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 6.2 6.2.1 6.2.2 6.3 6.3.1 IMMM Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions. CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1510 and CertainTeed published installation instructions. CT20TM. XTTM 25, XTTM 30r XTTM 30 IR: 0VAND STANDARD SLOPE ENGLISH t2" 12" 12" r.1'(25mm) Sealant 1"(25mm) (1A5 rums 5: j1p4 for 1darfood Flapt 1AEUK 13Va" 131/V —. + 131N. ►{ -}- (�1"(25mm) Sealant '1"(25mn)- 1 6 V•a" T Rgare11-3: Usefb-na&,forezzwyfrdi'sbMgls Hip & Ridge: Cut Shingles (25arnrp�l t-'�n t� � t!t }i"C f— ---—-—— — — — —i 12" Cap Cap Cap (3A5lmm) Shingle Shingle Shingle —1 Figure ll-2d: Cut tabs, then trin)-backto malreeap sbin& (Englisb dhneosums Awn). STEEP SLOPE Use. -four n.dls and six spots of asph4t roofing cement for every fall shingle (Figure 11-4). Asphalt roofing cement meeting ASTM D4586 Type 11 is suggested. ---- -- --- to Rooting Cement Apply 1" (25 ntrn) spols of asphalt roofing cement under each tab corner. Figrar 11-4. Use four n0v and stx sPoks:gfaspfirillaatmnl on.stecgislo* 'CAUTION: Excessive use of roofing cement can cause shingles to blister. god .` Ts �``�� 2�NoNyooaP�ar1 Figure 11-?5: lnstrrllatlorr of gips along dbe4lps 4nd ridges. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant, in accordance with manufacturer's instructions. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 CertiFcate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 4 of 11 6.3.2 Carriage House ShancileM, Centennial Slater"' and Grand Manor Shancilen: LOW..AND STANDARD SLOPE, (1461vi nails for every Ad! Sliafi&- 1" . —V } i• C257 I i�5 rn) Sj8" 65/6" 00.01m) (Vat") Figure 174, Cse flee nails for etugn full Crand,41anorSbanble, Crariage. Home Aingk; or Conleirrelid Slate. 6.3.2.1 Hip & Ridge: Shangle® Ridge STEEP SLOPE Use seven mills and diree spots of aspliall roofing cement. for every fill Grand ,Manor Shingle. Use five naffs and three spots of asphalt roofing cement for evtiry full Larrdage lfolnse Shingle and Gcalenalaf Slale.:ipply usphalt roofing cement 1• (25 mm) from edge of shingle (Figure 17-5). Uph:dt roofing ceffient nteeldng:1ST11 W586 7t'pe 11 Ls mggested. Foim174.,i en installing GranildlanorSGnrrgWsonsleep sialm, ave seven nafle and ttnee spots ofaspbar roojlt+g conmit. ,r__ 12• � 18' Exposure Remove tape from the right side 1. ; g•� and fasten SECOND Fasten the Remove left side's 851a. RIGHT Ttds cape FIRST LEFT Figure 17-19. Installation ofShangleO Ridge shingles Flgtlrir 17-.18: Shenigleo Ridge. on bqu and ridges. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. Exterior Research and Design, L.L.C. Evaluation Report 3532.09.05-118 Certiricate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 5 of 11 QOTRINITYIERD 6.3.3 LandmarkTM Landmark'" IR LandmarkT" Pro (formerly Landmark'"" Plus), LandmarkTI Premium LandmarkTm TL, Landmark TM Solaris, Landmark TM Solaris IR: lONi AND STANDARD SLOPE LANDMARK n 13'/1' 13" 13t/2" METRIC DIMENSIONS 1---(343 mm)-! +-(334 mm)-► (343 mm}-c) t2" 1014" 12" I.•-1" (25 mm) 1" (25 mrt) +I • �+-(305 mm)-►-*-(375 mm)--"--(305 mm)-►{ _ � •xx�,�rx..xvz�s�:c�r> 1"(25mm): Release Tape 1'(25rnht)- 11_ Natlable_ 4 Frger,r 73••t. l sefory nvrtsfor erer7fillf st ingte. Atea STEEP, SLOPE Usesi:X nails and four. spots of asphalt roofing cement for even full lag) WA.ed shingle:. See below. Asphalt roofing cement should meet ARM N5011rpe If. Apply 1" spots of asphalt roofing cement ande each corner and at about 121, to 13 m from each edge. METRIC DIMENSIONS. �-10/4" '12"—► . (305 niin) (375 mm) (305 mm) fie lease Tape hlArea� __ —� rc Sleepy (25.mm) ----- # (25mm, 6.3.3.1 Hip.& Ridge, Option 1: Shadow RidgeT"' Ftgrgnl,�:16.• SGarlou�ltfdga accswory sGtngles datrtcG erasilvJiom Ibme- kxunitstomake72fnelividwdca/)Plecar. 12" (305mm) {15amm) (150mm) Z" \ f T ,into) Notches for Alignimnt to the Top Edge POW Previous T top for 5" (125mm) Exposure (18oIn _.__! English Dimension Exterior Research and Design, LLC. Certificate of Authorization #9503 LANDMARK IL —131/2" '- 13"—«.--13't.' (343 m t) ( mm) (343 nm) 1"(25mm)-►i Rvtnr t3 S' aso so nails ulna!four spols of asphalt nwfing maamt Orr sleep stapca 97/r (125mm) I (125mm) Notch for. Centering itq^ mm) Notches forAlignment to 5 the Top Edge of the Previous 7 Capfor5W(141mm).Ex. sure (1m m) Metric Dimension Evaluation Report 3532.09.05-118 FL5444-R7 Revision 8: 05/05/2014 Page 6 of 11 ,2" ✓ (305rt��T) Laying Notch i/' I I PigrffaJj 2o. Use livingnolches k ce.nlar ihftr glen on hips and ridges,.andto locate the coiml exposure. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0 Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.3.2 Hip & Ridge, Option 2: Cedar CrestTM, Cedar CrestTM IR Use two fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp Polyurethane Roof & Flashing Sealant to hand -seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line 3/4 to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing tab sides into the adhesive, and install nails. To secure the other side, apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Nae�+.Raing arfr�4ve �(102naml t• Oabotasplsa0. j catderAWK0en & laygrs ( 1 shin25, of Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 7 of 11 6.3.4 6.3.4.1 F_YD \-J TRINITY JERD Presidential ShakeTM, Presidential ShakeT1 IR, Presidential Shake TLTM: LOW AND STANDARD SLOPE: For lOw�and standard slopes, use flit nails for each fail Presidential shlilgle;as shown below. Neilln' �.-- 40" --� GuIAe tines (1.016. mm) 5:1L4„ —7— (133)timi • • 14114" 1 ]2' 3A tnmy (362 mm) NOTE: AppIV nails on painted guideline. Figure.(&6 Fastening Presidential.and PreskWalTLSbalm Absgla on low mid standard slopes Hip & Ridge, Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY STEEP SLOPE: For steep slopes, use nine nails for each fail Presidential shingle and apply 1' diameter spots of asphalt roofing cement under eactt.sldngle tab. After opplying'5 nails In between the nailing guide lines, apply: d nails f' above. tab cutouts making certaln Llbs.of overlying shingle cover nails. } T 1' diameter asphalt rooting cement Figure i6.7. Fastening Presklend'al and Presidential T/L Sbake sbingles on steep slopes. Ptesidential. accessory shingles can be used for covering hips and rdges: Applyshingles up to the ridge (expose no more than 7" from Elie bottcm edge of the "tooth." Fasten each accessory-W1 two fas- teners. The fasteners.must be '04" long or longer, so they penetrate elti a 3�T' into the deck or completely through the deck. Presidential a. Ccessoly.comes in two different sizes: Accessory produced in Mrmingham, AL,is 12" x 12"; Portland, OR produces 97/8 x 1341" accessory.. Note: For ASTM D3161. - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.4.2 Hip & Ridge, Option 2: Refer to instructions herein for Cedar CreStTM, Cedar CrestTM IR hip and ridge shingles. 6.3.5 HatteraSTM: LOW; -STANDARD AND STEEP -SLOPE: figure IS,-;P f'ImIning !rn/lerns Sbiuglrs on .LoreandSlandaI Sio/rev Por.low aads(on6rd slopes, use fire Indls for Led, full u;weru shingles shown above. Exterior Research and Design, LLC. Certificate of Authorization #9503 Ngum 154: %nrenirig dnJte>.+s Sbiugles an UMP Slopes ror sicep st eNs, use fie nabs and eight spas of asplinll roofing cemem for eack lull ttAuem Shingle as shown above Apply I` (23huu) diameter aln*s ofrongng cemem WS7811) W61ype 11 sug,pc$av0 under.+ml+ lab Comet PrLKs shingle bile phire: da 1101 espose conical. GiuTION: Toonuirh roofing cemem cm anise shingtes to blister. Evaluation Report 3532.09.05-118 FL5444-R7 Revision 8: 05/05/2014 Page 8 of 11 6.3.5.1 Hip & Ridge, Option 1: Accessory for Hatteras i i �., r., .............:>:.. ... 2 3 Ftgura 13-14 18 tf>rce pieca. unifs sepanite to make `547fatferasAaessory sfifngles, Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.5.2 Hip & Ridge, Option 2: Cut Hatteras Shingles Easier 8' 18' (460 mm) go\� (203 mrm 1nl aeS cal Cap. Cap Cap Shingle Shingle Shingle Shingle Zaon` Aprs l5-'2O.,:Cut liatleras sbdngfes to make cover cap. Figure 15-21: Installation of caps along baps and HdRes. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0 Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 9 of 11 6.3.6 Highland Slate'"', Highland Slate"' IR: [OVtf ANDSTAIfDAR.D SLOPE: F19=04M.,1L+`o FIPW naik; for every HFgUm d Slate sbingkr (-)0 rt 1 RINI7YIERD STEEP SLOPE: Use FnTi nails and EIGHT spots of asphalt roofing cement' for each fill Inghland Slate shingle, For Mtamf-Dade, SLY naffs are required. Apply I' diameter spots of asphalt roofing cement under each tab corner. Asphalt roofingcement meeting ASI:M D4586 Ve Ills suggested Figure I13& Erse Fm=* and eigbi Spais ofaspball rooft cenveil cinder each tab corner. CAUTION:: Excessive,use;otroofing cement can cause shingles to blister. 6.3.6.1 Hip & Ridge, Option 1: Refer to instructions herein for Cedar CrestTM' Cedar CrestTM IR or Shangle RidgeTm hip and ridge shingles. 6.3.7 PatriotTp1: LOW AND STANDARD SLOPE Use YOUR nails for erety full shingle located as shown helot. S�aWnt (25me 1 F i P(25ar1 (t min) t l— 13tio' ►� 13f,8' ►�• lzfl3 +� (333mm; (333 vr) (Sao STEEP SLOPE Use M R nails and four spots of asph:dt rooting cement for every full shingle as shown below. Asphalt roofing cement meeting ASfM D4586 I4pe.I1 is suggested Apply 1'(25 min) spots of asph:dt roofing cement as shown. CALMON: Excessive use of roofing cement can cause shingles to blister. �.. 3amj - — — — — — i'p5c�'F^' 9-VY I (156-1 1 • ^ J C Reafinp Cement --j— t133W; - .tmni'i Hip & Ridge: Refer to instructions herein for Cedar CrestTM, Cedar CrestTM IR, Shadow Ridge TM or Shangle RidgeTm hip and ridge shingles. Exterior Research and Design, L.L.C. Certificate of Authorization #9503 Evaluation Report 3532.09.05-118 FL5444-R7 Revision 8: 05/05/2014 Page 10 of 11 `�1T�NrrYIERD 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by theBuilding Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC - QUA9625; (414) 248-6409; karen.buchmann@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 11 of 11 EXTERIOR RESEARCH & DESIGN, LLC. �y Certificate of Authorization #9503 TRIM 1 1 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-118 1400 Union Meeting Road FL5444-117 Blue Bell, PA 19422 Date of Issuance: 09/22/2005 Revision 8: 05/05/2014 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of Construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code. DESCRIPTION: CertainTeed Asphalt Roofing Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality. Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by:. Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on OS/OS/2014 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product. C"YD '� 1 KINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roofing Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.5, R905.2.4 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 3. REFERENCES: Entity UL (TST 1740) UL (TST 1740 ) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740 ) UL (TST 1740) UL LLC (TST 9628) UL LLC (TST 9628) UL LLC (TST 9628) UL LLC (QUA 9625) Property Standard Year Physical Properties ASTM D3462 2007 Wind Resistance ASTM D3161, Class F 2006 Wind Resistance ASTM D7158, Class H 2O07 Examination Reference Date ASTM D3161 94NK9632 05/15/1998 ASTM D3161 99NK26506 11/23/1999 ASTM D3161 03CA12702 05/27/2003 ASTM D3161 03CA12702 06/16/2003 ASTM D3161 03NK29847 10/03/2003 ASTM D3161 04CA11329 05/24/2004 ASTM D3161 04CA32986 12/03/2004 ASTM D3161 OSNK07049 04/15/2005 ASTM D3161 05NK16778' 05/12/2005 ASTM D3161 05CA16778 05/12/2005 ASTM D3161 05NK14836 05/22/2005 ASTM D3161 OSNK22800 06/22/2005 ASTM D3462 R684 09/21/2005 ASTM D7158 05NK08037 06/28/2006 ASTM D3161 & D3462 09CA28873 07/23/2009 ASTM D3462 10CA41303 10/07/2010 ASTM D3161 IOCA41303 10/08/2010 ASTM D7158 IOCA41303 10/27/2010 ASTM D3161 & D3462 10CA44960 11/11/2010 ASTM D3161, D3462 & D7158 13CA32897 11/21/2013 ASTM D3161,D3462 TFWZ.R684 04/22/2014 ASTM D7158 TGAH.R684 04/22/2014 Quality Control Service Confirmation Exp. 02/13/2016 Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-R7 Revision 8: 05/05/2014 Page 2 of 11 4. C_"�D TRINITY' I ERD PRODUCT DESCRIPTION: vT 4.1 CT20TM, )CrTM 25, XTT- 30 and XTT" 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 CarriageHouse Shangle@, Centennial Slate TM Grand Manor Shangle@, Landmark T"', Landmark TM IR, Landmark TM Pro, Landmark TM Premium, LandmarkT"' TL, Landmark TM Solaris and LandmarkT"' Solaris IR are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Presidential Shake TM, Presidential Shake TM IR and Presidential Shake TLT`" are fiberglass reinforced, architectural asphalt roof shingles. 4.4 HatterasTM, Highland SlateTm and Highland Slate TM IR are fiberglass reinforced, 4-tab asphalt roof shingles. 4.5 PatriotTP9 is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.6 Presidential Accessory, Accessory for Hatteras, Shangle Ridge TM, Shadow RidgeT°°, Cedar CrestTm and Cedar Cre8tTM IR are fiberglass reinforced accessory shingles for hip and ridge installation. 4.7 Any of the above listed shingles may be produced in AR (algae resistant) versions. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM.D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge and Cedar Crest hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F when BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, indicating the shingles are acceptable for us in all wind zones up to"Vasd = 150 mph (V„it = 194 mph). 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the CertainTeed asphalt roofing shingles listed in Section 4.1 through 4.5 exceeds the calculated uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (V,,,t = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction, which shall take precedence. 5.4. All products in the roof assembly shall have quality assurance audits in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 3 of 11 TRINITY I ERD 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions. 6.3 CertainTeed asphalt shingles are acceptable for. use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1510 and CertainTeed published installation instructions. 6.3.1 CT20Tm,_XTTM 25, XTT"' 30• XTT'" 30 IR: LOW AAD STANDARD SLOPE ENGLISH' ?" 12" 12" 4—(l05 mm} _(305 mm)(305 mm) jr-1"(25 ttti) — fart 1^(25mm}=�y 531a`'(1A5mni) 1 — J 5vi!*r'Nohvood Plant: METRIC f31le"L(25 '"(25To). ealant silt, T Fygrore ll 3: Usa%ournaiG for eiary J4dl sbtngle 6.3.1.1 Hip & Ridge: Cut Shingles (251mmI� I I 2 (fin) rRemove� ' Cap Cap, Cap 3051mm) Shingle shingle Shingle 1 ,%tira ii-2 . Cnhtabs !lrert'h*f back to moko cap sbingles (A`nglfsb Anmsfons.sbamn). ;STEEP SLOPE. Use four ntdls mid six spots of asphalt roofing cement" for every full shingle (Pigiire-ll-d). Asphali roofing cement iffeetingASTM D4586 ape II Is suggested. I� Rooting Cement Apply 1" (25 mm) Spols of aephall roofing cement under each tab comer. Ffgum If-4: Usafour naffs and itxspoksgfnsp&a' t6aMl on sleep, ikp cAUTIOmExcessive use of roofing cement.can.cause shingles. ib blister. _12'.(305'mm) (t25:mm) % �ys�aes _ �l`5��2 totN°NioodP Fire 11-25: In5tn(!4t/on of cups along & bips:t nd rtdl -. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp Polyurethane Roof & Flashing Sealant, in accordance with manufacturer's instructions. Exterior Research and Design, LL•C. Certifcate of Authorization #9503 Evaluation Report 3532.09.05-RS FL5444-R7 Revision S: 05/05/2014 Page 4of11 (-)o ,.! I RINITYIeitD 6.3.2 Carriage House Shan4le@, Centennial Slate"" and Grand Manor Shangle®: !t)W:AND ST6EP:SLOPE STANDARD SLOPE tie eeven ua}Is and d4w spots orwu 1i4kiaoinicc.00 ror ever} Gse l?vc:natls fuiwcry hitShadgTe. Iu1t Grand�lunor Shia L'sc ftre nailssnd lLree specs o(aspl��lt moGgs cement for Cvcty 6�11 Larnure house Sltmgie aari .Gemenntal fto.-Ali .asptrab rooting Cement 1' (25. min) from edge of sidn;ie (Figriia 77=5�. Asniullt rw1%cement meeflag iST.M Q?>SG T}Pe 11 T" �I is61198istcd. {25 rtpn) (25 rm) mm) 5(8T{ 'or {16.rnmj (T2iltnnV 4 1 p• I—t25mm}. tzsm �i Rom 174., Wfitr nWh fnr'iavo-fill Grand,ifariorSLmgle, 0o'riage llouse StrmiRk _ or Cenlew&l Sfak 6.3.2.1 Hip & Ridge: Shangle0 Ridge Figure 17:1.5: Sbasrgle Ridge.. Flytre 175: 1ptrn inslrrUing.Grwrd Alannr;SGgnRtes nnsteep ilalrrs ovsei•vis nalrsavi 1lncespoisoas? P41 roaJing crinerrJ. EXposure Remove tape from the right. side i ;, g• and fasten j �SECOND Fasten the .� leftsitle� $5�g RIGHT FIRST LEFT Flgum 17.19:.Insfaffelioll ofSbnnglen Ridge shingles on b1psakd iIdges Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. Exterior Research and Design, L.L.C. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 5of11 ,rTRINITYIERD 6.3.3 LandmarkT'" Landrriark"m IR LandmarkTM Pro (formerly LandmarkTM Plus). Landmark""' Premium LandmarkTm TL. Landmark' Solaris, LandmarkTM Solaris IR: LOW AND STANDARD SLOPE tANDmARK n METRIC DIMENSIONS 12 1.4'14„ 121. �-(30.5inm)=-+($75mm)-� (3p5mm)-•{ ICI"(25mm) :Releas%Tape 1'•(25mm)�I •- 11/z Naila6fa� . Atea STEEP SLOPE Ease six: nails. and Four spots of.aspba(t roofing cement forewiy full laminatedshingle. See. belo%e.ASpJ1dL,raol1ng cerno should meet ASTSf 0445% 1),pe lt. Apply 1 ':sjtats ofasp,kropflug cement rind:.( each cocoernnd.:it:nhold 12":ro'13" in h'oin each edge; METRIC.Ii1MENSIONS 6.3.3.1 Hip & Ridge, Option 1: Shadow Ridge TM Plgure 1-16 S6q�loiaRtdgQ nccessv "s.Linles.datnelr easlfyfrorn. tb1xv-piax units. to nrnke,72individ[a+l cap pferes. j305mm) —1 i (159mm} I (15i1mm). Not h for Centering (305inm) Notches forAfignmehttq' the Top Edge of tho Pre .oils r Captor5':(i4rnm)Expasure (18gmm) t EngIbb Dimension 131le 13" 13W, (•—(343 mm0 mm)—► --(3d3 mm)—+ql L-1"{25 mm) I 1" (25 mm)--i -- Figure i31: tsefuiir nnilsfor eroy fidl shig4e LANDMARK TL {343 (nit) ,(330RIM ) (343 min) i rl a ' �—�••Ranliny Cemem figirm l,?d? trsii six na k and friar spols of -Pballroofing wnenron wopsleixec Or (125mm). I 1125mm) Notch for Centering IotchesIorAlignment to 3. 'Top Eoge of the. 'Prev ious (196mm) for55i$" (141 mm) txpo's Metric Dimension Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 Certificate of Authorization #9503 F11-5444-1117 Revision .8: 05/05/2014 Page 6 of 11 QOTRINITYIERD (3otn�— Laying Notch I I °•� I A rme13� 20.• Use Gsylitgnok&e beenters6Tngleson hips and ridges, ani to locatotGawrrectexpasara Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.3.2 Hip & Ridge, Option 2: Cedar CrestTM, Cedar CrestTM IR Use two fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant to hand -seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line 3/4 to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing tab sides into the adhesive, and install nails. To secure the other side, apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. I Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certifcate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 7 of 11 6.3.4 6.3.4.1 QOTRINITYIERD Presidential Shake TM, Presidential ShakeTm IR, Presidential Shake TLTM: LOW AND,STAND051,0 For lowand;starldarcl slopes; use tive ga[Wot *ft foA Presidential shingle as shgmt below Nailing i.---...40. —� .Guide: Lines (lptt tniri) 5:17A.. —� 14114' t-1 tj2 SA mmj (362 mni) NOTE;Apply nails on painted guideline: Figure 16-'6.• L'rlslening.P*sidengal rrrdFYesidenitd TL Shalm sbfn& offlow mid skmArd slgpes Hip & Ridge, Option 1: Presidential Accessory PRESIDENTIA.k ACCI SSORY STEEP SLOPE: Eordeep'slopes use nine nailsfor:each.fiipPresldentidslsingleand: apply 1' di2meter spots of asplialtroo4g cement under each sl n& tab. Alter applying`i nulls in li'eiimi thenalhnggoide finest, V2174lrla l fi' above 0ib-cutouts making certain labs 6f overlying slungle'coternail, 1 1' iliamelet asphalt roa. my cement Figure /6-7.. Fastening iteadenfid and Fms lefentkd r/L.Skike shinglis on Steep sk" S. PresideiiW,gccessory shingles;can be used for covering14 attd rid'ges:.Apply shinglesup: to therldge tespose no niorl3than 7".from the'boitom..edge.of the "tooth." Fasten eaclt:aceessoq.-vi ..two fas- tenors. Theusb1slong or longer, so'thoy penetrate. eitlier 3/4" intro the &;:.p. r eomgletelythroughthe dec6 Presidential accessory comes in two::differ eTit :$Iles: Ace essoryproduced in Blriningham,.AL is 12" x 12 , POrtland, OR produces974s".x 1 1-/4" accessory. Note: For_ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0 Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.4.2 Hip & Ridge, Option 2: Refer to instructions herein for Cedar CrestTM, Cedar CrestTM IR hip and ridge shingles. 6.3.5 HatterasTm: LOW, STANDARD AND STEEPSLOPE: Figure 75 t J;;7Ue umrg llalleras abides orj 401v rind Sraudiad anpa Far low and slaudsard i0pes, use five antis for eadt fill Iinuems shingle as:skown alwve.. Exterior Research and Design, LLC. Certificate of Authorization #9503 Ftere is-4. rvzxreujngiLilit nfSAAigf •s 9(I,C op.iippi For omp slap", ilse fnc nails and eight spins 9f; sPh t)t. onfusg tinitmi:foreacL iull:tt��eres sl>ingle:u shmin :ib6re. 1ppic_ 1' 425AW dinmeiet sjrois of rooIIag'cemcaojAStaf.11,458fi Type.11 sug evcYll'undereytli cols cornet pmss ahliioe.lnto phrrr.,cla:nol pox ceolcal. 00MON Inn aluck roofing cement on 011W shin les w 150 oer, Evaluation Report 3532.09.05-R8 FL5444-R7 Revision 8: 05/05/2014 Page 8 of 11 6.3.5.1 Hip & Ridge, Option 1: Accessory for Hatteras 3 Figura,0, 4 '-Greslidece Q`TRINITY I ERD Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. 6.3.5.2 Hip & Ridge, Option 2: Cut Hatteras Shingles I 1 I 1 �� Fas�ea ( 8.,—►{ �18 (469-0m) _ ro Cap. Cap Capap, Shingle Shingle Shingle S ifigle L�I �lZ Figure 1540. emtHatleras sbtnglesJo ma i .cover cap. Figure 15-21. Installation of caps along fitps and rUffl Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions. Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8 Certificate of Authorization #9503 FL5444-R7 Revision 8: 05/05/2014 Page 9 of 11 6.3.6 Highland SlateT"', Highland.Slatel IR: LOW AND.ST 'NO I to Figure 1 it usaFMnath foreaerylllghtwd Slafesbingle. STEEP.SLOPf US.e FMf nails and EIGi�1°spots of asphaltrooEng cement• for each fuil highland Slate shid&..F..orkflaml,Uade, SLY nails aze reggl ed. Apply ZV.diamefer spots.of asphalt roofln4cemeni undereach lah. corner ,."altroolingcemenl meeting_ASIWf.645%Typel.is'suggesled. llwgtcgade requims SDtnersIM'nnald' imleued over mnler,. 'ailaii ns,ah6�} Pigure:ll:3t: t1m) Y$nat andakfilspotsgfasphdf Yoofingeeit,Wunkri"04 ifi:corner. 'CAlJT101V E:(cessrre 0se;ofz6oIIng cement can cniie Sftutgies to blister, 6.3.6.1 Hip & Ridge, Option 1: Refer to instructions herein for Cedar CreStTM' Cedar CrestT"' IR or Shangle Ridge TO hip and ridge shingles. 6.3.7 PatriotTM: LOW AND STANDARD SLOPE Use MUR-tiails ftir every full shingle located its shorn belom lant 6-1 (25MA (155 mml �If gm mom) (mom � (M M— STEEP SLOPE Lrse FOUR nails and four spots of asplydt n,oliug cement for m-ery full shingle as shown below. Asphalt roofing remora meeting ASM D4. 586 1ype11 is suggested. Apply P(25 mum) spots of asphalt roofing cement as shorn. QUINN: Excessive use of roofing cement can cause shingles to blister. ------------ RODnQ Lemon! Hip & Ridge: Refer to instructions herein for Cedar CreStTM, Cedar CrestTM IR, Shadow RidgeTI or Shangle RidgeTm hip and ridge shingles. Exterior Research and Design, LLC. Certifcate of Authorization #9503 Evaluation Report 3532.09.OS-118 FL5444-R7. Revision 8: 09/05/2014 Page 10 of 11 y . a . 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC - QUA9625; (414) 248-6409; karen.buchmann@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118 Certificate of Authorization #9503 FL5444-117 Revision 8: 05/05/2014 Page 11 of 11