HomeMy WebLinkAboutEvaluation Report; CertainTeed Asphalt Roofing ShinglesEXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OTRINITYIERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
CertainTeed Corporation Evaluation Report 3532.09.05-1118
1400 Union Meeting Road FL5444-117
Blue Bell, PA 19422 Date of Issuance: 09/22/2005
Revision 8: 05/05/2014
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations
governing the use of construction materials in the State of Florida. The documentation submitted
has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code
and Florida Building Code, Residential Volume. The products described herein have been designed
to comply with the 2010 Florida Building Code.
DESCRIPTION: CertainTeed Asphalt Roofing Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality
Assurance Agency noted herein and FBC 1507.2.7.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, • P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 05/05/2014
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
QOTRINITYIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category; Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roofing Shingles, as produced by CertainTeed
Corporation, have demonstrated compliance with the following sections of the Florida Building Code and
Florida Building Code, Residential Volume through testing in accordance with the'following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
1507.2.5, R905.2.4
1507.2.7.1, R905.2.6.1
1507.2.7.1, R905.2.6.1
3. REFERENCES:
Entity
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL( TST 1740)
UL (TST.1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL LLC (TST 9628)
UL LLC (TST 9628)
UL LLC (TST 9628)
UL LLC (QUA 9625)
Property
Standard
Year
Physical Properties
ASTM D3462
2007
Wind Resistance
ASTM D3161, Class F
2006
Wind Resistance
ASTM D7158, Class H
2O07
Examination
Reference
Date
ASTM D3161
94NK9632
05/15/1998
ASTM D3161
99NK26506
11/23/1999
ASTM D3161
03CA12702
05/27/2003
ASTM D3161
03CA12702.
06/16/2003
ASTM D3161
.03NK29847
10/03/2003
ASTM D3161
04CA11329
05/24/2004
ASTM D3161
04CA32986
12/03/2004
ASTM D3161
OSNK07049
04/15/2005
ASTM D3161
OSNK16778
05/12/2005
ASTM D3161
OSCA16778
05/12/2005
ASTM D3161
05NK14836
05/22/2005
ASTM D3161
OSNK22800
06/22/2005
ASTM D3462
R684
09/21/2005
ASTM D7158
05NK08037
06/28/2006
ASTM D3161 & D3462
09CA28873
07/23/2009
ASTM D3462
IOCA41303
10/07/2010
ASTM D3161
10CA41303
10/08/2010
ASTM D7158
10CA41303
10/27/2010
ASTM D3161 & D3462
10CA44960
11/11/2010
ASTM D3161, D3462 & D7158
13CA32897
11/21/2013
ASTM D3161, D3462
TFWZ.R684
04/22/2014
ASTM D7158
TGAH.R684
04/22/2014
Quality Control
Service Confirmation
Exp. 02/13/2016
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
Certificate of Authorization #9503 FL5444-R7
Revision 8: 05/05/2014
Page 2 of 11
C�D
,,! I KINITY I ERD
4. PRODUCT DESCRIPTION:
4.1 CT201-, XTTM 25, XTTM 30 and XTTM 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles.
4.2 Carriage House Shangle@, Centennial Slate TM, Grand Manor Shangle@, Landmark TM,
Landmark TM IR, LandmarkTM Pro, Landmark TM Premium, LandmarkTM TL, Landmark TM Solaris
and Landmark TM Solaris IR are fiberglass reinforced, laminated asphalt roof shingles.
4.3 Presidential Shake TM, Presidential Shake TM IR and Presidential Shake TLTM are fiberglass
reinforced, architectural asphalt roof shingles.
4.4 HatterasTM, Highland SlateTM and Highland Slate TM IR are fiberglass reinforced, 4-tab asphalt
roof shingles.
4.5 PatriotTM is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a
.laminated appearance through an intermittent shadow line with contrasting blend drops for
color definition.
4.6 Presidential Accessory, Accessory for Hatteras, Shangle RidgeTM, Shadow Ridge TM, Cedar
CrestTM and Cedar CrestTM IR are fiberglass reinforced accessory shingles for hip and ridge
installation.
4.7 Any of the above listed shingles may be produced in AR (algae resistant) versions.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All shingles • noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.3.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge and Cedar Crest
hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F when BASF
Sonolastic.NP 1 adhesive or Henkel PL@ Polyurethane Roof & Flashing Sealant, applied as
specified in manufacturer's application instructions, indicating the shingles are acceptable for,
us in all wind zones up to Vasd = 150 mph (V,it = 194 mph).
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the
CertainTeed asphalt roofing shingles listed in Section 4.1 through 4.5 exceeds the calculated
uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (V„it = 194 mph) for
residential buildings located in Exposure D conditions with no topographical variations (flat
terrain) having a mean roof height less than or equal to 60 feet.
The shingles are permissible under Code for installation in these conditions using the
installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local,
jurisdiction, which shall take precedence.
5.4 All products in the roof assembly shall have quality assurance audits in accordance with the
Florida Building Code and F.A.C. Rule 61G20-3.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-R7
Revision 8: 05/05/2014
Page 3 of 11
6.
-0
'fit I KINOI'YIERD
INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the
shingle manufacturer's minimum requirements.
6.1.1
6.2
6.2.1
6.2.2
6.3
6.3.1
IMMM
Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida
Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections
1507.2.3, 1507.2.4 or R905.2.3.
Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or
Section R905.2.6 and the minimum requirements herein.
Fasteners shall be in accordance with manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope"
directions.
CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications,
subject to the limitations set forth in FBC Section 1510 and CertainTeed published installation
instructions.
CT20TM. XTTM 25, XTTM 30r XTTM 30 IR:
0VAND STANDARD SLOPE
ENGLISH t2"
12" 12"
r.1'(25mm)
Sealant
1"(25mm)
(1A5 rums
5: j1p4 for 1darfood
Flapt
1AEUK
13Va" 131/V —. + 131N. ►{
-}-
(�1"(25mm)
Sealant '1"(25mn)- 1
6 V•a"
T
Rgare11-3: Usefb-na&,forezzwyfrdi'sbMgls
Hip & Ridge: Cut Shingles
(25arnrp�l t-'�n t� �
t!t }i"C
f—
---—-—— — — — —i 12"
Cap Cap Cap (3A5lmm)
Shingle Shingle Shingle —1
Figure ll-2d: Cut tabs, then trin)-backto malreeap sbin&
(Englisb dhneosums Awn).
STEEP SLOPE
Use. -four n.dls and six spots of asph4t roofing cement for every fall
shingle (Figure 11-4). Asphalt roofing cement meeting ASTM D4586
Type 11 is suggested.
---- -- ---
to
Rooting Cement
Apply 1" (25 ntrn) spols of asphalt roofing cement
under each tab corner.
Figrar 11-4. Use four n0v and stx sPoks:gfaspfirillaatmnl on.stecgislo*
'CAUTION: Excessive use of roofing cement can cause shingles
to blister.
god
.` Ts
�``�� 2�NoNyooaP�ar1
Figure 11-?5: lnstrrllatlorr of gips along dbe4lps 4nd ridges.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@
Polyurethane Roof & Flashing Sealant, in accordance with manufacturer's instructions.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
CertiFcate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 4 of 11
6.3.2 Carriage House ShancileM, Centennial Slater"' and Grand Manor Shancilen:
LOW..AND
STANDARD SLOPE,
(1461vi nails for every Ad! Sliafi&-
1" . —V
} i• C257 I i�5 rn)
Sj8" 65/6"
00.01m) (Vat")
Figure 174, Cse flee nails for etugn full Crand,41anorSbanble,
Crariage. Home Aingk; or Conleirrelid Slate.
6.3.2.1 Hip & Ridge: Shangle® Ridge
STEEP SLOPE
Use seven mills and diree spots of aspliall roofing cement. for every
fill Grand ,Manor Shingle. Use five naffs and three spots of asphalt
roofing cement for evtiry full Larrdage lfolnse Shingle and Gcalenalaf
Slale.:ipply usphalt roofing cement 1• (25 mm) from edge of shingle
(Figure 17-5). Uph:dt roofing ceffient nteeldng:1ST11 W586 7t'pe 11
Ls mggested.
Foim174.,i en installing GranildlanorSGnrrgWsonsleep sialm,
ave seven nafle and ttnee spots ofaspbar roojlt+g conmit.
,r__ 12• � 18' Exposure Remove tape
from the right side
1. ; g•� and fasten
SECOND
Fasten the
Remove left side's 851a. RIGHT
Ttds cape FIRST LEFT
Figure 17-19. Installation ofShangleO Ridge shingles
Flgtlrir 17-.18: Shenigleo Ridge. on bqu and ridges.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
Exterior Research and Design, L.L.C. Evaluation Report 3532.09.05-118
Certiricate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 5 of 11
QOTRINITYIERD
6.3.3 LandmarkTM Landmark'" IR LandmarkT" Pro (formerly Landmark'"" Plus),
LandmarkTI Premium LandmarkTm TL, Landmark TM Solaris, Landmark TM Solaris IR:
lONi AND STANDARD SLOPE LANDMARK n
13'/1' 13" 13t/2"
METRIC DIMENSIONS 1---(343 mm)-! +-(334 mm)-► (343 mm}-c)
t2" 1014" 12" I.•-1" (25 mm) 1" (25 mrt) +I •
�+-(305 mm)-►-*-(375 mm)--"--(305 mm)-►{ _
� •xx�,�rx..xvz�s�:c�r>
1"(25mm): Release Tape 1'(25rnht)-
11_
Natlable_ 4 Frger,r 73••t. l sefory nvrtsfor erer7fillf st ingte.
Atea
STEEP, SLOPE
Usesi:X nails and four. spots of asphalt roofing cement for even full
lag) WA.ed shingle:. See below. Asphalt roofing cement should meet
ARM N5011rpe If. Apply 1" spots of asphalt roofing cement ande
each corner and at about 121, to 13 m from each edge.
METRIC DIMENSIONS.
�-10/4"
'12"—►
. (305 niin)
(375 mm)
(305 mm)
fie lease Tape
hlArea�
__
—�
rc Sleepy
(25.mm) -----
#
(25mm,
6.3.3.1 Hip.& Ridge, Option 1: Shadow RidgeT"'
Ftgrgnl,�:16.• SGarlou�ltfdga accswory sGtngles datrtcG erasilvJiom
Ibme- kxunitstomake72fnelividwdca/)Plecar.
12"
(305mm)
{15amm) (150mm)
Z" \ f T
,into) Notches for Alignimnt to
the Top Edge POW Previous T
top for 5" (125mm) Exposure (18oIn
_.__!
English Dimension
Exterior Research and Design, LLC.
Certificate of Authorization #9503
LANDMARK IL
—131/2" '- 13"—«.--13't.'
(343 m t) ( mm) (343 nm)
1"(25mm)-►i
Rvtnr t3 S' aso so nails ulna!four spols of
asphalt nwfing maamt Orr sleep stapca
97/r
(125mm) I (125mm)
Notch for.
Centering
itq^
mm) Notches forAlignment to 5
the Top Edge of the Previous 7 Capfor5W(141mm).Ex. sure (1m m)
Metric Dimension
Evaluation Report 3532.09.05-118
FL5444-R7
Revision 8: 05/05/2014
Page 6 of 11
,2"
✓ (305rt��T)
Laying Notch
i/'
I I
PigrffaJj 2o. Use livingnolches k ce.nlar ihftr glen on hips and
ridges,.andto locate the coiml exposure.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.3.2 Hip & Ridge, Option 2: Cedar CrestTM, Cedar CrestTM IR
Use two fasteners per shingle. For the starter shingle, place fastener 1-inch from each side
edge and about 2-inch up from the starter shingle's exposed butt edge. For each full Cedar
Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each
side edge.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp
Polyurethane Roof & Flashing Sealant to hand -seal Cedar Crest shingles. Apply NP 1 or PL
adhesive from the middle of the shingle's raised overlay on the top piece and extending
approximately 4-inch along the sides of the headlap along a line 3/4 to 1-inch from each side
of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing
tab sides into the adhesive, and install nails. To secure the other side, apply a 1-inch
diameter spot of NP 1 or PL adhesive between the shingle layers.
Nae�+.Raing arfr�4ve
�(102naml
t•
Oabotasplsa0. j
catderAWK0en & laygrs ( 1
shin25, of
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 7 of 11
6.3.4
6.3.4.1
F_YD
\-J TRINITY JERD
Presidential ShakeTM, Presidential ShakeT1 IR, Presidential Shake TLTM:
LOW AND STANDARD SLOPE:
For lOw�and standard slopes, use flit nails for each fail Presidential
shlilgle;as shown below.
Neilln' �.-- 40" --�
GuIAe tines (1.016. mm)
5:1L4„ —7—
(133)timi • • 14114"
1 ]2' 3A tnmy (362 mm)
NOTE: AppIV nails on painted guideline.
Figure.(&6 Fastening Presidential.and PreskWalTLSbalm
Absgla on low mid standard slopes
Hip & Ridge, Option 1: Presidential Accessory
PRESIDENTIAL ACCESSORY
STEEP SLOPE:
For steep slopes, use nine nails for each fail Presidential shingle and
apply 1' diameter spots of asphalt roofing cement under eactt.sldngle tab.
After opplying'5 nails In between the nailing guide lines, apply: d nails f'
above. tab cutouts making certaln Llbs.of overlying shingle cover nails.
}
T
1' diameter asphalt rooting cement
Figure i6.7. Fastening Presklend'al and Presidential T/L Sbake
sbingles on steep slopes.
Ptesidential. accessory shingles can be used for covering hips and
rdges: Applyshingles up to the ridge (expose no more than 7" from
Elie bottcm edge of the "tooth." Fasten each accessory-W1 two fas-
teners. The fasteners.must be '04" long or longer, so they penetrate
elti a 3�T' into the deck or completely through the deck. Presidential
a. Ccessoly.comes in two different sizes: Accessory produced in
Mrmingham, AL,is 12" x 12"; Portland, OR produces 97/8 x 1341"
accessory..
Note: For ASTM D3161. - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL®
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.4.2 Hip & Ridge, Option 2: Refer to instructions herein for Cedar CreStTM, Cedar CrestTM IR hip
and ridge shingles.
6.3.5 HatteraSTM:
LOW; -STANDARD AND STEEP -SLOPE:
figure IS,-;P f'ImIning !rn/lerns Sbiuglrs on
.LoreandSlandaI Sio/rev
Por.low aads(on6rd slopes, use fire Indls for Led, full
u;weru shingles shown above.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Ngum 154: %nrenirig dnJte>.+s Sbiugles an UMP Slopes
ror sicep st eNs, use fie nabs and eight spas of asplinll roofing
cemem for eack lull ttAuem Shingle as shown above Apply I`
(23huu) diameter aln*s ofrongng cemem WS7811) W61ype 11
sug,pc$av0 under.+ml+ lab Comet PrLKs shingle bile phire: da 1101
espose conical.
GiuTION: Toonuirh roofing cemem cm anise shingtes to blister.
Evaluation Report 3532.09.05-118
FL5444-R7
Revision 8: 05/05/2014
Page 8 of 11
6.3.5.1 Hip & Ridge, Option 1: Accessory for Hatteras
i
i
�., r.,
.............:>:.. ...
2 3
Ftgura 13-14 18 tf>rce pieca. unifs sepanite to make
`547fatferasAaessory sfifngles,
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.5.2 Hip & Ridge, Option 2: Cut Hatteras Shingles
Easier
8' 18' (460 mm) go\�
(203 mrm 1nl aeS cal
Cap. Cap Cap Shingle
Shingle Shingle Shingle
Zaon`
Aprs l5-'2O.,:Cut liatleras sbdngfes to make cover cap. Figure 15-21: Installation of caps along baps and HdRes.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 9 of 11
6.3.6 Highland Slate'"', Highland Slate"' IR:
[OVtf ANDSTAIfDAR.D SLOPE:
F19=04M.,1L+`o FIPW naik; for every HFgUm d Slate sbingkr
(-)0
rt 1 RINI7YIERD
STEEP SLOPE:
Use FnTi nails and EIGHT spots of asphalt roofing cement' for each
fill Inghland Slate shingle, For Mtamf-Dade, SLY naffs are required.
Apply I' diameter spots of asphalt roofing cement under each tab
corner. Asphalt roofingcement meeting ASI:M D4586 Ve Ills suggested
Figure I13& Erse Fm=* and eigbi Spais ofaspball
rooft cenveil cinder each tab corner.
CAUTION:: Excessive,use;otroofing cement can cause shingles
to blister.
6.3.6.1 Hip & Ridge, Option 1: Refer to instructions herein for Cedar CrestTM' Cedar CrestTM IR or
Shangle RidgeTm hip and ridge shingles.
6.3.7 PatriotTp1:
LOW AND STANDARD SLOPE
Use YOUR nails for erety full shingle located as shown helot.
S�aWnt
(25me 1 F i P(25ar1
(t min)
t l— 13tio' ►� 13f,8' ►�• lzfl3 +�
(333mm; (333 vr) (Sao
STEEP SLOPE
Use M R nails and four spots of asph:dt rooting cement for every full
shingle as shown below. Asphalt roofing cement meeting ASfM D4586
I4pe.I1 is suggested Apply 1'(25 min) spots of asph:dt roofing
cement as shown.
CALMON: Excessive use of roofing cement can cause shingles to blister.
�.. 3amj - — — — — — i'p5c�'F^'
9-VY I
(156-1 1 • ^ J C
Reafinp Cement
--j— t133W; - .tmni'i
Hip & Ridge: Refer to instructions herein for Cedar CrestTM, Cedar CrestTM IR, Shadow
Ridge TM or Shangle RidgeTm hip and ridge shingles.
Exterior Research and Design, L.L.C.
Certificate of Authorization #9503
Evaluation Report 3532.09.05-118
FL5444-R7
Revision 8: 05/05/2014
Page 10 of 11
`�1T�NrrYIERD
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by theBuilding Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
61G20-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC - QUA9625; (414) 248-6409; karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 11 of 11
EXTERIOR RESEARCH & DESIGN, LLC.
�y Certificate of Authorization #9503
TRIM 1 1 353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
CertainTeed Corporation Evaluation Report 3532.09.05-118
1400 Union Meeting Road FL5444-117
Blue Bell, PA 19422 Date of Issuance: 09/22/2005
Revision 8: 05/05/2014
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations
governing the use of Construction materials in the State of Florida. The documentation submitted
has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code
and Florida Building Code, Residential Volume. The products described herein have been designed
to comply with the 2010 Florida Building Code.
DESCRIPTION: CertainTeed Asphalt Roofing Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality
Assurance Agency noted herein and FBC 1507.2.7.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality. Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:.
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nleminen, P.E. on OS/OS/2014
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
product.
C"YD
'� 1 KINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roofing Shingles, as produced by CertainTeed
Corporation, have demonstrated compliance with the following sections of the Florida Building Code and
Florida Building Code, Residential Volume through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
1507.2.5, R905.2.4
1507.2.7.1, R905.2.6.1
1507.2.7.1, R905.2.6.1
3. REFERENCES:
Entity
UL (TST 1740)
UL (TST 1740 )
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740 )
UL (TST 1740)
UL LLC (TST 9628)
UL LLC (TST 9628)
UL LLC (TST 9628)
UL LLC (QUA 9625)
Property
Standard
Year
Physical Properties
ASTM D3462
2007
Wind Resistance
ASTM D3161, Class F
2006
Wind Resistance
ASTM D7158, Class H
2O07
Examination
Reference
Date
ASTM D3161
94NK9632
05/15/1998
ASTM D3161
99NK26506
11/23/1999
ASTM D3161
03CA12702
05/27/2003
ASTM D3161
03CA12702
06/16/2003
ASTM D3161
03NK29847
10/03/2003
ASTM D3161
04CA11329
05/24/2004
ASTM D3161
04CA32986
12/03/2004
ASTM D3161
OSNK07049
04/15/2005
ASTM D3161
05NK16778'
05/12/2005
ASTM D3161
05CA16778
05/12/2005
ASTM D3161
05NK14836
05/22/2005
ASTM D3161
OSNK22800
06/22/2005
ASTM D3462
R684
09/21/2005
ASTM D7158
05NK08037
06/28/2006
ASTM D3161 & D3462
09CA28873
07/23/2009
ASTM D3462
10CA41303
10/07/2010
ASTM D3161
IOCA41303
10/08/2010
ASTM D7158
IOCA41303
10/27/2010
ASTM D3161 & D3462
10CA44960
11/11/2010
ASTM D3161, D3462 & D7158
13CA32897
11/21/2013
ASTM D3161,D3462
TFWZ.R684
04/22/2014
ASTM D7158
TGAH.R684
04/22/2014
Quality Control
Service Confirmation
Exp. 02/13/2016
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-R7
Revision 8: 05/05/2014
Page 2 of 11
4.
C_"�D
TRINITY' I ERD
PRODUCT DESCRIPTION: vT
4.1 CT20TM, )CrTM 25, XTT- 30 and XTT" 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles.
4.2 CarriageHouse Shangle@, Centennial Slate TM Grand Manor Shangle@, Landmark T"',
Landmark TM IR, Landmark TM Pro, Landmark TM Premium, LandmarkT"' TL, Landmark TM Solaris
and LandmarkT"' Solaris IR are fiberglass reinforced, laminated asphalt roof shingles.
4.3 Presidential Shake TM, Presidential Shake TM IR and Presidential Shake TLT`" are fiberglass
reinforced, architectural asphalt roof shingles.
4.4 HatterasTM, Highland SlateTm and Highland Slate TM IR are fiberglass reinforced, 4-tab asphalt
roof shingles.
4.5 PatriotTP9 is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a
laminated appearance through an intermittent shadow line with contrasting blend drops for
color definition.
4.6 Presidential Accessory, Accessory for Hatteras, Shangle Ridge TM, Shadow RidgeT°°, Cedar
CrestTm and Cedar Cre8tTM IR are fiberglass reinforced accessory shingles for hip and ridge
installation.
4.7 Any of the above listed shingles may be produced in AR (algae resistant) versions.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM.D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.3.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge and Cedar Crest
hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F when BASF
Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as
specified in manufacturer's application instructions, indicating the shingles are acceptable for
us in all wind zones up to"Vasd = 150 mph (V„it = 194 mph).
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less.. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT) for the
CertainTeed asphalt roofing shingles listed in Section 4.1 through 4.5 exceeds the calculated
uplift force (FT) at a maximum design wind speed of Vasd = 150 mph (V,,,t = 194 mph) for
residential buildings located in Exposure D conditions with no topographical variations (flat
terrain) having a mean roof height less than or equal to 60 feet.
The shingles are permissible under Code for installation in these conditions using the
installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local
jurisdiction, which shall take precedence.
5.4. All products in the roof assembly shall have quality assurance audits in accordance with the
Florida Building Code and F.A.C. Rule 61G20-3.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 3 of 11
TRINITY I ERD
6. INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the
shingle manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida
Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections
1507.2.3, 1507.2.4 or R905.2.3.
6.2 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or
Section R905.2.6 and the minimum requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope"
directions.
6.3 CertainTeed asphalt shingles are acceptable for. use in reroof (tear -off) or recover applications,
subject to the limitations set forth in FBC Section 1510 and CertainTeed published installation
instructions.
6.3.1 CT20Tm,_XTTM 25, XTT"' 30• XTT'" 30 IR:
LOW AAD STANDARD SLOPE
ENGLISH' ?" 12" 12"
4—(l05 mm} _(305 mm)(305 mm)
jr-1"(25 ttti) — fart 1^(25mm}=�y
531a`'(1A5mni) 1 — J
5vi!*r'Nohvood
Plant:
METRIC f31le"L(25
'"(25To). ealant
silt,
T
Fygrore ll 3: Usa%ournaiG for eiary J4dl sbtngle
6.3.1.1 Hip & Ridge: Cut Shingles
(251mmI� I I 2 (fin) rRemove�
'
Cap Cap, Cap 3051mm)
Shingle shingle Shingle
1
,%tira ii-2 . Cnhtabs !lrert'h*f back to moko cap sbingles
(A`nglfsb Anmsfons.sbamn).
;STEEP SLOPE.
Use four ntdls mid six spots of asphalt roofing cement" for every full
shingle (Pigiire-ll-d). Asphali roofing cement iffeetingASTM D4586
ape II Is suggested.
I�
Rooting Cement
Apply 1" (25 mm) Spols of aephall roofing cement
under each tab comer.
Ffgum If-4: Usafour naffs and itxspoksgfnsp&a' t6aMl on sleep, ikp
cAUTIOmExcessive use of roofing cement.can.cause shingles.
ib blister.
_12'.(305'mm)
(t25:mm) % �ys�aes
_ �l`5��2 totN°NioodP
Fire 11-25: In5tn(!4t/on of cups along & bips:t nd rtdl -.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp
Polyurethane Roof & Flashing Sealant, in accordance with manufacturer's instructions.
Exterior Research and Design, LL•C.
Certifcate of Authorization #9503
Evaluation Report 3532.09.05-RS
FL5444-R7
Revision S: 05/05/2014
Page 4of11
(-)o
,.! I RINITYIeitD
6.3.2 Carriage House Shan4le@,
Centennial Slate"" and Grand Manor Shangle®:
!t)W:AND
ST6EP:SLOPE
STANDARD SLOPE
tie eeven ua}Is and d4w spots orwu 1i4kiaoinicc.00 ror ever}
Gse l?vc:natls fuiwcry hitShadgTe.
Iu1t Grand�lunor Shia L'sc ftre nailssnd lLree specs o(aspl��lt
moGgs cement for Cvcty 6�11 Larnure house Sltmgie aari .Gemenntal
fto.-Ali .asptrab rooting Cement 1' (25. min) from edge of sidn;ie
(Figriia 77=5�. Asniullt rw1%cement meeflag iST.M Q?>SG T}Pe 11
T"
�I
is61198istcd.
{25 rtpn)
(25 rm)
mm)
5(8T{
'or
{16.rnmj
(T2iltnnV
4 1
p•
I—t25mm}.
tzsm �i
Rom 174., Wfitr nWh fnr'iavo-fill Grand,ifariorSLmgle,
0o'riage llouse StrmiRk _ or Cenlew&l Sfak
6.3.2.1 Hip & Ridge: Shangle0 Ridge
Figure 17:1.5: Sbasrgle Ridge..
Flytre 175: 1ptrn inslrrUing.Grwrd Alannr;SGgnRtes nnsteep ilalrrs
ovsei•vis nalrsavi 1lncespoisoas? P41 roaJing crinerrJ.
EXposure Remove tape
from the right. side
i ;, g• and fasten
j �SECOND
Fasten the .�
leftsitle� $5�g RIGHT
FIRST
LEFT
Flgum 17.19:.Insfaffelioll ofSbnnglen Ridge shingles
on b1psakd iIdges
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
Exterior Research and Design, L.L.C. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 5of11
,rTRINITYIERD
6.3.3 LandmarkT'" Landrriark"m IR LandmarkTM Pro (formerly LandmarkTM Plus).
Landmark""' Premium LandmarkTm TL. Landmark' Solaris, LandmarkTM Solaris IR:
LOW AND STANDARD SLOPE tANDmARK n
METRIC DIMENSIONS
12 1.4'14„ 121.
�-(30.5inm)=-+($75mm)-� (3p5mm)-•{
ICI"(25mm) :Releas%Tape 1'•(25mm)�I •-
11/z
Naila6fa� .
Atea
STEEP SLOPE
Ease six: nails. and Four spots of.aspba(t roofing cement forewiy full
laminatedshingle. See. belo%e.ASpJ1dL,raol1ng cerno should meet
ASTSf 0445% 1),pe lt. Apply 1 ':sjtats ofasp,kropflug cement rind:.(
each cocoernnd.:it:nhold 12":ro'13" in h'oin each edge;
METRIC.Ii1MENSIONS
6.3.3.1 Hip & Ridge, Option 1: Shadow Ridge TM
Plgure 1-16 S6q�loiaRtdgQ nccessv "s.Linles.datnelr easlfyfrorn.
tb1xv-piax units. to nrnke,72individ[a+l cap pferes.
j305mm) —1
i
(159mm} I (15i1mm).
Not h for
Centering
(305inm) Notches forAfignmehttq'
the Top Edge of tho Pre .oils r
Captor5':(i4rnm)Expasure (18gmm)
t
EngIbb Dimension
131le 13" 13W,
(•—(343 mm0 mm)—► --(3d3 mm)—+ql
L-1"{25 mm) I 1" (25 mm)--i --
Figure i31: tsefuiir nnilsfor eroy fidl shig4e
LANDMARK TL
{343 (nit) ,(330RIM ) (343 min)
i rl a
' �—�••Ranliny Cemem
figirm l,?d? trsii six na k and friar spols of
-Pballroofing wnenron wopsleixec
Or
(125mm). I 1125mm)
Notch for
Centering
IotchesIorAlignment to 3.
'Top Eoge of the. 'Prev ious (196mm)
for55i$" (141 mm) txpo's
Metric Dimension
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
Certificate of Authorization #9503 F11-5444-1117
Revision .8: 05/05/2014
Page 6 of 11
QOTRINITYIERD
(3otn�—
Laying Notch
I I °•� I
A rme13� 20.• Use Gsylitgnok&e beenters6Tngleson hips and
ridges, ani to locatotGawrrectexpasara
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.3.2 Hip & Ridge, Option 2: Cedar CrestTM, Cedar CrestTM IR
Use two fasteners per shingle. For the starter shingle, place fastener 1-inch from each side
edge and about 2-inch up from the starter shingle's exposed butt edge. For each full Cedar
Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each
side edge.
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@
Polyurethane Roof & Flashing Sealant to hand -seal Cedar Crest shingles. Apply NP 1 or PL
adhesive from the middle of the shingle's raised overlay on the top piece and extending
approximately 4-inch along the sides of the headlap along a line 3/4 to 1-inch from each side
of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing
tab sides into the adhesive, and install nails. To secure the other side, apply a 1-inch
diameter spot of NP 1 or PL adhesive between the shingle layers.
I
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certifcate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 7 of 11
6.3.4
6.3.4.1
QOTRINITYIERD
Presidential Shake TM, Presidential ShakeTm IR, Presidential Shake TLTM:
LOW AND,STAND051,0
For lowand;starldarcl slopes; use tive ga[Wot *ft foA Presidential
shingle as shgmt below
Nailing i.---...40. —�
.Guide: Lines (lptt tniri)
5:17A.. —�
14114'
t-1 tj2 SA mmj (362 mni)
NOTE;Apply nails on painted guideline:
Figure 16-'6.• L'rlslening.P*sidengal rrrdFYesidenitd TL Shalm
sbfn& offlow mid skmArd slgpes
Hip & Ridge, Option 1: Presidential Accessory
PRESIDENTIA.k ACCI SSORY
STEEP SLOPE:
Eordeep'slopes use nine nailsfor:each.fiipPresldentidslsingleand:
apply 1' di2meter spots of asplialtroo4g cement under each sl n& tab.
Alter applying`i nulls in li'eiimi thenalhnggoide finest, V2174lrla l fi'
above 0ib-cutouts making certain labs 6f overlying slungle'coternail,
1
1' iliamelet asphalt roa. my cement
Figure /6-7.. Fastening iteadenfid and Fms lefentkd r/L.Skike
shinglis on Steep sk" S.
PresideiiW,gccessory shingles;can be used for covering14 attd
rid'ges:.Apply shinglesup: to therldge tespose no niorl3than 7".from
the'boitom..edge.of the "tooth." Fasten eaclt:aceessoq.-vi ..two fas-
tenors. Theusb1slong or longer, so'thoy penetrate.
eitlier 3/4" intro the &;:.p. r eomgletelythroughthe dec6 Presidential
accessory comes in two::differ eTit :$Iles: Ace essoryproduced in
Blriningham,.AL is 12" x 12 , POrtland, OR produces974s".x 1 1-/4"
accessory.
Note: For_ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL0
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.4.2 Hip & Ridge, Option 2: Refer to instructions herein for Cedar CrestTM, Cedar CrestTM IR hip
and ridge shingles.
6.3.5 HatterasTm:
LOW, STANDARD AND STEEPSLOPE:
Figure 75 t J;;7Ue umrg llalleras abides orj
401v rind Sraudiad anpa
Far low and slaudsard i0pes, use five antis for eadt fill
Iinuems shingle as:skown alwve..
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Ftere is-4. rvzxreujngiLilit nfSAAigf •s 9(I,C op.iippi
For omp slap", ilse fnc nails and eight spins 9f; sPh t)t. onfusg
tinitmi:foreacL iull:tt��eres sl>ingle:u shmin :ib6re. 1ppic_ 1'
425AW dinmeiet sjrois of rooIIag'cemcaojAStaf.11,458fi Type.11
sug evcYll'undereytli cols cornet pmss ahliioe.lnto phrrr.,cla:nol
pox ceolcal.
00MON Inn aluck roofing cement on 011W shin les w 150 oer,
Evaluation Report 3532.09.05-R8
FL5444-R7
Revision 8: 05/05/2014
Page 8 of 11
6.3.5.1 Hip & Ridge, Option 1: Accessory for Hatteras
3
Figura,0, 4 '-Greslidece
Q`TRINITY I ERD
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PLp
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
6.3.5.2 Hip & Ridge, Option 2: Cut Hatteras Shingles
I 1
I 1 �� Fas�ea
( 8.,—►{ �18 (469-0m)
_ ro
Cap. Cap Capap,
Shingle Shingle Shingle S ifigle L�I �lZ
Figure 1540. emtHatleras sbtnglesJo ma i .cover cap. Figure 15-21. Installation of caps along fitps and rUffl
Note: For ASTM D3161 - Class F, use BASF Sonolastic NP 1 adhesive or Henkel PL@
Polyurethane Roof & Flashing Sealant in accordance with manufacturer's instructions.
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R8
Certificate of Authorization #9503 FL5444-R7
Revision 8: 05/05/2014
Page 9 of 11
6.3.6 Highland SlateT"', Highland.Slatel IR:
LOW AND.ST 'NO I to
Figure 1 it usaFMnath foreaerylllghtwd Slafesbingle.
STEEP.SLOPf
US.e FMf nails and EIGi�1°spots of asphaltrooEng cement• for each
fuil highland Slate shid&..F..orkflaml,Uade, SLY nails aze reggl ed.
Apply ZV.diamefer spots.of asphalt roofln4cemeni undereach lah.
corner ,."altroolingcemenl meeting_ASIWf.645%Typel.is'suggesled.
llwgtcgade requims
SDtnersIM'nnald'
imleued over mnler,.
'ailaii ns,ah6�}
Pigure:ll:3t: t1m) Y$nat andakfilspotsgfasphdf
Yoofingeeit,Wunkri"04 ifi:corner.
'CAlJT101V E:(cessrre 0se;ofz6oIIng cement can cniie Sftutgies
to blister,
6.3.6.1 Hip & Ridge, Option 1: Refer to instructions herein for Cedar CreStTM' Cedar CrestT"' IR or
Shangle Ridge TO hip and ridge shingles.
6.3.7 PatriotTM:
LOW AND STANDARD SLOPE
Use MUR-tiails ftir every full shingle located its shorn belom
lant
6-1 (25MA
(155 mml
�If gm mom) (mom �
(M M—
STEEP SLOPE
Lrse FOUR nails and four spots of asplydt n,oliug cement for m-ery full
shingle as shown below. Asphalt roofing remora meeting ASM D4. 586
1ype11 is suggested. Apply P(25 mum) spots of asphalt roofing
cement as shorn.
QUINN: Excessive use of roofing cement can cause shingles to blister.
------------
RODnQ Lemon!
Hip & Ridge: Refer to instructions herein for Cedar CreStTM, Cedar CrestTM IR, Shadow
RidgeTI or Shangle RidgeTm hip and ridge shingles.
Exterior Research and Design, LLC.
Certifcate of Authorization #9503
Evaluation Report 3532.09.OS-118
FL5444-R7.
Revision 8: 09/05/2014
Page 10 of 11
y
. a .
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
61G20-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC - QUA9625; (414) 248-6409; karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 3532.09.05-118
Certificate of Authorization #9503 FL5444-117
Revision 8: 05/05/2014
Page 11 of 11