Loading...
HomeMy WebLinkAboutPA FL9777-R11 IM .:o rA ' BCIS Home ;' LqS In User Registration Rot Submit surcharge Sorts&Facts puhllca@vns Contact Us BCIS Site Map Links Search Product Approval dbPr '-. USER:Public User Prod,jN.y QAMyal MgU Product or A-pplkatlon Sears-ha Aunliratiort L-Esa Application Detail FL# FL9777-R11 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 grcg.keeler@owensc:oi-ning.com Authorized Signature Greg Keeler greg.kccler@owenscornhng.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL9777 R11 C41.-QCR1400Z- a Z017 FBC Evaluation Report Weatherlock Ikon-HVHZ. c f Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 ASTM a 226 2009 ASTM G 155 2005 https://www.floridabuilding.orgfpr/pr_app_dtl.aspx?pararn=wGEVXQwtQgtgkcMGblcW71%2fZr7gdugvKE9MFg53ndV601883S636Kw%3d%3d Page f of 3 TAS 103 1995 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option ❑ Date Submitted 10/11/2017 Date Validated 1 011 1/20 1 7 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model■NZmber or Name Description 9777.1 _ Weatherlock G Weatherproof-mg Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No Fj_9777 R1 t I! OCR1402 8a 2017 FSC Evaluation Reaoc Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.udf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure:NIA Created by Independent Third Parry: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777_R11 AE QLR14002 8a 20j7 FBC Evalu ion R par Weatherlock Non-HVHZ.odf _ Created by Independent Third Party: Yes 9777.2 M Weatherlock G(High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No 1977 R11 II O R14002 Sa 201Z FBC Evaluation Repo Approved for use outside HVHZ:Yes Weatherigcfc Ikon-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Parry: Yes Other: See evaluation report for limits of use. Evaluation Reports 777 RJA Ak_pCR14002 8a 2017 FBC 1valuatlon Re�rt Weatherlock Non-HVHZ Wf Created tly Independent Thlyd Party: Yes - 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 RII-II OCR14002.8h 2017 FBC Evaluation Repo Approved for use outside HVHZ: No Weatherlock HVHZ.ndf Impact Resistant:NIA Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 all_AE OCR14002 8b 2L117 FB v luatinp Report WeatherlocV HVHZ.odf Created by Independent Third Party:Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions W Approved for use in HVHZ: No EL9777 R11 ;1 QCRI4002 8a 2017 FSC Eyaluation Rgoort Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ,p!9f Impact Resistant: NIA Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See.evaluation report for limits of use. Evaluation Reports EL9777 R11 AE OCR14092 8a 2017 F C EValuatic,n Report Weathgflnck Non-H ffl p-df Created by Independent Third Party: Yes https:JJwww-floridahuilding-orgfprfpr_app_dtl.aspx?param=WGEVX4vvtDgtgkcMGblcW71%2fZr7gdugvKE7MFg53ndV5a98838B3BKw%3d%3d Page 2 of 3 9777.5 Weatherl-ock Metal Weatherproofing Underlayment Limits of Use Installation Instructions I Approved for use in HVHZ: No FL9777 Rii IQCR140D2 &a 2Qt7 FBC Evaluation Repi Approved for use outside HVHZ:Yes Weafiherlock Non-HVHZ odf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports a _ 9777 R11_� QCR140Q2 8� Q17 FBC Evaluation Reggrt W atherlock Non-HVHZ ndf Created by Ind ependentThird Party: Yes 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes EL2777 R11 I QCRI4002 8b 2Q17 FBC Evaluation Rgnort Approved for use outside HVHZ: NO Weatherlock HVH off Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports F 777 R11 AE QCR14QQ2 8b 207 FBC Evaluation Report Weatherlack HVH7.ndf Created by Independent Third Party: Yes 9777.7 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: ND FL9777 Tiii II (] R1400 $a 2Qi7�aluation ReP Qrt Approved for use outside HVHZ:Yes Weatherioct Non-hIVHZ Pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 f Design Pressure: +0/-142.5 Created by Independent Third Party: Yes i Other: See evaluation report for limits of use. Evaluation Reports EL2zzz—p11 AE_ Dorr Vlfeatherlock Non-HVHZ.Of Created by Independent Third Party: Yes �3Ck Fdext Contact d::2601 Hlair Stone goad,Ta€lahassee FL 32399 Phone:a50-48?-1824 The State of FlCrida is an AA7EE0 employer.CoWW D7- 013 S a Of Florida ::P1Eacv Statement:;Accessibility Statement Refund Statemen Under Florida late,email addresses are public records.If you do not want your a-mail address released in response to a pubic-records request,do not Send electronic mall to this entity.Instead,contact the office by phone or by tradivonal mail.If you have any questions,please contact 850.487.1395•*Pursuant to Section 4.5 .275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4S5,F,S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.tf you do not wish to supply a personal address,please provide the Department with an email address which can be made avallable to the public.To determine if you are a Ilcensee under Chapter 455,F.S.,please click�ieFe_. Product Apppr�o�val Accepts; } El M Credit Card Safe https://www.floridnibu€lding.org/pr/pr_app-dtl.aspx?param=wGEVXQwtl7gtgkcMGblcW7112fZr7gdugvKEIMFg53ndV601Basso36Kw%3d5,Sd Page 3 of 3 Certificate of Authorization No. 29824 CREEK 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL. SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,67"EDITION (2017) Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 wwW.owen scorninp_eom Manufacturing Location: Brentwood, NH Houston,TX Quality Assurance. UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity Report Na_ Standard Year PRI Construction Materials Technologies(TST5878) NEI-039-D2-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-053-02-41 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009 PRi Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) CCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) QCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) ❑CF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies(TST5878) QCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies{TS75878) OCF-321-02-DI ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1891 2012 PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09,Type I and II OCR14002.8a FL9777-Rl l Page 1 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not n nc.niFnolha e.iA.accad horn in +, CREEK OWENS eathe CORNING ROOFING e& ASPHALT LLC i WeatherLock®Self-Sealing lce 8 Water Barriers '"' TECHNICAL SERvicl s, LLC �i' PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive undertayment constructed from SIBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLockD Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood. NH or SIBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq. rolls with nominal dimensions of 3-11 x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Mat is permitted to be used as prescribed in FBG Section 15D7.1.1 for mechanically attached roof coverings_ Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock®Metal WeatherLockD Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x E6.7-ft. WeatherLock®Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLockD Specialty Tile & Metal is an ASTM D 1970 self-adhesive undertayment Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (lCP Adhesives and Sealants, Inc.) or TILE BONDTr 4 Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock®G(High WeatherLockD G(High Tear) is a self-adhered,underlayment used as an alternative to Tear) ASTM D 226,Type I or Type I I roofing felt and ASTM D 1970 self-adhering polymer (Houston, TX) modified bitumen underlayment. The underayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days_ OCR14002.8a FL9777-R1t Page 2 of This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not -AA—c ,i herein 11CREEK OWENS CORNING ROOF71NG AND ASPHALT LLC Weatherl-ock-0 Self-Sealing Ice&Water Barriers TECHNICALSERVtCEs, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC Application: All undedayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the clock shall be checked far protrusion and corrected prior to underlayment application_ Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6"end laps staggered min.6-ft.from preceding course. Additionally, if applying WeatherLockO Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap- It is permissible to back nail the underlayment 12-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, Weatherl-ocMD Specialty Tile& Metal shall be back nailed when installed on roof slopes greater than 3:12. Min.Application 40'F; Contact the manufacturer when installing at temperatures below the minimum Temperature; application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1—WeatherLock Specialty Tile&Metal Only Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underiayment: Weatherl-ock@ Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and baeknailed along the selvage with minimum 12ga., 1-114-inch galvanized ring shark roofing nails through optionally primed, 32ga. x 1-6/8-inch 0 tin caps spaced 12" c.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-R11 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not croriFir�R,a erl.irocooA hnrain ij OWENS CORNING ROOFING AND ASPHALT LLC j� Wedtherl-ockO Self-Sealing Ice&Water Barriers TECHisiiCAL SERVICES,LLC GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction, 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6'h Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 0���,EiliYiiijir�* v -fir rim`�- .�yr,E act' Z ■ e 0. No 74021 � � �- 09:06:29 -04'00' �''. STATE a F ►u "a, p Zachary R.Priest, P.E. `err -E 0 R t 0 a�'Z Florida Registration No. 74021 fO l0tt; Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest In any company manufacturing or distributing products under this evaluation, CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R, Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P_F does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF DEPORT OCR14002.8a FL9777-Rl l Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not anori�rvl hi vArlroacod horo,n