HomeMy WebLinkAboutPA FL9777-R11 IM .:o
rA '
BCIS Home ;' LqS In User Registration Rot Submit surcharge Sorts&Facts puhllca@vns Contact Us BCIS Site Map Links Search
Product Approval
dbPr '-. USER:Public User
Prod,jN.y QAMyal MgU Product or A-pplkatlon Sears-ha Aunliratiort L-Esa Application Detail
FL# FL9777-R11
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
grcg.keeler@owensc:oi-ning.com
Authorized Signature Greg Keeler
greg.kccler@owenscornhng.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL9777 R11 C41.-QCR1400Z- a Z017 FBC Evaluation Report Weatherlock
Ikon-HVHZ. c f
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2015
ASTM a 226 2009
ASTM G 155 2005
https://www.floridabuilding.orgfpr/pr_app_dtl.aspx?pararn=wGEVXQwtQgtgkcMGblcW71%2fZr7gdugvKE9MFg53ndV601883S636Kw%3d%3d Page f of 3
TAS 103 1995
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option ❑
Date Submitted 10/11/2017
Date Validated 1 011 1/20 1 7
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
FL# Model■NZmber or Name Description
9777.1 _ Weatherlock G Weatherproof-mg Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No Fj_9777 R1 t I! OCR1402 8a 2017 FSC Evaluation Reaoc
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.udf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:NIA Created by Independent Third Parry: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777_R11 AE QLR14002 8a 20j7 FBC Evalu ion R par
Weatherlock Non-HVHZ.odf
_ Created by Independent Third Party: Yes
9777.2 M Weatherlock G(High Tear) Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No 1977 R11 II O R14002 Sa 201Z FBC Evaluation Repo
Approved for use outside HVHZ:Yes Weatherigcfc Ikon-HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Parry: Yes
Other: See evaluation report for limits of use. Evaluation Reports
777 RJA Ak_pCR14002 8a 2017 FBC 1valuatlon Re�rt
Weatherlock Non-HVHZ Wf
Created tly Independent Thlyd Party: Yes -
9777.3 Weatherlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9777 RII-II OCR14002.8h 2017 FBC Evaluation Repo
Approved for use outside HVHZ: No Weatherlock HVHZ.ndf
Impact Resistant:NIA Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 all_AE OCR14002 8b 2L117 FB v luatinp Report
WeatherlocV HVHZ.odf
Created by Independent Third Party:Yes
9777.4 Weatherlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions W
Approved for use in HVHZ: No EL9777 R11 ;1 QCRI4002 8a 2017 FSC Eyaluation Rgoort
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ,p!9f
Impact Resistant: NIA Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See.evaluation report for limits of use. Evaluation Reports
EL9777 R11 AE OCR14092 8a 2017 F C EValuatic,n Report
Weathgflnck Non-H ffl p-df
Created by Independent Third Party: Yes
https:JJwww-floridahuilding-orgfprfpr_app_dtl.aspx?param=WGEVX4vvtDgtgkcMGblcW71%2fZr7gdugvKE7MFg53ndV5a98838B3BKw%3d%3d Page 2 of 3
9777.5 Weatherl-ock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
I Approved for use in HVHZ: No FL9777 Rii IQCR140D2 &a 2Qt7 FBC Evaluation Repi
Approved for use outside HVHZ:Yes Weafiherlock Non-HVHZ odf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
a _ 9777 R11_� QCR140Q2 8� Q17 FBC Evaluation Reggrt
W atherlock Non-HVHZ ndf
Created by Ind ependentThird Party: Yes
9777.6 WeatherLock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes EL2777 R11 I QCRI4002 8b 2Q17 FBC Evaluation Rgnort
Approved for use outside HVHZ: NO Weatherlock HVH off
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
F 777 R11 AE QCR14QQ2 8b 207 FBC Evaluation Report
Weatherlack HVH7.ndf
Created by Independent Third Party: Yes
9777.7 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: ND FL9777 Tiii II (] R1400 $a 2Qi7�aluation ReP
Qrt
Approved for use outside HVHZ:Yes Weatherioct Non-hIVHZ Pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
f Design Pressure: +0/-142.5 Created by Independent Third Party: Yes
i Other: See evaluation report for limits of use. Evaluation Reports
EL2zzz—p11 AE_ Dorr
Vlfeatherlock Non-HVHZ.Of
Created by Independent Third Party: Yes
�3Ck Fdext
Contact d::2601 Hlair Stone goad,Ta€lahassee FL 32399 Phone:a50-48?-1824
The State of FlCrida is an AA7EE0 employer.CoWW D7- 013 S a Of Florida ::P1Eacv Statement:;Accessibility Statement Refund Statemen
Under Florida late,email addresses are public records.If you do not want your a-mail address released in response to a pubic-records request,do not Send electronic
mall to this entity.Instead,contact the office by phone or by tradivonal mail.If you have any questions,please contact 850.487.1395•*Pursuant to Section
4.5 .275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4S5,F,S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.tf you do not wish to supply a
personal address,please provide the Department with an email address which can be made avallable to the public.To determine if you are a Ilcensee under Chapter
455,F.S.,please click�ieFe_.
Product Apppr�o�val Accepts;
}
El M
Credit Card
Safe
https://www.floridnibu€lding.org/pr/pr_app-dtl.aspx?param=wGEVXQwtl7gtgkcMGblcW7112fZr7gdugvKEIMFg53ndV601Basso36Kw%3d5,Sd Page 3 of 3
Certificate of Authorization No. 29824
CREEK
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL. SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,67"EDITION (2017)
Manufacturer. OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
wwW.owen scorninp_eom
Manufacturing Location: Brentwood, NH
Houston,TX
Quality Assurance. UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
Entity Report Na_ Standard Year
PRI Construction Materials Technologies(TST5878) NEI-039-D2-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-053-02-41 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009
PRi Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) CCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) QCF-272-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) ❑CF-296-02-02 ICC-ES AC 188' 2012
ICC-ES AC 48 2012
PRI Construction Materials Technologies(TST5878) QCF-297-02-01.1 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-318-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies{TS75878) OCF-321-02-DI ASTM D 1623 2009
PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1891 2012
PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012
'Determined to be equivalent to ASTM D 226-09,Type I and II
OCR14002.8a FL9777-Rl l Page 1 of 4
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
n nc.niFnolha e.iA.accad horn in
+, CREEK OWENS
eathe CORNING ROOFING e& ASPHALT LLC
i WeatherLock®Self-Sealing lce 8 Water Barriers
'"' TECHNICAL SERvicl s, LLC
�i'
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive undertayment constructed from SIBS
(Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLockD Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood. NH or SIBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX) sq. rolls with nominal dimensions of 3-11 x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used as prescribed in FBG Section 15D7.1.1 for
mechanically attached roof coverings_ Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock®Metal WeatherLockD Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x E6.7-ft.
WeatherLock®Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock® WeatherLockD Specialty Tile & Metal is an ASTM D 1970 self-adhesive undertayment
Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric.
(Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (lCP
Adhesives and Sealants, Inc.) or TILE BONDTr 4 Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock®G(High WeatherLockD G(High Tear) is a self-adhered,underlayment used as an alternative to
Tear) ASTM D 226,Type I or Type I I roofing felt and ASTM D 1970 self-adhering polymer
(Houston, TX) modified bitumen underlayment. The underayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days_
OCR14002.8a FL9777-R1t Page 2 of
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
-AA—c ,i herein
11CREEK
OWENS CORNING ROOF71NG AND ASPHALT LLC
Weatherl-ock-0 Self-Sealing Ice&Water Barriers
TECHNICALSERVtCEs, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the clock shall be checked far protrusion and corrected prior to underlayment
application_ Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6"end laps staggered min.6-ft.from preceding course. Additionally, if
applying WeatherLockO Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap-
It is permissible to back nail the underlayment 12-inches on-center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, Weatherl-ocMD Specialty Tile& Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min.Application 40'F; Contact the manufacturer when installing at temperatures below the minimum
Temperature; application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1—WeatherLock Specialty Tile&Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underiayment: Weatherl-ock@ Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and baeknailed along the
selvage with minimum 12ga., 1-114-inch galvanized ring shark roofing nails through
optionally primed, 32ga. x 1-6/8-inch 0 tin caps spaced 12" c.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-R11 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
croriFir�R,a erl.irocooA hnrain
ij OWENS CORNING ROOFING AND ASPHALT LLC
j� Wedtherl-ockO Self-Sealing Ice&Water Barriers
TECHisiiCAL SERVICES,LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction,
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6'h Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
0���,EiliYiiijir�*
v -fir
rim`�- .�yr,E act' Z ■ e 0.
No 74021 � � �- 09:06:29
-04'00'
�''. STATE a F ►u
"a, p Zachary R.Priest, P.E.
`err -E 0 R t 0 a�'Z Florida Registration No. 74021
fO l0tt; Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest In any company manufacturing or distributing
products under this evaluation,
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R, Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P_F does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF DEPORT
OCR14002.8a FL9777-Rl l Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
anori�rvl hi vArlroacod horo,n