HomeMy WebLinkAboutPA FL5259-R29 :
. __ T..:. ..
........ -:.. .:, w. ::._ ..__ ... �._ ..:.. .. i v.«s ti:]wJ 1 Tr_�.:.G,J,e4,,1.a i 4rA ':-.4. ,, '•:.r.[...'.r..��..:
6CIS Home Log Ties User Registration Hot Topics Submit Surcharge - Srats&Fads Publications Contact Us ECIS Site Map Links Seerrh
/ Product Approval
USER:Public User
do' pr
Product Approval_Meeu 7 Product or Agol ication Search>Apal icaaon List�Appi ication Detail
FL# FL5259-R29
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Arch ived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
ma I pert@polyglass.corn
Authorized Signature Maury Alpert
malpert@polyg lass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(856) 802-8017
uspolyglasstech n Ical@ polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnlcal@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 1 0/2 1120 2 2
Validated By John W. Knezevich, PE
. Validation Checklist-Hardcopy Received
Certificate of Independence FL5.2 ._R29 COI 2019, _Q CO NIEMINEN.D¢f
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
AS7M D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D5509 2009
FM 4474 2011
FRSA/TRI April 2012 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2019
Date Validated 10/16/2019
Date Pending FBC Approval 1DJ20/2019
Hate Approved 12/10/2019
Summary Of_Pro ucts
FL V Model,Number or Name Description
15259.1 Poiyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5259 R29 Il 2019 10 FINAL ER POLYGLASS UNDERLAYMENT,� FL5259-
Approved for use outside HVHZ:Yes R 9.pd
Impact Resistant: N/A Verified By: Robert Nleminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party: Yes
other: 1.)The design pressure in this i Evaluation Reports
application relates to one particular FL5254„R29 AE_ 19 1 H_N L_BR 9 LY�LASS UNQERLAYMENTS F 25 -
underlayment system(over concrete deck) R29.ndf
for use under foam-on tile systems(where Created by Independent Third Party: Yes
the underlayment farms part of the load-
path). Refer to ER Section 5.6.1 for other
systems, other deck types and associated
maximum design pressures. 2.)Refer to ER
Section 5 for other limits of use. I
Sack ?iezY
on aet ]s::26R1 131air 5ton Road Tat nassee FL 3z399 Phone:8504D7-1824
The State of Florida is an AAIE50 employer.Coovriaht 2007-2013 State of Florid Prlvacq.Statement::AccesslbillU Staterrie_nt::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mail,If you have any questions,please contact 854-457.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees Ilcensed under chapter 455,FS.must provide the vepartrrlent with an email address if they have
one.The eri provided may be used for official communication with the licensee,however email addresses are public record.if you do not wish to supply a
personal address,please provide the Departmentwith an email address which can be made available to the public.To determine if you are a llcensee under chapter
455,FS.,please chick here.
Product Approval Accepts:
etnF56
Credit Card
Safe
�I
NEMQ I etc.
Cerrificcte of Authorization#32455
353 Christian Street, Unit#13
uto Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATIONREPORT
Polyglass USA, Inc. Evaluation Report 1312060.02.09-1125
1111 West Newport Center Drive FL5259-1129
Deerfield Beach, FL 33442 Date of Issuance:02/24/2009
(954)233-1230 Revision 25:10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6'h Edition(2017)Florida Building Code sections noted herein,
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility locations). NEMQletc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Cade Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16.
Prepared by:
A.w
=J
�1
Robert J.M.
.M. Nieminen, P.E.
Florida Registration No.59166,FiQrIda D[,Q ANE1983 The facsimile seat appearing was authorized by Robert Nieminen,P.E.on
10114/2C19,This does not serve as an e[ectronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc, does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOl etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4, Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOletc, nor Robert Nieminen, P.E. are, in any way, the Designer of Record forany
project on which this Evaluation Report, or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 MEMO ETC,LLC
NMEMO I etc.
RoOFING COMPQNENT ►
1. SCOPE;
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations I Conditions of Use set forth herein.
2. STANb MS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1504.3.1 Wind Uplift UL1897 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1S07,2.4/1507.11,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1507,11.2 Physical Properties ASTM D6263 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2611
1507.11.2 Physical Properties ASTM D6509 2009
TA5110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date Entity Examination Reference Date
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Tensile adhesion P4039C.04.15 04/03/2015
ERD(TSTGD49) Wind Uplift 11776-06.02 01/16/2003 ERD(TST 6D49) TAS 103 P4436C.10.14-R1 05/18/2015
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Wind Uplift PLYG-SCS905-05-16-1 0S/17/2016
ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2DD7 ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016
ERD(TST 6049) Wind Uplift P9260-03.08 03/21/2098 ERD(TST 6049) Tensile adhesion PLYG-SCLG130.06,16-2 06/27/2016
ERD(TST6049) Wind Uplift P30540.11.09-R1 11/30/2099 ERD(TST 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016
ERD(TST 6D49) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 6049) ASTM U197CID4798 PLYG-SC8080.07.16 07/16/2016
ERD MT 6049) Wind Uplift P1193011.09-2 11/30/2009 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) ASTM D4977 1`11030.11.09-3 11/30/2009 ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016
ERD(TST 6049) ASTM D1970 P33360.06.10 06/25/2010 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(CST 6049) TAS 103 P33370.03.11 03/02/2011 ERD(TST 6049) TAS 103 PLYG-SC1211S.98.17 08/08/2017
E RD(TST 6049) Tensile Adhesion P33370.G4.12 04/25/2011 PRD(TST 5049) TA3103 PLYG-SC3303S.08-17 10/21/2077
ERD{TST 6049) ASTM D1970 P37300AG-11 10/19/2011 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(15T6049) TAS 103 P40390.08.12-1 08/06/2012 ICC-ES(SVL 2396) IBC Compliance ESR-1697 D410112019
ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08/0 712 0 1 2 M-D(CER 2592) HVHZ Compliance NOA 17-0614.22 07/06/2017
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 MTI(TST 2508) ASTM D4798 J9201-17A 04/01/2C08
ERD(TST 6(349) Wind Uplift 1`39680.03.13 03/04/2013 NEM0(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/2912018
ERD(TST 60491 ASTM V1970 P45370.04.13 0412612013 NEMO(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEM4(TST 6049) ASTM D6163 4S-PLYG-18.00Z.01.19-A 01/24/2019
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEM0(TST 60491 ASTM D6222 45-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) ASTM D6164 P37590-03-13-3A 05/06/2013 NEMO(TST 6049) TAS 103 45-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) ASTM 06509 P37590.03.13-1-R1 06/26/2013 NEMO(TST 6049) TAS 103 45-PLYG-18-004.10.19-I 10/08/2019
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2019 N E M 0(TST 6D49) TAS 103 45-PLYG-18-004.10.19-L 10/09/2019
ERD(TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 1011 0/2 0 19
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 PRI(TST5878) Tensile Adhesion PRID1111 04/08/2002
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 PRI(TST5878) TAS 103 PUSA-018-02-01 07/14/2003
ERD(TST 6p49) 30/90 physicals P4527C.05.14 05J1212014 PRI(TS75878) 7AS 103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/09/2014 PRI(TST S878) TAS 103 P05A-055-02-02 12/10/2007
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI(TST5878) ASTM D6222 PUSA-051-02-02 01/29/2008
ERD(TST 6049) Tensile adhesion P46520A0A4 10/03/2014 PRI(TST5878) ASTM D6164 PUSA-GH-C2-01 07/29/2009
ERD(TST 6049) ASTM D1970/D4798 P43290.10.14 10117/2014 Polygtass USA P/L Affidavit Mule-Hide Cross Ltg 03,101/2008
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authoriraflon#32455 6n'EDITION(201.7)FBC NON-l4VMZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)2 33-123 0 Revision 25:10/14/2019
Page 2 of 16
OMEMO I etc.
Entity Examination Reference Date Enti Examination Reference Date
ERD(TST 6049) TAS 103 PLYG-SC7550.03AS 0 3124/2 0 15 Polygfass USA Mate Fla15 Affidavit Palystick Compound 0811812011
UL(Q.UA962S) quality Control Service Confirmation C9/13f2018
4. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced,modified bitumen the underlayment
FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back-
side and granule-surfaced APP modified bitumen top-side
4.4 Elastoflex 56 G ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI April 2012
4.5 Elastoflex S6 G FIR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI April 2012
4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.7 HydraGuard Dual Pro ASTM D1970 FL Nominal GO-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.8 HydraGuard Tile Pro ASTM❑1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
TA5 1D3 waterproofing membrane,fiberglass reinforced,with a
FRSAITRI April 2012 polyester fabric surface
4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI April 2012
4.10 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened or adhered tile roof
systems
4.11 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April ---- use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened the roof systems
4.12 Poly-flex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRl April 2012
4.13 Polyflex SA P FIR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.14 Polyg.lass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.15 Polygfass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
4.16 Polystick IR-Xe ASTM D1970 FL,PA Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.17 Polystick MTS Plus TAS 103 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing;
FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
MEMO ETC,u c. Evaluation Report 1`12060.02.09-1125
certificate ofAurhoraafion#32455 6""EDITION(2017)FBC NON-HVHZ EVALUAnON FL5259-1129
Polyglass Roof Underlayments;(9s4]233-1230 Revision 25:10/14/2019
Page 3 of 16
ONEMOJE!ft.
Product Specification Plants) Description
4 B PcrWck MU-x ASTIIlIi D1970 Ft,NV,PA mominal 54-mil thick dual-layer rubberized asphalt
[See Section} waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.19 PolyfstickTU Max AS T D 970 FL,PA,TX Nominal fiQ-mil thick rubberized asphalt waterproofing
TAS Z03 membrane with a 130 gf mz polyester fabric surface
FRSAfTRI April 2O12
4.20 P'o"n=kTU P TAS 163 TX Nominal 130-mil thick rubberized asphalt waterproofing
FRS,WRI April 2O12 membrane,glass-fiberf polyester reinforced,with a
granular surface
4.21 T.U.glus. ASTM D1.970 FL,PA Nominal 80-mil thick rubberized asphalt waterproofing
TA5103 membrane,glass fiber reinforced,with a polyester fabric
FRSF RI April 2012 surface
5. ll,RMMATIONS:
5.1 Tleis�s a ta0ding code evaluation. Neither NEW Ietc.nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any
prood on which this Evaluation Report or previous versions thereof, isfwas used for permitting or design guidance unless
mined sperilneally fear that Mmpose.
5.2 This EvajlLtargon Report is notf€sr use in the ItVHZ
5.3 Fire Classification is not part of this Evatuati.on Report;refer to current Approved Roofing Materials Directory for fire ratings of
this product_
5,4 P'olyyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FRC approval documents. If not listed,a request may be made to the,authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Aitowable Roof Covers:
T►U15 I: ROOF COVER OPTIONS
s k Wood Shakes
Underlaymettt Asphalt Sfifisngtes Nail on Tile Foarn-on Tie metal &shingles slate
Yew Yes Yes yei ves Yes
(ease sheet in Z�Iy srsterrl [ease 5iteet m.2-ply system}
3 Yes Yes
E1astm P Yes Yes Yes Yes
IlBasa Shy in�piy syste�7 (ease Sheet ui 2-p4y sYsreml
Yes Yes No No No
Polaris Rase Ne Siseer 2-Or 24AY sws l
Pci ss 62 Ras- ° No Yes Yes No Na Na
street us zp�s5rs¢e�) tease street in z.Piy syste-)
i Elasex 61'Li Yes. Yes Yes (See 5.5.1) No Yes Yes
Eks#t0deX SG G Yes Yes Yes [sea 55.1) Na Yes Yes
ias�l@ec xGFR Yes Yes NO No Yes Yes
...................
Hora6aavd Oval Fro W _ Yes No Me Yes Yes Yes
KydrjG Wd Tie Ptrz _ Yes yes Yes (See 5.5.1) Yes Yes Yes
We 4iide SA-APP Cain YES yes Yes (See 5.5_1) No Yes Yes
Sheet
—
! Muk Hide Cap Yes yes Yes (See 55.1) No Yes Yes
Fsd x G yes Yes Yes (See 5.5.1) No Yes Yes
l.*ff"6 FR Yes Yes ldn No Yes Yes
FoNflexSA.P Yes Yes Yes (See 5.5.1) No Yes Yes
—._....._._ j
lb[yllex 5A A FR Yes Yes Yes (See 5.5.1) No Yes Yes
'
P'vlYs c.kIR Xe Yes No No No Yes Yes
NEN3D E7 itc _ Evdluation Report P12060.02.09-R25
Ce+Ei,�mdra}.RY,tttienu�sama 3 .ESA` 5t"EornON(2017)FEC Ni]N-HVH2 EVALUATION FL5259-R29
pa%.gbss Roo krcle"merdA:(454)233-1230 Revision 2 5:10/14/2019
Page 4 of 16
NNEMO I etc.
TABLE 1. ROOF.COVER CAPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal &Shingles slate
Polystick MTS Plus Yes Yes No Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
PolystickTU Max No Yes Yes (See 5.5.1) Yes No No
PolystickTU P No Yes Yes (See 5.5.1) No No No
PolystickTU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives J underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE'UNDERLAYMENT COMBINATIONS'-
Florida Product
Adhesive Approval Underlayments
DAP Foam Touch'n Seal StormBond FL14506 PolystickTU Max or PolystickTU Plus
Roof Tiie Adhesive
DowTileBond" FL22525 HydraGua rd Tile Pro,Polyflex SAP,PolystickTU Max,PolystickTU Por
Polystick TU Plus
Elastoflex G TLI,Elastoflex.SG G,HydraGuard Tile Pro,Mule-Hide SA-APP
ICP Adhesives Polyset®AH-160 FL6332 Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex G,Polyflex SA P,
Polyflex SA P FIR,PolystickTU Max,PolystickTU P or PolystickTU Plus
Flastaflex 56 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-
ICP Adhesives Polyset"RTA-1 FL5276 Hide SA-APP Cap Sheet(FIR),Polyflex G,Polyflex SA P,Polyflex SA P PR,
PolystickTU Max,PolystickTU P or PolystickTU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED LINDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Materlal(s)
plywood,OSB,Southern Yellow Pine or Huber
HydraGuard Dual Pro, Deck J (Optional]ASTM D41 Engineered Woods"ZIP System"Panels
HydraGuard Tile Pro, sheathing ASTM D41 structural concrete
Polystick(all variations), self- ASTM C1299 Type II Class 1 polyisocyanurate,ASTM
Mule-Hlde SA-APP Cap adhering Insulation (Optional)ASTM D41 C1289 Type V polyisocyanurate-composite,DensDeck
Sheet,Mule-Hide SA-APP or WB-3000
p Sheet(FIR),Polyflex Prime or SECUROCK Gypsum-Fiber Roof Board
Cap
P Polyflex of P ex Base ASTM D226felt,Elastvhase,Elastobase P or Mule-Hide
Sheet N/A Nail Base
Deck ASTM D41 structural concrete
Elastoflex G TU,Elastoflex hot asphalt Insulation (Optional)ASTM D41 Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board
S6 G or Elastoflex 56 G FIR 8d5e ASTM D226 felt,Elastobase,Elastobase P,Mule-Hide Nail
Sheet N/A Base or Polyglass G2 Base
Deck ASTM D41 structural Concrete
Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 Dens Deck Prime orSECUROCK Gypsum-Fiber Roof Board
applied Base N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
Sheet G2 Base a Polygiass Base
Refer,to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Morn ent Re5i5tanCe Performance.
NEIVIO ETC,LLC. Evaluation Report P12060.0209-R25
Certificate ofRuthorzatron#32455 6rH EDITION(2017)FBC NON-HVH2 EVALUATION FIS259-R29
Polyglass Roof Underlayrnents;(954)233-1230 Revision 25:10/14/2019
Page 5 of 16
ONEMOJeM
5.6.1 Wind Resistance for UnderlaVment Systems in Foam-On Tile Applications;
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012(04-12) and are used in foam-on or mortar-set the applications. Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRl April 2012(04-12), Appendix A,Table 1A or F3C 1609
for determination of design wind loads.
41 Maximum Design Pressure=-52.5 psf:
Deck: ARA rated,7116 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all{)SS joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or PolystickTU Plus,self-adhered.
#2 Maximum Design Pressure=-90 psf:
Deck: Min.15132-inch plywood to rreet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG1D0 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1X"ring shank nails
through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or PolystickTU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga,x 1Y"ring shank nails
through 32 ga.,1-51r diametertin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-135 psf:
Deck: ]vein.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optlona1)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastoflex SA-V overall plywood joints_
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction_
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APR Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick"[U Max,Polystick TU P or Polystick TU Plus,self-adhered.
#7 Maximum Design Pressure=-622.5usf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,LLG Evaluation Report P12060.02.09-1125
Certff ote ofAuthorf2nfion#32455 a EDMON(2U17)FBC NON-HVHZ EVALUATION FL5259-Jt29
Poll Roof underlayments;(954)233-1230 Revisiar 25:10/14/2019
Page 6 of 16
OONEMOIeM
#8 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch DSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga,x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o,c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P orPo[ystickTU Pius,self-adhered.
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga,x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered_
#10 Maximum Design Pressure=-37.5 psf*:
Deck: Min,19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: one(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c,at two(2)equally spaced staggered tenter rows.
Underlayment:ElastoflexG TU or Elastoflex 56 G,applied In full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 318-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch u.c.at the 2-inch wide side laps and 4-inch e.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or PolystickTU Plus,self-adhered or Elastoflex G TU,applied in full mapping of hot asphalt.
#12 Maximum Design Pressure=45 psf*:
Deck- Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional,for use with self-adhering underlayment only)Polystick MTS Pius,self-adhered,
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or PolystickTU Plus,self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt.
#13 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdietion.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.atthe 2-inch wide slde laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
4#14 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0,418 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Rase(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four[4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick
TU P or Pufystick TU Plus,self-adhered.
NEMO UC`LLC. Evaluation Report P12060.02.09-R25
Certificate ofAuthorizotion,#32455 6""EQ171710N(2017)FBC NON-HVHZ EVALUATIIDN FL5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/1412019
Page 7 of 16
NNEMO I etc.
#15 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OS6 sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails with 1-3/8"diametertin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch D.C.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hotasphalt,
#16 Maximum Design Pressure=45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Eiastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied..
#17 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elasto6ase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch c.c,at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Flastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elasto6ase or Mule-Hide Nail Base(poly film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.atthe 3-inch wide side laps and 6-inch o.c.atfour(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underfayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elasto6ase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nalls
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c,atfour(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
4420 Maximum Design Pre55ure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-Inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elasto6ase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: ❑MG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch c.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied,
NENIO FTC,LLC. Evacuation Report P12060.02.09-R25
Certiflcote of Authorization#32455 6'a EDITION R017)FBC NON-HVHZ EVALUATICIN FL5259-R29
Polyglass hoof Underiayments,(954)233-1230 Revision 25:10/14/2019
Page 8 of 16
�NNEMO I etc.
#22 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-frlm top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c,at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100or'ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-ARP Cap Sheet(FR),Polyflex SA P,Polyflex SA P rR,Polystick TU Max,Polystick
TU P or PolystickTU Plus,self-adhered.
#23 Maximum Design Pressure=-60.0 psf;
Deck: APA rated,7116 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex.G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#25 Maximum Design Pressure=-67.5 psf.-
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied Underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c+at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
926 Maximum Design Pressure=-67.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 190'into the ho€es of the plate, parallef to
the width direction of the sheet.
Spacing: 12-inch c.c.at the 4rinch wide side laps and 12-inch o.c.attwo(2)equally spaced staggered center rows.
Primer: (optional)PG100 or ASTM D41 primerapplied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#27 Maximum Design Pressure=-67.5 psf:
Deck: APA rated,19/32 CAT,0-578 in_,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180`into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o_c_at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt.
NEMO ETC,Lt,C.
Evaluation Report P12050.02.09-1125
Cert�ffrote of uthoraortnn#32455 6T'EDITION(2017)r0C NON-H4'HZ EVALUATION FLS259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:1 0/1412 0 19
Page 9of16
ONEmo I etc.
#28 Maximum Design Pressure=-67.5 Psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate, parallel to
the width direction of the sheet_
Spacing: 12-inch o.c,at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-a ppl led.
#29 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_
Base Sheet: Polyglass 62 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast 414 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip 914 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o_c_at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#30 Maximum Design Pressure=-90 psf:
Deck: Min.15132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt ortorch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c,at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap)
Fasteners: ❑MG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Flastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD withTrufast3"Metal Insulation Plates
Spacing: 64nch o.c.atthe 4-inch wide side laps and G-Inch o.c.atthree(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#33 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,CMG#14 HD with OMG 3"Galvalume Steel Plates,CMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.atthe 4-inch wide side laps and 9-inch o.c.atfour(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hotasphalt ortorch-applied or Polyflex G,torch-applied.
##34 Maximum Design Pressure=-90.4 psf-
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 190'into the holes of the plate, parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.atthe 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 orASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick NITS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEM0FK,LEG Evaluation Report P12060.02.09-1125
Certificate of Authorization#32455 6T"EDITION t2017)FSC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 10 of 16
*NEMO I eft.
#35 Maximum Design Pressure=-90.0 Psf:
Deck: APA rated,7/16 CAT,0.413 in.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate Installed 180'into the holes of the plate, parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastaflex S6 G,applied in full mopping of hot asphalt.
#36 Maximum Design Pressure=-90.0 RSf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,0513 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch c.c+at two(2)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
#37 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 4-inch o.c,at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,PolystickTU Max,Pclystick
TU P or PolystickTU Plus,self-adhered.
#38 Maximum Design Pressure=-97.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-irich c.c.atfour(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates,
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mu le-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex 5A P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or PolystickTU Plus,self-adhered.
#39 Maximum Design Pressure=- sf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,0513 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.atthe 4-inch wide side laps and 6-inch o.c.atfour(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#40 Maximum Design Pressure=-97.5 sf:
Deck: APA rated,19/32 CAT,0.578 In.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment Polyflex G,torch-applied.
ff41 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot asphaltortorch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: fi-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex C TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEM0 ETC,.LLG Eval uation Report P12060.02.09-R25
Ceitii tcate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 11vf15
NNEMO I etc.
#42 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c,atthree(3)equally spaced staggered center rows.
Primer: PG100 orASTM D41 primer applied to stress plates.
Base Ply: (0ptiona1)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#43 Maximum Design Pressure=-105.0 psf;
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch a.c.atthe 4-inch wide side laps and 6-inch o.c.atthree(3)equally spaced staggered center rows_
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch c.c.at the 4-inch wide side laps and 6-inch o,c,at three(3)equally spaced staggered center rows.
Underlayment:PolyflexG,tcrch-applied.
#45 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: F3astobase or Mule-Hide Nall Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 5-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS Plus,self-adhered
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick Tl1 Max,Polystick
TU P or Polystick-ru Plus,self-adhered.
#46 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Ju risdiction.
Base Sheet: Elastobase(sanded tap surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.atthe 4-inch wide side laps and 6-inch o,c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hotasphalt or Polyflex G,torch-applied_
#47 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch c.c.atthe 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows_
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
NEMO ETC,LLG Evaluation Report P12060.02.09-R25
Certificate of Authmzation 032455 6'^EDITION(2017)FSC NON-HVH2 EVALUATION F1.5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 12 of 16
OONEMOJetc.
#48 Maximum design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch 0.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: P6100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Pelyflex SA P,Polyflex SA P FP,,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#49 Maximum Design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.579 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#50 Maximum Design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Palyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
5.6.1.1 All other direct-deck, adhered Polyglass Underlayment systems beneath foam-on the systems carry a Maximum Design
Pressure of-45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-79 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLES: ExPosuRELimrrATIONS
Underlayment Maximum Exposure(days)
Elastoflex G TU,HydraGuard Dual Pro,HydraGuard-rile Pro,Polystick MTS Pius,Polystick TU ISOMax,Polystick TU P or Polystick TU Pius
Polystick IR-Xe or Polystick MU-X 90
Elastobase,Flastobase P,Polyglass G2 Base or Palyglass Base 30
180
Elastoflex S6 G,Elastoflex 56 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet (for adhesive-set tile)
(FR),Polyflex G,Polyflex G FR,P0lyflex SA P or Polyflex 5A P FR UNLIMITED
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MU-x has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3, Note 1 of ASTM D1970-15,should be established as to slip resistance_
NEMO ETC,tLC. Evaluation Report P12060.02.09-1125
Certificate efAuthoriration#32455 6`H EDFn0N(20171 FBC NON-HVHZ EVALUAT[ON F15259-1179
Palyglass Roof Underlayments;(9S4)233-1230 Revision 25:10/14/2019
Page 13 of 16
OONEMOjetc.
5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)):
When loading roaftiles an the underlayment in direct-decktile assemblies,the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2- TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECKTILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flastoflex G TU Flat 10-tile stack 7:12
Lugged 8-tile stack(6 over 2) 6:12
Elastotlex 56 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4.12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4.12
Polystick MTS Plus Flat 6-tile stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2) 4:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
Polystick TU Max Lugged 6-tl le stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
PolystickTU P Flat 6-tile stack(4 over 2) 6:12
Lugged &-tile stack(4 over 2) 4:12
PofystickTU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subjectto the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P ar Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA P FR, Mule-
Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot
asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer
underlayment,as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System"from FRSA/TRI April 2012(04-12). Reference is made to Table land Section 5.6.1 herein,coupled with FRSA/TRI April
2012(04-12)Installation Manual.
NEMQETC,LLG Evaluation Report P12Q60.D2.09-R25
Certificate ofAuthorization#32455 6-EDMON(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 14of16
OMEMO I etc.
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR), Polyflex SA P,
Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X,Polystick TU Max,Polystick TU P or Polystick TU Plus:
6.4.1 General:
All seal-lap seams(selvage laps)must befirmly rolled with a in
accordance with Polyglass requirements to ensure full contact' r
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile W .
Pro, align the edge of the top sheet to the end of the glue
pattern(the sheet will overlap the fabric).
r
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements.
6.4.3 Tile Applications excludes HydraGuard Dual Pro Polystick!R-Xe and Polystick MU-X :
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI April 2012(04-12)and
Polyglass published requirements.
For mechanically fastened tile roofing.over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.5.1 herein.
6.4.4 Multi-Ply Undedayment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are
those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is
desired_
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-senile systems. Limits of use are those associated with the top-layer material. This is not a
requirement,but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR-
6.5.1 Flastoflex G TU,Elastoflex S6 G or ElastoflexS6 G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the"Two Ply System"from FRSA/TRl April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
v Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet"
in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D638C, Class M) in the "Single Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap
Sheet"in the"Two Ply System"from FRSA/TR1 April 2012(04-12)beneath mechanically fastened tile roof systems.
NEW ETC,LLC Evaluation Report P12060.02.09-R25
Certi�tAte afRurhorizarion#32455 6�'EDMON(2027)FSC NUN-HVHZ EVALUATION FL5259-1129
Polyglass Roof U n derl ayme nts;(954)233-1230 Revision 25:10/14/2019
Page 15 of 16
ONEMOletc.
6.5.2 For hot-asphalt-applications,ElastoflexGTU,ElastoflexS6G or Elastoflex56 G FRshail be fully asph a It-applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
d Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSAJTRI April 2012(G4-
12)beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options).
V Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012
(04-12)beneath mechanically fastened tile roof systems(Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course_ Side and end laps shall be fully heat-welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge_
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underiayrnent. Refer to Table 2
herein,and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens,as required bythe tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed,such as the use of battens or nail-boards,to prevent tile
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contact the noted CA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to
Section 4 herein for product&production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406;k.chancellcr@us.ul.com
-END OF EVALUATION REPORT-
NEM0 ETC,LLC. Evaluation Report P12060.02.69-1125
Cerffcate ofAuthonzation#32455 6`x EWTION(2012)FBC NUN-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments;(954)233-2230 Revision 25:10/14/2019