HomeMy WebLinkAbout_20200827154853OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
LOCATION/SITE
ADDRESS:
6642 Alemendra St
Fort Pierce, FL 34951
PERMIT # 2007-0703
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Product Approval for Flamm of Ridge Vent
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: C0006984 ST. LUCIE CO CERT. #:
BUSINESS NAME: Panda contractors
QUALIFIERS NAME: Sergio zeligman
ADDRESS: 4560 US Highway 1
CITY: Vero Beach STATE: Fl ZIP: 32967
PHONE (DAYTIME): 772-231-5959 FAX:
OWNER/BUILDER INFORMATION:
NAME: Thomas Dutcher
ADDRESS: 6641 Alemendra ST
CITY: Fort Pierce STATE: Fl ZIP: 34951
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9/23/09
Revised 06/30/17
STATE: ZIP:
FAX:
_ 1
c_.
Spceclalty Structural IEnglnecerinq CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report
FLAMCO "Off -Ridge Vent"
Roof Vent
Manufacturer:
Florida Metal Products, Inc.
6940 Stuart Avenue
Jacksonville, Fl 32254
for
Florida Product Approval
# FL 21580.1
Florida Building Code 5th Edition (2014)
Method: 2 - B
Category: Roofing
Sub - Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Name:
Product Description:
Attached To:
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 16-143-ORV-ER
Date: 12 / 20 / 16
Contents:
Evaluation Report Pages 1-9
"Off -Ridge Vent"
Roof Vent
Wood Deck
CBUCK, Inc. • Palm Beach County, Florida
Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net
Mailing Address: 2637 E. Atlantic Blvd, #34069, Pompano, FL 33062
Digitally signed by James L. Buckner, P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
61G36-2` ",111111111///
No 31242 •'*
A : LU
��T'•. STATE OF ��
ClT F40RIDP,.' C\
11116.12.2814:8853 -85'W
FL #: FL 21580.1
Date: 12/20/16
;�..�- �s�..I ReportNo.: 16-143-ORV-ER
Page 2 of 6
Speclalty Structural Engineering
1.0 Manufacturer: Florida Metal Products, Inc. dba FLAMCO
6940 Stuart Avenue
Jacksonville, Florida 32254
(800)634-8400
htta://flamco.com
2.0 Manufacturing Plant: Jacksonville, Florida
3.0 Product:
3.1 Product Name: "Off -Ridge Vent'
3.2 Product Description: Roof Vent
4.0 Evaluation Scope:
4.1 Compliance with the following
Florida Building Code 5th Edition (2014)
CBUCK, Inc. Certificate of Authorization #8064
4.2 Evaluation Method:
Florida Product Approval Rule 61G20-3.005 (2) (b)
4.3 Evaluation Classification:
Category: Roofing
Sub Category: Roofing Accessories that are an Integral part of the Roofing System
4.4 Properties Evaluated
Structural (Wind Resistance) Properties
4.5 Limits of Evaluation:
This product assembly evaluation is limited to compliance with section 4.1 to section 4.4 of
this report.
5.0 Evaluated Uses:
FLAMCO "Off -Ridge Vent' is used as a roof ventilator.
6.0 Product Assembly Description:
6.1 General:
The FLAMCO "Off -Ridge Vents" are low profile, off -ridge roof vent for pitched roofs fabricated
from 26 gauge, G-90 primed, galvanized steel with a galvanized steel mesh covering mechanically
attached to Plywood Deck.
7.0 General Assembly as Evaluated:
Refer to section 15.0 of this report for product assembly components/materials & standards.
8.0 Support System:
(Design of support system is outside the scope of this evaluation.)
8.1 Type: Wood Deck
8.2 Description: 15/32' (min.) or greater plywood, or
Wood plank deck (based on minimum density/specific gravity of 0.42)
9.0 Slope:
Minimum slope shall be 2:12. (and in compliance with FBC Chapter 15 based on the type of roof covering,
applicable code sections and in accordance with manufacturer's recommendations.)
FL #: FL 21580.1
_ Date: 12/20/16
Report No.: 16-143-ORV-ER
Page 3 of 6
Speclalftj Structural 6=nQlr-ki?PrInQ CBUCK, Inc. Certificate of Authorization #8064
10.0 Performance:
10.1 Wind Resistance:
Table A
Allowable Loads
Design Uplift Pressure 1 -46 PSF
Notes:
1. Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.
11.0 Performance Standard:
The following test protocols were performed to demonstrate compliance with the intent of the code:
11.1 ASTM E330-02 — Standard Test Method for Structural Performance of Exterior Windows, Curtain
Walls, and Doors and by Uniform Static Air Pressure Difference
12.00ode Compliance:
12.1 The product assembly described herein has demonstrated compliance with the Florida Building Code
5th Edition (2014) for the properties evaluated.
13.0 Limitations and Conditions of Use:
13.1 Design of support system is outside the scope of this report. Support shall be structural framing
members complying with the code and shall be designed by others.
13.2 Scope of "Limitations and Conditions of Use" for this evaluation:
This evaluation report for "State Approval" contains technical documentation, specifications and
installation method(s) which include "Limitations and Conditions of Use" throughout the report in
accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the
authority to approve products under "State Approval".
13.3 Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local
authorities having jurisdiction in accordance with the alternate methods and materials authorized in
the Code". Any modification of the product as evaluated in this report and approved by the Florida
Building Commission is outside the scope of this evaluation and will be the responsibility of others.
13.4 This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with
Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building
Commission approval for the listed code related criteria. This report by lames Buckner, P.E. and
CBUCK Engineering is not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific or permit design.
13.5 All metal components and fasteners shall be corrosion resistant in accordance with FBC, including
but limited to Sections 1504.3.2, 1506.6 and 1507.4.4.
13.6 Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this
evaluation.
13.7 Refer to applicable building code section for ventilation requirements.
13.8 This report does not evaluate the use of this product assembly as described in this report for use in
the High Velocity Hurricane Zone code section. (Dade & Broward Counties)
14.0 Quality Assurance:
The manufacturer has demonstrated compliance of products in accordance with the Florida
Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program
audited by an approved quality assurance entity through Keystone Certifications, Inc., (FBC
Organization #QUA (D:1824). I ,
FL #: FL 21580.1
�� Date: 12/20/16
J �
( j I --C Engin NnQ ReportNo.: 16-143-ORV-ER
';1 Page 4 of 6
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8054
15.0 System/Components
15.1 "Off Ridge Vent"
15.1.1 Material: Steel
15.1.2 Thickness:
26 gauge (min.)
15.1.3 Yield Strength:
40 ksi min.
15.1.4 Corrosion Resistance:
In compliance with FBC Section 1507.4.3:
ASTM A792 coated, or ASTM A653 G90 galvanized steel
15.1.5 Overall Product Dimensions (nominal):
15.1.5.1 Length(s):
2', 4', 6' and 8' (max.)
15.1.5.2 Width:
23" (max.)
15.1.5.3 Height:
4-3/4" and 8-1/2" (max.)
15.2 Fastener:
15.2.1 Base Fastener:
Attaches Roof Vent to Deck
15.2.1.1 Type: Smooth or Ring Shank Roofing Nails
15.2.1.2 Size: 11 gauge x 2" (Long)
15.2.1.3 Corrosion Resistance: Per FBC Section 1506.5
15.2.1.4 Standard: Per ASTM F 1667
15.3 Roof Adhesive:
15.3.1 Type: Standard Heavy bodied Flashing Cement
15.3.2 Description: Asbestos -free asphalt based roof cement
15.3.3 Application Size: 1/4" thick (min.)
15.3.4 Standard: Per ASTM D 4586 Type I
16.0 Installation Method:
(Refer to installation method at the end of this evaluation report.)
Prepare deck opening by trimming any shingles or tiles & existing nails that may interfere with ridge vent
installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should
be a 1/4" thick and extend 2" onto roof underlayment. (Install cement in compliance with manufacturer's
installation guidelines.) Position vent base flange beneath loosened shingles and align with deck opening.
Attach the unit side flanges to deck with fasteners per Section 15.2.1 spaced 4" o.c. and 1" from each
end. Apply Roofing Cement to exposed fastener heads. Minimum fastener penetration thru bottom of
support, 3/16".
The FLAMCO "Off -Ridge Vent" shall be installed in compliance with the installation method listed in this
report and applicable code sections of FBC 5th Edition (2014). The installation method described herein
is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17.0 Evaluation Reference Data:
17.1 ASTM E330-02 Uniform Static Air Pressure Difference Test
By American Test Lab of South Florida (ATL) (FBC Organization #TST ID: 3782)
Project #16-6647, Lab #9124, Dated: 11/09/16
17.2 Quality Assurance
By Keystone Certifications, Inc. (FBC Organization #: QUA 1824)
Licensee #440
17.3 Engineering Analysis
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
17.4 Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 21580.1
Date: 12/20/16
ReportNo.: 16-143-ORV-ER
Page 5 of 6
SppcldltLj Structural EnglnPerinc2 CBUCK, Inc. Certificate ofAuthorization #8064
Installation Method
FLAMCO
"Off -Ridge Vent" Roof Vent
1" from Edge
"Off -Ridge Vent"
Isometric View
4' o.c. Typical, Maximum
Fastener is 11 Gauge Galvanized Ring Shank Roofing Nail
Flange
Top Plan View
(Typical Fastening Pattern)
(Not to Scale)
FL #: FL 21580.1
Date: 12/20/16ReportNo.: 16-143-ORV-ER
Page 6 of 6
SpPCidlty STructurcsl Englneprinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
FLAMCO
"Off -Ridge Vent" Roof Vent
FLAMCO Off -Ridge Vent
11 Gauge Smooth or
Ring Shank Nail
v Plywood peck %
Higher SI �
Lowe )Slope Rain Baffles (Interior) (Back)
Typical Assembly
Section View
(Not to Scale)