Loading...
HomeMy WebLinkAbout102 NW Airoso - Flintlastick GTA Torch DownENGINEER EVALUATE: TEsI Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 CONSULT CERTIFY CertainTeed Corporation Evaluation Report C40710.12.13-R6 20 Moores Road FL167O9-R6 Malvern, PA 19355 Date of Issuance: 12/02/2013 (610) 651-5847 Revision 6: 06/20/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: FlintlastiOl Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus 14-page Appendix. Prepared by: Robert J.M. Nieminen P.E. ^6 a The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 ''' "n s r •; �r,r Nieminen, P.E. on 06(20/2019. This does not serve as an >n.,. electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2, NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro ert --� Y Standard Year 2011 1504.3.1 Wind FM 4474 FM 4470 2012 1504.7 1507.11.2 Impact Physical Properties y ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 2011 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2009 1507,11.2 Physical Properties ASTM D6509 1519.11 Attachment Requirements RAS 117 1995 Entit Examination Reference Date ERD (TST6049) Physical Properties C7290.01.08 01/16/2008 ERD (TST6049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 3519.12.03-R1 04/15/2011 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470 CTR-SC9920.01.16-RI 01/20/2016 FM (TST1867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20HA-001 01/04/2006 MTI (TST2508) Physical properties AX31G8A 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX31GSF 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-2 09/21/2018 PRI (TST5878) Physical Properties CTC-032-02-01 01/16/2008 PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-093-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012 PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013 PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation 03/09/2017 NEMO ETC, LLC Evaluation Report C40710.12.13-R6 Certificate of Authorization#32455 6'"'�_DiTif.)NI (2C%1.7)H%NON-W"H17,EVALUATION rL16709-R6 CertainTeed Flintlastic" Modified Bitumen Roof Systems; (610) 651-5847 Revision 6: 06/20/2019 Page 2 of 4 NEMO ( etc. This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following r,..t;.,Tml .. roductc make un the subiect systems. Specification Type Product Reference Grade Type Flintlastic' SA NailBase ASTM D4601 N/A 11 Base Sheets Ply Sheets Base/Ply Membranes (APP) GiasbaseT" Base Sheet ASTM D4601 N/A it All Weather/Empire'" Base FlexiglasT" Base ASTM D4601 ASTM D4601 N/A N/A II li Flintlastic- Base 20 ASTM D4601 N/A II Flintlastic Poly SMS Base Sheet Yosemite" Venting Base Flintgias® Ply 4 ASTM D4601 ASTM D4897 ASTM D2178 N/A N/A N/A 11 II IV Flintgias® Premium Ply 6 Flintlastic® APP Base T ASTM D2178 ASTM D6509 N/A N/A VI N/A Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM 06222 S I Cap Membranes (APP) Flintlastic® STA ASTM 06222 S I Flintlastic® STA Plus ASTM D6222 S I • .,.. - ASTM D6222 G I Flintlastic® GTA CoolStar'" ASTM D6222 G I Flintlastic® GTA-FR ASTM D6222 G I Flintlastic® GTA-FR CoolStar`" ASTM D6222 G I Base/Ply Membranes (SBS) Flintlastic' SA PlyBase ASTM D1970 N/A N/A Black Diamond® Base Sheet ASTM D1970 N/A N/A Flintlastic" SA Mid Ply ASTM D6163 S I Flintlastic" Ultra Glass SA ASTM D6163 S I Flintlastic' Base 20 ASTM D6163 S Flintlastic Base 20 T ASTM D6163 S i Flintlastic' Ultra Poly SMS Base Sheet ASTM 06164 S I Cap Membranes (SBS) Flintlastic" FR Dual Cap ASTM D6162 G I Flintlastic' SA Cap FR ASTM D6163 G I Flintlastic` SA Cap FR CoolStarTM ASTM D6163 G I Flintlastic' FR Cap 30 ASTM D6163 G I Flintlastic" FR Cap 30 CoolStar`" ASTM D6163 G I Flintlastic' FR Cap 30 T ASTM D6163 G 1 Flintlastic* FR Cap 30 T CoolStarTM ASTM D6163 G I Flintlastic' SA Cap ASTM D6164 G I Flintlastic` SA Cap CoolStarTM ASTM D6164 G I Flintlastic FR-P ASTM D6164 G l Flintlastic FR-P CoolStarTM ASTM D6164 G I Flintlastic' GMS ASTM D6164 G I Flintlastic GMS CoolStarTM' ASTM D6164 G I Flintlastic GTS-FR ASTM D6164 G Ii Flintlastic* GTS-FR CoolStarTM ASTM D6164 G 11 Flintlastic` Premium FR-P ASTM D6164 G II Flintlastic' Premium FR-P CoolStar" ASTM D6164 G II NEMO ETC, LLC Evaluation Report C40710.12.13-R6 Cerrificare of Aorhoriearior, #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION ="L16709-R6 CertainTeed Flintlastic® Modred Bitumen Roof Systems; (610) 651-5847 Revision 6: 06/20/2019 Page 3 of 4 ONEMOletc. ner of 5.1 This is a building code eval at on this IEvaluation�ReportETC, 0 L or previous ers ons thereof, C nor Robert Nieminen, P.E. r is/was used for 1perrm tt permitting or Record for any project on design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Havi documentation, Load resistance of the roof deck shall be documented through proper codified and/or FBC App rova5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.6 The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. This is already addressed in the Appendix tables via "N/A" reference if the baseline system is "Not Applicable" to Zone 1 design pressure requirements. 5.7 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105, 5.8 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.9 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO ETC, LLC Evaluation Report C40710.12.13-R6 Certificate oJAuthodzation#32455 6'-"EDITION (2017) FBC NON-' . . CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 6: 06/20/2019 Page 4 of 4