HomeMy WebLinkAbout102 NW Airoso - Flintlastick GTA Torch DownENGINEER EVALUATE: TEsI
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
CONSULT CERTIFY
CertainTeed Corporation Evaluation Report C40710.12.13-R6
20 Moores Road FL167O9-R6
Malvern, PA 19355 Date of Issuance: 12/02/2013
(610) 651-5847 Revision 6: 06/20/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: FlintlastiOl Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus 14-page Appendix.
Prepared by:
Robert J.M. Nieminen P.E. ^6 a The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983 ''' "n s r
•; �r,r Nieminen, P.E. on 06(20/2019. This does not serve as an
>n.,. electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2, NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub -Category: Modified Bitumen Roof Systems
Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed Corporation,
have demonstrated compliance with the following sections of the 611 Edition (2017) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
Section
Pro ert
--� Y
Standard
Year
2011
1504.3.1
Wind
FM 4474
FM 4470
2012
1504.7
1507.11.2
Impact
Physical Properties
y
ASTM D6162
2008
1507.11.2
Physical Properties
ASTM D6163
2008
2011
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2009
1507,11.2
Physical Properties
ASTM D6509
1519.11
Attachment Requirements
RAS 117
1995
Entit
Examination
Reference
Date
ERD (TST6049)
Physical Properties
C7290.01.08
01/16/2008
ERD (TST6049)
Physical Properties
C10080.09.08
09/04/2008
ERD (TST6049)
FM 4470/4474
C8370.08.08-R1
10/05/2009
ERD (TST6049)
FM 4470/4474
C30310.12.09
12/17/2009
ERD (TST6049)
FM 4470/4474
C30560.03.10
03/18/2010
ERD (TST6049)
FM 4470/4474
3519.12.03-R1
04/15/2011
ERD (TST6049)
Physical Properties
C42110.08.12
08/13/2012
ERD (TST6049)
FM 4470/4474
C46090.11.13-A
11/20/2013
ERD (TST6049)
FM 4470
CTR-SC9920.01.16-RI
01/20/2016
FM (TST1867)
FM 4470/4474
3048520
09/19/2013
MTI (TST2508)
Physical properties
DX08C4A
03/22/2004
MTI (TST2508)
Physical properties
DX20E3A
03/22/2004
MTI (TST2508)
Physical properties
DX20HA-001
01/04/2006
MTI (TST2508)
Physical properties
AX31G8A
08/21/2008
MTI (TST2508)
Physical properties
AX31G8D
09/05/2008
MTI (TST2508)
Physical properties
AX31GSF
06/05/2009
MTI (TST2508)
Physical properties
AX21G8C
01/28/2011
NEMO (TST6049)
FM 4474
4L-CTR-18-002.09.18-2
09/21/2018
PRI (TST5878)
Physical Properties
CTC-032-02-01
01/16/2008
PRI (TST5878)
Physical Properties
CTC-034-02-01
11/24/2008
PRI (TST5878)
Physical Properties
CTC-066-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-067-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-068-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-070-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-071-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-093-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-116-02-01
04/03/2012
PRI (TST5878)
Physical Properties
CTC-183-02-01
10/04/2013
PRI (TST5878)
Physical Properties
CTC-259-02-01
12/11/2015
UL, LLC. (QUA9625)
Quality Assurance
Service Confirmation
03/09/2017
NEMO ETC, LLC
Evaluation Report C40710.12.13-R6
Certificate of Authorization#32455
6'"'�_DiTif.)NI (2C%1.7)H%NON-W"H17,EVALUATION
rL16709-R6
CertainTeed Flintlastic" Modified
Bitumen Roof Systems; (610) 651-5847
Revision 6: 06/20/2019
Page 2 of 4
NEMO ( etc.
This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed
Corporation published installation instructions and the Limitations / Conditions of Use herein. The following
r,..t;.,Tml .. roductc make un the subiect systems.
Specification
Type Product Reference Grade Type
Flintlastic' SA NailBase
ASTM D4601
N/A
11
Base Sheets
Ply Sheets
Base/Ply Membranes (APP)
GiasbaseT" Base Sheet
ASTM D4601
N/A
it
All Weather/Empire'" Base
FlexiglasT" Base
ASTM D4601
ASTM D4601
N/A
N/A
II
li
Flintlastic- Base 20
ASTM D4601
N/A
II
Flintlastic Poly SMS Base Sheet
Yosemite" Venting Base
Flintgias® Ply 4
ASTM D4601
ASTM D4897
ASTM D2178
N/A
N/A
N/A
11
II
IV
Flintgias® Premium Ply 6
Flintlastic® APP Base T
ASTM D2178
ASTM D6509
N/A
N/A
VI
N/A
Flintlastic® STA
ASTM D6222
S
I
Flintlastic® STA Plus
ASTM 06222
S
I
Cap Membranes (APP)
Flintlastic® STA
ASTM 06222
S
I
Flintlastic® STA Plus
ASTM D6222
S
I
• .,.. -
ASTM D6222
G
I
Flintlastic® GTA CoolStar'"
ASTM D6222
G
I
Flintlastic® GTA-FR
ASTM D6222
G
I
Flintlastic® GTA-FR CoolStar`"
ASTM D6222
G
I
Base/Ply Membranes (SBS)
Flintlastic' SA PlyBase
ASTM D1970
N/A
N/A
Black Diamond® Base Sheet
ASTM D1970
N/A
N/A
Flintlastic" SA Mid Ply
ASTM D6163
S
I
Flintlastic" Ultra Glass SA
ASTM D6163
S
I
Flintlastic' Base 20
ASTM D6163
S
Flintlastic Base 20 T
ASTM D6163
S
i
Flintlastic' Ultra Poly SMS Base Sheet
ASTM 06164
S
I
Cap Membranes (SBS)
Flintlastic" FR Dual Cap
ASTM D6162
G
I
Flintlastic' SA Cap FR
ASTM D6163
G
I
Flintlastic` SA Cap FR CoolStarTM
ASTM D6163
G
I
Flintlastic' FR Cap 30
ASTM D6163
G
I
Flintlastic" FR Cap 30 CoolStar`"
ASTM D6163
G
I
Flintlastic' FR Cap 30 T
ASTM D6163
G
1
Flintlastic* FR Cap 30 T CoolStarTM
ASTM D6163
G
I
Flintlastic' SA Cap
ASTM D6164
G
I
Flintlastic` SA Cap CoolStarTM
ASTM D6164
G
I
Flintlastic FR-P
ASTM D6164
G
l
Flintlastic FR-P CoolStarTM
ASTM D6164
G
I
Flintlastic' GMS
ASTM D6164
G
I
Flintlastic GMS CoolStarTM'
ASTM D6164
G
I
Flintlastic GTS-FR
ASTM D6164
G
Ii
Flintlastic* GTS-FR CoolStarTM
ASTM D6164
G
11
Flintlastic` Premium FR-P
ASTM D6164
G
II
Flintlastic' Premium FR-P CoolStar"
ASTM D6164
G
II
NEMO ETC, LLC Evaluation Report C40710.12.13-R6
Cerrificare of Aorhoriearior, #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION ="L16709-R6
CertainTeed Flintlastic® Modred Bitumen Roof Systems; (610) 651-5847 Revision 6: 06/20/2019
Page 3 of 4
ONEMOletc.
ner of
5.1 This is a building code eval at on this IEvaluation�ReportETC, 0 L or previous ers ons thereof, C nor Robert Nieminen, P.E. r is/was used for 1perrm tt permitting or
Record for any project on
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members
shall be in accordance with FBC requirements to the satisfaction of the Authority Havi documentation, Load
resistance of the roof deck shall be documented through proper codified and/or FBC App
rova5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1511.
5.6 The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC Chapter 16. This is already addressed in the Appendix tables via "N/A"
reference if the baseline system is "Not Applicable" to Zone 1 design pressure requirements.
5.7 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing
deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application
Standard TAS 105,
5.8 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111,
except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3).
5.9 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.
NEMO ETC, LLC Evaluation Report C40710.12.13-R6
Certificate oJAuthodzation#32455 6'-"EDITION (2017) FBC NON-' . .
CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 6: 06/20/2019
Page 4 of 4