HomeMy WebLinkAboutTruss EngineeringLumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job WRMSBM1674B
Page 1 of 2
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946Site Information:
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block:Model: BERMUDA 1674
Subdivision: Address: MORNINGSIDE, FORT PIERCE
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-10 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 34 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
The truss drawing(s) referenced have been prepared by Alpine Engineered Products, Inc. under my direct supervision based on the parameters provided by A-1 Roof Trusses, Ltd.
Truss Design Engineer's Name: Rama Pranav Kristam
My license renewal date for the state of Florida is February 28,2021.
NOTE: The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the building
designer, per ANSI/TPI-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction
documents (also referred to at times as 'Structural Engineering Documents') provided by the Building
Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Rama Pranav Kristam PE by [A1 Roof Trusses or
specific location]. These TDDs (also referred to at times as 'Structural Delegated'
Engineering Documents') are specialty structural component designs and may be part of the project's
deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibility for the design of the single Truss depicted on the TDD only. The Building Designer is
responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all related notes. Rama Pranav Kristam, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
No.Seq #Truss Name Date
1 2671 A01 8/20/20
2 2589 A02 8/20/20
3 2584 A03 8/20/20
4 4357 A04 8/20/20
5 2599 A05 8/20/20
6 2683 A06 8/20/20
7 2611 A07 8/20/20
8 2621 A08 8/20/20
9 2643 A09 8/20/20
10 2511 A10 8/20/20
11 2470 A11 8/20/20
12 2513 A12 8/20/20
No.Seq #Truss Name Date
13 2719 A13 8/20/20
14 2650 A14 8/20/20
15 2656 A15 8/20/20
16 4503 B01 8/20/20
17 2647 B02E 8/20/20
18 2668 C01 8/20/20
19 2674 C02 8/20/20
20 2665 C03 8/20/20
21 2680 CJ1 8/20/20
22 2521 CJ1A 8/20/20
23 2522 CJ3 8/20/20
24 2523 CJ3A 8/20/20
No.Seq #Truss Name Date
25 2704 CJ5 8/20/20
26 2713 CJ5P 8/20/20
27 2707 HJ7 8/20/20
28 2537 HJ7S 8/20/20
29 2527 J3GE 8/20/20
30 2701 J7 8/20/20
31 2529 J7C 8/20/20
32 2716 J7P 8/20/20
33 2695 V01 8/20/20
34 2698 V02 8/20/20
35 STDL01 STD. DETAIL 8/20/20
36 STDL02 STD. DETAIL 8/20/20
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
RE: Job WRMSBM1674B
Page 2 of 2
No.Seq #Truss Name Date
37 STDL03 STD. DETAIL 8/20/20
38 STDL04 STD. DETAIL 8/20/20
39 STDL05 STD. DETAIL 8/20/20
40 STDL06 STD. DETAIL 8/20/20
41 STDL07 STD. DETAIL 8/20/20
42 STDL08 STD. DETAIL 8/20/20
43 STDL09 STD. DETAIL 8/20/20
44 STDL10 STD. DETAIL 8/20/20
45 STDL11 STD. DETAIL 8/20/20
46 STDL12 STD. DETAIL 8/20/20
47 STDL13 STD. DETAIL 8/20/20
48 STDL14 STD. DETAIL 8/20/20
49 STDL15 STD. DETAIL 8/20/20
50 STDL16 STD. DETAIL 8/20/20
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T2 2x4 SP M-30;
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W1 2x4 SP 2400f-2.0E;
W6 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.77 25.56
BC 75 2.80 10.89
BC 92 10.92 18.60
BC 112 18.68 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S 707 /- /- /384 /330 /418
T 1546 /- /- /794 /535 /-
H 797 /- /- /558 /348 /-
Wind reactions based on MWFRS
S Brg Width = 7.6 Min Req = 1.5
T Brg Width = 7.6 Min Req = 1.8
H Brg Width = 7.6 Min Req = 1.5
Bearings S, T, & H are a rigid surface.
Bearings S, T, & H require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 27 0
B - S 2209 -2316
C - D 667 -986
D - E 289 -112
Chords Tens. Comp.
E - F 313 -109
F - G 460 -622
G - H 607 -1147
H - I 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
R - Q 819 -264
Q - P 28 -31
O - N 992 -326
M - L 466 -127
Chords Tens. Comp.
L - K 957 -431
K - J 957 -431
J - H 959 -430
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - R 3323 -1661
R - B 3660 -2032
C - Q 324 -643
C - O 609 -252
Q - O 1077 -302
O - P 0 -211
O - D 321 -101
Webs Tens. Comp.
D - N 414 -1208
E - N 379 -547
N - M 504 -1041
M - F 222 -699
F - L 441 -115
L - G 349 -564
G - J 205 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.381 B 597 360
VERT(CL): 0.719 B 316 240
HORZ(LL): 0.174 B - -
HORZ(TL): 0.328 B - -
Creep Factor: 2.0
Max TC CSI: 0.822
Max BC CSI: 0.978
Max Web CSI: 0.973
Wgt: 207.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A01
Truss Type
COMN
Qty
1
Ply
1 2671
08/24/2020
18'3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
9'9"4 15'9"8 12'5"4
11'0"6 7'4"4 19'7"61'4"1'4"
38'
1'4"
4"3
2'4"3'6'6"137'1"12(a)
(a)
A
B
C D E F
G
H
I
JKLM
N
OPQR
S
T
6
12
3X3
3X4
3X10
2X4(R)
3X3
3X3
5X8
3X4
6X6
1.5X3
3X4 1.5X3
4X6(R)
3X6(R)
5X6
3X4 3X6
3X4
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T2 2x4 SP M-30;
Bot chord 2x4 SP #2
Webs 2x4 SP #3 W1 2x4 SP 2400f-2.0E;
W6 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.77 25.56
BC 75 2.80 10.89
BC 92 10.92 18.60
BC 112 18.68 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S 707 /- /- /384 /330 /418
T 1546 /- /- /794 /535 /-
H 797 /- /- /558 /348 /-
Wind reactions based on MWFRS
S Brg Width = 7.6 Min Req = 1.5
T Brg Width = 7.6 Min Req = 1.8
H Brg Width = 7.6 Min Req = 1.5
Bearings S, T, & H are a rigid surface.
Bearings S, T, & H require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 27 0
B - S 2209 -2316
C - D 667 -986
D - E 289 -112
Chords Tens. Comp.
E - F 313 -109
F - G 460 -622
G - H 607 -1147
H - I 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
R - Q 819 -264
Q - P 28 -31
O - N 992 -326
M - L 466 -127
Chords Tens. Comp.
L - K 957 -431
K - J 957 -431
J - H 959 -430
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - R 3323 -1661
R - B 3660 -2032
C - Q 324 -643
C - O 609 -252
Q - O 1077 -302
O - P 0 -211
O - D 321 -101
Webs Tens. Comp.
D - N 414 -1208
E - N 379 -547
N - M 504 -1041
M - F 222 -699
F - L 441 -115
L - G 349 -564
G - J 205 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.381 B 597 360
VERT(CL): 0.719 B 316 240
HORZ(LL): 0.174 B - -
HORZ(TL): 0.328 B - -
Creep Factor: 2.0
Max TC CSI: 0.822
Max BC CSI: 0.978
Max Web CSI: 0.973
Wgt: 207.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A01
Truss Type
COMN
Qty
1
Ply
1 2671
08/24/2020
18'3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
9'9"4 15'9"8 12'5"4
11'0"6 7'4"4 19'7"61'4"1'4"
38'
1'4"
4"3
2'4"3'6'6"137'1"12(a)
(a)
A
B
C D E F
G
H
I
JKLM
N
OPQR
S
T
6
12
3X3
3X4
3X10
2X4(R)
3X3
3X3
5X8
3X4
6X6
1.5X3
3X4 1.5X3
4X6(R)
3X6(R)
5X6
3X4 3X6
3X4
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x6 SP 2400f-2.0E;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Lt Wedge: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.31 23.36
BC 26 0.15 2.30
BC 71 2.19 18.16
BC 76 18.16 37.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
T 1437 /- /- /761 /551 /222
I 1519 /- /- /882 /591 /-
Wind reactions based on MWFRS
T Brg Width = 7.6 Min Req = 1.7
I Brg Width = 7.6 Min Req = 1.8
Bearings T & I are a rigid surface.
Bearings T & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 409 -600
B - C 1477 -3389
C - D 1290 -2760
D - E 1407 -2859
E - F 1403 -2850
Chords Tens. Comp.
F - G 1033 -2054
G - H 1007 -2071
H - I 1175 -2657
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - S 0 0
B - R 3233 -1185
R - Q 3231 -1184
Q - P 3231 -1184
P - N 2366 -785
Chords Tens. Comp.
O - M 15 -8
M - L 2290 -923
L - K 2290 -923
K - I 2292 -922
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
R - C 81 -62
C - P 503 -1035
D - P 607 -206
D - N 596 -277
E - N 255 -352
N - O 63 0
Webs Tens. Comp.
N - M 1935 -675
N - F 1483 -546
M - F 186 -472
M - H 349 -603
H - K 246 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.428 S 999 360
VERT(CL): 0.810 S 553 240
HORZ(LL): 0.319 K - -
HORZ(TL): 0.604 K - -
Creep Factor: 2.0
Max TC CSI: 0.974
Max BC CSI: 0.960
Max Web CSI: 0.737
Wgt: 214.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A02
Truss Type
HIPS
Qty
1
Ply
1 2589
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
11'7"12 12'0"8 14'3"12
2'7"10 15'8"8 19'7"14 1'4"
1'4"
4"3
2'4"7'6"18'1"A
B
C
D E F
G H
I
J
KLM
N
O
PQR
ST
6
12
3X4(A1)
3X8
5X6
1.5X3
3X4
4X6
6X6
3X4
1.5X3
6X8
1.5X4 4X10
6X6
3X6
3X6
3X4
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x6 SP 2400f-2.0E;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Lt Wedge: 2x4 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.31 23.36
BC 26 0.15 2.30
BC 71 2.19 18.16
BC 76 18.16 37.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
T 1437 /- /- /761 /551 /222
I 1519 /- /- /882 /591 /-
Wind reactions based on MWFRS
T Brg Width = 7.6 Min Req = 1.7
I Brg Width = 7.6 Min Req = 1.8
Bearings T & I are a rigid surface.
Bearings T & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 409 -600
B - C 1477 -3389
C - D 1290 -2760
D - E 1407 -2859
E - F 1403 -2850
Chords Tens. Comp.
F - G 1033 -2054
G - H 1007 -2071
H - I 1175 -2657
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - S 0 0
B - R 3233 -1185
R - Q 3231 -1184
Q - P 3231 -1184
P - N 2366 -785
Chords Tens. Comp.
O - M 15 -8
M - L 2290 -923
L - K 2290 -923
K - I 2292 -922
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
R - C 81 -62
C - P 503 -1035
D - P 607 -206
D - N 596 -277
E - N 255 -352
N - O 63 0
Webs Tens. Comp.
N - M 1935 -675
N - F 1483 -546
M - F 186 -472
M - H 349 -603
H - K 246 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.428 S 999 360
VERT(CL): 0.810 S 553 240
HORZ(LL): 0.319 K - -
HORZ(TL): 0.604 K - -
Creep Factor: 2.0
Max TC CSI: 0.974
Max BC CSI: 0.960
Max Web CSI: 0.737
Wgt: 214.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A02
Truss Type
HIPS
Qty
1
Ply
1 2589
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
11'7"12 12'0"8 14'3"12
2'7"10 15'8"8 19'7"14 1'4"
1'4"
4"3
2'4"7'6"18'1"A
B
C
D E F
G H
I
J
KLM
N
O
PQR
ST
6
12
3X4(A1)
3X8
5X6
1.5X3
3X4
4X6
6X6
3X4
1.5X3
6X8
1.5X4 4X10
6X6
3X6
3X6
3X4
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.95 18.99
BC 120 0.11 15.82
BC 120 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /765 /378 /235
I 1512 /- /- /896 /379 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 408 -622
B - C 1174 -2742
C - D 1181 -2412
D - E 1179 -2322
E - F 1178 -2317
Chords Tens. Comp.
F - G 961 -1891
G - H 932 -1911
H - I 1129 -2605
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2509 -826
Q - P 2506 -820
P - N 2055 -618
O - M 13 -6
Chords Tens. Comp.
M - L 2235 -871
L - K 2235 -871
K - I 2237 -869
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 197 0
C - P 399 -804
D - P 628 -292
D - N 413 -191
E - N 153 -202
N - O 5 0
Webs Tens. Comp.
N - M 2049 -659
N - F 1500 -481
M - F 287 -875
M - H 402 -719
H - K 293 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.330 C 999 360
VERT(CL): 0.617 C 723 240
HORZ(LL): 0.236 K - -
HORZ(TL): 0.443 K - -
Creep Factor: 2.0
Max TC CSI: 0.593
Max BC CSI: 0.638
Max Web CSI: 0.781
Wgt: 226.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A03
Truss Type
HIPS
Qty
1
Ply
1 2584
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
13'7"12 8'0"8 16'3"12
18'4"8 19'7"8 1'4"
1'4"
4"3
2'4"8'6"19'1"(a)
(a)
A
B
C
D E F
G H
I
J
KLM
N
O
PQ
6
12
4X10(B10R)
5X10(R)
1.5X3
5X6
3X4
1.5X3
7X8
1.5X3 6X8
6X6
3X6
3X6
3X4
1.5X3
4X4(A2)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.95 18.99
BC 120 0.11 15.82
BC 120 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /765 /378 /235
I 1512 /- /- /896 /379 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 408 -622
B - C 1174 -2742
C - D 1181 -2412
D - E 1179 -2322
E - F 1178 -2317
Chords Tens. Comp.
F - G 961 -1891
G - H 932 -1911
H - I 1129 -2605
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2509 -826
Q - P 2506 -820
P - N 2055 -618
O - M 13 -6
Chords Tens. Comp.
M - L 2235 -871
L - K 2235 -871
K - I 2237 -869
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 197 0
C - P 399 -804
D - P 628 -292
D - N 413 -191
E - N 153 -202
N - O 5 0
Webs Tens. Comp.
N - M 2049 -659
N - F 1500 -481
M - F 287 -875
M - H 402 -719
H - K 293 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.330 C 999 360
VERT(CL): 0.617 C 723 240
HORZ(LL): 0.236 K - -
HORZ(TL): 0.443 K - -
Creep Factor: 2.0
Max TC CSI: 0.593
Max BC CSI: 0.638
Max Web CSI: 0.781
Wgt: 226.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A03
Truss Type
HIPS
Qty
1
Ply
1 2584
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
13'7"12 8'0"8 16'3"12
18'4"8 19'7"8 1'4"
1'4"
4"3
2'4"8'6"19'1"(a)
(a)
A
B
C
D E F
G H
I
J
KLM
N
O
PQ
6
12
4X10(B10R)
5X10(R)
1.5X3
5X6
3X4
1.5X3
7X8
1.5X3 6X8
6X6
3X6
3X6
3X4
1.5X3
4X4(A2)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 B4 2x4 SP M-30;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.65 19.69
BC 120 0.15 10.89
BC 104 10.90 19.58
BC 120 18.33 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1530 /- /- /870 /113 /285
K 1530 /- /- /908 /127 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.8
K Brg Width = 7.6 Min Req = 1.8
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 1135 -2725
C - D 1238 -2920
D - E 1256 -2895
E - F 1056 -2209
F - G 1052 -2017
Chords Tens. Comp.
G - H 1086 -2329
H - I 1020 -2206
I - J 1003 -2266
J - K 1166 -2672
K - L 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2366 -813
V - U 63 -22
T - S 2555 -808
S - Q 1912 -501
R - P 12 -5
Chords Tens. Comp.
Q - O 1900 -495
P - N 21 -9
N - M 21 -9
M - K 2321 -916
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 242 -476
C - T 255 0
V - T 2352 -807
T - U 76 0
T - E 617 -183
E - S 441 -891
F - S 528 -215
F - O 353 -135
Webs Tens. Comp.
R - Q 78 -14
O - P 37 -54
O - G 700 -275
O - H 202 -160
O - M 2097 -709
H - M 225 -444
M - J 300 -427
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.197 S 999 360
VERT(CL): 0.371 S 999 240
HORZ(LL): 0.099 M - -
HORZ(TL): 0.186 M - -
Creep Factor: 2.0
Max TC CSI: 0.548
Max BC CSI: 0.815
Max Web CSI: 0.896
Wgt: 235.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A04
Truss Type
COMN
Qty
1
Ply
1 4357
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
15'7"12 4'0"8 18'3"12
11'0"6 7'3"10 19'8"1'4"1'4"
1'4"
4"3
2'4"9'6"110'1"(a)
A
B
C D
E
F G
H
I
J
K
L
MN
O
P
Q
R
S
TUV
6
12
3X6(A1)
5X12
3X6
5X8
1.5X4
5X6
1.5X4
1.5X3
5X8
1.5X3
5X6
3X6 4X12
3X6
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 B4 2x4 SP M-30;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.65 19.69
BC 120 0.15 10.89
BC 104 10.90 19.58
BC 120 18.33 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1530 /- /- /870 /113 /285
K 1530 /- /- /908 /127 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.8
K Brg Width = 7.6 Min Req = 1.8
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 1135 -2725
C - D 1238 -2920
D - E 1256 -2895
E - F 1056 -2209
F - G 1052 -2017
Chords Tens. Comp.
G - H 1086 -2329
H - I 1020 -2206
I - J 1003 -2266
J - K 1166 -2672
K - L 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2366 -813
V - U 63 -22
T - S 2555 -808
S - Q 1912 -501
R - P 12 -5
Chords Tens. Comp.
Q - O 1900 -495
P - N 21 -9
N - M 21 -9
M - K 2321 -916
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 242 -476
C - T 255 0
V - T 2352 -807
T - U 76 0
T - E 617 -183
E - S 441 -891
F - S 528 -215
F - O 353 -135
Webs Tens. Comp.
R - Q 78 -14
O - P 37 -54
O - G 700 -275
O - H 202 -160
O - M 2097 -709
H - M 225 -444
M - J 300 -427
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.197 S 999 360
VERT(CL): 0.371 S 999 240
HORZ(LL): 0.099 M - -
HORZ(TL): 0.186 M - -
Creep Factor: 2.0
Max TC CSI: 0.548
Max BC CSI: 0.815
Max Web CSI: 0.896
Wgt: 235.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A04
Truss Type
COMN
Qty
1
Ply
1 4357
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
15'7"12 4'0"8 18'3"12
11'0"6 7'3"10 19'8"1'4"1'4"
1'4"
4"3
2'4"9'6"110'1"(a)
A
B
C D
E
F G
H
I
J
K
L
MN
O
P
Q
R
S
TUV
6
12
3X6(A1)
5X12
3X6
5X8
1.5X4
5X6
1.5X4
1.5X3
5X8
1.5X3
5X6
3X6 4X12
3X6
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP M-30 T3,T4 2x4 SP #2;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 18.52
BC 120 18.52 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1530 /- /- /871 /111 /313
I 1530 /- /- /908 /119 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.8
I Brg Width = 7.6 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 1048 -2619
C - D 1028 -2266
D - E 1062 -2254
E - F 915 -1931
Chords Tens. Comp.
F - G 1041 -2312
G - H 1025 -2385
H - I 1095 -2670
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - R 2246 -694
R - Q 2244 -695
Q - P 1568 -341
P - N 1569 -341
Chords Tens. Comp.
O - M 7 -3
M - L 7 -3
L - K 1881 -583
K - I 2312 -832
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
R - C 223 0
C - Q 382 -609
Q - E 637 -319
E - N 759 -275
N - O 95 0
N - L 1915 -592
Webs Tens. Comp.
N - F 272 -333
S - N 0 0
L - F 170 -397
F - K 418 -150
K - H 284 -373
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.155 N 999 360
VERT(CL): 0.292 N 999 240
HORZ(LL): 0.068 K - -
HORZ(TL): 0.128 K - -
Creep Factor: 2.0
Max TC CSI: 0.585
Max BC CSI: 0.896
Max Web CSI: 0.730
Wgt: 226.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A05
Truss Type
COMN
Qty
1
Ply
1 2599
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'8"20'4"
18'4"8 19'7"81'4"1'4"
1'4"
4"310'6"311'1"2(a)
A
B
CD
E
F
G
H
I
J
KLM
N
O
PQR
S
6
12
3X6(A1)
1.5X3
3X4
3X6
3X4 3X6
5X6
5X8
2X4 3X6 4X8
3X8
3X4
3X6
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP M-30 T3,T4 2x4 SP #2;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 18.52
BC 120 18.52 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1530 /- /- /871 /111 /313
I 1530 /- /- /908 /119 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.8
I Brg Width = 7.6 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 1048 -2619
C - D 1028 -2266
D - E 1062 -2254
E - F 915 -1931
Chords Tens. Comp.
F - G 1041 -2312
G - H 1025 -2385
H - I 1095 -2670
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - R 2246 -694
R - Q 2244 -695
Q - P 1568 -341
P - N 1569 -341
Chords Tens. Comp.
O - M 7 -3
M - L 7 -3
L - K 1881 -583
K - I 2312 -832
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
R - C 223 0
C - Q 382 -609
Q - E 637 -319
E - N 759 -275
N - O 95 0
N - L 1915 -592
Webs Tens. Comp.
N - F 272 -333
S - N 0 0
L - F 170 -397
F - K 418 -150
K - H 284 -373
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.155 N 999 360
VERT(CL): 0.292 N 999 240
HORZ(LL): 0.068 K - -
HORZ(TL): 0.128 K - -
Creep Factor: 2.0
Max TC CSI: 0.585
Max BC CSI: 0.896
Max Web CSI: 0.730
Wgt: 226.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A05
Truss Type
COMN
Qty
1
Ply
1 2599
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'8"20'4"
18'4"8 19'7"81'4"1'4"
1'4"
4"310'6"311'1"2(a)
A
B
CD
E
F
G
H
I
J
KLM
N
O
PQR
S
6
12
3X6(A1)
1.5X3
3X4
3X6
3X4 3X6
5X6
5X8
2X4 3X6 4X8
3X8
3X4
3X6
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x8 SP 2400f-1.8E;
T2 2x6 SP #2;
Bot chord 2x4 SP #2 B1,B2 2x6 SP #2;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Tray Scab(s)
(2) 2x8x9-3-5 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer face
of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nail clusters at: BRG.:
(4), heel: (6), 1st panel point: (2).
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.28 15.84
BC 26 13.63 15.83
BC 100 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /810 /345 /290
J 1512 /- /- /899 /371 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
J Brg Width = 7.6 Min Req = 1.8
Bearings A & J are a rigid surface.
Bearings A & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 364 -622
B - C 1306 -3262
C - D 1173 -2813
D - E 884 -2005
E - F 990 -2002
Chords Tens. Comp.
F - G 930 -2163
G - H 924 -1963
H - I 922 -2135
I - J 1052 -2663
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 3166 -1078
V - U 3156 -1075
U - T 3156 -1075
T - R 2501 -787
S - P 32 -13
Chords Tens. Comp.
R - O 2470 -773
Q - N 32 -11
N - M 2302 -827
M - L 2302 -827
L - J 2304 -827
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
V - C 76 -162
C - T 336 -764
D - T 442 -135
D - O 449 -900
S - R 43 -5
E - O 1361 -677
O - P 113 0
Webs Tens. Comp.
O - F 181 -108
O - G 201 -149
O - N 1969 -632
P - Q 83 0
G - N 128 -441
N - I 271 -536
I - L 217 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.212 O 999 360
VERT(CL): 0.397 O 999 240
HORZ(LL): 0.136 L - -
HORZ(TL): 0.255 L - -
Creep Factor: 2.0
Max TC CSI: 0.468
Max BC CSI: 0.996
Max Web CSI: 0.750
Wgt: 311.5 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A06
Truss Type
COMN
Qty
12
Ply
1 2683
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'8"20'4"
13'7"10 2'0"8 19'7"82'8"6 1'4"
1'4"
4"3
2'4"10'6"311'1"2(a)
A
B
C
D
E
F
G H
I
J
K
LMN
OP
Q
RSTUV
6
12
4X12(B10R)
3X4
5X6
5X10(R)
3X4(**)
5X6(R)
10X10
3X3
2X4
3X4
4X10
3X6
3X6
3X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x8 SP 2400f-1.8E;
T2 2x6 SP #2;
Bot chord 2x4 SP #2 B1,B2 2x6 SP #2;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Tray Scab(s)
(2) 2x8x9-3-5 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer face
of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nail clusters at: BRG.:
(4), heel: (6), 1st panel point: (2).
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.28 15.84
BC 26 13.63 15.83
BC 100 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /810 /345 /290
J 1512 /- /- /899 /371 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
J Brg Width = 7.6 Min Req = 1.8
Bearings A & J are a rigid surface.
Bearings A & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 364 -622
B - C 1306 -3262
C - D 1173 -2813
D - E 884 -2005
E - F 990 -2002
Chords Tens. Comp.
F - G 930 -2163
G - H 924 -1963
H - I 922 -2135
I - J 1052 -2663
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 3166 -1078
V - U 3156 -1075
U - T 3156 -1075
T - R 2501 -787
S - P 32 -13
Chords Tens. Comp.
R - O 2470 -773
Q - N 32 -11
N - M 2302 -827
M - L 2302 -827
L - J 2304 -827
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
V - C 76 -162
C - T 336 -764
D - T 442 -135
D - O 449 -900
S - R 43 -5
E - O 1361 -677
O - P 113 0
Webs Tens. Comp.
O - F 181 -108
O - G 201 -149
O - N 1969 -632
P - Q 83 0
G - N 128 -441
N - I 271 -536
I - L 217 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.212 O 999 360
VERT(CL): 0.397 O 999 240
HORZ(LL): 0.136 L - -
HORZ(TL): 0.255 L - -
Creep Factor: 2.0
Max TC CSI: 0.468
Max BC CSI: 0.996
Max Web CSI: 0.750
Wgt: 311.5 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A06
Truss Type
COMN
Qty
12
Ply
1 2683
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
17'8"20'4"
13'7"10 2'0"8 19'7"82'8"6 1'4"
1'4"
4"3
2'4"10'6"311'1"2(a)
A
B
C
D
E
F
G H
I
J
K
LMN
OP
Q
RSTUV
6
12
4X12(B10R)
3X4
5X6
5X10(R)
3X4(**)
5X6(R)
10X10
3X3
2X4
3X4
4X10
3X6
3X6
3X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E; T2 2x6 SP #2;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3 W3,W5 2x4 SP M-30;
W6 2x4 SP 2400f-2.0E;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.63 16.30
BC 120 0.11 16.19
BC 30 13.63 16.18
BC 120 15.68 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /770 /126 /272
I 1512 /- /- /900 /126 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 400 -622
B - C 1162 -2797
C - D 1043 -2178
D - E 970 -1843
E - F 1005 -2141
Chords Tens. Comp.
F - G 985 -2073
G - H 967 -2139
H - I 1094 -2661
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2573 -820
V - T 2570 -814
U - Q 108 -37
T - S 1840 -468
S - N 1760 -430
R - P 33 -6
Chords Tens. Comp.
Q - O 75 -31
P - M 75 -24
M - L 2300 -855
L - K 2300 -855
K - I 2302 -854
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 195 -6
C - T 479 -938
D - T 628 -285
U - S 92 -19
R - Q 297 -136
N - O 79 -66
N - E 834 -314
Webs Tens. Comp.
N - F 244 -218
N - M 1944 -641
O - P 173 -290
F - M 172 -424
M - H 290 -535
H - K 218 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.319 N 999 360
VERT(CL): 0.598 N 746 240
HORZ(LL): 0.234 K - -
HORZ(TL): 0.438 K - -
Creep Factor: 2.0
Max TC CSI: 0.593
Max BC CSI: 0.386
Max Web CSI: 0.914
Wgt: 231.7 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A07
Truss Type
HIPS
Qty
1
Ply
1 2611
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
16'4"2'8"19'
16'4"2'0"8 19'7"8 1'4"
1'4"
4"3
2'4"9'10"310'5"2(a)
A
B
C
D E
F
G
H
I
J
KLM
NO
P
Q
R
STUV
6
12
4X10(B10R)
5X10(R)
5X6
5X6(R)
3X4 2X4
3X6
5X8
3X3
5X6
3X4
4X10 3X6
3X6
3X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E; T2 2x6 SP #2;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3 W3,W5 2x4 SP M-30;
W6 2x4 SP 2400f-2.0E;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.63 16.30
BC 120 0.11 16.19
BC 30 13.63 16.18
BC 120 15.68 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /770 /126 /272
I 1512 /- /- /900 /126 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 400 -622
B - C 1162 -2797
C - D 1043 -2178
D - E 970 -1843
E - F 1005 -2141
Chords Tens. Comp.
F - G 985 -2073
G - H 967 -2139
H - I 1094 -2661
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - V 2573 -820
V - T 2570 -814
U - Q 108 -37
T - S 1840 -468
S - N 1760 -430
R - P 33 -6
Chords Tens. Comp.
Q - O 75 -31
P - M 75 -24
M - L 2300 -855
L - K 2300 -855
K - I 2302 -854
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - V 195 -6
C - T 479 -938
D - T 628 -285
U - S 92 -19
R - Q 297 -136
N - O 79 -66
N - E 834 -314
Webs Tens. Comp.
N - F 244 -218
N - M 1944 -641
O - P 173 -290
F - M 172 -424
M - H 290 -535
H - K 218 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.319 N 999 360
VERT(CL): 0.598 N 746 240
HORZ(LL): 0.234 K - -
HORZ(TL): 0.438 K - -
Creep Factor: 2.0
Max TC CSI: 0.593
Max BC CSI: 0.386
Max Web CSI: 0.914
Wgt: 231.7 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A07
Truss Type
HIPS
Qty
1
Ply
1 2611
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
16'4"2'8"19'
16'4"2'0"8 19'7"8 1'4"
1'4"
4"3
2'4"9'10"310'5"2(a)
A
B
C
D E
F
G
H
I
J
KLM
NO
P
Q
R
STUV
6
12
4X10(B10R)
5X10(R)
5X6
5X6(R)
3X4 2X4
3X6
5X8
3X3
5X6
3X4
4X10 3X6
3X6
3X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E; T2 2x6 SP #2;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3 W5 2x4 SP M-30;
W6 2x4 SP 2400f-2.0E;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.63 18.30
BC 120 0.11 15.82
BC 26 13.63 15.82
BC 120 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /748 /441 /260
I 1512 /- /- /884 /443 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 406 -622
B - C 1204 -2817
C - D 1158 -2361
D - E 1120 -2183
E - F 1116 -2174
Chords Tens. Comp.
F - G 937 -1833
G - H 908 -1863
H - I 1113 -2591
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - T 2594 -859
T - S 2592 -854
S - Q 1983 -578
R - O 39 -16
Q - N 1948 -562
Chords Tens. Comp.
P - M 49 -19
M - L 2219 -853
L - K 2219 -853
K - I 2221 -851
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - T 222 0
C - S 451 -941
D - S 628 -292
D - N 455 -150
R - Q 47 0
E - N 85 -107
O - P 0 -28
Webs Tens. Comp.
N - O 12 -22
N - M 2200 -680
N - F 1671 -491
M - F 362 -1161
M - H 419 -762
H - K 306 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.331 T 999 360
VERT(CL): 0.620 T 720 240
HORZ(LL): 0.242 K - -
HORZ(TL): 0.454 K - -
Creep Factor: 2.0
Max TC CSI: 0.594
Max BC CSI: 0.872
Max Web CSI: 0.838
Wgt: 235.9 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A08
Truss Type
HIPS
Qty
1
Ply
1 2621
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
14'4"6'8"17'
16'4"2'0"8 19'7"8 1'4"
1'4"
4"3
2'4"8'10"39'5"2(a)
(a)
A
B
C
D E F
G
H
I
J
KLM
N O
P
QRST
6
12
5X8(B10R)
5X10(R)
6X6
3X4
8X8
3X3
2X4 6X8
5X8
3X6
3X6
3X4
4X4(A2)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
T1 2x8 SP 2400f-1.8E; T2 2x6 SP #2;
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3 W5 2x4 SP M-30;
W6 2x4 SP 2400f-2.0E;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.63 18.30
BC 120 0.11 15.82
BC 26 13.63 15.82
BC 120 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /748 /441 /260
I 1512 /- /- /884 /443 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.5
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 406 -622
B - C 1204 -2817
C - D 1158 -2361
D - E 1120 -2183
E - F 1116 -2174
Chords Tens. Comp.
F - G 937 -1833
G - H 908 -1863
H - I 1113 -2591
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - T 2594 -859
T - S 2592 -854
S - Q 1983 -578
R - O 39 -16
Q - N 1948 -562
Chords Tens. Comp.
P - M 49 -19
M - L 2219 -853
L - K 2219 -853
K - I 2221 -851
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - T 222 0
C - S 451 -941
D - S 628 -292
D - N 455 -150
R - Q 47 0
E - N 85 -107
O - P 0 -28
Webs Tens. Comp.
N - O 12 -22
N - M 2200 -680
N - F 1671 -491
M - F 362 -1161
M - H 419 -762
H - K 306 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.331 T 999 360
VERT(CL): 0.620 T 720 240
HORZ(LL): 0.242 K - -
HORZ(TL): 0.454 K - -
Creep Factor: 2.0
Max TC CSI: 0.594
Max BC CSI: 0.872
Max Web CSI: 0.838
Wgt: 235.9 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A08
Truss Type
HIPS
Qty
1
Ply
1 2621
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
14'4"6'8"17'
16'4"2'0"8 19'7"8 1'4"
1'4"
4"3
2'4"8'10"39'5"2(a)
(a)
A
B
C
D E F
G
H
I
J
KLM
N O
P
QRST
6
12
5X8(B10R)
5X10(R)
6X6
3X4
8X8
3X3
2X4 6X8
5X8
3X6
3X6
3X4
4X4(A2)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x8 SP 2400f-1.8E;
Bot chord 2x4 SP #2 B1 2x4 SP M-30;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Tray Scab(s)
(2) 2x8x9-10-10 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer
face of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nail clusters at:
BRG.: (4), heel: (5), 1st panel point: (2).
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.68 20.34
BC 120 0.16 15.82
BC 26 13.68 15.82
BC 120 15.82 35.20
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1432 /- /- /760 /132 /217
I 1512 /- /- /892 /175 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.8
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 411 -623
B - C 1383 -3142
C - D 1204 -2561
D - E 1312 -2636
E - F 1308 -2629
Chords Tens. Comp.
F - G 1004 -1960
G - H 981 -2005
H - I 1156 -2630
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - S 2993 -1096
S - R 2987 -1093
R - P 2233 -719
Q - N 50 -26
Chords Tens. Comp.
P - M 2185 -691
O - L 46 -22
L - K 2264 -903
K - I 2266 -902
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
S - C 102 -89
C - R 452 -856
D - R 432 -137
D - M 626 -233
Q - P 46 -1
E - M 213 -287
N - O 47 0
Webs Tens. Comp.
M - N 70 0
M - L 1895 -639
M - F 1408 -496
L - F 199 -550
L - H 370 -653
H - K 262 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.238 E 999 360
VERT(CL): 0.446 E 999 240
HORZ(LL): 0.147 K - -
HORZ(TL): 0.275 K - -
Creep Factor: 2.0
Max TC CSI: 0.675
Max BC CSI: 0.742
Max Web CSI: 0.722
Wgt: 278.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A09
Truss Type
HIPS
Qty
1
Ply
1 2643
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
12'4"10'8"15'
13'8"2 2'19'8"2'7"14 1'4"
1'4"
4"3
2'4"7'10"38'5"2(a)A
B
C
D E F
G
H
I
J
KL
MN
O
PQRS
6
12
5X8(B10R)
3X4
7X6
3X4
7X8
3X3
4X10
6X6
3X6
3X4
5X6
4X4(A2)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x8 SP 2400f-1.8E;
Bot chord 2x4 SP #2 B1 2x4 SP M-30;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
Tray Scab(s)
(2) 2x8x9-10-10 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer
face of chord with: 0.131"x3", min. nails @ 8" oc, Plus additional nail clusters at:
BRG.: (4), heel: (5), 1st panel point: (2).
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.68 20.34
BC 120 0.16 15.82
BC 26 13.68 15.82
BC 120 15.82 35.20
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1432 /- /- /760 /132 /217
I 1512 /- /- /892 /175 /-
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
I Brg Width = 7.6 Min Req = 1.8
Bearings A & I are a rigid surface.
Bearings A & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 411 -623
B - C 1383 -3142
C - D 1204 -2561
D - E 1312 -2636
E - F 1308 -2629
Chords Tens. Comp.
F - G 1004 -1960
G - H 981 -2005
H - I 1156 -2630
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - S 2993 -1096
S - R 2987 -1093
R - P 2233 -719
Q - N 50 -26
Chords Tens. Comp.
P - M 2185 -691
O - L 46 -22
L - K 2264 -903
K - I 2266 -902
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
S - C 102 -89
C - R 452 -856
D - R 432 -137
D - M 626 -233
Q - P 46 -1
E - M 213 -287
N - O 47 0
Webs Tens. Comp.
M - N 70 0
M - L 1895 -639
M - F 1408 -496
L - F 199 -550
L - H 370 -653
H - K 262 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.238 E 999 360
VERT(CL): 0.446 E 999 240
HORZ(LL): 0.147 K - -
HORZ(TL): 0.275 K - -
Creep Factor: 2.0
Max TC CSI: 0.675
Max BC CSI: 0.742
Max Web CSI: 0.722
Wgt: 278.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A09
Truss Type
HIPS
Qty
1
Ply
1 2643
08/24/2020
38'
SEAT PLATE REQ.SEAT PLATE REQ.
12'4"10'8"15'
13'8"2 2'19'8"2'7"14 1'4"
1'4"
4"3
2'4"7'10"38'5"2(a)A
B
C
D E F
G
H
I
J
KL
MN
O
PQRS
6
12
5X8(B10R)
3X4
7X6
3X4
7X8
3X3
4X10
6X6
3X6
3X4
5X6
4X4(A2)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.33 25.00
BC 120 0.15 18.52
BC 75 18.52 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 699 /- /- /447 /170 /203
O 1695 /- /- /787 /414 /-
I 740 /- /- /512 /181 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
O Brg Width = 3.5 Min Req = 2.0
I Brg Width = 7.6 Min Req = 1.5
Bearings B, O, & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 415 -924
C - D 301 -603
D - E 416 -64
E - F 416 -63
Chords Tens. Comp.
F - G 244 -386
G - H 229 -459
H - I 403 -1006
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 772 -207
Q - P 487 -118
P - N 488 -118
O - M 3 -5
Chords Tens. Comp.
M - L 825 -262
L - K 825 -262
K - I 828 -262
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 236 -333
D - Q 430 -114
D - N 451 -970
E - N 278 -505
N - O 760 -1657
Webs Tens. Comp.
N - M 348 0
N - F 445 -859
M - F 381 -154
M - H 318 -575
H - K 229 -7
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.026 K 999 360
VERT(CL): 0.052 K 999 240
HORZ(LL): 0.014 K - -
HORZ(TL): 0.026 K - -
Creep Factor: 2.0
Max TC CSI: 0.955
Max BC CSI: 0.814
Max Web CSI: 0.572
Wgt: 205.8 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A10
Truss Type
HIPS
Qty
1
Ply
1 2511
08/24/2020
18'5"12 19'6"4
SEAT PLATE REQ.SEAT PLATE REQ.
10'4"14'8"13'
18'4"8 19'7"81'4"1'4"
38'
1'4"
4"36'10"37'5"2(a)(a)
A
B
C
D E F
G
H
I
J
KLM
N
O
PQ
6
12
3X6(A1)
1.5X4
5X8
3X4 3X6
1.5X4
5X6
3X6 3X8
6X6
3X6
3X6
3X4
1.5X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.33 25.00
BC 120 0.15 18.52
BC 75 18.52 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 699 /- /- /447 /170 /203
O 1695 /- /- /787 /414 /-
I 740 /- /- /512 /181 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
O Brg Width = 3.5 Min Req = 2.0
I Brg Width = 7.6 Min Req = 1.5
Bearings B, O, & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 415 -924
C - D 301 -603
D - E 416 -64
E - F 416 -63
Chords Tens. Comp.
F - G 244 -386
G - H 229 -459
H - I 403 -1006
I - J 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 772 -207
Q - P 487 -118
P - N 488 -118
O - M 3 -5
Chords Tens. Comp.
M - L 825 -262
L - K 825 -262
K - I 828 -262
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 236 -333
D - Q 430 -114
D - N 451 -970
E - N 278 -505
N - O 760 -1657
Webs Tens. Comp.
N - M 348 0
N - F 445 -859
M - F 381 -154
M - H 318 -575
H - K 229 -7
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.026 K 999 360
VERT(CL): 0.052 K 999 240
HORZ(LL): 0.014 K - -
HORZ(TL): 0.026 K - -
Creep Factor: 2.0
Max TC CSI: 0.955
Max BC CSI: 0.814
Max Web CSI: 0.572
Wgt: 205.8 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A10
Truss Type
HIPS
Qty
1
Ply
1 2511
08/24/2020
18'5"12 19'6"4
SEAT PLATE REQ.SEAT PLATE REQ.
10'4"14'8"13'
18'4"8 19'7"81'4"1'4"
38'
1'4"
4"36'10"37'5"2(a)(a)
A
B
C
D E F
G
H
I
J
KLM
N
O
PQ
6
12
3X6(A1)
1.5X4
5X8
3X4 3X6
1.5X4
5X6
3X6 3X8
6X6
3X6
3X6
3X4
1.5X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x4 SP 2400f-2.0E;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 8.27 26.94
BC 75 0.00 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
R 473 /- /- /428 /159 /186
P 1737 /- /- /971 /395 /-
J 944 /- /- /602 /234 /-
Wind reactions based on MWFRS
R Brg Width = 6.9 Min Req = 1.5
P Brg Width = 7.6 Min Req = 2.0
J Brg Width = 7.6 Min Req = 1.5
Bearings R, P, & J are a rigid surface.
Bearings R, P, & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
B - C 262 -491
C - D 206 -197
D - E 174 -117
E - F 488 -200
Chords Tens. Comp.
F - G 488 -200
G - H 396 -602
H - I 507 -1080
I - J 637 -1440
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
R - Q 636 -706
Q - P 636 -706
P - O 370 -218
O - N 370 -218
Chords Tens. Comp.
N - M 900 -180
M - L 900 -180
L - J 1231 -449
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - R 363 -405
B - S 379 -146
R - S 694 -437
C - T 289 -307
S - Q 344 -484
S - T 521 -432
S - P 1090 -781
D - T 164 -262
T - E 608 -476
Webs Tens. Comp.
T - U 335 -267
E - U 589 -784
P - U 951 -1567
U - G 620 -1215
U - N 822 -365
G - N 267 -3
N - H 247 -407
H - L 422 -67
L - I 306 -375
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.79 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.042 L 999 360
VERT(CL): 0.080 L 999 240
HORZ(LL): 0.012 L - -
HORZ(TL): 0.022 L - -
Creep Factor: 2.0
Max TC CSI: 0.805
Max BC CSI: 0.493
Max Web CSI: 0.924
Wgt: 250.6 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A11
Truss Type
HIPS
Qty
1
Ply
1 2470
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
8'3"4 18'8"11'
37'11"41'4"12 1'4"
1'8"9
4"3
1'4"5'10"36'5"2(a)
(a)
A
B
C
D E F G H
I
J
K
LMNOPQR
S T
U
6
12
3X6(R)
2X4
3X8
2X4
5X6
3X8
4X4
5X8
3X6
3X6
3X8 3X6
5X6
2X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x4 SP 2400f-2.0E;
Bot chord 2x4 SP #2 B4 2x4 SP 2400f-2.0E;
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 8.27 26.94
BC 75 0.00 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
R 473 /- /- /428 /159 /186
P 1737 /- /- /971 /395 /-
J 944 /- /- /602 /234 /-
Wind reactions based on MWFRS
R Brg Width = 6.9 Min Req = 1.5
P Brg Width = 7.6 Min Req = 2.0
J Brg Width = 7.6 Min Req = 1.5
Bearings R, P, & J are a rigid surface.
Bearings R, P, & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
B - C 262 -491
C - D 206 -197
D - E 174 -117
E - F 488 -200
Chords Tens. Comp.
F - G 488 -200
G - H 396 -602
H - I 507 -1080
I - J 637 -1440
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
R - Q 636 -706
Q - P 636 -706
P - O 370 -218
O - N 370 -218
Chords Tens. Comp.
N - M 900 -180
M - L 900 -180
L - J 1231 -449
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - R 363 -405
B - S 379 -146
R - S 694 -437
C - T 289 -307
S - Q 344 -484
S - T 521 -432
S - P 1090 -781
D - T 164 -262
T - E 608 -476
Webs Tens. Comp.
T - U 335 -267
E - U 589 -784
P - U 951 -1567
U - G 620 -1215
U - N 822 -365
G - N 267 -3
N - H 247 -407
H - L 422 -67
L - I 306 -375
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.79 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.042 L 999 360
VERT(CL): 0.080 L 999 240
HORZ(LL): 0.012 L - -
HORZ(TL): 0.022 L - -
Creep Factor: 2.0
Max TC CSI: 0.805
Max BC CSI: 0.493
Max Web CSI: 0.924
Wgt: 250.6 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A11
Truss Type
HIPS
Qty
1
Ply
1 2470
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
8'3"4 18'8"11'
37'11"41'4"12 1'4"
1'8"9
4"3
1'4"5'10"36'5"2(a)
(a)
A
B
C
D E F G H
I
J
K
LMNOPQR
S T
U
6
12
3X6(R)
2X4
3X8
2X4
5X6
3X8
4X4
5X8
3X6
3X6
3X8 3X6
5X6
2X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 6.27 28.94
BC 75 0.00 15.57
BC 75 13.29 30.31
BC 93 30.02 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
Z 463 /- /- /426 /206 /149
X 1835 /- /- /982 /406 /-
K 894 /- /- /559 /230 /-
Wind reactions based on MWFRS
Z Brg Width = 6.9 Min Req = 1.5
X Brg Width = 7.6 Min Req = 2.2
K Brg Width = 7.6 Min Req = 1.5
Bearings Z, X, & K are a rigid surface.
Bearings Z, X, & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
B - C 588 -352
C - D 869 -297
D - E 281 -392
E - F 281 -392
F - G 281 -392
Chords Tens. Comp.
G - H 583 -1095
H - I 850 -1611
I - J 765 -1641
J - K 659 -1444
K - L 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
Z - Y 173 -135
Y - X 42 -83
W - U 504 -818
X - V 9 -18
U - S 507 -835
V - T 0 0
Chords Tens. Comp.
S - R 1083 -342
R - Q 1083 -342
Q - N 1198 -417
P - O 0 0
O - M 38 -18
M - K 1249 -524
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - Z 580 -425
B - Y 226 -345
C - Y 229 -360
C - W 799 -1049
Y - W 369 -380
W - X 945 -1733
W - D 584 -1240
D - S 1493 -644
U - V 90 -42
S - G 416 -860
Webs Tens. Comp.
E - S 155 -315
G - Q 241 -48
Q - H 87 -128
H - N 620 -347
N - O 75 -5
N - I 171 -165
N - M 1245 -519
N - J 182 -58
M - J 161 -320
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.79 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.071 P 999 360
VERT(CL): 0.134 P 999 240
HORZ(LL): 0.023 M - -
HORZ(TL): 0.044 M - -
Creep Factor: 2.0
Max TC CSI: 0.793
Max BC CSI: 0.804
Max Web CSI: 0.655
Wgt: 231.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A12
Truss Type
HIPS
Qty
1
Ply
1 2513
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
6'3"4 22'8"9'
15'5"6 1"8 14'5"6 1"8 7'9"81'4"12 1'4"
37'11"4
1'8"9
4"3
1'4'10"35'5"2(a)
A
B
C D E F G H
I
J
K
L
M
NOPQRS
TU VW XYZ
6
12
3X6
5X8
3X8
6X6
4X4
1.5X4
1.5X4
1.5X4
4X8 3X6
3X6 5X6
5X6
1.5X4
1.5X4
4X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 6.27 28.94
BC 75 0.00 15.57
BC 75 13.29 30.31
BC 93 30.02 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
Z 463 /- /- /426 /206 /149
X 1835 /- /- /982 /406 /-
K 894 /- /- /559 /230 /-
Wind reactions based on MWFRS
Z Brg Width = 6.9 Min Req = 1.5
X Brg Width = 7.6 Min Req = 2.2
K Brg Width = 7.6 Min Req = 1.5
Bearings Z, X, & K are a rigid surface.
Bearings Z, X, & K require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
B - C 588 -352
C - D 869 -297
D - E 281 -392
E - F 281 -392
F - G 281 -392
Chords Tens. Comp.
G - H 583 -1095
H - I 850 -1611
I - J 765 -1641
J - K 659 -1444
K - L 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
Z - Y 173 -135
Y - X 42 -83
W - U 504 -818
X - V 9 -18
U - S 507 -835
V - T 0 0
Chords Tens. Comp.
S - R 1083 -342
R - Q 1083 -342
Q - N 1198 -417
P - O 0 0
O - M 38 -18
M - K 1249 -524
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - Z 580 -425
B - Y 226 -345
C - Y 229 -360
C - W 799 -1049
Y - W 369 -380
W - X 945 -1733
W - D 584 -1240
D - S 1493 -644
U - V 90 -42
S - G 416 -860
Webs Tens. Comp.
E - S 155 -315
G - Q 241 -48
Q - H 87 -128
H - N 620 -347
N - O 75 -5
N - I 171 -165
N - M 1245 -519
N - J 182 -58
M - J 161 -320
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.79 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.071 P 999 360
VERT(CL): 0.134 P 999 240
HORZ(LL): 0.023 M - -
HORZ(TL): 0.044 M - -
Creep Factor: 2.0
Max TC CSI: 0.793
Max BC CSI: 0.804
Max Web CSI: 0.655
Wgt: 231.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
A12
Truss Type
HIPS
Qty
1
Ply
1 2513
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
6'3"4 22'8"9'
15'5"6 1"8 14'5"6 1"8 7'9"81'4"12 1'4"
37'11"4
1'8"9
4"3
1'4'10"35'5"2(a)
A
B
C D E F G H
I
J
K
L
M
NOPQRS
TU VW XYZ
6
12
3X6
5X8
3X8
6X6
4X4
1.5X4
1.5X4
1.5X4
4X8 3X6
3X6 5X6
5X6
1.5X4
1.5X4
4X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T2,T3 2x4 SP M-30;
Bot chord 2x4 SP M-30 B1 2x4 SP #2;
B3 2x4 SP 2400f-2.0E;
Webs 2x4 SP #3 W7,W12 2x4 SP #2;
W8 2x4 SP M-30;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.40 to 62 plf at 4.27
TC: From 31 plf at 4.27 to 31 plf at 30.94
TC: From 62 plf at 30.94 to 62 plf at 39.27
BC: From 14 plf at 0.00 to 14 plf at 4.30
BC: From 7 plf at 4.30 to 7 plf at 30.65
BC: From 14 plf at 30.65 to 14 plf at 37.94
TC: 280 lb Conc. Load at 4.30
TC: 187 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
TC: 190 lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
TC: 303 lb Conc. Load at 30.91
BC: 213 lb Conc. Load at 4.30
BC: 111 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
BC: 98 lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
BC: 392 lb Conc. Load at 30.91
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 4.27 30.94
BC 75 0.00 15.57
BC 45 13.30 30.84
BC 87 30.02 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
AC 591 /- /- /- /195 /-
Z 4719 /- /- /- /1619 /-
L 1792 /- /- /- /588 /-
Wind reactions based on MWFRS
AC Brg Width = 6.9 Min Req = 1.5
Z Brg Width = 7.6 Min Req = 5.6
L Brg Width = 7.6 Min Req = 2.1
Bearings AC, Z, & L are a rigid surface.
Bearings AC, Z, & L require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 -15
B - C 197 -557
C - D 583 -93
D - E 3227 -1048
E - F 236 -932
F - G 236 -932
Chords Tens. Comp.
G - H 236 -932
H - I 996 -3323
I - J 1345 -4263
J - K 1522 -4473
K - L 1089 -3294
L - M 35 -14
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
AC-AB 6 0
AB-AA 450 -157
AA- Z 98 -301
Z - W 16 -63
Y - X 999 -3071
X - V 1014 -3133
V - U 3226 -970
Chords Tens. Comp.
U - T 3226 -970
T - S 4263 -1348
S - Q 4063 -1375
R - P 48 -15
Q - O 4008 -1358
P - N 134 -48
N - L 2883 -950
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B -AC 212 -575
B -AB 469 -165
C -AB 268 -20
C -AA 316 -1050
AA- D 958 -296
AA- Y 7 -336
D - Y 1079 -3118
Y - Z 1534 -4360
Y - E 1063 -3020
E - V 4722 -1459
X - W 36 -50
F - V 285 -648
Webs Tens. Comp.
V - H 856 -2692
H - T 854 -229
T - I 415 -1115
I - S 62 -60
S - J 357 0
R - Q 231 -102
O - P 183 0
O - J 1245 -316
O - N 2857 -936
O - K 1197 -415
N - K 318 -847
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.79 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.219 S 999 360
VERT(CL): 0.408 S 721 240
HORZ(LL): 0.059 N - -
HORZ(TL): 0.109 N - -
Creep Factor: 2.0
Max TC CSI: 0.914
Max BC CSI: 0.997
Max Web CSI: 0.685
Wgt: 233.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A13
Truss Type
HIPS
Qty
1
Ply
1 2692
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
4'3"4 26'8"7'
15'6"14 14'5"6 7'11"1'4"12 1'4"
37'11"4
1'8"9
4"3
1'3'10"34'5"2(a)
(a)
(a)
A
B
C D E F G H I J
K
L
M
N
OPQRSTUV
WXYZAAABAC
6
12
3X6
5X6
3X8
3X10
7X8
5X6
6X8
1.5X3
1.5X3
1.5X3
6X12
3X6
H0308
4X6
3X6
1.5X3
H0710
1.5X3
5X8
6X6
4X6(A2)
4'3"10
213#
280#
2'0"6
111#
187#
2'
111#
187#
2'
111#
187#
2'
111#
187#
2'
111#
187#
2'
98#
190#
1'3"4
98#
190#
1'3"4
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'0"6
392#
303#
7'0"6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T2,T3 2x4 SP M-30;
Bot chord 2x4 SP M-30 B1 2x4 SP #2;
B3 2x4 SP 2400f-2.0E;
Webs 2x4 SP #3 W7,W12 2x4 SP #2;
W8 2x4 SP M-30;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.40 to 62 plf at 4.27
TC: From 31 plf at 4.27 to 31 plf at 30.94
TC: From 62 plf at 30.94 to 62 plf at 39.27
BC: From 14 plf at 0.00 to 14 plf at 4.30
BC: From 7 plf at 4.30 to 7 plf at 30.65
BC: From 14 plf at 30.65 to 14 plf at 37.94
TC: 280 lb Conc. Load at 4.30
TC: 187 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
TC: 190 lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
TC: 303 lb Conc. Load at 30.91
BC: 213 lb Conc. Load at 4.30
BC: 111 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
BC: 98 lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
BC: 392 lb Conc. Load at 30.91
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 4.27 30.94
BC 75 0.00 15.57
BC 45 13.30 30.84
BC 87 30.02 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
AC 591 /- /- /- /195 /-
Z 4719 /- /- /- /1619 /-
L 1792 /- /- /- /588 /-
Wind reactions based on MWFRS
AC Brg Width = 6.9 Min Req = 1.5
Z Brg Width = 7.6 Min Req = 5.6
L Brg Width = 7.6 Min Req = 2.1
Bearings AC, Z, & L are a rigid surface.
Bearings AC, Z, & L require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 -15
B - C 197 -557
C - D 583 -93
D - E 3227 -1048
E - F 236 -932
F - G 236 -932
Chords Tens. Comp.
G - H 236 -932
H - I 996 -3323
I - J 1345 -4263
J - K 1522 -4473
K - L 1089 -3294
L - M 35 -14
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
AC-AB 6 0
AB-AA 450 -157
AA- Z 98 -301
Z - W 16 -63
Y - X 999 -3071
X - V 1014 -3133
V - U 3226 -970
Chords Tens. Comp.
U - T 3226 -970
T - S 4263 -1348
S - Q 4063 -1375
R - P 48 -15
Q - O 4008 -1358
P - N 134 -48
N - L 2883 -950
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B -AC 212 -575
B -AB 469 -165
C -AB 268 -20
C -AA 316 -1050
AA- D 958 -296
AA- Y 7 -336
D - Y 1079 -3118
Y - Z 1534 -4360
Y - E 1063 -3020
E - V 4722 -1459
X - W 36 -50
F - V 285 -648
Webs Tens. Comp.
V - H 856 -2692
H - T 854 -229
T - I 415 -1115
I - S 62 -60
S - J 357 0
R - Q 231 -102
O - P 183 0
O - J 1245 -316
O - N 2857 -936
O - K 1197 -415
N - K 318 -847
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.79 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.219 S 999 360
VERT(CL): 0.408 S 721 240
HORZ(LL): 0.059 N - -
HORZ(TL): 0.109 N - -
Creep Factor: 2.0
Max TC CSI: 0.914
Max BC CSI: 0.997
Max Web CSI: 0.685
Wgt: 233.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A13
Truss Type
HIPS
Qty
1
Ply
1 2692
08/24/2020
13'3"1 24'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
4'3"4 26'8"7'
15'6"14 14'5"6 7'11"1'4"12 1'4"
37'11"4
1'8"9
4"3
1'3'10"34'5"2(a)
(a)
(a)
A
B
C D E F G H I J
K
L
M
N
OPQRSTUV
WXYZAAABAC
6
12
3X6
5X6
3X8
3X10
7X8
5X6
6X8
1.5X3
1.5X3
1.5X3
6X12
3X6
H0308
4X6
3X6
1.5X3
H0710
1.5X3
5X8
6X6
4X6(A2)
4'3"10
213#
280#
2'0"6
111#
187#
2'
111#
187#
2'
111#
187#
2'
111#
187#
2'
111#
187#
2'
98#
190#
1'3"4
98#
190#
1'3"4
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'
98#
190#
2'0"6
392#
303#
7'0"6
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x4 SP 2400f-2.0E;
T2 2x4 SP M-30;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 6.31 26.98
BC 30 0.15 2.64
BC 75 2.18 10.84
BC 41 11.03 18.53
BC 75 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 722 /- /- /393 /292 /342
AC*432 /- /- /206 /113 /-
AT 1124 /- /- /521 /440 /-
R 1687 /- /- /929 /506 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
AC Brg Width = 83.6 Min Req = -
AT Brg Width = 7.6 Min Req = 1.5
R Brg Width = 7.6 Min Req = 2.0
Bearings B, AC, AT, & R are a rigid surface.
Bearings B, AT, & R require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 465 -353
C - D 382 -384
D - E 1971 -652
E - F 1970 -652
F - G 1027 -316
G - H 1040 -323
H - I 1059 -333
I - J 1057 -332
Chords Tens. Comp.
J - K 1036 -319
K - L 1038 -321
L - M 825 -922
M - N 826 -922
N - O 824 -920
O - P 1123 -1609
P - Q 1074 -1822
Q - R 1331 -2625
R - S 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AF 120 -64
C -AG 192 -34
AG-AE 303 -59
AE-AD 66 -110
AC-AB 2595 -4486
AB-AA 1226 -1963
AA- Y 2509 -4029
Chords Tens. Comp.
Z - X 5 -7
X - W 4 -5
W - V 1550 -579
V - U 1550 -579
U - T 2226 -999
T - R 2226 -998
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
AG-AF 58 -9
D -AE 154 0
D -AH 1183 -2374
AE-AI 417 -73
AH- E 69 -57
AI-AJ 40 -39
AI-AC 424 -71
AJ-AC 1184 -2378
AC-AD 54 0
AC- F 402 -809
Webs Tens. Comp.
AM- Y 896 -347
J - Y 250 -485
Y - Z 524 -1070
Y -AN 1215 -2096
Y -AO 1168 -374
AN-AQ 1204 -2072
AO-AP 1195 -393
AP- W 1181 -384
AQ- L 1208 -2080
L - W 127 -22
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.211 AF 620 360
VERT(CL): 0.424 AF 307 240
HORZ(LL): 0.107 AE - -
HORZ(TL): 0.216 AE - -
Creep Factor: 2.0
Max TC CSI: 0.944
Max BC CSI: 0.969
Max Web CSI: 0.724
Wgt: 245.0 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A14
Truss Type
GABL
Qty
1
Ply
1 2650
08/24/2020
11'0"6 6'11"10 3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
6'3"12 20'8"1'0"4 10'
2'7"10 8'4"4 7'4"12 19'7"6
1'4"
1'4"
38'
1'4"
4"34'10"12'4"3'5'4"35'11"2(a)
(a)
A
B
C
D E F G H I J K L M N O
P
Q
R
S
TUVWX
Y
Z
AAABACADAE
AFAG
AH
AI
AJ
AK
AL AM AN
AO
AP
AQ
AR
AS
AT
6
12
3X6(A1)
3X6(++)
1.5X4
6X8
3X4
6X8
3X4
3X6 3X6
5X6
6X8
3X6
4X4
3X10
5X6
3X6
5X6
3X8
3X4
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2 T1 2x4 SP 2400f-2.0E;
T2 2x4 SP M-30;
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X3 except as noted.
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 6.31 26.98
BC 30 0.15 2.64
BC 75 2.18 10.84
BC 41 11.03 18.53
BC 75 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 722 /- /- /393 /292 /342
AC*432 /- /- /206 /113 /-
AT 1124 /- /- /521 /440 /-
R 1687 /- /- /929 /506 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
AC Brg Width = 83.6 Min Req = -
AT Brg Width = 7.6 Min Req = 1.5
R Brg Width = 7.6 Min Req = 2.0
Bearings B, AC, AT, & R are a rigid surface.
Bearings B, AT, & R require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 465 -353
C - D 382 -384
D - E 1971 -652
E - F 1970 -652
F - G 1027 -316
G - H 1040 -323
H - I 1059 -333
I - J 1057 -332
Chords Tens. Comp.
J - K 1036 -319
K - L 1038 -321
L - M 825 -922
M - N 826 -922
N - O 824 -920
O - P 1123 -1609
P - Q 1074 -1822
Q - R 1331 -2625
R - S 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AF 120 -64
C -AG 192 -34
AG-AE 303 -59
AE-AD 66 -110
AC-AB 2595 -4486
AB-AA 1226 -1963
AA- Y 2509 -4029
Chords Tens. Comp.
Z - X 5 -7
X - W 4 -5
W - V 1550 -579
V - U 1550 -579
U - T 2226 -999
T - R 2226 -998
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
AG-AF 58 -9
D -AE 154 0
D -AH 1183 -2374
AE-AI 417 -73
AH- E 69 -57
AI-AJ 40 -39
AI-AC 424 -71
AJ-AC 1184 -2378
AC-AD 54 0
AC- F 402 -809
Webs Tens. Comp.
AM- Y 896 -347
J - Y 250 -485
Y - Z 524 -1070
Y -AN 1215 -2096
Y -AO 1168 -374
AN-AQ 1204 -2072
AO-AP 1195 -393
AP- W 1181 -384
AQ- L 1208 -2080
L - W 127 -22
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.211 AF 620 360
VERT(CL): 0.424 AF 307 240
HORZ(LL): 0.107 AE - -
HORZ(TL): 0.216 AE - -
Creep Factor: 2.0
Max TC CSI: 0.944
Max BC CSI: 0.969
Max Web CSI: 0.724
Wgt: 245.0 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A14
Truss Type
GABL
Qty
1
Ply
1 2650
08/24/2020
11'0"6 6'11"10 3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
6'3"12 20'8"1'0"4 10'
2'7"10 8'4"4 7'4"12 19'7"6
1'4"
1'4"
38'
1'4"
4"34'10"12'4"3'5'4"35'11"2(a)
(a)
A
B
C
D E F G H I J K L M N O
P
Q
R
S
TUVWX
Y
Z
AAABACADAE
AFAG
AH
AI
AJ
AK
AL AM AN
AO
AP
AQ
AR
AS
AT
6
12
3X6(A1)
3X6(++)
1.5X4
6X8
3X4
6X8
3X4
3X6 3X6
5X6
6X8
3X6
4X4
3X10
5X6
3X6
5X6
3X8
3X4
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
F -AK 955 -348
G -AK 81 -116
AB-AK 71 -89
AK-AL 934 -350
H -AL 236 -443
AA-AL 268 -501
AL-AM 909 -348
W -AR 411 -924
AR-AS 419 -937
AS- O 377 -855
O - U 451 -390
P - U 823 -620
U - Q 550 -856
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
AM- I 42 -78
K -AN 43 -80
X -AO 33 -46
AP-AQ 15 -24
Gables Tens. Comp.
M -AR 18 -11
N -AS 72 -118
Q - T 160 0
Truss
A14
Truss Type
GABL
Qty
1
Ply
1 2650
08/24/2020
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
Bot chord 2x4 SP 2400f-2.0E B1 2x4 SP #2;
Webs 2x4 SP #3 W1 2x4 SP 2400f-2.0E;
W6 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.77 27.56
BC 75 2.79 10.89
BC 91 10.93 18.53
BC 75 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
U 556 /- /- /291 /241 /351
V 1835 /- /- /959 /717 /-
J 738 /- /- /501 /258 /-
Wind reactions based on MWFRS
U Brg Width = 7.6 Min Req = 1.5
V Brg Width = 7.6 Min Req = 1.5
J Brg Width = 7.6 Min Req = 1.5
Bearings U, V, & J are a rigid surface.
Bearings U, V, & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - C 1689 -1943
A - B 27 0
B - U 1619 -1681
C - D 360 -598
D - E 1599 -675
E - F 1599 -675
Chords Tens. Comp.
F - G 1596 -671
G - H 303 -214
H - I 332 -660
I - J 481 -1012
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - S 633 -109
S - R 18 -17
Q - O 595 -141
P - N 20 -19
Chords Tens. Comp.
N - M 524 -63
M - L 524 -63
L - J 853 -325
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - T 2457 -1078
C - S 75 -126
C - Q 128 -190
S - Q 625 -87
Q - R 20 0
Q - D 317 -52
D - O 1034 -2233
F - O 287 -436
Webs Tens. Comp.
O - P 825 -1806
O - G 916 -1693
O - N 267 -381
G - N 593 -248
N - H 238 -605
H - L 400 -69
L - I 300 -379
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.200 C 999 360
VERT(CL): 0.378 C 596 240
HORZ(LL): 0.091 C - -
HORZ(TL): 0.173 C - -
Creep Factor: 2.0
Max TC CSI: 0.472
Max BC CSI: 0.323
Max Web CSI: 0.789
Wgt: 214.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A15
Truss Type
COMN
Qty
1
Ply
1 2656
08/24/2020
18'3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
7'9"4 19'9"8 10'5"4
11'0"6 7'4"4 19'7"61'4"1'4"
38'
1'4"
4"3
2'4"3'5'6"136'1"12(a)
A
B
C D E F G H
I
J
K
LMN
O
P
Q RST
U
V
6
12
3X3
3X3
3X10
2X4(R)
2X4(R)
5X8
3X4
5X6
1.5X3
4X4 4X6
1.5X3
6X8
3X6
4X4
3X8 3X6
5X6
3X4
1.5X3
3X6(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
Bot chord 2x4 SP 2400f-2.0E B1 2x4 SP #2;
Webs 2x4 SP #3 W1 2x4 SP 2400f-2.0E;
W6 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.77 27.56
BC 75 2.79 10.89
BC 91 10.93 18.53
BC 75 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
U 556 /- /- /291 /241 /351
V 1835 /- /- /959 /717 /-
J 738 /- /- /501 /258 /-
Wind reactions based on MWFRS
U Brg Width = 7.6 Min Req = 1.5
V Brg Width = 7.6 Min Req = 1.5
J Brg Width = 7.6 Min Req = 1.5
Bearings U, V, & J are a rigid surface.
Bearings U, V, & J require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - C 1689 -1943
A - B 27 0
B - U 1619 -1681
C - D 360 -598
D - E 1599 -675
E - F 1599 -675
Chords Tens. Comp.
F - G 1596 -671
G - H 303 -214
H - I 332 -660
I - J 481 -1012
J - K 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
T - S 633 -109
S - R 18 -17
Q - O 595 -141
P - N 20 -19
Chords Tens. Comp.
N - M 524 -63
M - L 524 -63
L - J 853 -325
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - T 2457 -1078
C - S 75 -126
C - Q 128 -190
S - Q 625 -87
Q - R 20 0
Q - D 317 -52
D - O 1034 -2233
F - O 287 -436
Webs Tens. Comp.
O - P 825 -1806
O - G 916 -1693
O - N 267 -381
G - N 593 -248
N - H 238 -605
H - L 400 -69
L - I 300 -379
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.200 C 999 360
VERT(CL): 0.378 C 596 240
HORZ(LL): 0.091 C - -
HORZ(TL): 0.173 C - -
Creep Factor: 2.0
Max TC CSI: 0.472
Max BC CSI: 0.323
Max Web CSI: 0.789
Wgt: 214.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
A15
Truss Type
COMN
Qty
1
Ply
1 2656
08/24/2020
18'3"13 19'8"3
SEAT PLATE REQ.SEAT PLATE REQ.SEAT PLATE REQ.
7'9"4 19'9"8 10'5"4
11'0"6 7'4"4 19'7"61'4"1'4"
38'
1'4"
4"3
2'4"3'5'6"136'1"12(a)
A
B
C D E F G H
I
J
K
LMN
O
P
Q RST
U
V
6
12
3X3
3X3
3X10
2X4(R)
2X4(R)
5X8
3X4
5X6
1.5X3
4X4 4X6
1.5X3
6X8
3X6
4X4
3X8 3X6
5X6
3X4
1.5X3
3X6(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 843 /- /- /491 /210 /167
F 843 /- /- /491 /210 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
F Brg Width = 7.6 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 918 -1253
C - D 735 -926
Chords Tens. Comp.
D - E 736 -926
E - F 918 -1253
F - G 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 1068 -668
Chords Tens. Comp.
H - F 1068 -679
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - H 421 -344
D - H 518 -285
Webs Tens. Comp.
H - E 420 -344
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.039 H 999 360
VERT(CL): 0.074 H 999 240
HORZ(LL): 0.017 H - -
HORZ(TL): 0.033 H - -
Creep Factor: 2.0
Max TC CSI: 0.302
Max BC CSI: 0.854
Max Web CSI: 0.201
Wgt: 88.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
B01
Truss Type
COMN
Qty
2
Ply
1 4503
08/24/2020
20'
SEAT PLATE REQ.SEAT PLATE REQ.
10'10'
1'4"1'4"
4"35'4"35'11"2A
B
C
D
E
F
G
H
6
12
3X4(A1)
1.5X3
4X4
5X6
1.5X3
3X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 843 /- /- /491 /210 /167
F 843 /- /- /491 /210 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
F Brg Width = 7.6 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 918 -1253
C - D 735 -926
Chords Tens. Comp.
D - E 736 -926
E - F 918 -1253
F - G 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 1068 -668
Chords Tens. Comp.
H - F 1068 -679
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - H 421 -344
D - H 518 -285
Webs Tens. Comp.
H - E 420 -344
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.039 H 999 360
VERT(CL): 0.074 H 999 240
HORZ(LL): 0.017 H - -
HORZ(TL): 0.033 H - -
Creep Factor: 2.0
Max TC CSI: 0.302
Max BC CSI: 0.854
Max Web CSI: 0.201
Wgt: 88.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
B01
Truss Type
COMN
Qty
2
Ply
1 4503
08/24/2020
20'
SEAT PLATE REQ.SEAT PLATE REQ.
10'10'
1'4"1'4"
4"35'4"35'11"2A
B
C
D
E
F
G
H
6
12
3X4(A1)
1.5X3
4X4
5X6
1.5X3
3X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 393 /- /- /206 /121 /329
L* 163 /- /- /62 /48 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
L Brg Width = 232 Min Req = -
Bearings B & B are a rigid surface.
Bearings B & B require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 182 -222
C - D 184 -191
D - E 218 -162
E - F 354 -133
F - G 508 -106
Chords Tens. Comp.
G - H 517 -90
H - I 363 -72
I - J 228 -80
J - K 93 -82
K - L 45 -153
L - M 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 311 -117
W - V 325 -116
V - U 334 -115
U - T 341 -115
T - S 349 -115
S - R 349 -115
Chords Tens. Comp.
R - Q 349 -115
Q - P 344 -112
P - O 338 -110
O - N 328 -106
N - L 314 -103
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - S 29 -291
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - W 223 -209
D - V 293 -308
E - U 284 -302
F - T 502 -377
Gables Tens. Comp.
Q - H 503 -377
P - I 284 -302
O - J 293 -308
N - K 223 -209
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.001 F 999 360
VERT(CL): 0.003 F 999 240
HORZ(LL): 0.004 J - -
HORZ(TL): 0.004 J - -
Creep Factor: 2.0
Max TC CSI: 0.373
Max BC CSI: 0.128
Max Web CSI: 0.146
Wgt: 99.4 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
B02E
Truss Type
GABL
Qty
1
Ply
1 2647
08/24/2020
20'
SEAT PLATE REQ.SEAT PLATE REQ.
10'10'
1'4"1'4"
4"35'4"35'11"2A
B
C
D
E
F
G
H
I
J
K
L
M
NOPQRSTUVW
6
12
2X4(A1)
1.5X4
4X4
3X4
1.5X4
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 393 /- /- /206 /121 /329
L* 163 /- /- /62 /48 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
L Brg Width = 232 Min Req = -
Bearings B & B are a rigid surface.
Bearings B & B require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 182 -222
C - D 184 -191
D - E 218 -162
E - F 354 -133
F - G 508 -106
Chords Tens. Comp.
G - H 517 -90
H - I 363 -72
I - J 228 -80
J - K 93 -82
K - L 45 -153
L - M 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 311 -117
W - V 325 -116
V - U 334 -115
U - T 341 -115
T - S 349 -115
S - R 349 -115
Chords Tens. Comp.
R - Q 349 -115
Q - P 344 -112
P - O 338 -110
O - N 328 -106
N - L 314 -103
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - S 29 -291
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - W 223 -209
D - V 293 -308
E - U 284 -302
F - T 502 -377
Gables Tens. Comp.
Q - H 503 -377
P - I 284 -302
O - J 293 -308
N - K 223 -209
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.001 F 999 360
VERT(CL): 0.003 F 999 240
HORZ(LL): 0.004 J - -
HORZ(TL): 0.004 J - -
Creep Factor: 2.0
Max TC CSI: 0.373
Max BC CSI: 0.128
Max Web CSI: 0.146
Wgt: 99.4 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
B02E
Truss Type
GABL
Qty
1
Ply
1 2647
08/24/2020
20'
SEAT PLATE REQ.SEAT PLATE REQ.
10'10'
1'4"1'4"
4"35'4"35'11"2A
B
C
D
E
F
G
H
I
J
K
L
M
NOPQRSTUVW
6
12
2X4(A1)
1.5X4
4X4
3X4
1.5X4
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
F* 181 /- /- /72 /110 /19
Wind reactions based on MWFRS
F Brg Width = 140 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 182 -159
C - D 407 -139
Chords Tens. Comp.
D - E 393 -139
E - F 167 -159
F - G 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 243 -70
J - I 260 -74
Chords Tens. Comp.
I - H 260 -74
H - F 236 -77
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - J 699 -457
D - I 20 -164
Gables Tens. Comp.
H - E 699 -457
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 J 999 360
VERT(CL): 0.004 J 999 240
HORZ(LL): -0.004 J - -
HORZ(TL): 0.004 J - -
Creep Factor: 2.0
Max TC CSI: 0.550
Max BC CSI: 0.111
Max Web CSI: 0.148
Wgt: 51.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C01
Truss Type
GABL
Qty
1
Ply
1 2668
08/24/2020
11'8"
SEAT PLATE REQ.
5'10"5'10"
1'4"1'4"
4"33'3"33'10"2A
B
C
D
E
F
G
HIJ
6
12
2X4(A1)
3X3
4X4
3X3
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
F* 181 /- /- /72 /110 /19
Wind reactions based on MWFRS
F Brg Width = 140 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 75 0
B - C 182 -159
C - D 407 -139
Chords Tens. Comp.
D - E 393 -139
E - F 167 -159
F - G 75 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 243 -70
J - I 260 -74
Chords Tens. Comp.
I - H 260 -74
H - F 236 -77
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - J 699 -457
D - I 20 -164
Gables Tens. Comp.
H - E 699 -457
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 J 999 360
VERT(CL): 0.004 J 999 240
HORZ(LL): -0.004 J - -
HORZ(TL): 0.004 J - -
Creep Factor: 2.0
Max TC CSI: 0.550
Max BC CSI: 0.111
Max Web CSI: 0.148
Wgt: 51.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C01
Truss Type
GABL
Qty
1
Ply
1 2668
08/24/2020
11'8"
SEAT PLATE REQ.
5'10"5'10"
1'4"1'4"
4"33'3"33'10"2A
B
C
D
E
F
G
HIJ
6
12
2X4(A1)
3X3
4X4
3X3
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 525 /- /- /320 /133 /111
D 525 /- /- /239 /133 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 7.6 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 534 -528
Chords Tens. Comp.
C - D 534 -528
D - E 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 423 -257
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.016 999 360
VERT(CL): 0.048 999 240
HORZ(LL): -0.010 - -
HORZ(TL): 0.030 - -
Creep Factor: 2.0
Max TC CSI: 0.514
Max BC CSI: 0.740
Max Web CSI: 0.000
Wgt: 42.0 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C02
Truss Type
COMN
Qty
1
Ply
1 2674
08/24/2020
11'8"
SEAT PLATE REQ.SEAT PLATE REQ.
5'10"5'10"
1'4"1'4"
4"33'3"33'10"2A
B
C
D
E
6
12
2X4(A1)
3X4(R1)
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.15 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 525 /- /- /320 /133 /111
D 525 /- /- /239 /133 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 7.6 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 534 -528
Chords Tens. Comp.
C - D 534 -528
D - E 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 423 -257
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.016 999 360
VERT(CL): 0.048 999 240
HORZ(LL): -0.010 - -
HORZ(TL): 0.030 - -
Creep Factor: 2.0
Max TC CSI: 0.514
Max BC CSI: 0.740
Max Web CSI: 0.000
Wgt: 42.0 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C02
Truss Type
COMN
Qty
1
Ply
1 2674
08/24/2020
11'8"
SEAT PLATE REQ.SEAT PLATE REQ.
5'10"5'10"
1'4"1'4"
4"33'3"33'10"2A
B
C
D
E
6
12
2X4(A1)
3X4(R1)
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
(**) 2 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
BC 88 2.18 9.48
BC 30 9.03 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 525 /- /- /314 /244 /115
F 525 /- /- /314 /244 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
F Brg Width = 7.6 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 204 -296
C - D 354 -787
Chords Tens. Comp.
D - E 342 -787
E - F 218 -296
F - G 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 100 -43
C - L 629 -133
L - J 747 -180
Chords Tens. Comp.
J - H 747 -180
I - F 100 -47
H - E 629 -123
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
L - K 76 -9
D - J 164 0
Webs Tens. Comp.
I - H 76 -10
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.220 K 619 360
VERT(CL): 0.406 K 335 240
HORZ(LL): 0.225 H - -
HORZ(TL): 0.415 H - -
Creep Factor: 2.0
Max TC CSI: 0.475
Max BC CSI: 0.333
Max Web CSI: 0.448
Wgt: 50.4 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C03
Truss Type
COMN
Qty
1
Ply
1 2665
08/24/2020
11'8"
SEAT PLATE REQ.SEAT PLATE REQ.
5'10"5'10"
2'7"10 6'4"12 2'7"101'4"1'4"
4"31'3'3"33'10"2A
B
C
D
E
F
G
HIJ
KL
6
12
2X4(A1)
2X4(**)
3X3
1.5X4
4X4(R1)
1.5X3
1.5X4
3X3
2X4(**)
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP 2400f-2.0E
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
(**) 2 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
BC 88 2.18 9.48
BC 30 9.03 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 525 /- /- /314 /244 /115
F 525 /- /- /314 /244 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
F Brg Width = 7.6 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 204 -296
C - D 354 -787
Chords Tens. Comp.
D - E 342 -787
E - F 218 -296
F - G 35 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 100 -43
C - L 629 -133
L - J 747 -180
Chords Tens. Comp.
J - H 747 -180
I - F 100 -47
H - E 629 -123
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
L - K 76 -9
D - J 164 0
Webs Tens. Comp.
I - H 76 -10
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.220 K 619 360
VERT(CL): 0.406 K 335 240
HORZ(LL): 0.225 H - -
HORZ(TL): 0.415 H - -
Creep Factor: 2.0
Max TC CSI: 0.475
Max BC CSI: 0.333
Max Web CSI: 0.448
Wgt: 50.4 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
C03
Truss Type
COMN
Qty
1
Ply
1 2665
08/24/2020
11'8"
SEAT PLATE REQ.SEAT PLATE REQ.
5'10"5'10"
2'7"10 6'4"12 2'7"101'4"1'4"
4"31'3'3"33'10"2A
B
C
D
E
F
G
HIJ
KL
6
12
2X4(A1)
2X4(**)
3X3
1.5X4
4X4(R1)
1.5X3
1.5X4
3X3
2X4(**)
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 0.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 197 /- /- /175 /107 /53
D 6 /-11 /- /17 /13 /-
C - /-33 /- /39 /42 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -29
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.000 D - -
HORZ(TL): 0.000 D - -
Creep Factor: 2.0
Max TC CSI: 0.282
Max BC CSI: 0.036
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ1
Truss Type
JACK
Qty
2
Ply
1 2680
08/24/2020
SEAT PLATE REQ.
11"111'4"
4"3 10"1'5"A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 0.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 197 /- /- /175 /107 /53
D 6 /-11 /- /17 /13 /-
C - /-33 /- /39 /42 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -29
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.000 D - -
HORZ(TL): 0.000 D - -
Creep Factor: 2.0
Max TC CSI: 0.282
Max BC CSI: 0.036
Max Web CSI: 0.000
Wgt: 5.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ1
Truss Type
JACK
Qty
2
Ply
1 2680
08/24/2020
SEAT PLATE REQ.
11"111'4"
4"3 10"1'5"A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 11 0.00 0.91
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 178 /- /- /171 /81 /-
D 15 /- /- /10 /- /-
C - /-32 /- /46 /60 /33
Wind reactions based on MWFRS
E Brg Width = 6.9 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
Chords Tens. Comp.
B - C 151 -59
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 317 -172
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 B 999 360
VERT(CL): 0.000 B 999 240
HORZ(LL): 0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.180
Max BC CSI: 0.007
Max Web CSI: 0.094
Wgt: 8.4 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ1A
Truss Type
JACK
Qty
1
Ply
1 2521
08/24/2020
SEAT PLATE REQ.
3"8 7"71'4"12
10"151'8"92'2"HB 7"7
A
B
C
DE
6
12
1.5X4
3X6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 11 0.00 0.91
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 178 /- /- /171 /81 /-
D 15 /- /- /10 /- /-
C - /-32 /- /46 /60 /33
Wind reactions based on MWFRS
E Brg Width = 6.9 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
Chords Tens. Comp.
B - C 151 -59
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 317 -172
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 B 999 360
VERT(CL): 0.000 B 999 240
HORZ(LL): 0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.180
Max BC CSI: 0.007
Max Web CSI: 0.094
Wgt: 8.4 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ1A
Truss Type
JACK
Qty
1
Ply
1 2521
08/24/2020
SEAT PLATE REQ.
3"8 7"71'4"12
10"151'8"92'2"HB 7"7
A
B
C
DE
6
12
1.5X4
3X6
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 2.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 220 /- /- /167 /51 /62
D 43 /- /- /31 /2 /-
C 66 /- /- /28 /29 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 30 -89
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.322
Max BC CSI: 0.072
Max Web CSI: 0.000
Wgt: 11.2 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ3
Truss Type
JACK
Qty
3
Ply
1 2522
08/24/2020
SEAT PLATE REQ.
2'11"111'4"
4"3 1'10"2'5"A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 2.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 220 /- /- /167 /51 /62
D 43 /- /- /31 /2 /-
C 66 /- /- /28 /29 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 30 -89
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.322
Max BC CSI: 0.072
Max Web CSI: 0.000
Wgt: 11.2 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ3
Truss Type
JACK
Qty
3
Ply
1 2522
08/24/2020
SEAT PLATE REQ.
2'11"111'4"
4"3 1'10"2'5"A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 27 0.00 2.24
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 193 /- /- /169 /76 /-
D 38 /- /- /23 /- /-
C 45 /- /- /38 /15 /53
Wind reactions based on MWFRS
E Brg Width = 6.9 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
Chords Tens. Comp.
B - C 156 -52
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 305 -178
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 B 999 360
VERT(CL): 0.000 B 999 240
HORZ(LL): -0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.197
Max BC CSI: 0.050
Max Web CSI: 0.091
Wgt: 14.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ3A
Truss Type
JACK
Qty
1
Ply
1 2523
08/24/2020
SEAT PLATE REQ.
3"8 1'11"7
1'4"12
2'2"151'8"92'10"HB 1'11"7
A
B
C
DE
6
12
1.5X4
3X6
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 27 0.00 2.24
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 193 /- /- /169 /76 /-
D 38 /- /- /23 /- /-
C 45 /- /- /38 /15 /53
Wind reactions based on MWFRS
E Brg Width = 6.9 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 37 0
Chords Tens. Comp.
B - C 156 -52
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 305 -178
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 B 999 360
VERT(CL): 0.000 B 999 240
HORZ(LL): -0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.197
Max BC CSI: 0.050
Max Web CSI: 0.091
Wgt: 14.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
CJ3A
Truss Type
JACK
Qty
1
Ply
1 2523
08/24/2020
SEAT PLATE REQ.
3"8 1'11"7
1'4"12
2'2"151'8"92'10"HB 1'11"7
A
B
C
DE
6
12
1.5X4
3X6
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 4.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 288 /- /- /203 /107 /157
D 77 /- /- /36 /- /-
C 128 /- /- /76 /111 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -152
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.005 D - -
HORZ(TL): 0.008 D - -
Creep Factor: 2.0
Max TC CSI: 0.542
Max BC CSI: 0.252
Max Web CSI: 0.000
Wgt: 18.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ5
Truss Type
JACK
Qty
2
Ply
1 2704
08/24/2020
SEAT PLATE REQ.
4'11"111'4"
4"3 2'10"3'5"A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 4.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 288 /- /- /203 /107 /157
D 77 /- /- /36 /- /-
C 128 /- /- /76 /111 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -152
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.005 D - -
HORZ(TL): 0.008 D - -
Creep Factor: 2.0
Max TC CSI: 0.542
Max BC CSI: 0.252
Max Web CSI: 0.000
Wgt: 18.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ5
Truss Type
JACK
Qty
2
Ply
1 2704
08/24/2020
SEAT PLATE REQ.
4'11"111'4"
4"3 2'10"3'5"A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 4.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 288 /- /- /253 /75 /92
D 77 /- /- /89 /35 /-
C 128 /- /- /69 /53 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -156
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.005 D - -
HORZ(TL): 0.008 D - -
Creep Factor: 2.0
Max TC CSI: 0.510
Max BC CSI: 0.284
Max Web CSI: 0.000
Wgt: 18.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ5P
Truss Type
JACK
Qty
1
Ply
1 2713
08/24/2020
SEAT PLATE REQ.
4'11"111'4"
4"3 2'10"3'5"A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 4.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 288 /- /- /253 /75 /92
D 77 /- /- /89 /35 /-
C 128 /- /- /69 /53 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 57 -156
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.005 D - -
HORZ(TL): 0.008 D - -
Creep Factor: 2.0
Max TC CSI: 0.510
Max BC CSI: 0.284
Max Web CSI: 0.000
Wgt: 18.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
CJ5P
Truss Type
JACK
Qty
1
Ply
1 2713
08/24/2020
SEAT PLATE REQ.
4'11"111'4"
4"3 2'10"3'5"A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.89 to 61 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 9.84
BC: From 2 plf at 0.00 to 2 plf at 9.84
TC: -20 lb Conc. Load at 1.38
TC: 132 lb Conc. Load at 4.21
TC: 256 lb Conc. Load at 7.03
BC: 12 lb Conc. Load at 1.38
BC: 86 lb Conc. Load at 4.21
BC: 155 lb Conc. Load at 7.03
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 321 /- /- /- /211 /-
E 281 /- /0 /- /94 /0
D 116 /- /- /- /87 /-
Wind reactions based on MWFRS
B Brg Width = 10.0 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 19 -8
B - C 402 -840
Chords Tens. Comp.
C - D 62 -94
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - G 798 -372
G - F 786 -372
Chords Tens. Comp.
F - E 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - C 196 0
Webs Tens. Comp.
C - F 386 -814
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.027 G 999 360
VERT(CL): 0.050 G 999 240
HORZ(LL): 0.007 F - -
HORZ(TL): 0.013 F - -
Creep Factor: 2.0
Max TC CSI: 0.486
Max BC CSI: 0.794
Max Web CSI: 0.568
Wgt: 44.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
HJ7
Truss Type
HIP_
Qty
1
Ply
1 2689
08/24/2020
SEAT PLATE REQ.
9'10"11'10"10
4"3 3'9"144'5"1A
B
C
D
EFG
4.24
12
2X4(A1)
1.5X3
3X4
4X4
1'4"8
12#
-20#
2'9"15
86#
132#
2'9"15
155#
256#
2'9"10
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.89 to 61 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 9.84
BC: From 2 plf at 0.00 to 2 plf at 9.84
TC: -20 lb Conc. Load at 1.38
TC: 132 lb Conc. Load at 4.21
TC: 256 lb Conc. Load at 7.03
BC: 12 lb Conc. Load at 1.38
BC: 86 lb Conc. Load at 4.21
BC: 155 lb Conc. Load at 7.03
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 321 /- /- /- /211 /-
E 281 /- /0 /- /94 /0
D 116 /- /- /- /87 /-
Wind reactions based on MWFRS
B Brg Width = 10.0 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 19 -8
B - C 402 -840
Chords Tens. Comp.
C - D 62 -94
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - G 798 -372
G - F 786 -372
Chords Tens. Comp.
F - E 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - C 196 0
Webs Tens. Comp.
C - F 386 -814
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.027 G 999 360
VERT(CL): 0.050 G 999 240
HORZ(LL): 0.007 F - -
HORZ(TL): 0.013 F - -
Creep Factor: 2.0
Max TC CSI: 0.486
Max BC CSI: 0.794
Max Web CSI: 0.568
Wgt: 44.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
HJ7
Truss Type
HIP_
Qty
1
Ply
1 2689
08/24/2020
SEAT PLATE REQ.
9'10"11'10"10
4"3 3'9"144'5"1A
B
C
D
EFG
4.24
12
2X4(A1)
1.5X3
3X4
4X4
1'4"8
12#
-20#
2'9"15
86#
132#
2'9"15
155#
256#
2'9"10
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.97 to 61 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 5.98
BC: From 2 plf at 0.00 to 2 plf at 5.98
TC: 66 lb Conc. Load at 0.35
TC: -12 lb Conc. Load at 1.29
TC: 173 lb Conc. Load at 3.17
BC: 43 lb Conc. Load at 0.35
BC: 15 lb Conc. Load at 1.29
BC: 116 lb Conc. Load at 3.17
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 72 0.00 5.98
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 320 /- /- /- /141 /-
D 102 /- /- /- /12 /-
C 93 /- /- /- /42 /-
Wind reactions based on MWFRS
E Brg Width = 9.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 20 -9
Chords Tens. Comp.
B - C 34 -49
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 131 -207
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.000 B 999 360
VERT(CL): 0.001 B 999 240
HORZ(LL): 0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.723
Max BC CSI: 0.562
Max Web CSI: 0.039
Wgt: 0.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
HJ7S
Truss Type
HIP_
Qty
1
Ply
1 2537
08/24/2020
SEAT PLATE REQ.
3"8 5'8"41'11"11
5'11"121'8"93'9"14HB 5'8"4
A
B
C
DE
4.24
12
1.5X4
1.5X4
4"3
43#
66#
11"5
15#
-12#
1'10"10
116#
173#
2'9"10
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.97 to 61 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 5.98
BC: From 2 plf at 0.00 to 2 plf at 5.98
TC: 66 lb Conc. Load at 0.35
TC: -12 lb Conc. Load at 1.29
TC: 173 lb Conc. Load at 3.17
BC: 43 lb Conc. Load at 0.35
BC: 15 lb Conc. Load at 1.29
BC: 116 lb Conc. Load at 3.17
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 72 0.00 5.98
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 320 /- /- /- /141 /-
D 102 /- /- /- /12 /-
C 93 /- /- /- /42 /-
Wind reactions based on MWFRS
E Brg Width = 9.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 20 -9
Chords Tens. Comp.
B - C 34 -49
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
E - D 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - E 131 -207
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld Case
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.000 B 999 360
VERT(CL): 0.001 B 999 240
HORZ(LL): 0.000 B - -
HORZ(TL): 0.000 B - -
Creep Factor: 2.0
Max TC CSI: 0.723
Max BC CSI: 0.562
Max Web CSI: 0.039
Wgt: 0.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
HJ7S
Truss Type
HIP_
Qty
1
Ply
1 2537
08/24/2020
SEAT PLATE REQ.
3"8 5'8"41'11"11
5'11"121'8"93'9"14HB 5'8"4
A
B
C
DE
4.24
12
1.5X4
1.5X4
4"3
43#
66#
11"5
15#
-12#
1'10"10
116#
173#
2'9"10
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 106 /- /- /76 /13 /15
Wind reactions based on MWFRS
D Brg Width = 31.7 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 23 -53
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 155 -31
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - D 89 -54
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.186
Max BC CSI: 0.046
Max Web CSI: 0.038
Wgt: 14.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
J3GE
Truss Type
JACK
Qty
1
Ply
1 2527
08/24/2020
2'7"11
SEAT PLATE REQ.
1'4"
4"3 1'8"2'3"A
B
C
D
6
12
2X4(A1)
1.5X4
1.5X4
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 106 /- /- /76 /13 /15
Wind reactions based on MWFRS
D Brg Width = 31.7 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 23 -53
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 155 -31
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - D 89 -54
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.186
Max BC CSI: 0.046
Max Web CSI: 0.038
Wgt: 14.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
J3GE
Truss Type
JACK
Qty
1
Ply
1 2527
08/24/2020
2'7"11
SEAT PLATE REQ.
1'4"
4"3 1'8"2'3"A
B
C
D
6
12
2X4(A1)
1.5X4
1.5X4
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /245 /126 /210
D 111 /- /- /55 /- /-
C 187 /- /- /113 /161 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 84 -135
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 D - -
HORZ(TL): 0.027 D - -
Creep Factor: 2.0
Max TC CSI: 0.711
Max BC CSI: 0.452
Max Web CSI: 0.000
Wgt: 23.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
J7
Truss Type
EJAC
Qty
2
Ply
1 2701
08/24/2020
SEAT PLATE REQ.
7'1'4"
4"3 3'10"34'5"2A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /245 /126 /210
D 111 /- /- /55 /- /-
C 187 /- /- /113 /161 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 84 -135
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 25.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 D - -
HORZ(TL): 0.027 D - -
Creep Factor: 2.0
Max TC CSI: 0.711
Max BC CSI: 0.452
Max Web CSI: 0.000
Wgt: 23.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
J7
Truss Type
EJAC
Qty
2
Ply
1 2701
08/24/2020
SEAT PLATE REQ.
7'1'4"
4"3 3'10"34'5"2A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
BC 58 2.18 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /252 /68 /121
E 98 /- /- /66 /8 /-
D 190 /- /- /102 /78 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 0 -197
Chords Tens. Comp.
C - D 85 -118
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 84 -73
C - G 81 -36
Chords Tens. Comp.
G - E 0 0
H - F 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - H 72 -34
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.171 F 482 360
VERT(CL): 0.316 F 260 240
HORZ(LL): 0.081 G - -
HORZ(TL): 0.151 G - -
Creep Factor: 2.0
Max TC CSI: 0.786
Max BC CSI: 0.348
Max Web CSI: 0.279
Wgt: 28.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
J7C
Truss Type
EJAC
Qty
8
Ply
1 2529
08/24/2020
SEAT PLATE REQ.
2'6"2 1"8 4'4"61'4"
7'
4"3 1'2'10"33'10"34'5"2HB 4'5"14
A
B
C
D
E
FGH
6
12
2X4(A1)
3X4(++)
1.5X4
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.64
BC 58 2.18 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /252 /68 /121
E 98 /- /- /66 /8 /-
D 190 /- /- /102 /78 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
B - C 0 -197
Chords Tens. Comp.
C - D 85 -118
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - H 84 -73
C - G 81 -36
Chords Tens. Comp.
G - E 0 0
H - F 0 0
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
G - H 72 -34
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.171 F 482 360
VERT(CL): 0.316 F 260 240
HORZ(LL): 0.081 G - -
HORZ(TL): 0.151 G - -
Creep Factor: 2.0
Max TC CSI: 0.786
Max BC CSI: 0.348
Max Web CSI: 0.279
Wgt: 28.0 lbs
VIEW Ver: 19.01.00A.0618.15
Job
WRMSBM1674B
Truss
J7C
Truss Type
EJAC
Qty
8
Ply
1 2529
08/24/2020
SEAT PLATE REQ.
2'6"2 1"8 4'4"61'4"
7'
4"3 1'2'10"33'10"34'5"2HB 4'5"14
A
B
C
D
E
FGH
6
12
2X4(A1)
3X4(++)
1.5X4
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /317 /88 /121
D 111 /- /- /131 /52 /-
C 187 /- /- /102 /77 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 84 -154
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 D - -
HORZ(TL): 0.027 D - -
Creep Factor: 2.0
Max TC CSI: 0.711
Max BC CSI: 0.640
Max Web CSI: 0.000
Wgt: 23.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
J7P
Truss Type
EJAC
Qty
5
Ply
1 2716
08/24/2020
SEAT PLATE REQ.
7'1'4"
4"3 3'10"34'5"2A
B
C
D
6
12
2X4(A1)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 361 /- /- /317 /88 /121
D 111 /- /- /131 /52 /-
C 187 /- /- /102 /77 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 0
Chords Tens. Comp.
B - C 84 -154
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 0 0
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 D - -
HORZ(TL): 0.027 D - -
Creep Factor: 2.0
Max TC CSI: 0.711
Max BC CSI: 0.640
Max Web CSI: 0.000
Wgt: 23.8 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
J7P
Truss Type
EJAC
Qty
5
Ply
1 2716
08/24/2020
SEAT PLATE REQ.
7'1'4"
4"3 3'10"34'5"2A
B
C
D
6
12
2X4(A1)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 7.14
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E* 76 /- /- /34 /1 /5
Wind reactions based on MWFRS
E Brg Width = 85.6 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 172 -110
Chords Tens. Comp.
B - C 172 -110
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - D 163 -122
Chords Tens. Comp.
D - C 163 -122
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - D 270 -281
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.005 D 999 360
VERT(CL): 0.010 D 999 240
HORZ(LL): -0.002 D - -
HORZ(TL): 0.004 D - -
Creep Factor: 2.0
Max TC CSI: 0.149
Max BC CSI: 0.131
Max Web CSI: 0.080
Wgt: 25.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
V01
Truss Type
VAL
Qty
1
Ply
1 2695
08/24/2020
7'1"10
6"15 2'11"14 2'11"14 6"15
3'5"1 3"8 3'5"1
0"41'9"11A
B
C
D
E
6
12
2X4(D8R)
4X4
1.5X3
2X4(D8R)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 7.14
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
E* 76 /- /- /34 /1 /5
Wind reactions based on MWFRS
E Brg Width = 85.6 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 172 -110
Chords Tens. Comp.
B - C 172 -110
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - D 163 -122
Chords Tens. Comp.
D - C 163 -122
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - D 270 -281
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.005 D 999 360
VERT(CL): 0.010 D 999 240
HORZ(LL): -0.002 D - -
HORZ(TL): 0.004 D - -
Creep Factor: 2.0
Max TC CSI: 0.149
Max BC CSI: 0.131
Max Web CSI: 0.080
Wgt: 25.2 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
V01
Truss Type
VAL
Qty
1
Ply
1 2695
08/24/2020
7'1"10
6"15 2'11"14 2'11"14 6"15
3'5"1 3"8 3'5"1
0"41'9"11A
B
C
D
E
6
12
2X4(D8R)
4X4
1.5X3
2X4(D8R)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 51 0.00 4.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 76 /- /- /31 /- /4
Wind reactions based on MWFRS
D Brg Width = 50.6 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 172 -185
Chords Tens. Comp.
B - C 172 -185
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - C 177 -129
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.004 999 360
VERT(CL): 0.008 999 240
HORZ(LL): -0.002 - -
HORZ(TL): 0.003 - -
Creep Factor: 2.0
Max TC CSI: 0.077
Max BC CSI: 0.107
Max Web CSI: 0.000
Wgt: 12.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
V02
Truss Type
VAL
Qty
1
Ply
1 2698
08/24/2020
4'2"10
6"15 1'6"6 1'6"6 6"15
0"41'0"15A
B
C
D
6
12
2X4(D8R)
3X4
2X4(D8R)
**WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses.
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 51 0.00 4.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 76 /- /- /31 /- /4
Wind reactions based on MWFRS
D Brg Width = 50.6 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 172 -185
Chords Tens. Comp.
B - C 172 -185
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - C 177 -129
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Code / Misc Criteria
Code:FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.004 999 360
VERT(CL): 0.008 999 240
HORZ(LL): -0.002 - -
HORZ(TL): 0.003 - -
Creep Factor: 2.0
Max TC CSI: 0.077
Max BC CSI: 0.107
Max Web CSI: 0.000
Wgt: 12.6 lbs
VIEW Ver: 20.01.01A.0724.11
Job
WRMSBM1674B
Truss
V02
Truss Type
VAL
Qty
1
Ply
1 2698
08/24/2020
4'2"10
6"15 1'6"6 1'6"6 6"15
0"41'0"15A
B
C
D
6
12
2X4(D8R)
3X4
2X4(D8R)
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION
CORNERSET GENERAL SPECIFICATIONS
Attach King Jack w/ (3) 16d Toe
Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
Attach Corner Jack's
w/ (2) 16d Toe Nails
@ TC & BC (Typ)
Attach Corner Jack's
w/ (2) 16d Toe Nails @ TC &
BC (Typ) 7'-0" MAX ST-CRNRST
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
STDTL01
BC
JUNE 20, 2019
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL03ALTERNATE GABLE END BRACING DETAILFEBRUARY 17, 2017
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
PIGGY-BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
PIGGY-BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY-BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
**REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY-BACK AND BASE
TRUSS SPECIFICATIONS.**
OPTION NO. 2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO. 3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 10d BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI-USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY-BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI-USE CONNECTION PLATE (MINIMUM OF 2
PLATES).
OPTION #1: TEE-LOK MULTI-USE
CONNECTION PLATE.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
2'-0"
MAX
PIGGY-BACK TRUSS STDTL04.112/23/19
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL05TRUSSED VALLEY SET DETAIL - SHEATHED
P 12
VALLEY TRUSS
(TYPICAL)
BASE TRUSSES
SEE DETAIL "A"
BELOW (TYP.)
VALLEY TRUSS
(TYPICAL)
GABLE END, COMMON
TRUSS, OR GIRDER TRUSS
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
DETAIL A
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
JULY 17, 2017
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL06TRUSSED VALLEY SET DETAIL
P 12
VALLEY TRUSS
(TYPICAL)
BASE TRUSSES
SEE DETAIL "A"
BELOW (TYP.)
VALLEY TRUSS
(TYPICAL)
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
DETAIL A
(NO SHEATHING) N.T.S.
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A".
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
FEBRUARY 5, 2018
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO
SIMPSON SDS25300 (1/4" X 3")
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL07TRUSSED VALLEY SET DETAIL
(HIGH WIND VELOCITY)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST BE
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
NOTE: VALLEY STUD SPACING NOT TO
EXCEED 48" O.C. SPACING.
ATTACH VALLEY TRUSSES TO LOWER TRUSSES
WITH USP RT7 OR EQUIVALENT.
NON-BEVELED
BOTTOM CHORD
NON-BEVELED
BOTTOM CHORD
JULY 17, 2017
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
MAXIMUM STUD LENGTH
2X4 SP #3 / STUD 12" O.C.
16" O.C.
24" O.C.
2X4 SP #3 / STUD
2X4 SP #3 / STUD
2X4 SP #2 12" O.C.
16" O.C.
24" O.C.
2X4 SP #2
2X4 SP #2
3-8-10
3-3-10
2-8-6
5-6-11
4-9-12
3-11-3
6-6-11
6-6-11
5-4-12
11-1-13
9-10-15
8-1-2
3-10-15 5-6-11 6-6-11 11-8-14
10-8-0
9-3-13
6-6-11
6-2-9
4-9-12
3-11-3
3-6-11
3-1-4
3X4 =
12
A
A
* *
*
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH
DURATION OF LOAD INCREASE : 1.60
STDTL08STANDARD GABLE END DETAIL
B B
+
+
+
+
**
STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
CONNECTION OF BRACING IS BASED ON MWFRS.
FEBRUARY 17, 2017
**
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL09FEBRUARY 17, 2017
T-BRACE / I-BRACE DETAIL
WITH 2X BRACE ONLY
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL10FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
45.00°45.00°45.00°
STDTL11FEBRUARY 17, 2017 LATERAL TOE-NAIL DETAIL
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
L
STDTL12FEBRUARY 17, 2017 UPLIFT TOE-NAIL DETAIL
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
FEBRUARY 5, 2016 ST-2x2 NAILINGTYP 2x2 NAILER ATTACHMENT
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
1.5 x 4
1.5 x 4
2 x 4 SP No . 2 (M in )2x4 SP No. 2 (Min)
2x2 SP No. 3
STDTL13
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
April 11, 2016 ST-FLAT GIR BRACETYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
(4) 12d
MAX 30" (2'-6")
2x6 #2 SP (Both Faces)
24" o.c.
SIMPSON H5
(4) 12d
TRUSS 24" o.c.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
VARIES
12
STDTL14
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL15FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND
DAMAGED OR MISSING CHORD SPLICE PLATES
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946
STDTL16FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS
(L)
24" MAX
(2.0 x L)
24" MIN
Rama Pranav Kristam, P.E.
# 889064451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946