Loading...
HomeMy WebLinkAboutWS-LOT-10 MANUAL-JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:48:46 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-10.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Aug 06, 2020Date:Entire House By: Project Information WATERSTONE LOT-10For: ARMINA PL. LOT-10 BLOCK-3, FT. PIERCE, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 5040Inside humidity (%) 5911Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140481A*Cond GSZ140481A* AHRI ref 4514267 Coil AR*F374316C* AHRI ref 4514267 Efficiency 8.5 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh32900 Heating output Btu h @ 47°F47000 Latent cooling Btuh14100 Temperature rise °F27 Total cooling Btuh47000 Actual air flow cfm1567 Actual air flow cfm1567 Air flow factor cfm/Btuh0.067 Air flow factor cfm/Btuh0.047 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.70 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) DINING AREA 122 1373 2922 92 138 GREAT ROOM 288 3482 3081 233 145 EX STE BED 163 2644 2730 177 129 KITCHEN 150 2489 2974 167 140 FOYER 110 1224 678 82 32 EX STE BATH 64 545 181 36 9 1ST FL STAIR 70 898 478 60 23 2ND FL HALL BATH 68 789 650 53 31 2ND FL OS BATH 98 645 595 43 28 2ND FL OS WIC 53 67 268 5 13 2ND FL OS BED 229 2329 4979 156 235 2ND FL HALL 151 1030 1022 69 48 2ND FL MECH 16 20 463 1 22 2ND FL LAUNDRY 47 59 819 4 39 2ND FL LOFT 157 1157 1699 77 80 2ND FL BED 2 164 1675 3336 112 157 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:48:46 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 2 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-10.rup Calc = MJ8 Front Door faces: W 2ND FL BED 3 157 1147 2919 77 138 2ND FL BED 4 165 1845 3409 123 161 Entire House 2273 23417 33202 1567 1567 Other equip loads 0 0 Equip. @ 0.95 RSM 31708 Latent cooling 14128 TOTALS 2273 23417 45836 1567 1567 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Aug-07 15:48:46 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-10.rup Calc = MJ8 Front Door faces: W Job:Project Summary Aug 06, 2020Date:Entire House By: Project Information WATERSTONE LOT-10For: ARMINA PL. LOT-10 BLOCK-3, FT. PIERCE, FL 34951 Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16 Daily range L Relative humidity %50 Moisture difference gr/lb59 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh17293 Structure Btuh22870 Ducts Btuh6124 Ducts Btuh10332 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh23417 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh31708 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh11307 Ducts Btuh2821 CoolingHeating Central vent (0 cfm)Btuh0 22732273Area (ft²)Equipment latent load Btuh14128 1924419244Volume (ft³) Air changes/hour 0.110.22 Equipment total load Btuh45836 Equiv. AVF (cfm)3571 Req. total capacity at 0.70 SHR ton3.8 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140481A*Cond GSZ140481A* AHRI ref 4514267 Coil AR*F374316C* AHRI ref 4514267 Efficiency 8.5 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh32900 Heating output Btu h @ 47°F47000 Latent cooling Btuh14100 Temperature rise °F27 Total cooling Btuh47000 Actual air flow cfm1567 Actual air flow cfm1567 Air flow factor cfm/Btuh0.067 Air flow factor cfm/Btuh0.047 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.70