Loading...
HomeMy WebLinkAboutTruss Package6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0010 - Design Code: FBC2017/TPI2014 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Design Program: MiTek 20/20 8.2 1 of 2 This package includes 40 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: 55.0 psf Site Information: Lot/Block: 10 Customer Info: K Hovnanian Homes Project Name: WS0010 Model: Emerald-B Subdivision: Waterstone Address: 5190 Armina Pl., . State: FLCity: Fort Pierce Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: August 25,2020 Lee, Julius The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Lee, Julius My license renewal date for the state of Florida is February 28, 2021. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No.Seal#Truss Name 1 T21111430 CJ01 Date 8/25/202T21111431CJ18/25/203T21111432CJ038/25/204T21111433CJ38/25/205T21111434CJ58/25/206T21111435EJ058/25/207T21111436EJ78/25/208T21111437FG018/25/209T21111438FG028/25/2010T21111439FG038/25/2011T21111440FL018/25/2012T21111441FL028/25/2013T21111442FL02A8/25/2014T21111443FL038/25/20 No.Seal#Truss Name 15 T21111444 FL04 Date 8/25/2016T21111445FL058/25/2017T21111446FL068/25/2018T21111447FL078/25/2019T21111448HJ058/25/2020T21111449HJ78/25/2021T21111450T098/25/2022T21111451T108/25/2023T21111452T118/25/2024T21111453T128/25/2025T21111454T138/25/2026T21111455T148/25/2027T21111456T158/25/2028T21111457T168/25/20 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: WS0010 - 2 of 2 Site Information: Lot/Block: 10 Customer Info: K Hovnanian Homes Project Name: WS0010 Model: Emerald-B Subdivision: Waterstone Address: 5190 Armina Pl., . State: FLCity: Fort Pierce No.Seal#Truss Name 29 T21111458 T17 Date 8/25/2030T21111459T188/25/2031T21111460T198/25/2032T21111461T208/25/2033T21111462T218/25/2034T21111463T228/25/2035T21111464T238/25/2036T21111465T248/25/2037T21111466T258/25/2038T21111467T268/25/2039T21111468V028/25/2040T21111469V038/25/20 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss CJ01 Truss Type Corner Jack Qty 4 Ply 1 Job Reference (optional) T21111430 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:02 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-NKgeAjc8YA0_rlC94HetoXsiwTnpOIsRI3?NVWykKsd Scale = 1:6.1 1 2 3 4 2x4 ST1.5x8 STP 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-3-150-7-150-3-120-7-154.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.01 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=38(LC 12) Max Uplift 3=-8(LC 1), 2=-119(LC 12) Max Grav 3=21(LC 12), 2=125(LC 1), 4=18(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=119. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss CJ1 Truss Type Corner Jack Qty 4 Ply 1 Job Reference (optional) T21111431 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:03 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-rWD1N2dmJU8qTvnLe_96LkOtjs717l6bXjlw2zykKsc Scale = 1:6.5 1 2 3 4 2x4 1-0-0 1-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-10-9-10-4-100-9-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=48(LC 12) Max Uplift 3=-4(LC 9), 2=-114(LC 12) Max Grav 3=16(LC 12), 2=121(LC 1), 4=19(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=114. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss CJ03 Truss Type Corner Jack Qty 4 Ply 1 Job Reference (optional) T21111432 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:03 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-rWD1N2dmJU8qTvnLe_96LkOsOs5G7l6bXjlw2zykKsc Scale = 1:9.4 1 2 5 3 4 2x4 ST1.5x8 STP 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-3-151-3-150-4-30-11-121-3-154.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=68(LC 12) Max Uplift 3=-36(LC 12), 2=-137(LC 12) Max Grav 3=52(LC 1), 2=187(LC 1), 4=52(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=137. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss CJ3 Truss Type Corner Jack Qty 4 Ply 1 Job Reference (optional) T21111433 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:04 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-JinPbOdO4nGh42MXBigLuyx1UGRAsCMklNUUaPykKsb Scale = 1:10.8 1 2 5 3 4 2x4 3-0-0 3-0-0 -1-0-0 1-0-0 3-0-0 3-0-0 0-4-11-7-11-2-101-7-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.22 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-50(LC 12), 2=-119(LC 12) Max Grav 3=63(LC 1), 2=178(LC 1), 4=56(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=119. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss CJ5 Truss Type Corner Jack Qty 4 Ply 1 Job Reference (optional) T21111434 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:05 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-nuLnoke0r5OYiCxklPCaQ9U7OglJbfcu_1E16rykKsa Scale = 1:14.9 1 2 5 6 3 4 2x4 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-12-5-12-0-102-5-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.53 0.28 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 -0.00 (loc) 2-4 2-4 3 l/defl >999 >909 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=124(LC 12) Max Uplift 3=-103(LC 12), 2=-136(LC 12) Max Grav 3=122(LC 1), 2=247(LC 1), 4=96(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=103, 2=136. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss EJ05 Truss Type Jack-Open Qty 2 Ply 1 Job Reference (optional) T21111435 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:05 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-nuLnoke0r5OYiCxklPCaQ9U8eglgbfcu_1E16rykKsa Scale = 1:12.7 1 2 5 6 3 4 2x4 ST1.5x8 STP 5-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 0-3-151-11-154.00 12 Plate Offsets (X,Y)-- [2:0-2-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.45 0.26 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=99(LC 12) Max Uplift 3=-89(LC 12), 2=-155(LC 12) Max Grav 3=114(LC 1), 2=253(LC 1), 4=92(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=155. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss EJ7 Truss Type Jack-Open Qty 14 Ply 1 Job Reference (optional) T21111436 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:06 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-G5v9?4fecPXPKMWwJ7jpzN0Fk41zK6s1DhzaeIykKsZ Scale = 1:18.8 1 2 5 6 3 4 3x4 7-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 0-4-13-3-12-10-103-3-15.00 12 Plate Offsets (X,Y)-- [2:0-0-6,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.75 0.51 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.12 -0.21 -0.00 (loc) 2-4 2-4 3 l/defl >681 >394 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=163(LC 12) Max Uplift 3=-132(LC 12), 2=-157(LC 12) Max Grav 3=165(LC 1), 2=318(LC 1), 4=125(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=132, 2=157. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FG01 Truss Type FLOOR Qty 1 Ply 2 Job Reference (optional) T21111437 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:07 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-kHTXDQgHNifGyW56tqE2VaZTeUOd3OiBSLj8BkykKsY Scale = 1:12.6 1 2 3 6 5 4 6x8 6x8 2x4 2x4 5x8 2x4 0-3-0 0-3-0 3-7-0 3-4-0 6-11-0 3-4-0 0-3-0 0-3-0 3-7-0 3-4-0 6-11-0 3-4-0 1-6-0Plate Offsets (X,Y)-- [5:0-4-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.55 0.42 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.07 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 85 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 *Except* 1-5,3-5: 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-4-0, 6=0-4-0 Max Grav 4=3298(LC 1), 6=3298(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4920/0, 2-3=-4920/0, 3-4=-2551/0 WEBS 1-5=0/5177, 2-5=-1940/0, 3-5=0/5177, 1-6=-2551/0 NOTES-(5) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Girder carries tie-in span(s): 20-6-4 from 0-0-0 to 6-11-0; 17-9-4 from 0-0-0 to 6-11-0 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-3=-600(F=-500), 4-6=-435(B=-425) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FG02 Truss Type FLOOR Qty 2 Ply 2 Job Reference (optional) T21111438 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:07 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-kHTXDQgHNifGyW56tqE2VaZOIULh3NEBSLj8BkykKsY Scale: 3/8"=1' 1 2 3 4 5 6 7 14 13 12 11 10 9 8 4x6 ST1.5x8 STP 6x12 MT20HS 3x6 6x12 MT20HS 4x6 6x12 MT20HS 2x4 10x12 10x12 5x6 5x6 2x4 2x4 2x4 3-10-0 3-10-0 7-4-8 3-6-8 10-6-0 3-1-8 14-2-4 3-8-4 18-0-4 3-10-0 3-10-0 3-10-0 7-4-8 3-6-8 10-6-0 3-1-8 14-2-4 3-8-4 18-0-4 3-10-0 1-6-0Plate Offsets (X,Y)-- [8:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.61 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.32 -0.43 0.03 (loc) 9-10 9-10 8 l/defl >667 >489 n/a L/d 360 240 n/a PLATES MT20 MT20HS Weight: 192 lb FT = 20% GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 *Except* 7-9,1-13,3-13,4-9: 2x4 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)14=0-7-4, 8=0-3-8 Max Grav 14=1566(LC 1), 8=3227(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-1358/0, 1-2=-4011/0, 2-3=-4011/0, 3-4=-8182/0, 4-6=-8747/0, 6-7=-8747/0, 7-8=-2789/0 BOT CHORD 11-13=0/8182, 10-11=0/8182, 9-10=0/8182, 8-9=0/464 WEBS 6-9=-301/40, 7-9=0/8660, 1-13=0/3945, 3-13=-4446/0, 4-9=0/1220, 2-13=-317/24, 3-11=0/954, 4-10=-590/0 NOTES-(8) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 2 rows staggered at 0-2-0 oc, Except member 9-7 2x4 - 1 row at 0-9-0 oc, member 1-13 2x4 - 1 row at 0-9-0 oc, member 13-3 2x4 - 1 row at 0-9-0 oc, member 4-9 2x4 - 1 row at 0-9-0 oc, member 13-2 2x4 - 1 row at 0-9-0 oc, member 3-11 2x4 - 1 row at 0-9-0 oc, member 10-4 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 5 = 20%, joint 12 = 20% 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2843 lb down at 14-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-7=-100, 8-14=-10 Continued on page 2 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FG02 Truss Type FLOOR Qty 2 Ply 2 Job Reference (optional) T21111438 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:07 2020 Page 2 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-kHTXDQgHNifGyW56tqE2VaZOIULh3NEBSLj8BkykKsY LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 9=-2843(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FG03 Truss Type FLOOR Qty 1 Ply 2 Job Reference (optional) T21111439 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:08 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-CT1wQmgv80n7ZgfJQYlH2o5XOtkmopaKg?ShjAykKsX Scale = 1:20.1 1 2 3 4 8 7 6 591011121314 4x6 5x6 5x6 4x6 5x8 2x4 4x6 5x6 4-0-9 4-0-9 7-11-7 3-10-13 12-0-0 4-0-9 4-0-9 4-0-9 7-11-7 3-10-13 12-0-0 4-0-9 1-6-0Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [4:0-3-0,0-1-12], [5:Edge,0-3-8], [6:0-3-0,0-1-12], [7:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.99 0.43 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.20 0.01 (loc) 6-7 6-7 5 l/defl >936 >688 n/a L/d 360 240 n/a PLATES MT20 Weight: 152 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 *Except* 1-7,3-7,4-6: 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=Mechanical, 5=Mechanical Max Grav 8=2934(LC 1), 5=2853(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-1952/0, 1-2=-6600/0, 2-3=-6600/0, 3-4=-6708/0, 4-5=-1970/0 BOT CHORD 7-8=0/679, 6-7=0/6708, 5-6=0/671 WEBS 1-7=0/6128, 4-6=0/6249 NOTES-(6) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 751 lb down at 0-10-12, 750 lb down at 2-10-12, 750 lb down at 4-10-12, 750 lb down at 6-10-12, and 750 lb down at 8-10-12, and 750 lb down at 10-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-100, 5-8=-10 Concentrated Loads (lb) Vert: 9=-751(B) 10=-750(B) 11=-750(B) 12=-750(B) 13=-750(B) 14=-750(B) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL01 Truss Type Floor Supported Gable Qty 2 Ply 1 Job Reference (optional) T21111440 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:09 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-ggbIe6hXvKv_BqEV_FGWb?ewOHAVXS6TvfCFFcykKsW Scale = 1:34.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 37 38 3x6 FP 3x4 3x4 3x6 FP 20-9-12 20-9-12 0-1-8 1-6-01-6-0LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.01 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 19 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 96 lb FT = 20%F, 11%E GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) OTHERS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-9-12. (lb) - Max Grav All reactions 250 lb or less at joint(s) 36, 19, 35, 34, 33, 32, 31, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL02 Truss Type FLOOR Qty 7 Ply 1 Job Reference (optional) T21111441 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:10 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-8s8grSi9gd1rpzphYynl7DBu2hIuGkhd8Jxoo3ykKsV Scale = 1:35.0 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 3x12 MT20HS FP 1.5x3 1.5x3 1.5x3 3x4 3x6 FP 3x6 5x8 5x8 1.5x3 3x4 3x4 3x8 5x8 5x8 1.5x3 3x4 3x4 1.5x3 1.5x3 20-9-12 20-9-12 2-5-0 1-7-14 2-0-0 1-7-14 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [14:0-1-8,Edge], [15:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.92 0.90 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.36 -0.49 0.09 (loc) 13-14 13-14 12 l/defl >681 >504 n/a L/d 360 240 n/a PLATES MT20 MT20HS Weight: 106 lb FT = 20%F, 11%E GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)18=0-7-4, 12=0-3-8 Max Grav 18=1128(LC 1), 12=1128(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3126/0, 3-4=-3126/0, 4-5=-4172/0, 5-6=-4172/0, 6-7=-4172/0, 7-9=-3152/0, 9-10=-3152/0 BOT CHORD 17-18=0/1815, 15-17=0/3898, 14-15=0/4172, 13-14=0/3912, 12-13=0/1855 WEBS 2-18=-2075/0, 2-17=0/1499, 4-17=-883/0, 4-15=-70/684, 10-12=-2109/0, 10-13=0/1484, 7-13=-869/0, 7-14=-82/673, 5-15=-315/0, 6-14=-310/0 NOTES-(5) 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL02A Truss Type Floor Qty 6 Ply 1 Job Reference (optional) T21111442 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:11 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-c2i23ojnRx9iQ7Ou6gJ_gQj3o5e7?BxmMzhLKVykKsU Scale = 1:34.1 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 21 3x12 MT20HS FP 3x6 FP 3x6 5x8 5x8 3x4 3x4 5x8 5x8 5x8 3x4 3x4 20-9-12 20-9-12 2-5-0 1-7-14 2-0-0 1-7-14 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [12:Edge,0-1-8], [14:0-1-8,Edge], [15:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.92 0.90 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.36 -0.49 0.09 (loc) 13-14 13-14 12 l/defl >681 >504 n/a L/d 360 240 n/a PLATES MT20 MT20HS Weight: 106 lb FT = 20%F, 11%E GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)18=0-7-4, 12=0-3-8 Max Grav 18=1127(LC 1), 12=1121(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3126/0, 3-4=-3126/0, 4-5=-4172/0, 5-6=-4172/0, 6-7=-4172/0, 7-9=-3153/0, 9-10=-3153/0 BOT CHORD 17-18=0/1815, 15-17=0/3898, 14-15=0/4172, 13-14=0/3912, 12-13=0/1853 WEBS 2-18=-2075/0, 2-17=0/1499, 4-17=-883/0, 4-15=-70/684, 10-12=-2102/0, 10-13=0/1486, 7-13=-868/0, 7-14=-82/673, 5-15=-315/0, 6-14=-310/0 NOTES-(6) 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) All plates are 1.5x3 MT20 unless otherwise indicated. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL03 Truss Type Floor Qty 4 Ply 1 Job Reference (optional) T21111443 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:12 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-4FGQG7jPCEHZ2Hz4fNqDCeGECV?dkfRwbdQvsxykKsT Scale = 1:34.5 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 3x12 MT20HS FP 1.5x3 1.5x3 1.5x3 3x4 3x6 FP 3x6 5x8 5x8 1.5x3 3x4 3x8 5x8 5x8 1.5x3 3x4 1.5x3 3x4 1.5x3 3x4 20-6-4 20-6-4 2-5-0 1-7-14 2-0-0 1-4-6 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [14:0-1-8,Edge], [15:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.94 0.88 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.47 0.08 (loc) 15-17 15-17 12 l/defl >697 >514 n/a L/d 360 240 n/a PLATES MT20 MT20HS Weight: 105 lb FT = 20%F, 11%E GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)18=0-7-4, 12=Mechanical Max Grav 18=1111(LC 1), 12=1111(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3069/0, 3-4=-3069/0, 4-5=-4052/0, 5-6=-4052/0, 6-7=-4052/0, 7-9=-3093/0, 9-10=-3093/0 BOT CHORD 17-18=0/1787, 15-17=0/3811, 14-15=0/4052, 13-14=0/3825, 12-13=0/1824 WEBS 2-18=-2043/0, 2-17=0/1467, 4-17=-849/0, 10-12=-2074/0, 10-13=0/1451, 7-13=-837/0, 5-15=-299/0, 4-15=-88/645, 6-14=-339/10, 7-14=-91/650 NOTES-(6) 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL04 Truss Type Floor Supported Gable Qty 2 Ply 1 Job Reference (optional) T21111444 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:13 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-YRqpTTk1yYPQgRYGD5LSlrpcGuXBTG43qHASOOykKsS Scale = 1:29.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 30 31 3x6 3x4 17-8-12 17-8-12 0-1-8 1-6-01-6-0LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 83 lb FT = 20%F, 11%E GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) OTHERS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-8-12. (lb) - Max Grav All reactions 250 lb or less at joint(s) 29, 16, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7) 1) All plates are 1.5x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 4) Gable studs spaced at 1-4-0 oc. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL05 Truss Type Floor Qty 8 Ply 1 Job Reference (optional) T21111445 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:14 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-1dOBhplgjsXHHb7SnoshI3Lc6IflCb4C3xv?xqykKsR Scale = 1:29.7 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x4 3x6 3x6 5x8 3x8 3x4 5x8 3x8 3x4 10-4-12 10-4-12 18-0-4 7-7-8 2-5-0 2-0-0 0-4-12 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [6:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.79 0.90 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.36 0.06 (loc) 11-12 11-12 10 l/defl >740 >596 n/a L/d 360 240 n/a PLATES MT20 Weight: 94 lb FT = 20%F, 11%E GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 16=0-7-4 Max Grav 10=974(LC 1), 16=974(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2570/0, 3-4=-2570/0, 4-5=-3100/0, 5-6=-3100/0, 6-7=-2591/0, 7-8=-2591/0 BOT CHORD 15-16=0/1538, 14-15=0/3100, 13-14=0/3100, 12-13=0/3100, 11-12=0/3100, 10-11=0/1571 WEBS 2-16=-1759/0, 2-15=0/1180, 3-15=-293/21, 4-15=-854/0, 8-10=-1786/0, 8-11=0/1166, 7-11=-295/15, 6-11=-837/0 NOTES-(5) 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL06 Truss Type Floor Qty 4 Ply 1 Job Reference (optional) T21111446 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:15 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-VqyZu9mIU9f8vlifLWNwqGun_i0?x2VMHbfZTGykKsQ Scale = 1:29.3 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x4 3x6 3x6 5x8 3x8 3x4 5x8 3x8 3x4 10-1-12 10-1-12 17-9-4 7-7-8 2-5-0 2-0-0 0-1-12 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [6:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.84 0.55 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.32 0.05 (loc) 11-12 11-12 10 l/defl >822 >653 n/a L/d 360 240 n/a PLATES MT20 Weight: 93 lb FT = 20%F, 11%E GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=Mechanical, 16=0-7-4 Max Grav 10=960(LC 1), 16=960(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2522/0, 3-4=-2522/0, 4-5=-3020/0, 5-6=-3020/0, 6-7=-2542/0, 7-8=-2542/0 BOT CHORD 15-16=0/1513, 14-15=0/3020, 13-14=0/3020, 12-13=0/3020, 11-12=0/3020, 10-11=0/1546 WEBS 2-16=-1730/0, 2-15=0/1153, 3-15=-291/14, 4-15=-807/0, 8-10=-1757/0, 8-11=0/1139, 7-11=-292/9, 6-11=-791/0 NOTES-(6) 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x3 MT20 unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss FL07 Truss Type Floor Qty 6 Ply 1 Job Reference (optional) T21111447 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:16 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-z0Wx6VnwFTn_XuHruDu9NURwt6MZgX2VWFO6?iykKsP Scale: 1/2"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 1.5x3 1.5x3 1.5x3 1.5x3 3x4 3x6 3x6 1.5x3 3x4 1.5x3 3x4 3x6 3x4 1.5x3 14-0-12 14-0-12 2-5-0 2-0-0 1-7-12 0-1-8 1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [9:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.83 0.88 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.30 0.03 (loc) 10-11 10-11 8 l/defl >712 >556 n/a L/d 360 240 n/a PLATES MT20 Weight: 71 lb FT = 20%F, 11%E GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.1(flat) BOT CHORD 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)12=0-7-4, 8=Mechanical Max Grav 12=760(LC 1), 8=760(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1834/0, 3-4=-1834/0, 4-5=-1775/0, 5-6=-1775/0 BOT CHORD 11-12=0/1153, 10-11=0/1775, 9-10=0/1775, 8-9=0/1163 WEBS 2-12=-1319/0, 2-11=0/779, 3-11=-331/0, 4-11=-269/229, 6-8=-1330/0, 6-9=0/845, 5-9=-366/0 NOTES-(5) 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. 5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss HJ05 Truss Type Diagonal Hip Girder Qty 2 Ply 1 Job Reference (optional) T21111448 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:17 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-RC4JJrnY0nvr82s1SxPOvhz9jWoGP4aflv8gX9ykKsO Scale = 1:15.7 1 2 5 3 6 7 4 3x4 7-0-2 7-0-2 -1-5-0 1-5-0 7-0-2 7-0-2 0-3-151-11-122.83 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.63 0.47 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.16 -0.00 (loc) 2-4 2-4 3 l/defl >978 >510 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-10-15, 4=Mechanical Max Horz 2=106(LC 4) Max Uplift 3=-122(LC 4), 2=-262(LC 4) Max Grav 3=154(LC 1), 2=301(LC 1), 4=114(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 3 and 262 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 26 lb down and 46 lb up at 4-2-15, and 26 lb down and 46 lb up at 4-2-15 on top chord, and 21 lb down and 37 lb up at 1-4-15, 21 lb down and 37 lb up at 1-4-15, and 18 lb down at 4-2-15, and 18 lb down at 4-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 2-4=-20 Concentrated Loads (lb) Vert: 6=61(F=30, B=30) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss HJ7 Truss Type Diagonal Hip Girder Qty 2 Ply 1 Job Reference (optional) T21111449 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:18 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-vPdiXBoAn41imCQE0exdSvWPPv9W8TJozZtD4bykKsN Scale = 1:20.6 1 2 3 7 6 8 9 10 4 11 12 13 52x4 3x4 3x4 2x4 5-8-1 5-8-1 9-10-1 4-1-15 -1-5-0 1-5-0 5-8-1 5-8-1 9-10-1 4-1-15 0-4-13-2-133.54 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.32 0.40 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.03 -0.05 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-4-9, 5=Mechanical Max Horz 2=162(LC 24) Max Uplift 4=-93(LC 8), 2=-189(LC 8), 5=-125(LC 8) Max Grav 4=107(LC 1), 2=449(LC 1), 5=329(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-759/261 BOT CHORD 2-7=-320/696, 6-7=-320/696 WEBS 3-6=-761/350, 3-7=0/301 NOTES-(8) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 lb uplift at joint 4, 189 lb uplift at joint 2 and 125 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 82 lb down and 80 lb up at 1-4-15, 82 lb down and 80 lb up at 1-4-15, 31 lb down and 62 lb up at 4-2-15, 31 lb down and 62 lb up at 4-2-15, and 56 lb down and 124 lb up at 7-0-14, and 56 lb down and 124 lb up at 7-0-14 on top chord, and 2 lb down at 1-4-15, 2 lb down at 1-4-15, 19 lb down at 4-2-15, 19 lb down at 4-2-15, and 39 lb down at 7-0-14, and 39 lb down at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 2-5=-20 Concentrated Loads (lb) Vert: 8=42(F=21, B=21) 10=-91(F=-46, B=-46) 13=-39(F=-20, B=-20) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T09 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T21111450 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:19 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-NbB4kXpoYO9ZOM?QaLSs?63RiJODttnyCDdmc1ykKsM Scale = 1:60.4 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 4x6 4x6 3x6 4x6 3x4 2x4 3x8 3x4 3x8 3x4 2x4 4x6 3x6 7-7-12 7-7-12 13-0-0 5-4-4 22-0-0 9-0-0 27-4-4 5-4-4 35-0-0 7-7-12 -1-0-0 1-0-0 7-7-12 7-7-12 13-0-0 5-4-4 17-6-0 4-6-0 22-0-0 4-6-0 27-4-4 5-4-4 35-0-0 7-7-12 36-0-0 1-0-0 0-4-15-9-10-4-15-9-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [8:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.86 0.88 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.54 0.13 (loc) 12-13 12-13 8 l/defl >999 >776 n/a L/d 240 180 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-14 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-130(LC 10) Max Uplift 2=-627(LC 12), 8=-627(LC 12) Max Grav 2=1346(LC 1), 8=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2721/1505, 3-4=-2144/1278, 4-5=-1930/1243, 5-6=-1930/1243, 6-7=-2144/1278, 7-8=-2721/1505 BOT CHORD 2-15=-1275/2433, 13-15=-1275/2433, 12-13=-1002/2035, 10-12=-1282/2433, 8-10=-1282/2433 WEBS 3-15=0/258, 3-13=-606/422, 4-13=-283/579, 5-13=-295/185, 5-12=-295/186, 6-12=-283/579, 7-12=-606/421, 7-10=0/258 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 8. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T10 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T21111451 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:20 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-rnlSxtqQJiHQ?Wac73z5XKbbljh9cFJ5RtMK8UykKsL Scale = 1:61.4 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 3x6 5x8 4x6 3x6 3x6 3x6 3x4 2x4 3x4 3x8 3x4 2x4 3x6 3x6 8-9-1 8-9-1 15-0-0 6-2-15 20-0-0 5-0-0 26-2-15 6-2-15 35-0-0 8-9-1 -1-0-0 1-0-0 8-9-1 8-9-1 15-0-0 6-2-15 20-0-0 5-0-0 26-2-15 6-2-15 35-0-0 8-9-1 36-0-0 1-0-0 0-4-16-7-10-4-16-7-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [5:0-5-12,0-2-8], [9:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.97 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.22 -0.42 0.13 (loc) 2-16 2-16 9 l/defl >999 >998 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 *Except* 1-4,7-10: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-3-8, 9=0-3-8 Max Horz 2=-149(LC 10) Max Uplift 2=-627(LC 12), 9=-627(LC 12) Max Grav 2=1346(LC 1), 9=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2667/1440, 3-5=-1961/1182, 5-6=-1746/1159, 6-8=-1961/1182, 8-9=-2666/1440 BOT CHORD 2-16=-1204/2376, 14-16=-1204/2376, 13-14=-795/1745, 11-13=-1212/2376, 9-11=-1212/2376 WEBS 3-16=0/341, 3-14=-746/478, 5-14=-203/466, 6-13=-220/467, 8-13=-745/478, 8-11=0/341 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2) 15-0-0 to 19-2-15, Interior(1) 19-2-15 to 20-0-0, Exterior(2) 20-0-0 to 24-2-15, Interior(1) 24-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 9. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T11 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T21111452 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:22 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-oAtCMYrhrJY8Fpk?FU?Zclh_JXO_4C2OuArRDMykKsJ Scale = 1:61.3 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 14 19 20 21 22 23 24 3x4 2x4 3x4 3x8 3x4 3x4 2x4 8-9-9 8-9-9 17-0-0 8-2-7 17-6-0 0-6-0 18-0-0 0-6-0 26-2-7 8-2-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-10-12 6-10-12 12-3-13 5-5-1 17-0-0 4-8-3 17-6-0 0-6-0 18-0-0 0-6-0 22-8-3 4-8-3 28-1-4 5-5-1 35-0-0 6-10-12 36-0-0 1-0-0 0-4-17-5-10-4-17-5-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [6:0-3-0,0-2-4], [8:0-3-0,0-2-4], [12:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.94 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.43 0.13 (loc) 14-16 16-18 12 l/defl >999 >974 n/a L/d 240 180 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-3-8, 12=0-3-8 Max Horz 2=-167(LC 10) Max Uplift 2=-627(LC 12), 12=-627(LC 12) Max Grav 2=1346(LC 1), 12=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2734/1401, 3-5=-2528/1363, 5-6=-1729/1043, 6-7=-1548/1001, 7-8=-1548/1001, 8-9=-1729/1043, 9-11=-2528/1363, 11-12=-2734/1401 BOT CHORD 2-18=-1185/2453, 16-18=-906/1967, 14-16=-913/1967, 12-14=-1192/2453 WEBS 3-18=-316/283, 5-18=-227/559, 5-16=-606/439, 9-16=-606/439, 9-14=-227/559, 11-14=-316/283, 7-16=-521/1004 NOTES-(8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2) 17-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 3x6 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 12. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T12 Truss Type Common Qty 2 Ply 1 Job Reference (optional) T21111453 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:23 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-GMRbausJcdg?szJBpBWo9yD9jwkDpf9X7qb_lpykKsI Scale = 1:59.3 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 3x6 4x6 3x6 3x6 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 3x6 3x6 8-9-9 8-9-9 17-6-0 8-8-7 26-2-7 8-8-7 35-0-0 8-9-9 -1-0-0 1-0-0 6-10-11 6-10-11 12-3-12 5-5-1 17-6-0 5-2-4 22-8-4 5-2-4 28-1-5 5-5-1 35-0-0 6-10-11 36-0-0 1-0-0 0-4-17-7-90-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [10:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.73 0.94 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.43 0.13 (loc) 12-14 12-14 10 l/defl >999 >978 n/a L/d 240 180 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-172(LC 10) Max Uplift 2=-627(LC 12), 10=-627(LC 12) Max Grav 2=1346(LC 1), 10=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2733/1356, 3-5=-2528/1316, 5-6=-1728/997, 6-7=-1728/997, 7-9=-2528/1316, 9-10=-2733/1356 BOT CHORD 2-16=-1127/2452, 14-16=-844/1971, 12-14=-862/1971, 10-12=-1141/2452 WEBS 6-14=-516/1021, 7-14=-615/418, 7-12=-223/556, 9-12=-313/279, 5-14=-615/418, 5-16=-223/556, 3-16=-313/279 NOTES-(6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-6-0, Exterior(2) 17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 10. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T13 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T21111454 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:24 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-kY?znEtxNwosU7uNMv11iAmMyK6uYA?hMUKXHFykKsH Scale = 1:60.4 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 5x8 5x8 3x6 3x6 3x4 2x4 3x4 3x8 2x4 3x4 3x4 2x4 3x6 3x6 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 -1-0-0 1-0-0 6-6-5 6-6-5 11-0-0 4-5-11 17-6-0 6-6-0 24-0-0 6-6-0 28-5-11 4-5-11 35-0-0 6-6-5 36-0-0 1-0-0 0-4-14-11-10-4-14-11-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [4:0-5-12,0-2-8], [6:0-5-12,0-2-8], [8:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.63 0.79 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.24 -0.40 0.13 (loc) 13 13-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 174 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-10 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-112(LC 10) Max Uplift 2=-627(LC 12), 8=-627(LC 12) Max Grav 2=1346(LC 1), 8=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2774/1565, 3-4=-2308/1381, 4-5=-2465/1521, 5-6=-2465/1521, 6-7=-2308/1381, 7-8=-2774/1565 BOT CHORD 2-16=-1342/2488, 15-16=-1342/2488, 13-15=-1045/2091, 11-13=-1051/2091, 10-11=-1347/2488, 8-10=-1347/2488 WEBS 3-15=-479/350, 4-15=-149/385, 4-13=-295/578, 5-13=-401/351, 6-13=-295/578, 6-11=-149/385, 7-11=-479/350 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2) 11-0-0 to 15-2-15, Interior(1) 15-2-15 to 24-0-0, Exterior(2) 24-0-0 to 28-5-11, Interior(1) 28-5-11 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 8. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T14 Truss Type Hip Qty 2 Ply 1 Job Reference (optional) T21111455 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:25 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-ClYL?auZ8Ewj6HTawcZGENJSzkPNHbvqa845phykKsG Scale = 1:60.4 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 19 20 21 22 23 24 4x6 4x6 4x6 3x6 4x6 3x8 2x4 3x4 3x4 3x4 3x8 2x4 4x6 3x6 9-0-0 9-0-0 17-6-0 8-6-0 26-0-0 8-6-0 35-0-0 9-0-0 -1-0-0 1-0-0 5-8-11 5-8-11 9-0-0 3-3-5 13-4-12 4-4-12 21-7-4 8-2-8 26-0-0 4-4-12 29-3-5 3-3-5 35-0-0 5-8-11 36-0-0 1-0-0 0-4-14-1-10-4-14-1-15.00 12 Plate Offsets (X,Y)-- [2:0-0-10,Edge], [6:0-3-0,Edge], [10:0-0-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.94 0.96 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.29 -0.49 0.15 (loc) 14 12-14 10 l/defl >999 >847 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=93(LC 11) Max Uplift 2=-627(LC 12), 10=-627(LC 12) Max Grav 2=1346(LC 1), 10=1346(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2749/1613, 3-4=-2491/1454, 4-5=-2286/1393, 5-7=-2894/1692, 7-8=-2286/1393, 8-9=-2491/1454, 9-10=-2749/1613 BOT CHORD 2-16=-1391/2486, 14-16=-1481/2810, 12-14=-1488/2810, 10-12=-1398/2486 WEBS 3-16=-279/308, 4-16=-418/813, 5-16=-773/499, 7-12=-773/499, 8-12=-418/813, 9-12=-279/308 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2) 9-0-0 to 13-4-12, Interior(1) 13-4-12 to 26-0-0, Exterior(2) 26-0-0 to 30-2-15, Interior(1) 30-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at joint 10. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T15 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T21111456 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:29 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-4Wosqxx4BTQ8aumL9SdCODT9mLp5DNIQVm2IySykKsC Scale = 1:60.4 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 5x8 3x6 5x8 3x6 4x6 2x4 5x8 2x4 2x4 3x8 2x4 5x8 2x4 4x6 3x6 7-0-0 7-0-0 12-3-14 5-3-14 17-6-0 5-2-2 22-8-2 5-2-2 28-0-0 5-3-14 35-0-0 7-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 12-3-14 5-3-14 17-6-0 5-2-2 22-8-2 5-2-2 28-0-0 5-3-14 35-0-0 7-0-0 36-0-0 1-0-0 0-4-13-3-10-4-13-3-15.00 12 Plate Offsets (X,Y)-- [3:0-5-12,0-2-8], [8:0-5-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.78 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.46 -0.72 0.16 (loc) 14 13-14 9 l/defl >910 >582 n/a L/d 240 180 n/a PLATES MT20 Weight: 325 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 7-0-3 oc bracing. REACTIONS. (size)2=0-3-8, 9=0-3-8 Max Horz 2=74(LC 24) Max Uplift 2=-1242(LC 8), 9=-1265(LC 8) Max Grav 2=2686(LC 1), 9=2703(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6119/2707, 3-4=-7929/3617, 4-6=-7928/3617, 6-7=-7941/3637, 7-8=-7942/3637, 8-9=-6162/2764 BOT CHORD 2-17=-2377/5552, 15-17=-2381/5580, 14-15=-3820/8737, 13-14=-3820/8737, 11-13=-2434/5619, 9-11=-2429/5591 WEBS 3-17=-89/664, 3-15=-1225/2776, 4-15=-611/475, 6-15=-966/424, 6-14=0/480, 6-13=-939/400, 7-13=-603/468, 8-13=-1188/2734, 8-11=-89/663 NOTES-(10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1242 lb uplift at joint 2 and 1265 lb uplift at joint 9. Continued on page 2 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T15 Truss Type HIP GIRDER Qty 1 Ply 2 Job Reference (optional) T21111456 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:29 2020 Page 2 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-4Wosqxx4BTQ8aumL9SdCODT9mLp5DNIQVm2IySykKsC NOTES-(10) 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 130 lb down and 150 lb up at 7-0-0, 111 lb down and 147 lb up at 9-0-12, 111 lb down and 147 lb up at 11-0-12, 111 lb down and 147 lb up at 13-0-12, 111 lb down and 147 lb up at 15-0-12, 111 lb down and 147 lb up at 17-0-12, 111 lb down and 147 lb up at 17-11-4, 111 lb down and 147 lb up at 19-11-4, 111 lb down and 147 lb up at 21-11-4, 111 lb down and 147 lb up at 23-11-4, and 111 lb down and 147 lb up at 25-11-4, and 189 lb down and 267 lb up at 28-0-0 on top chord, and 361 lb down and 152 lb up at 7-0-0, 85 lb down at 9-0-12, 85 lb down at 11-0-12, 85 lb down at 13-0-12, 85 lb down at 15-0-12, 85 lb down at 17-0-12, 85 lb down at 17-11-4, 85 lb down at 19-11-4, 85 lb down at 21-11-4, 85 lb down at 23-11-4, and 85 lb down at 25-11-4, and 361 lb down and 152 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-10=-54, 2-9=-20 Concentrated Loads (lb) Vert: 3=-111(B) 5=-111(B) 8=-142(B) 17=-361(B) 11=-361(B) 18=-111(B) 19=-111(B) 21=-111(B) 22=-111(B) 23=-111(B) 24=-111(B) 25=-111(B) 27=-111(B) 28=-111(B) 29=-61(B) 30=-61(B) 31=-61(B) 32=-61(B) 33=-61(B) 34=-61(B) 35=-61(B) 36=-61(B) 37=-61(B) 38=-61(B) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T16 Truss Type Common Supported Gable Qty 1 Ply 1 Job Reference (optional) T21111457 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:30 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-ZiME2HxiymY?C2LXj98RxQ0UKlJxyx2ZkQnsVvykKsB Scale = 1:19.3 1 2 3 4 5 6 9 8 7 10 11 12 13 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 11-0-0 11-0-0 -1-0-0 1-0-0 5-6-0 5-6-0 11-0-0 5-6-0 0-4-12-7-90-4-15.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.17 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-0-0. (lb) - Max Horz 2=61(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6 except 2=-119(LC 12), 9=-128(LC 12), 7=-147(LC 12) Max Grav All reactions 250 lb or less at joint(s) 6, 2, 8 except 9=258(LC 1), 7=272(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-9=-178/372, 5-7=-185/379 NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 5-6-0, Corner(3) 5-6-0 to 8-6-0, Exterior(2) 8-6-0 to 11-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 2=119, 9=128, 7=147. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T17 Truss Type Common Qty 3 Ply 1 Job Reference (optional) T21111458 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:31 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-1vwcFdyKj4gsqCwkHtfgUeYcU9cfhOYjz4XP1LykKsA Scale = 1:19.2 1 2 3 4 5 6 7 8 9 4x6 3x4 3x4 2x4 5-6-0 5-6-0 11-0-0 5-6-0 -1-0-0 1-0-0 5-6-0 5-6-0 11-0-0 5-6-0 0-4-12-7-90-4-15.00 12 Plate Offsets (X,Y)-- [2:0-1-6,Edge], [4:0-1-6,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.33 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-11-14 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8 Max Horz 2=61(LC 11) Max Uplift 4=-169(LC 12), 2=-248(LC 12) Max Grav 4=396(LC 1), 2=464(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-636/413, 3-4=-634/430 BOT CHORD 2-5=-301/531, 4-5=-301/531 WEBS 3-5=-22/253 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-6-0, Exterior(2) 5-6-0 to 8-6-0, Interior(1) 8-6-0 to 10-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=169, 2=248. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T18 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 Job Reference (optional) T21111459 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:33 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-zH1MgJ_aFhwa3W46OIi8Z3epTy8698D?QO0W6DykKs8 Scale = 1:62.3 1 2 3 4 5 6 7 8 9 10 11 12 18 17 16 15 14 13 19 20 21 22 23 5x8 3x6 4x6 4x6 4x6 6x8 2x4 3x8 3x4 7x10 3x4 3x8 2x4 3x8 5x8 2x4 7-0-0 7-0-0 11-0-12 4-0-12 15-2-0 4-1-4 16-3-4 1-1-4 23-4-0 7-0-12 25-8-0 2-4-0 29-1-12 3-5-12 35-0-0 5-10-4 -1-0-0 1-0-0 7-0-0 7-0-0 11-0-12 4-0-12 12-5-5 1-4-9 16-3-4 3-9-15 19-8-12 3-5-8 23-4-0 3-7-4 25-8-0 2-4-0 29-1-12 3-5-12 30-0-2 0-10-5 35-0-0 4-11-14 36-0-0 1-0-0 0-4-13-3-14-2-120-4-13-3-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-2-11], [3:0-5-12,0-2-8], [14:0-4-12,0-5-0], [17:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.91 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.48 -0.75 0.13 (loc) 14-15 14-15 11 l/defl >866 >559 n/a L/d 240 180 n/a PLATES MT20 Weight: 396 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-10-12 oc bracing. REACTIONS. (size)2=0-3-8, 11=0-3-8 Max Horz 2=96(LC 24) Max Uplift 2=-1357(LC 8), 11=-1123(LC 8) Max Grav 2=2904(LC 1), 11=2408(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6772/3050, 3-4=-9246/4271, 4-5=-10683/4904, 5-7=-10683/4904, 7-8=-7640/3501, 8-9=-5226/2388, 9-10=-5261/2387, 10-11=-5519/2503 BOT CHORD 2-18=-2695/6172, 17-18=-2695/6180, 15-17=-4105/9246, 14-15=-4113/9292, 13-14=-3335/7640, 11-13=-2208/5033 WEBS 4-15=-722/1642, 7-14=-2189/999, 8-14=-607/1400, 4-17=-1149/615, 3-17=-1727/3756, 5-15=-384/302, 7-15=-858/1885, 9-13=-1708/3810, 8-13=-4470/2086, 10-13=-284/265 NOTES-(10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=1357, 11=1123. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 151 lb down and 147 lb up at 13-0-12, and 151 lb down and 147 lb up at 15-0-12 on top chord, and 889 lb down and 439 lb up at 11-0-12, 85 lb down at 13-0-12, and 85 lb down at 15-0-12, and 1388 lb down and 657 lb up at 16-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Continued on page 2 This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T18 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 Job Reference (optional) T21111459 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:33 2020 Page 2 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-zH1MgJ_aFhwa3W46OIi8Z3epTy8698D?QO0W6DykKs8 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-12=-54, 2-11=-20 Concentrated Loads (lb) Vert: 15=-1388(F) 17=-889(F) 20=-111(F) 21=-111(F) 22=-61(F) 23=-61(F) Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T19 Truss Type Monopitch Girder Qty 1 Ply 1 Job Reference (optional) T21111460 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:34 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-RUbltf?C0?2RhffIy?DN5GA3cMbDumn9f2l3egykKs7 Scale = 1:19.7 1 2 34563x6 3x4 4x6 7-0-0 7-0-0 7-0-0 7-0-0 0-4-13-3-15.00 12 Plate Offsets (X,Y)-- [3:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.62 0.47 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.13 -0.21 0.00 (loc) 1-3 1-3 3 l/defl >610 >392 n/a L/d 240 180 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=Mechanical Max Horz 1=158(LC 7) Max Uplift 1=-320(LC 8), 3=-419(LC 8) Max Grav 1=718(LC 1), 3=909(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=320, 3=419. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 376 lb down and 189 lb up at 2-0-12, and 376 lb down and 189 lb up at 4-0-12, and 378 lb down and 187 lb up at 6-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 1-3=-20 Concentrated Loads (lb) Vert: 4=-376(B) 5=-376(B) 6=-378(B) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T20 Truss Type Monopitch Girder Qty 1 Ply 1 Job Reference (optional) T21111461 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:35 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-vg975??rnJAIJpEVWjkceUj9dmtndD1IuiVdA6ykKs6 Scale = 1:18.9 1 2 34563x6 3x4 4x10 MT20HS 7-0-0 7-0-0 7-0-0 7-0-0 0-4-13-3-15.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-11], [2:0-0-13,0-1-8], [3:0-5-0,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.93 0.77 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.21 -0.33 0.00 (loc) 1-3 1-3 3 l/defl >382 >244 n/a L/d 240 180 n/a PLATES MT20 MT20HS Weight: 31 lb FT = 20% GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-0-8 oc bracing. REACTIONS. (size)1=0-3-8, 3=Mechanical Max Horz 1=158(LC 5) Max Uplift 1=-475(LC 8), 3=-637(LC 8) Max Grav 1=1074(LC 1), 3=1408(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=475, 3=637. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 661 lb down and 313 lb up at 2-0-12, and 661 lb down and 313 lb up at 4-0-12, and 663 lb down and 311 lb up at 6-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 1-3=-20 Concentrated Loads (lb) Vert: 4=-661(F) 5=-661(F) 6=-663(F) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T21 Truss Type Common Supported Gable Qty 1 Ply 1 Job Reference (optional) T21111462 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:36 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-NsjVIL0TYcI9wzoh3QFrBhGWRAMlMftS6MEAiYykKs5 Scale = 1:32.8 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 4x6 3x4 3x4 5x6 18-8-0 18-8-0 -1-0-0 1-0-0 9-4-0 9-4-0 18-8-0 9-4-0 0-4-14-2-110-4-15.00 12 Plate Offsets (X,Y)-- [14:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.15 0.14 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 83 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-8-0. (lb) - Max Horz 2=97(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 10, 15, 16, 13, 12 except 2=-108(LC 12), 17=-116(LC 12), 11=-137(LC 12) Max Grav All reactions 250 lb or less at joint(s) 10, 2, 14, 15, 16, 17, 13, 12 except 11=252(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 9-11=-172/305 NOTES-(10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 9-4-0, Corner(3) 9-4-0 to 12-4-0, Exterior(2) 12-4-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 15, 16, 13, 12 except (jt=lb) 2=108, 17=116, 11=137. 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T22 Truss Type Common Qty 3 Ply 1 Job Reference (optional) T21111463 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:37 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-r2HtWh15JwR0Y7Ntd7m4jvodbaXa54zbL0_jF?ykKs4 Scale = 1:31.6 1 2 3 4 5 6 7 8 9 10 11 4x6 3x6 3x6 5x8 2x4 2x4 9-4-0 9-4-0 18-8-0 9-4-0 -1-0-0 1-0-0 5-11-10 5-11-10 9-4-0 3-4-6 12-8-6 3-4-6 18-8-0 5-11-10 0-4-14-2-110-4-15.00 12 Plate Offsets (X,Y)-- [7:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.87 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.32 0.03 (loc) 6-7 6-7 6 l/defl >999 >702 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-5-13 oc bracing. REACTIONS. (size)6=Mechanical, 2=0-3-8 Max Horz 2=97(LC 11) Max Uplift 6=-293(LC 12), 2=-369(LC 12) Max Grav 6=681(LC 1), 2=747(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1249/705, 3-4=-972/556, 4-5=-973/573, 5-6=-1262/722 BOT CHORD 2-7=-578/1110, 6-7=-578/1126 WEBS 4-7=-307/599, 5-7=-344/314, 3-7=-326/302 NOTES-(7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-4-0, Exterior(2) 9-4-0 to 12-4-0, Interior(1) 12-4-0 to 18-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=293, 2=369. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T23 Truss Type Common Supported Gable Qty 1 Ply 1 Job Reference (optional) T21111464 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:37 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-r2HtWh15JwR0Y7Ntd7m4jvoeqajU56RbL0_jF?ykKs4 Scale = 1:16.2 1 2 3 4 5 6 7 8 9 10 4x6 3x6 3x6 2x4 6-8-0 6-8-0 -1-0-0 1-0-0 3-4-0 3-4-0 6-8-0 3-4-0 7-8-0 1-0-0 0-4-32-0-30-4-36.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.11 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.01 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=6-8-0, 4=6-8-0, 6=6-8-0 Max Horz 2=-60(LC 10) Max Uplift 2=-147(LC 12), 4=-147(LC 12), 6=-43(LC 12) Max Grav 2=185(LC 1), 4=185(LC 1), 6=231(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 3-4-0, Corner(3) 3-4-0 to 6-4-0, Exterior(2) 6-4-0 to 7-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 2=147, 4=147. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T24 Truss Type Common Qty 2 Ply 1 Job Reference (optional) T21111465 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:38 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-KFrFj02j4EZtAHy4BrIJG6Lr6z3kqawlagjHnRykKs3 Scale = 1:16.3 1 2 3 4 5 6 7 8 4x6 ST1.5x8 STP ST1.5x8 STP 2x4 2x4 2x4 3-4-0 3-4-0 6-8-0 3-4-0 -1-0-0 1-0-0 3-4-0 3-4-0 6-8-0 3-4-0 7-8-0 1-0-0 0-4-32-0-30-4-36.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.11 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 2-6 2-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-8-0, 4=0-8-0 Max Horz 2=-60(LC 10) Max Uplift 2=-178(LC 12), 4=-178(LC 12) Max Grav 2=294(LC 1), 4=294(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-251/171, 3-4=-251/171 NOTES-(6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-4-0, Exterior(2) 3-4-0 to 6-4-0, Interior(1) 6-4-0 to 7-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=178, 4=178. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T25 Truss Type Hip Girder Qty 1 Ply 1 Job Reference (optional) T21111466 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:39 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-oRPexM2LrXhknRXGlYpYoKu_iNJlZ0WuoKTqJtykKs2 Scale = 1:22.8 1 2 3 4 5 6 8 7 4x6 ST1.5x8 STP ST1.5x8 STP 4x6 3x4 3x4 2x4 2x4 5-0-0 5-0-0 7-0-0 2-0-0 12-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 7-0-0 2-0-0 12-0-0 5-0-0 13-0-0 1-0-0 0-3-151-11-150-3-151-11-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 NO FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.44 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 0.02 (loc) 5-7 5-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-3-15 oc bracing. REACTIONS. (size)2=0-8-0, 5=0-8-0 Max Horz 2=-35(LC 6) Max Uplift 2=-326(LC 8), 5=-338(LC 8) Max Grav 2=649(LC 1), 5=663(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1245/494, 3-4=-1142/493, 4-5=-1251/499 BOT CHORD 2-8=-393/1127, 7-8=-393/1142, 5-7=-398/1132 WEBS 3-8=0/256 NOTES-(9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=326, 5=338. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb down and 105 lb up at 5-0-0, and 185 lb down and 249 lb up at 7-0-0 on top chord, and 110 lb down at 5-0-0, and 110 lb down at 6-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-6=-54, 2-5=-20 Concentrated Loads (lb) Vert: 3=-60(B) 4=-138(B) 8=-66(B) 7=-66(B) This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss T26 Truss Type Common Qty 2 Ply 1 Job Reference (optional) T21111467 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:40 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-Gdz08i3zcrpaPb6SIGKnLXQ9AngBITj11_COrJykKs1 Scale = 1:22.4 1 2 3 4 5 6 7 8 9 10 4x6 ST1.5x8 STP ST1.5x8 STP 3x4 3x4 2x4 6-0-0 6-0-0 12-0-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 12-0-0 6-0-0 13-0-0 1-0-0 0-3-152-3-150-3-154.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge], [4:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.37 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 4-6 4-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-11-14 oc bracing. REACTIONS. (size)2=0-8-0, 4=0-8-0 Max Horz 2=41(LC 11) Max Uplift 2=-264(LC 12), 4=-264(LC 12) Max Grav 2=491(LC 1), 4=491(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-742/439, 3-4=-742/439 BOT CHORD 2-6=-313/649, 4-6=-313/649 WEBS 3-6=0/262 NOTES-(6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-0-0, Exterior(2) 6-0-0 to 9-0-0, Interior(1) 9-0-0 to 13-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=264, 4=264. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss V02 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) T21111468 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:41 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-kqWOM24bM9xR1khfszr0ulzFDB0p1xWBGeyxOmykKs0 Scale = 1:13.1 1 2 3 4 2x4 2x4 2x4 5-0-0 5-0-0 0-0-42-1-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.66 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-11-6, 3=4-11-6 Max Horz 1=97(LC 9) Max Uplift 1=-62(LC 12), 3=-69(LC 12) Max Grav 1=152(LC 1), 3=152(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6904 Parke East Blvd. Tampa, FL 36610 Job WS0010 Truss V03 Truss Type Valley Qty 2 Ply 1 Job Reference (optional) T21111469 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 25 10:23:42 2020 Page 1 Builders First Source, Plant City, FL - 32566, ID:YHWDr0mBnrebqkOSNfKX?FyquAG-C04mZO5E7S3IeuGrQhMFQyWYubQ8mOmKVIhUwCykKs? Scale = 1:9.0 1 2 3 2x4 2x4 2x4 3-0-0 3-0-0 0-0-41-3-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.25 1.25 YES FBC2017/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 244/190 LUMBER- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-11-6, 3=2-11-6 Max Horz 1=50(LC 11) Max Uplift 1=-32(LC 12), 3=-35(LC 12) Max Grav 1=78(LC 1), 3=78(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6) 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. August 25,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths