HomeMy WebLinkAboutUnderlayment - FL 2569-R197/27/2020
Florida Building Code Online
�m
W
BCiS Home Log In User Registration Hot Topics Submit Surcharge Stats Ek Facts Publicatians Contact Us SCES Site Map Links Search
bo
q' Product Approval
USER: Public User
Product Approval Menu > Product or Appilcatron Search > 812pli4ation List > Application Detail
FL # FL2569-R19
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu @soprema. ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean- Berchma ns- Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2 69 Rig COI 2020 01 OI NIEM EN.pdf
Referenced Standard and Year (of Standard) SA@ndard
Year
ASTM U1970
2015
ASTM D4798
2011
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
https:llfloridabuilding.org/prlpr_app_dtl.aspx?param=wG EVXQwtDgsKQFErickB 108Erxl Ud3xYIR3WFL46CdQtjQl l ynvE6gkAa/o3d%3d 1 /2
7/27/2020
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/09/2020
Date Validated
04/09/2020
Date Pending FBC Approval
04/14/2020
Date Approved
06/02/2020
Summary of Products
FL*
Model, Number or Name
Description
2569.1
Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underlayment systems
used beneath adhesive -set tile systems. Refer to ER Section
Installation Instructions
FL2569 R12 IL 4_06 EINALL25pdf
Verified By; Robert Nleminen, A.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R19 8E 2020 04 06 FINAL ER -Ri
Created by Independent Third Party. Yes
5.6.4 for details.
------------------------
Back Hext
Contact :: 2501 Blalr Stone Road Tallahaggee EL 32399 Phonw-4 -
The State of Florida Is an AglEEO employer. 2007-2013 State of F Pr9vap Statement Accessibility Statemen lRri�a.. � � j :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by tmdltlonal mail, If you have any questions, please contact $50.487.1395. 'Pursuant to section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F S., please click here .
Product Approval Accept:
rT NFEN r
Creditr
Safe
se curitvm ETRLC S'
https;//floridabuiIding-0rg/pr/pr_app_dti.aspx?param=wGEVXQwtDgsKQFEnckB108Erx 1 Ud3xYlR3W FL46CdQuQI1 ynvE6gkA%3d%3d 2/2
0
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVA.W.-ATION REPORT
Soprema, Inc. Evaluation Report S18010.06.09-1117
1640 rue Haggerty FL2569-1119
Drummondville, Quebec JZC 5P8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 17: 04/06/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION' Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
.....
Robert J.M. Nieminen P.E.
,
"� `` s `' a' ?`{`
•., W�._ hf;?�F The facsimile seal appearing was authorized by Robert
Florida Registration No. S9166, Florida DCA ANE1983
''•.S^i ,, a4 :«• Nieminen, P.E. on 04106/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO) etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02019 NEMO ETC, LLC
NEMO I etc.
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement;
Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the
61 Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Pro a Standard Year
1504.3.1
Wind Resistance FM 4474 2011
1504.3.1
Wind Uplift UL 1897 2012
1507.1.1, 1507.2.9.2, R905.1.1, Physical Properties ASTM D1970 2015
R905.2.8.2
1507.3.3, R905.3.3
Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012 (04-12)
Physical Properties ASTM D6163 2008
TAS 110
Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Ent!
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970/TAS 110 (QC)
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12 (OH)
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTIVI D1970 (QC)
544870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SQPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-R1
06/07/2017
M-D (CER1592)
HVHZ Compliance
18-0329.03
06/28/2018
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970/TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
PRI (TST5878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
07/18/2017
NEMO ETC, LLC Evaluation Report S18030.06.09-1117
Certifcare of Authorirarion#32455 6T � EDITION 42017) FBC NON-HVHZ EVALUATION F1,2569-1119
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 2 of a
4. PRODUcr DESCRIPTION:
Product
Specification
Plant(s)
Description
4.1
Lastobond TU HT
ASTM D1970 and
Gulfport, M5
self -adhering, non -woven polyester fabric surfaced,
FRSA/TRI April 2012
SBS modified bitumen roof underlayment
4.2
Lastobond Shield
ASTM D1970
Drummondville, QC
Self -adhering, woven polyethylene surfaced, 5135
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.3
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
4.4
Lastobond Shield HT
ASTM D1970
Drummondville, QC
Self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.5
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.6
Lastobond Pro HT-S
ASTM 01970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.7
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SIBS modified bitumen roof
underlayment
4.8
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -surfaced,
Wadsworth, OH
SBS modified bitumen roof underlayment
4.9
Lastobond Eaves
ASTM 01970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -surfaced,
Protection Sheet
Wadsworth, OH
SBS modified bitumen roof underlayment
4.10
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.11
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced,
HT
Wadsworth, OH
SBS. modified bitumen roof underlayment
4.12
PrimeSource Grip -Rite
ASTM ❑1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced,
Smooth Seal HT
Wadsworth, OH
SBS modified bitumen roof underlayment
4.13
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.14
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Eave & Valley Protector
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.15
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
WATER DEFENDER
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.16
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.17
Galphene FR. GR
A5TM D1970 and
Gulfport, MS
self -adhering, fiberglass reinforced, granule-
FRSA/TRI April 2012
Wadsworth, OH
surfaced, SBS modified bitumen roof underlayment
NEMSO ETC, LLC
Certificate of Authorization #32455
6- EDITION (2017) FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report 518010.06.09-1117
FL2569-R19
Revision 17: 04/06/2020
Page 3 of 8
ONEMOletc.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMCI ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood or
Slate or
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Composite
Composite
Shingles
Tile
Tile
Shakes &
Shingles
Slate
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
Yes
See 5.5.1
Lastobond Shield / Pro HT-N /
RESISTO SA SMOOTH PLY 40
Yes
No
No
No
Yes
Yes
Lastobond Shield HT/ Pro HT-S
Yes
No
No
Yes
Yes
Yes
Enviro5hield
Yes
No
No
Yes
Yes
Yes
Lastobond Eaves Protection Sheet /
Lastobond 195
Yes
No
No
No
Yes
Yes
Lastobond ECO / RESISTO LB1236,
Grip -Rite Eave & Valley Protector /
TopShield ICE & WATER DEFENDER /
Yes
No
No
No
Yes
Yes
RESISTO LB1244
Lastobond Smooth Seal HT / Grip-
Rite Smooth Seal HT
Yes
No
No
Yes
Yes
Yes
Colphene FR GR
Yes
Yes
No
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Lastobond TU HT
Dupont TILE BON DTM
FL22525
ICP Adhesives Polyset• AH-160
FL6332
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance,
NEMO ETC, LLC Evaluation Report S18010.06.09-R17
Certificate ofRuthorizatlon #3I455 6"' EDITION (20171 FBC NON-HVHZ EVALUATION FL2569-Rig
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 4 of 8
5.6
5.6.1
5.6.2
NNEMO I etc.
Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS
Underlayment
Primer
Substrates
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
(Optional) ASTM D41,
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Elastocol Stick, Elastocol Stick
plywood, OSB, Southern Yellow
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection
Zero
Pine (SYP)
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT or
ASTM D41
structural concrete
Grip -Rite Smooth Seal HT
Colphene FR GR
(Optional) ASTM D41
Plywood
ASTM D41
structural concrete
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection
Dens Deck Prime; S K
Sheet, Lastobond 195, Lastobond ECO, RESISTO L61236,
(Optional) Elastocol Stick Zero
Board;
Gypsum -Fiber Roof Board;
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
ASTM D226, Type I or 14 felt;
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT,
Sopra-G; Modified Sopra-G
Grip -Rite Smooth Seal HT or Colphene FR GR
Existing sand -surfaced, glass-
RESISTO LB1236, Grip -Rite Eave & Valley Protector or
RESISTO EXTERIOR PRIMER
fiber surfaced, mineral -surfaced
TopShield ICE & WATER DEFENDER
or film -surfaced roof
underlayment*
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite
Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
Soprema recommends priming with Elastocol Stick, Elastocal 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D, Testing Application Standard TAS 114, Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum
codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be
attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underla ment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
NEMO ETC, LLC
Cer ffrcate of Authoritotion #32455
6"' EDITION (2017) FBC NC)N-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report S19010.06.09-1117
FL2569-R19
Revision 17. 04/06/Z020
Page 5 of 9
*NEMO I etc.
#1 Maximum Design Pressure = -45.0 Psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with 5oprema requirements to ensure no voids no bridging at side and end -laps.
#3 Maximum Design Pressure = -120.0 psf:
Deck: Min, 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer; (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -
laps.
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#4 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#5 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps
5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
NEMO ETC, LLC Evaluation Report 518010.06.09-1117
Certifrcate njAuthorization #32455 04 EDITION (20171 FBC NON-HVH2 EVALUATION FL2569_RIB
Soprema Roof underlayments Revision 17. 04/06/2.020
Page 6 of 8
NNEnna j etc.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip -Rite Eave & Valley
Protector, TopShleld ICE & WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days
after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Enviro5hield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 _Tile Siippape Limitations RAS 103 per FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 3: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack shall be inverted,
followed by S tiles high on slope, as shown} below]
6:12
Lastobond TU HT
Lugged
Colphene FR GR
Flat
Max. 10-tile stack
5:12
Lugged
Max. 10-tile stack
6.12
NEYIO ETC, LLC Evaluation Report 518010.06.09-1117
Certificate of Authorization #32455 6Ttr` EDITION (2017) FEIC NON-HVHZ EVALUATION FL2569-R19
5oprema Roof Underlayments Revision 17: 04/06/2020
Page 7 of 8
MEMO j etc.
6. INSTALLATION;
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER (if applicable).
6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector orTop5hield ICE & WATER DEFENDER self -adhering
underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the
existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off)
installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to
the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector orTop5hield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
1*1
6.3.1
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShleld, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, Top5hield ICE &
WATER DEFENDER, RESISTO LB1244 or Colphene FIR GR:
rvon- i lie Apprlcavons:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or FBC
Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published
requirements.
6.3.2 Tile Applications (Lastobond TU HT or ColpheneFR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema
published requirements.
For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane,
fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than
that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1.
For foam -on tile applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein, and Soprema published requirements for tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
Refer to Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
MEMO ETC, LLC Evaluation Report S18010.06.09-1117
Certificate of Authartzation#32455 6'" EDITION 12017) FBC NON-HVHZ EVALUATION F1.2569-1114
Soprema Roof Underlayments Revision 17: 04/06/2020