HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 6 Block 2 Waterstone 3000 BGL
Builder Name: ADAMS HOMES
Street: 8304 Cristelle Court
Permit Office:
City, State, Zip: Port Saint Lucie , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2135.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1835.30 ft2
b. Frame - Wood, Adjacent
R=13.0 300.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3000.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 3000.00 ft2
6. Conditioned floor area above grade (ft2) 3000
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(309.8 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 600
a. U-Factor: Dbl, U=0.33 159.82 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 97.13 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
47.5 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.25 ft2
a. Electric Heat Pump
45.0 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 1.499 ft.
Area Weighted Average SHGC: 0.282
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (3000.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.103 Total Proposed Modified Loads: 81.70
PASS
Total Baseline Loads: 83.14
I hereby certify that the plans and specifications covered by
Review of the plans and
STAty
this calculation are in complian
specifications covered by this
�ZiB
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
0
DATE: 06-11-217120 Winn KPomany
this building will be inspected for
compliance with Section 553.908
O
I hereby certify that this building, as designed, is in compliance
the Florida ire
Florida Statutes.
COD T¢�
with ode.
Wg
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope FrLP
noter than 7.00 ACH50 (R402.4.1.2).
VIEWED FOR
(;ODE COMPLIANCE
CICOUNTY
6/11/2020 4:38 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th i `(2 Comp cant Software Page 1 of 4
,OCC
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 6 Block 2 Waterstone 300 Bedrooms: 4
User Conditioned Area: 3000
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 6
Block/Subdivision: Waterstone
PlatBook:
Street: 8304 Cristelle Court
County: St. Lucie
City, State, Zip: Port Saint Lucie ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
3000 25500
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
3000 25500 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 223.5 ft 0
3000 ft2 ---- 0.46 0 0.54
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 3355 ft2 752 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 3000 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
3000 ft2 0.11 Wood
6/11/2020 4:38 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
To
Wall
3�vpp1
Space
E
Exterior
Concrete Block - Int Insul
Main
4.1 64
8
8 0
517.3 ft2
0
0 0.6
0
2
N
Exterior
Concrete Block - Int Insul
Main
4.1 65
0
8 0
520.0 ft2
0
0 0.6
0
3
W
Exterior
Concrete Block - Int Insul
Main
4.1 49
0
8 0
392.0 ft2
0
0 0.6
0
4
S
Exterior
Concrete Block - Int Insul
Main
4.1 50
9
8 0
406.0 ft2
0
0 0.6
0
5
-
Garage
Frame - Wood
Main
13 30
0
10 0
300.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
1 ft 0 in
None
None
2
N
2
Vinyl
Low-E Double
Yes
0.55 0.7
N
35.6 ft2
1 ft 4 in
1 ft 0 in
None
None
3
N
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
65.8 ft2
1 ft 4 in
1 ft 0 in
None
None
4
N
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
None
None
5
W
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
19.5 ft2
1 ft 4 in
1 ft 0 in
None
None
6
S
4
Vinyl
Low-E Double
Yes
0.33 0.21
N
64.8 ft2
1 ft 4 in
1 ft 0 in
None
None
7
S
4
Vinyl
Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 4 in
1 ft 4 in
None
None
8
S
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.3 ft2
4 ft 3 in
1 ft 6 in
None
None
9
S
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.3 ft2
4 ft 4 in
1 ft 6 in
None
None
10
S
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
6.7 ft2
4 ft 4 in
3 ft 10 in
None
None
11
N
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
448 ft2
448 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA
EgLA
ACH •
ACH 50
1 Wholehouse
Proposed ACH(50) .000378
2975 163.32
307.15
.1342
7
6/11/2020 4:38 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 45 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15 47.5 kBtu/hr 1583 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
-- Supply ---
V # Location R-Value Area
--- Return ---- Air
Location Area Leakage Type Handler
CFM 25
TOT
CFM25
OUT
QN
RLF
HVAC #
Heat Cool
1 Attic
6 600 ft2
Main
150 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan [[ ]] Feb
HeatinJan [X] Feb
Jan [[ ]] Feb
Mar
Mar
X Mar
Ceiling Fans:
[ ] Apr May [X Jun Jul rj
[ ]Apr I May E Jun Jl Au
Augrj
[X] A r May Jun Jul Aug
Se
Sep
Se
[Xl
Oct
Oct
Oct
Nov
Nov
X Nov
Dec
H DecVentin
Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM
PM
Cooling (WEH) AM
PM
Heating (WD) AM
PM
Heating (WEH) AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft 0.3
Main
6/11/2020 4:38 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family) .
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
47.5
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
3000
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.355
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.282
14. Heating system: Capacity
45.0
c) Area
7c.
309.8
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Sign Date:
Address of New Home: 8304 Cristelle Court City/FL Zip: Port Saint Lucie, FL 34951
6/11/2020 4:38:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1