Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 6 Block 2 Waterstone 3000 BGL Builder Name: ADAMS HOMES Street: 8304 Cristelle Court Permit Office: City, State, Zip: Port Saint Lucie , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2135.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1835.30 ft2 b. Frame - Wood, Adjacent R=13.0 300.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3000.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 3000.00 ft2 6. Conditioned floor area above grade (ft2) 3000 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(309.8 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 600 a. U-Factor: Dbl, U=0.33 159.82 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 97.13 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 47.5 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.25 ft2 a. Electric Heat Pump 45.0 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.499 ft. Area Weighted Average SHGC: 0.282 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (3000.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.103 Total Proposed Modified Loads: 81.70 PASS Total Baseline Loads: 83.14 I hereby certify that the plans and specifications covered by Review of the plans and STAty this calculation are in complian specifications covered by this �ZiB Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed 0 DATE: 06-11-217120 Winn KPomany this building will be inspected for compliance with Section 553.908 O I hereby certify that this building, as designed, is in compliance the Florida ire Florida Statutes. COD T¢� with ode. Wg OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope FrLP noter than 7.00 ACH50 (R402.4.1.2). VIEWED FOR (;ODE COMPLIANCE CICOUNTY 6/11/2020 4:38 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th i `(2 Comp cant Software Page 1 of 4 ,OCC FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 6 Block 2 Waterstone 300 Bedrooms: 4 User Conditioned Area: 3000 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 6 Block/Subdivision: Waterstone PlatBook: Street: 8304 Cristelle Court County: St. Lucie City, State, Zip: Port Saint Lucie , FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 3000 25500 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3000 25500 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 223.5 ft 0 3000 ft2 ---- 0.46 0 0.54 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 3355 ft2 752 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3000 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 3000 ft2 0.11 Wood 6/11/2020 4:38 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below To Wall 3�vpp1 Space E Exterior Concrete Block - Int Insul Main 4.1 64 8 8 0 517.3 ft2 0 0 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 65 0 8 0 520.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 49 0 8 0 392.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 50 9 8 0 406.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 30 0 10 0 300.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 0 in None None 2 N 2 Vinyl Low-E Double Yes 0.55 0.7 N 35.6 ft2 1 ft 4 in 1 ft 0 in None None 3 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 65.8 ft2 1 ft 4 in 1 ft 0 in None None 4 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in None None 5 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 19.5 ft2 1 ft 4 in 1 ft 0 in None None 6 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 64.8 ft2 1 ft 4 in 1 ft 0 in None None 7 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 4 in 1 ft 4 in None None 8 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 4 ft 3 in 1 ft 6 in None None 9 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 4 ft 4 in 1 ft 6 in None None 10 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 4 ft 4 in 3 ft 10 in None None 11 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 448 ft2 448 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH • ACH 50 1 Wholehouse Proposed ACH(50) .000378 2975 163.32 307.15 .1342 7 6/11/2020 4:38 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 45 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 47.5 kBtu/hr 1583 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply --- V # Location R-Value Area --- Return ---- Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 600 ft2 Main 150 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan [[ ]] Feb HeatinJan [X] Feb Jan [[ ]] Feb Mar Mar X Mar Ceiling Fans: [ ] Apr May [X Jun Jul rj [ ]Apr I May E Jun Jl Au Augrj [X] A r May Jun Jul Aug Se Sep Se [Xl Oct Oct Oct Nov Nov X Nov Dec H DecVentin Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM PM Heating (WEH) AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 6/11/2020 4:38 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) . 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 47.5 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3000 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.355 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.282 14. Heating system: Capacity 45.0 c) Area 7c. 309.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sign Date: Address of New Home: 8304 Cristelle Court City/FL Zip: Port Saint Lucie, FL 34951 6/11/2020 4:38:23 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1